Public Works Roads Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 2,09,886Document Cost
₹ 2,099Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PWD_34035_13Bid Award Id
ViewTender No
CE/STBR/MMPNA/R_R/09/2023-24/1 Dated 29-09-2023Tender Authority
Public Works Roads Department ViewPurchaser Address
-Website
http://https://pwdroads.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and applying Epoxy based bonding agent Nitobond EP of Fosroc Chemicals or Masterbrace 1414 of BASF /Rearmbond EBA or equivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface with clean water for proper bonding of old and new concrete including formwork as specified and directed by the department complete.
99.76
-
-
Patching of damaged concrete surface with structural grade polymer modified reinstatement mortar to like Fosroc Renderoc S2 or equivalent at a thickness of 10 to 20 mm as per instruction of manufracturer and as approved by the engineer . The prepacked repair mortar should have a compressive strength 45 N/Sqmm, Flexture strength 8 N/ Sqmm at 28 Days
149.63
-
-
Concreting of the structure with free flow nonshrink cementitious microconcrete with Rendorec RG of Fosroc or equivalent after proper mixing with cleanwater including formwork followed by proper curing for 28 days as per manufacturer's specifications complete and as directed by the Department .
6.26
-
-
Repair of joint Grooves with Epoxy Mortar Repair of spalled joint grooves of contraction joints, longitudinal joints and expansion joints in concrete pavements using epoxy mortar or epoxy concrete)
99.76
-
-
Providing & fixing 16mm dia MS nozzles in a grid of 1m c/c up to the half of the thickness of the concrete structure.A grout slurry of neat cement & chloride free expanding grout cebex 100 of Fosroc Chemicals/ Mastergrout CPG-1 of Choksey Chemicals/ Armgrout additive of Myk arment/Masterflow 150 of BASF or equivalent @ 0.5% by weight of cement water cement ratio 0.35 to 0.40 and viscosity not more than 1.02 centipoise with grouting pressure till the refusal of injection grout Mastergrout CPG-1. The grouting operation pressure shall be 2Kg/sq.cm.Cutting the exposed nozzle after the grouting with a good cutter to make the surface free from the grouting pipes and to seal the gap with plugging compound Masterplug of Choksey Chemicals as per the specification and the direction of the department complete including formwork.
498.78
-
-
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy.
748.17
-
-
Sealing of crack / porous concrete with Epoxy Grout by injection through nipples complete as per clause 2803.1.
224.45
-
-
Providing and applying Dekguard E2000 or Masterseal 878 of BASF or Rearmcoat anticarb or equivalent a high performance anticarbonation protective coating system,over the primed surface using an airless sprey or roller at right angle to each other @ covarage 5 Sqm per litre per coat @200 micron wft/100 micron DFT with an intercoat period of minimum 12 hours @35ºC. The covarage per litre for two coat shall be 2.5 Sqm @200 micron DFT. The protective coating system should have Co2 diffusion resistance not less than 240 mm equivalent of air thickness and 60 cm equivalent of 30 N concrete along with water vapour transmission resistance of less than 1m (taywood method), the coating should have static crack accomodation of not less than 2mm (BRE) and adhesion greater than 1 N/sqmm as per BS 1881
498.78
-
-
Supplying and fixing of rebaring chemicals Fosroc LOKFIX E55 S-venylester chemical anchor grout or equivalent for various diameter of reinforcement bar at provided embedment depth as per manufracturer specification and instructions for use in concrete applications as directed by engineer in charge .a) 8 mm dia re-bar at 120mm depth
149.63
-
-
Supplying and fixing of rebaring chemicals Fosroc LOKFIX E55 S-venylester chemical anchor grout or equivalent for various diameter of reinforcement bar at provided embedment depth as per manufracturer specification and instructions for use in concrete applications as directed by engineer in charge .c) 12 mm dia re-bar at 180mm depth
74.82
-
-
Replacement of demaged mild steel railing
133.4
-
-
Providing, fitting, and fixing mild steel railing complete as drawing and tachnical specification
173.32
-
-
Dismantling of Cement Concrete Pavement (Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000metres ,stacking serviceable materials and unserviceable materials separately.)
14.01
-
-
Cement Concrete Pavement (A) Construction of un- reinforced, dowel jointed, plain cement concrete pavement over a prepared subbase with 43 grade cement @ 400 kg per cum, coarse and find aggregrate comforming to Is 383 maximum size coarse aggregrate not exceeding 25 mm, mix in a batching and mixing plan as per mixed design transported to the site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, contruction and longitudinal joints, joint filler separation membrane sealent primer sealent joint debonding strips duel bar tie rod, admixured as approved quring compopunding finishing two lines and grades as per drawing. (Including carriage upto initial lead of 5km from qwarry and carried of mix material upto 10 km initial lead from mixing plant)
14.01
-
-
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications (i) TMT CRS(Fe-500) reforcement bar
0.9
-
-
Non-destuctive testing with Ultrasonic Pulse Velocity Meter with data storage facility for detection of cracks, voids and other imperfections in Reinforced concrete structures and furnishing the findings thereof in proper comprehensible format , complete as directed by the department.
249
-
-
Conducting Concrete Core tests of 75mm diacores, on concrete stucture, as per stipulated procedures, for determination the equivalent cube compressive strength, concrete of the structures including preparation and furnishing the report showing the findings thereof in proper comprehensible format , complete as directed by the department.
25
-
-
Chipping of deteriorated concrete and removal of all loose & friable materials and fully exposing rusted reinforcement followed by proper cleaning and removing of rusts and other foreign materials using sand blasting/ emery cloths/ wire brush etc. including formwork as directed and specified by the department complete
500.92
-
-
Replacement of corroded reinforcement by cutting and welding new reinforcement of minimum 25mm dia. including lapping on both sides to the specified length as directed and as per relevant IS/IRC codes and cost of gas ,welding rods,higher charge of welding machines etc. including formwork as required.(Reinforcement to be measured and paid seperately)
125.23
-
-
Anticorrosive Treatment-'Supplying and applying two coats of zinc rich anti corrosive protective coating with nitozinc primer of fosroc /Floarm coat ZP or equivalent @0.20 Litre per sqm over thoroughly cleaned & prepared steel bar including formwork as directed and specified by the department complete.
50.09
-
-
Bonding between old and new concrete surface-Supplying and applying Epoxy based bonding agent Nitobond EP of Fosroc Chemicals or Masterbrace 1414 of BASF /Rearmbond EBA or equivalent @ 0.50 Lit pe sqm after totally saturating the cleaned concrete surface with clean water for proper bonding of old and new concrete including formwork as specified and directed by the department complete.
150.28
-
-
Patching of damaged concrete surface with structural grade polymer modified reinstatement mortar to like Fosroc Renderoc S2 or equivalent at a thickness of 10 to 20mm as per instructions of manufacturer and as approved by the Engineer.The prepacked repair mortar should have a compressive strength 45N/mm²,Flexture strength 8 N/mm² at 28 Days.
150.28
-
-
Concreting of the structure with free flow nonshrink cementitious microconcrete with Renderoc RG of Fosroc or equivalent after proper mixing with cleanwater including formwork followed by proper curing for 28 days as per manufacturer's specifications complete and as directed by the Department .
2.5
-
-
Repair of joint Grooves with Epoxy Mortar Repair of spalled joint grooves of contraction joints, longitudinal joints and expansion joints in concrete pavements using epoxy mortar or epoxy concrete
100.18
-
-
Providing & fixing 16mm dia MS nozzles in a grid of 1m c/c up to the half of the thickness of the concrete structure.A grout slurry of neat cement & chloride free expanding grout cebex 100 of Fosroc Chemicals or Mastergrout CPG-1 of Choksey Chemicals/ Armgrout additive of Myk arment or Masterflow 150 of BASF or equivalent @ 0.5% by weight of cement water cement ratio 0.35 to 0.40 and viscosity not more than 1.02 centipoise with grouting pressure till the refusal of injection grout. . The grouting operation pressure shall be 2Kg/sq.cm.Cutting the exposed nozzle after the grouting with a good cutter to make the surface free from the grouting pipes and to seal the gap with plugging compound Masterplug of Choksey Chemicals as per the specification and the direction of the department complete including formwork.
500
-
-
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy.
500
-
-
Sealing of crack / porous concrete with Epoxy Grout by injection through nipples complete as per clause 2803.1.
250.46
-
-
Structural Strengthening with carbon Fibre Wrapping: Patching in depression of concrete surface wherever necessary by laying epoxy putty , Nitocote VF of Fosroc Chemicals or MasterBrace ADH 2200 of Base or equivalent @ 1 Lit per sqm after proper surface preparation and proper scraping of concrete protrusion as specified and directed by the department complete including formwork .
241.9
-
-
Structural Strengthening with carbon Fibre Wrapping: Applying Nitowrap 410 saturant Fosroc Chemicals or MasterBrace 4500 saturant of BASF or equivalent with wet film thickness @ 250 microns (0.27Lit per sqm) over a coat of saturant epoxy primer Nitowrap 30 of Fosroc Chemicals or MasterBrace 3500 of BASF or equivalent @ 0.11Lit per sqm with brush followed by fixing carbon fibre composite system Nitowrap EP (CF) of Fosroc Chemicals or MasterBrace fibers (CF) of BASF or equivalent by pressing on the saturant and and impregnate the same by applying a final coat of Nitowrap 410 saturant Fosroc Chemicals or MasterBrace 4500 saturant of BASF or equivalent as specified and directed by the department complete including formwork.
241.9
-
-
Structural Strengthening with carbon Fibre Wrapping: Applying two coats of UV resistant coating Nitowrap 512 of Fosroc Chemicals or MasterProtect of BASF or equivalent over fibre system having wet film thickness of 100 micron @ 0.11Lit per sqm as specified and directed by the department complete including formwork.
241.9
-
-
Providing and applying Deckguard E 2000 or Masterseal 878 of BASf or equivalent a High Performance Anticarbonation Protective Coating System, over the prime surface using an airless spray or roller at right angles to each other @ coverage of 5 Sqm per litre per coat @ 200 microns wft / 100 microns DFT with an intercoat period of minimum 12 hrs @ 35ºC. The coverage per litre for 2 coats shall be 2.5 Sqm @ 200 microns DFT. The protective coating system should have CO2 diffusion resistance not less than 240mm equivalent of air thickness and 60cm equivalent of 30N concrete along with a water vapour transmission resistance of less than 1.0 metre (Taywood method), the coating should have static crack accommodation of not less than 2mm (BRE) and adhesion greater than 1.0 N/mm² as per BS 1881.
500.92
-
-
Supplying and fixing of rebaring chemicals Fosroc Lokfix E55 S-venylester chemical anchor grout or equivalent for various diameter of reinforcement bar at provided embedment depth as per manufracturer specification and instructions for use in concrete applications as directed by engineer in charge -- A)8 mm dia re-bar at 120mm depth
150
-
-
Supplying and fixing of rebaring chemicals Fosroc Lokfix E55 S-venylester chemical anchor grout or equivalent for various diameter of reinforcement bar at provided embedment depth as per manufracturer specification and instructions for use in concrete applications as directed by engineer in charge --C)12 mm dia re-bar at 180mm depth
75
-
-
Replacement of demaged mild steel railing
33.2
-
-
Providing, fitting and fixing mild steel railing complete as per drawing and Technical Specification
33.2
-
-
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications --Super Ductile (SD) TMT reinforcement bar of Fe-500 N/mm2
0.89
-
-
Non-destuctive testing with Ultrasonic Pulse Velocity Meter with data storage facility for detection of cracks, voids and other imperfections in Reinforced concrete structures and furnishing the findings thereof in proper comprehensible format , complete as directed by the department.
16
-
-
Conducting Concrete Core tests of 75mm diacores, on concrete stucture, as per stipulated procedures, for determination the equivalent cube compressive strength, concrete of the structures including preparation and furnishing the report showing the findings thereof in proper comprehensible format , complete as directed by the department.
4
-
-