BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Public Works Roads Department - PWRD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date22 Oct 2024
Closing Date30 Oct 2024
Tender Amount₹ 3,00,00,000 
Notes
Download

Costs

Summary

Te_ridf_xxx_24_25_385 Construction Of Road From (i) Pathimara Factory Point Tothaligram 8 No Of Pathimara Te (ii) Jagannath Mandir Point To Durgabari Via Sitola Mandir And Nutan Quarter Of Urunabond Te (iii) Pwd Main Road To Ram Prabash Chouhan House

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1,Private Land

594.96

339

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Clause 401,II) For Grading II Material

355.44

2518

-

... More
Providing , laying, spreading and compacting stone aggregates of specified sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with 3 wheels 80-100KN static roller in stages to proper grade and camber, applying and brooming stone screening / binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density as per Technical Specification Clause 405. (3) Grading - III (Screening B). A) By Manual Means-

213.26

4215

-

... More
Interlocking pavement block:Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage.Including Edge block/ Edge restraints

2833.19

1161

-

... More
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm equilateral triangle

4

3933

-

... More
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm circular

2

5345

-

... More
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 800mm x 600mm rectangular

4

7537

-

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing as per drawing Clause 1701 and Annexure 1700.1

1

24845

-

... More
Utility shifting

0.89

33900

-

... More
CULVERT+DRAIN+Protection work Earthwork in Excavation for foundation of structures up to 3.00 m depth as per drawing and technical specification Clause 1104 including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backs filling with approved materials

963.03

127

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B With natural Gravel I P.C.C Grade M 10

8.1

6036

-

... More
Bedding of pipe (A) Type A (Concrete Cradle) Bedding i) Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i)

3.44

5894

-

... More
Bedding for Pipe (ii) Type B (First class) bedding.laying (first class) bedding on well compacted sand,moorum or approved granular material as clause 1105(ii) (ii) Granular Materials

4.79

1558

-

... More
Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 ii Brick masonry in 1:4 cement mortar

16.76

7450

-

... More
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix in levelling course below open foundation of head wall as per drawings and technical specification clause 1109 A. With crushed stone

5.77

6078

-

... More
Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause802,803,1202&1203 (B) With Natural Gravel I.PCC Grade M10 (ii)nominal mix 1:3:6. (Hand Mixing)

44.63

5607

-

... More
Providing and laying Reinforced Concrete pipe NP-3 on 1st Class Bedding of granular material in single row as per drawing and technical specification Clause 1106 (B) 1000 mm dia.

12.5

7787

-

... More
Providing and laying Reinforced Concrete pipe NP-3 on 1st Class Bedding of granular material in single row as per drawing and technical specification Clause 1106 (C) 600 mm dia.

15

3272

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B. With Natural Gravel II P.C.C Grade M15 Nominal mix 1:2.5:5

35.04

5935

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 B B. With Natural Gravel I)M-15 Nominal mix (1:2:4) (Hand Mixed)

323

6582

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 B B. With Natural Gravel I)M-15 Nominal mix (1:2.5:5)

17.95

6278

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 B A With Crushed Stone I P.C.C grade M 15 i) Nominal mix (1:2.5:5)

38.94

6234

-

... More
Plastering with cement mortar in Prop. (1:4), 15 mm thick on brick wall in Substructure as per drawing and technical specification Clause 613.4 &1204

96.04

146

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A With crushed Stone IV R.C.C Grade M20

2.43

7072

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 A With crushed Stone IV R.C.C Grade M20

0.72

7480

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 A With crushed stone II R.C.C grade M 25 a) Height upto 5M

15.45

8677

-

... More
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in foundation complete as per drawings and technical specifications Clauses 1000 and 12

0.05

53572

-

... More
Supplying, fitting and placing MS Bar (Fe-500 ) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202

0.03

63585

-

... More
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar . (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

1.67

55239

-

... More
Providing pressure relief pipes 100 mm dia in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing and technical specification Clause 1205.5.7

8

717

-

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302

15.3

2856

-

... More
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301

135

3587

-

... More
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.

100

21

-

... More
(ii) Jagannath Mandir Point to Durgabari via Sitola Mandir and Nutan Quarter of Urunabond TE Clearing and Grubbing road land including uprooting wild vegetation ,grass,bushes,shrubs,saplings and trees of girth upto 300m,removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned ,upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150mm in thickness as per T.S clause 201.(i) By Manual Means (B)(b) In area of thorny jungle

0.58

76305

-

... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5(I) Private Land

351.75

258

-

... More
Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1

4127.75

106

-

... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1,Private Land

1856.7

339

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Clause 401,II) For Grading II Material

336.25

2254

-

... More
Providing , laying, spreading and compacting stone aggregates of specified sizes to water bound macadam specification including spreading in uniform thickness , hand packing ,rolling with 3 wheels 80-100KN static roller in stages to proper grade and camber, applying and brooming stone screening / binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density as per Technical Specification Clause 405. (3) Grading - III (Screening B). A) By Manual Means-

201.75

3916

-

... More
Interlocking pavement block:Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage.Including Edge block/ Edge restraints

2690

1161

-

... More
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm equilateral triangle

4

3933

-

... More
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm circular

4

5345

-

... More
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 800mm x 600mm rectangular

4

7537

-

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing as per drawing Clause 1701 and Annexure 1700.1

1

24845

-

... More
Utility shifting

0.72

33900

-

... More
CULVERT+DRAIN Earthwork in Excavation for foundation of structures up to 3.00 m depth as per drawing and technical specification Clause 1104 including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backs filling with approved materials

951.4

127

-

... More
Bedding for Pipe (ii) Type B (First class) bedding.laying (first class) bedding on well compacted sand,moorum or approved granular material as clause 1105(ii) (ii) Granular Materials

5.38

1558

-

... More
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix in levelling course below open foundation of head wall as per drawings and technical specification clause 1109 A. With crushed stone

3.93

6078

-

... More
Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause802,803,1202&1203 (B) With Natural Gravel I.PCC Grade M10 (ii)nominal mix 1:3:6. (Hand Mixing)

51.77

5607

-

... More
Providing and laying Reinforced Concrete pipe NP-3 on 1st Class Bedding of granular material in single row as per drawing and technical specification Clause 1106 (B) 1000 mm dia.

10

7787

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 B. With Natural Gravel II P.C.C Grade M15 Nominal mix 1:2.5:5

56.32

5935

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 B B. With Natural Gravel I)M-15 Nominal mix (1:2.5:5)

15.32

6278

-

... More
Plastering with cement mortar in Prop. (1:4), 15 mm thick on brick wall in Substructure as per drawing and technical specification Clause 613.4 &1204

43.02

146

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204,With Natural Gravel,P.C.C. grade M 20 (ii)Nominal mix 1:2:4 (Hand mixed)

364.82

6582

-

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302

14.85

2608

-

... More
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301

182.25

3339

-

... More
(iii) PWD main road to Ram Prabash Chouhan house (Ph-1) of Arcuttipore TE Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

1675.78

169

-

... More
Excavation in soil in Hilly Area by mechanical means including cutting and rimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1

3253.9

106

-

... More
Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 (Manual method should be adopted where machines can not be deployed due to site condition)

274.5

137

-

... More
Construction of un-line Surface Drain of average cross section area 0.40 Sqm in soil to specific lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50m (avg. lead 25m) as per Technical Specification Clause 307) (A) Manual Means

150

73

-

... More
Construction of Sub grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300.2 with lead up to 1000m as per Technical Specification Clause 303.1 (I) Private land

438.91

339

-

... More
Construction of Granular Sub Base by providing well graded materials, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. Grading II Materials

421.69

2211

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 8-100 kN in stages to proper grade and Camber applying and brooming, stone screening / binding materials to fill up the required density grading etc... A. By Manual Means, (iii) WBM Gr-III

210.26

3908

-

... More
Providing and laying Interlocking Cement Conc. Block Pavement with M-40 grade of concrete blocks having thickness 80mm as per technical specification clause 1504 including carriage (inclusive edge restrains and carriage)

2803.5

1161

-

... More
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801. 600mm equilateral triangle

2

3933

-

... More
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801 600mm circular

2

5345

-

... More
Providing and fixing retro reflectorised cautionery, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting 1.5 mm thick supported on a mild steel angle iron post 75mmx 75mmx 8mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concreyte 450mmx450mmx600mm below ground level as per drawings and technical specification Clause 801 800mm x 600mm rectangular

1

7537

-

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

24845

-

... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications (Considering 80% length)

142.4

566

-

... More
Providing and laying of Boulder Apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301

435.75

2780

-

... More
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed.

24

2530

-

... More
Construction of Trapezodial C. C. Drain Excavation for Structures. Earth work in excavation fo structure as per drawing 7 technical specifacation Clause 305.1 incluiding setting out Costruction of shoring and bracing , removal of stumps and other deletirious of shoring and disposal up to a lead of 50m, dressing of side and bottom and back filling in trenches suitable mayerials.(up to 3m depth.)

508.9

127

-

... More
Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause 802,803,1202 & 1203.(A)With Natural Graval. Ii PCC Grade M10 (i)nominal mix-(1:3:6)

43.62

5607

-

... More
Plain/Reinforced cement concrete in sub stucture complete as per drawing and techinal specification clause 802,804,805,806,807 & 1204 RCC.( A) with Natural Gravel. (ii) PCC M20, (i) Nominal Mix (1:2:4)

305.34

6582

-

... More
Construction of 600mm dia HP (NP3) Single opening (2 nos) Excavation for structures. Earth work in excavation for structureas as per drawing and technical specification Cl;305.1, including setting out, construction of shoring and bracing,removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and back filling in tranches with excavated suitable materials. Ordinary soil (i)Up to 3.00m depth.

16.6

127

-

... More
Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause802,803,1202,&1203 B. With Natural Gravel ( PCC Grade M10 )(I)nominal mix 1:3:6.

5.8

5607

-

... More
Brick masonary work in cement mortar 1:3 in foundation complete excluding pointing and plastaring as per drawing and technical specification Cl.600, 1202 &1203 II Brick Masonry 1:4 cement morter

16.26

7450

-

... More
Providing & laying reinforced cement concrete pipe NP3 as per designed in single row for culvert on 1 st class beddting of granular materials including fixing of collars with cement mortor 1:2 asper CL No. 1106. 600mm dia

15

3272

-

... More
Plastering with Cement Morter (1:4), 15mm thick on brick work in sub structure as per drawing & technical specification.

33.52

146

-

... More
Construction of 1000mm dia HP (NP3) Single opening (1 no) Excavation for structures. Earth work in excavation for structureas as per drawing and technical specification Cl;305.1, including setting out, construction of shoring and bracing,removal of stumps and other deleterious materials and disposal upto a lead of 50 m, dressing of sides and bottom and back filling in tranches with excavated suitable materials. Ordinary soil (i)Up to 3.00m depth.

18.64

127

-

... More
Providing Concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification Clause802,803,1202,&1203 B. With Natural Gravel ( PCC Grade M10 )(I)nominal mix 1:3:6.

4.83

5607

-

... More
Brick masonary work in cement mortar 1:3 in foundation complete excluding pointing and plastaring as per drawing and technical specification Cl.600, 1202 &1203 II Brick Masonry 1:4 cement morter

18.47

7450

-

... More
Providing & laying reinforced cement concrete pipe NP3 as per designed in single row for culvert on 1 st class beddting of granular materials including fixing of collars with cement mortor 1:2 asper CL No. 1106. 600mm dia

7.5

7787

-

... More
Plastering with Cement Morter (1:4), 15mm thick on brick work in sub structure as per drawing & technical specification.

25.84

146

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.