Public Works Roads Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Public Works Roads Department - PWRD Tender

Civil And Construction
Bridge Construction
Eprocure
Opening Date12 Apr 2023
Closing DateCancelled
Tender Amount₹ 42,73,22,900 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Pile load test on single vertical pile in accordance with IS:2911(Part-IV). a). Initial load test.

750

-

-

... More
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including shuttering formwork. II. With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. E. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump (For Stair Case)

38.4

-

-

... More
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. C. RCC Grade M30 Case II. Using Batching Plant, Transit Mixer and Concrete Pump

716.45

-

-

... More
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)

198.73

-

-

... More
Providing steel liner 8mm thick for steining of wells/pile including fabricating upto full length and setting out as per detailed drawing. (rate as per Assam PWD's approved rate)

138.76

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC Grade M25 (a) Height upto 5m Case-II. With Batching Plant, Transit Mixer and Concrete Pump for Stair Case

80.36

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC Grade M25 (b) Height 5m to 10m Case-II. With Batching Plant, Transit Mixer and Concrete Pump for Stair Case

5.59

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (a) Height upto 5m. Case-II. With Batching Plant, Transit Mixer and Concrete Pump

121.89

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (b) Height 5m to 10m Case-II. With Batching Plant, Transit Mixer and Concrete Pump

431.81

-

-

... More
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications. a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)

77

-

-

... More
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications.

1200

-

-

... More
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45 (ii)for I-beam & Slab including launching of precast girders by launching truss upto 40m span (b) Height 5m to 10m.

213.72

-

-

... More
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel Jindal panther steel/ Shyam steel or equivalent)

28.79

-

-

... More
Structural Steel Built up girder (BUG) Providing and launching Steel Truss of Structural steel BUG Super Structure including painting complete as per as per drawing and technical specifications under Section 1900 of MOST.)

451.05

-

-

... More
Provision of an reinforcrd cement concrete crash barrier at edges of bridge constructed with M40 grade of concrete with Hysd reinforcement conforming to IRC 21and dowel bars 25 mm dia 450 mm long at expansion jointfilled with pre - moulded Asphalt fillar board,keyed to the structure on which it is built and installed as per design given in the enclosure to MoSRT&H circular No RW/NH-33022/1/94-Do III dated 24th June 1994 as per dimention in the approved drawing and at location directed by the engineer - , all as specified.

126.96

-

-

... More
Drainage Spouts complete as per drawing and Technical specification

54

-

-

... More
PVC Pipe 150mm Dia

594

-

-

... More
Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity

685.58

-

-

... More
Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. Normal Bituminous surface

685.58

-

-

... More
Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )(Including cost of testing of materials at site and laboratory as directed by the deptt.) I. With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification) A. with 60/70 or VG-30 grade bitumen (ii) for Grading II (13 mm nominal size)

27.42

-

-

... More
Mastic Asphalt Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500- 29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.

685.58

-

-

... More
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70mm, complete as per approved drawings and standard specifications to be installed by the mnufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.

24

-

-

... More
Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification

126.96

-

-

... More
Providing, fitting and fixing Hand railing including MS Plat Base Plat Pipe complete as per drawing and Technical Specification. Over crash barrier.

126.96

-

-

... More
Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (A) For Plain surface

335.17

-

-

... More
Viaduct Portion : Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil B. Mechanical Means (I) without dewatering (i) Depth upto 3 m

3168.14

-

-

... More
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. A. PCC Grade M15

99.48

-

-

... More
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999 (Pile diameter-1200 mm)

2244

-

-

... More
Pile load test on single vertical pile in accordance with IS:2911(Part-IV). a). Routine load test (2 Nos of test).

900

-

-

... More
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including shuttering formwork. II. With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. E. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump for Approach & Suspended Slab Wall

11.12

-

-

... More
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. C. RCC Grade M30 Case II. Using Batching Plant, Transit Mixer and Concrete Pump

1729.63

-

-

... More
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)

572.17

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC Grade M25 (a) Height upto 5m Case-II. With Batching Plant, Transit Mixer and Concrete Pump

8.89

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC Grade M25 (b) Height 5m to 10m Case-II. With Batching Plant, Transit Mixer and Concrete Pump

19.68

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (a) Height upto 5m. Case-II. With Batching Plant, Transit Mixer and Concrete Pump

288.1

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. H. RCC Grade M35 (b) Height 5m to 10m Case-II. With Batching Plant, Transit Mixer and Concrete Pump

857.11

-

-

... More
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications. a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)

141.16

-

-

... More
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete asper drawing and approved technical specifications.

6600

-

-

... More
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (P) With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. PSC Grade M-45 (ii)for I-beam & Slab including launching of precast girders by launching truss upto 40m span (b) Height 5m to 10m.

2865.25

-

-

... More
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel Jindal panther steel/ Shyam steel or equivalent)

378.65

-

-

... More
High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications.

26.95

-

-

... More
Provision of an reinforcrd cement concrete crash barrier at edges of bridge constructed with M40 grade of concrete with Hysd reinforcement conforming to IRC 21and dowel bars 25 mm dia 450 mm long at expansion jointfilled with pre - moulded Asphalt fillar board,keyed to the structure on which it is built and installed as per design given in the enclosure to MoSRT&H circular No RW/NH-33022/1/94-Do III dated 24th June 1994 as per dimention in the approved drawing and at location directed by the engineer - , all as specified.

610.04

-

-

... More
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.

1830.13

-

-

... More
Reinforced cement concrete Approach slab (M35) including reinforcement and formwork complete as per drawing and Technical specification. A) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/SAIL/Esser Steel) Jindal panther steel/Shyam steel or equivalent.

43.74

-

-

... More
Drainage Spouts complete as per drawing and Technical specification

236

-

-

... More
PVC Pipe 150mm Dia

2596

-

-

... More
Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity

3202.72

-

-

... More
Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. Normal Bituminous surface

3202.72

-

-

... More
Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )(Including cost of testing of materials at site and laboratory as directed by the deptt.) I. With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification) A. with 60/70 or VG-30 grade bitumen (ii) for Grading II (13 mm nominal size)

128.11

-

-

... More
Mastic Asphalt Providing and laying 12 mm thick mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade bitumen meeting the requirements given in table 500- 29, prepared by using mastic cooker and laid to required level and slope aftering cleaning the surface, including providing antiskid surface with bitumen pre coated fine grained hard stone shipping of 9.5mm nominal size at the rate of .005 cum per 10sqm and at approximate spaciong of 10cm center to center in both directions, pressed into surfaces when temperature of the surfaces not less than 100 degC. , protuding 1mm to 4mm over mastic surfaces, all complete as per clause 515.

3202.72

-

-

... More
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70mm, complete as per approved drawings and standard specifications to be installed by the mnufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.

60.75

-

-

... More
Painting on concrete surface(Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (A) For Plain surface for Crash Barrier & Kerb.

1856.65

-

-

... More
Painting on concrete surface(Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) (B) RCC Railling

1830.13

-

-

... More
RE Wall : Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. III. Earth work including excavation, backfilling, grading and compaction with selected backfill soil in layers in Reinforced Earth works as per Technical specification and drawings.

44.21

-

-

... More
Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. IV. Construction of PCC strips level footing (35cm x 15cm) in M-15 grade concrete complete as per technical specification and drawing.

654.98

-

-

... More
Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. I. 18mm thick, M-35 grade RCC Facing elements of shape and size as per design and drawing with bearing pads, joint fillers, tie strips, fastener and all accessories and consumable complete.

2711.3

-

-

... More
Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. II. Assembling, joining and laying of reinforcing elements. B. With Reinforcing elements of Synthetic Geogrids

2711.3

-

-

... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A. Granular material

7620.15

-

-

... More
Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. V. Providing 600mm drainage bay behind RE wall with compacted granular material as per technical specification and drawing.

1315.87

-

-

... More
Reinforced Earth Retaining Wall: (Reinforced earth retaining walls including four main components of (a) Excavation for foundation, foundation concrete and cement concrete grooved seating in the foundation for facing elements (facia material), (b) Facia material and its placement, (c) Assembling, joining with facing elements and laying of the reinforcing elements and (d) Earth fill with granular material which is to be retained by the wall complete as per Technical Specification and Drawings. VI. Construction of crash barrier, parapet, coping beam with friction slab in M-30 grade concrete complete as per technical specification and drawing

620.98

-

-

... More
Sub Surface Drains with Perforated Pipe Construction of a narrow filter sub- surface drain consisting of porous or perforated pipe laid in narrow trench surrounded by a geotextile filter fabric, with a minimum of 450 mm overlap of fabric and installed as per clause 702.3 and 309.3.5 including excavation and backfilling .

620.98

-

-

... More
ROAD APPROACHES : Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202. I. By Manual Means. a. Bituminous courses

427.72

-

-

... More
Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202. I. By Manual Means. b. Granular courses

1069.3

-

-

... More
Dismantling Kerb Stone Dismantling kerb stones by manual means and disposal of dismantled material with all lifts and upto a lead of 1000 m as per Technical Specification Clause 202

25

-

-

... More
Dismantling of CI water pipe line Dismantling of CI water pipe line 600 mm dia including disposal with all lifts and lead upto 1000 m and stacking of serviceable material and unserviceable material separately under supervision of concerned department as per Technical Specification Clause 202.

6

-

-

... More
Removal of Cement Concrete pipe of Sewer Gutter Removal of cement concrete pipe of sewer gutter 1500 mm dia under the supervision of concerned department including disposal with all lifts and upto a lead of 1000 m and stacking of serviceable and unserviceable material separately but excluding earth excavation and dismantling of masonry works as per Technical Specification Clause 202.

25

-

-

... More
Embankment Construction with material obtained from Borrow pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto ead upto 1000 m as per Technical Specification Clause 301.5. (i) From Govt land

3427.97

-

-

... More
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (ii) From Govt land

1782.12

-

-

... More
Scarifying Existing Granular Surface Scarifying existing granular surface to a depth of 50mm and disposal of scarified material with a lift upto 3.0m and lead upto 1000m as per Technical specification Clause 301.4

2764.23

-

-

... More
Compacting Original Ground (i) Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.

414.63

-

-

... More
Granular Sub-Base with Coarse Graded Material ( Table:- 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (iii) for grading-III material

1184.86

-

-

... More
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead

1926.32

-

-

... More
Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity

9905.27

-

-

... More
Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. Normal Bituminous surface

19810.54

-

-

... More
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 507. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification. A. with 60/70 or VG-30 grade bitumen. (ii) for Grading-II (19mm nominal size)

622.85

-

-

... More
Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification. with 60/70 or VG-30 grade bitumen. (ii) for Grading-II (13mm nominal size)

230.5

-

-

... More
SERVICE ROAD : Embankment Construction with material obtained from Borrow pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto ead upto 1000 m as per Technical Specification Clause 301.5. (i) From Govt land

6375

-

-

... More
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (ii) From Govt land

4250

-

-

... More
Granular Sub-Base with Coarse Graded Material ( Table:- 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (iii) for grading-III material

1208.7

-

-

... More
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead

1887

-

-

... More
Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity

7548

-

-

... More
Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. Normal Bituminous surface

30192

-

-

... More
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 507. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification. A. with 60/70 or VG-30 grade bitumen. (ii) for Grading-II (19mm nominal size)

435.37

-

-

... More
Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification. with 60/70 or VG-30 grade bitumen. (ii) for Grading-II (13mm nominal size)

191.25

-

-

... More
Cast in Situ Cement Concrete M 20 Kerb with Channel Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade , sloped towards the kerb, kerb stone with channel laid with kerb laying machine,foundation concrete manually all complete as per clause 408.) B. Using Concrete Batching and Mixing Plant

1700

-

-

... More
RCC DRAIN : Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil B. Mechanical Means (I) without dewatering (i) Depth upto 3 m

4490.64

-

-

... More
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. A. PCC Grade M15

204

-

-

... More
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including shuttering formwork. II. With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. E. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump

714

-

-

... More
Reinforcement in Sub-Structure: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in Sub-Structure complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)

53.55

-

-

... More
TRAFFIC SIGN : Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. (i) 900mm equilateral triangle

2

-

-

... More
Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. (ii) 600mm equilateral triangle

2

-

-

... More
Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. (iii) 600mm circular

2

-

-

... More
Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. iv) 800mm x 600mm rectangular

2

-

-

... More
Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. v) 600mm x 450mm rectangular

2

-

-

... More
Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. vi) 600mm x 600mm square

2

-

-

... More
Retro reflectorised Traffic sign: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801. vii) 900mm side octagon

2

-

-

... More
Direction and place identification sign upto 0.9sqm size board. Providing and erecting direction and place identification retro-\reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

0.9

-

-

... More
Direction and place identification sign more than 0.9sqm Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

1.2

-

-

... More
Painting lines, Dashes, Arrows, etc. on Road in Two Coats on New Work. Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702

910

-

-

... More
Road Delineators Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming to IRC-79 and the drawings.

15

-

-

... More
Road Markers/Road Stud with Lense Reflector Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973

50

-

-

... More
Street Lighting (Providing and fixing lighting on bridges, mounted on steel hollow circular poles of standard specifications, 5 m high fixed on parapets with cement concrete, 20 m apart and fitted with sodium vapour lamp) (cement concrete to be measured and paid separately) For fixing in foothpath

25

-

-

... More
Lighting on Bridge (Providing and fixing lighting on bridges, mounted on steel hollow circular poles of standard specifications, 5m high fixed on parapets with cement concrete, 20m apart and fitted with soudium vapour lamp)

8

-

-

... More
Protective Work (RCC Retaining Wall): Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I. Ordinary soil B. Mechanical Means (I) without dewatering (i) Depth upto 3 m

1351.2

-

-

... More
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. A. PCC Grade M15

61.66

-

-

... More
Plain/Reinforced cement concrete, in foundation complete as per drawing and technical specification including steel shuttering formwork. II. With plasticiser ( Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999. E. RCC Grade M25. Case II. With Batching Plant, Transit Mixer and Concrete Pump

257.04

-

-

... More
Plain/Reinforced cement concrete, in sub structure complete as per drawing and technical specification and steel shuttering formwork . (P) With Plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasticiser (Masterplast PAE or equivalent and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. F. RCC Grade M25 (a) Height upto 5m Case-II. With Batching Plant, Transit Mixer and Concrete Pump

161.28

-

-

... More
Reinforcement in Sub-Structure: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in Sub-Structure complete as per drawing and technical specifications a) TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel)

41.83

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size toeards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification.

117.6

-

-

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.

45

-

-

... More
STRENGTHENING OF EXISTING ROAD : Prime coat Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502. (ii) Medium porosity

7500

-

-

... More
Providing and applying tack coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503. Normal Bituminous surface

22500

-

-

... More
Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site upto a lead of 1000 m laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504.

562.5

-

-

... More
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 507. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification. A. with 60/70 or VG-30 grade bitumen. (ii) for Grading-II (19mm nominal size)

375

-

-

... More
Bituminous Concrete Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (I) With hydrated lime/cement as filler ( refer table 500-9 of MoSRT&H specification. with 60/70 or VG-30 grade bitumen. (ii) for Grading-II (13mm nominal size)

225

-

-

... More
Carrying out of Proof Checking of all structural Design and Drawings by IIT Guwahati

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.