Public Works Roads Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Public Works Roads Department - PWRD Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date1 Nov 2024
Closing Date30 Nov 2024
Tender Amount₹ 84,29,00,000 
Notes
Download

Costs

Summary

Improvement And Upgradation Of Dhodor Ali Nakachari To Khanikor

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lead and lifts and earth/sand filling in the depression/pit created as per Technical Specification Clause No. 201) d) Girth above 1800 mm

4

-

-

... More
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical Specification Clause No. 201 Girth from 300 mm to 600 mm

973

-

-

... More
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical Specification Clause No. 201 Girth from 600 mm to 900 mm

368

-

-

... More
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression/ pit as per Technical Specification Clause No. 201 Girth from 900 mm to 1800 mm

68

-

-

... More
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression/ pit as per Technical Specification Clause No. 201 Girth above 1800 mm

88

-

-

... More
Clearing and Grubbing Road Land: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of roots of trees cut earlier and disposal of unserviceable materials, stacking of serviceable material to be used as directed by Engineer as per Technical specification Clause No. 201)

31.33

-

-

... More
Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials to shown location, stacking serviceable and unserviceable materials separately, By mechanical means as per Technical specification Clause No. 202.) Bituminous courses

5197.99

-

-

... More
Dismantling of Flexible Pavements (Dismantling of flexible pavements and taking dismantled materials to construction camp, stacking serviceable and unserviceable materials separately for re-use as per additional Technical specification A-3, By mechanical means.as per drawing and Technical Specification) Granular courses

2662.72

-

-

... More
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lift and lead as per Technical specification Clause No. 202 Cement Concrete (PCC and RCC) (M-15 & M-20 and above)

735

-

-

... More
Dismantling of Structures (Dismantling Brick / Tile work / Stone Masonry in cement mortar including Pools and plants (T&P) and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lift and lead.)

18.36

-

-

... More
Removing all type of Hume pipe culverts above 900mm diametre including masonry works and stacking pipes at location shown by Engineer as per Technical Specification Clause No. 202

50

-

-

... More
Excavation in Soil using Hydraulic Excavator Tippers with disposal all lead and lifts. (Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, loading disposal of excavated earth with in all lifts and leads or for reuse if suitable for embankment/subgrade at other location). As per Technical Specification Clause No. 301.3

38898.78

-

-

... More
Excavation in Marshy Soil (Excavation for roadway in marshy soil with hydraulic excavator including cutting and loading in tippers and disposal with in all lifts and lead, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections, As per Technical Specification Clause No. 301.3)

392.92

-

-

... More
Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirements of Technical Specification Clause No. 305

184144.98

-

-

... More
Construction of Embankment with materials deposited from roadway cutting (Construction of embankment with approved Material Deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300-2 and as per Technical Specification Clause No. 305).

49460.63

-

-

... More
Compacting original ground supporting sub-grade (Loosening and Recompacting of the ground upto a level of 500 mm below the sub-grade level, watered, graded and compacted in layers to meet requirement of table 300-2 for sub-grade construction. As per Technical Specification Clause No. 305)

5875

-

-

... More
Construction of Subgrade/Median/Earthen Shoulders (Construction of sub-grade, Median and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 and Technical specification Clause No. 305 and 408)

155412.66

-

-

... More
Granular Sub-Base with Coarse Graded Material (Table: - 400- 1), (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause No. 401) For Grading V Material

53988.78

-

-

... More
Granular Sub-Base by reuse of excavated Coarse Graded Material from existing road (Table:- 400- 1) (Construction of granular sub-base by reuse of excavated non bituminous base and sub base roadway material from existing road , taking to plant area ,crushing to size and mixing suitable materials required to bring it to desired grading latter spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Clause No. 401 and Table 400-2 of Technical Specification) For Grading V Material

1863.91

-

-

... More
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate as per Technical specification including premixing the Material with water at OMC in mechanical mix plant, carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.as per Technical Specification Clause No. 406)

53246.18

-

-

... More
Prime Coat Providing and applying primer coat as per Technical Specification Clause No. 502 with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per spreading rate approved by Engineer.

207332.16

-

-

... More
Tack Coat Providing and applying tack coat with bitumen emulsion as per Technical Specification Clause No. 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.

207332.16

-

-

... More
Dense Bituminous Macadam Providing and laying dense bituminous macadam Grading II (19mm nominal aggregate size) using VG 30 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade and alignment, compacting to achieve the desired compaction and complete in all respects as per Technical specification Clause No. 505.

12439.92

-

-

... More
Bituminous Concrete Providing and laying bituminous concrete Grading I (13mm nominal aggregate size) using PMB 70 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, compacting to achieve the desired compaction and complete in all respects as per Technical specification Clause No. 501.2 .1 & Clause No. 507

8293.29

-

-

... More
Protection works Turfing with Sods (Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the engineer including preparation of ground, fetching of rods and watering) as per Technical specification Clause No. 307.

6175.77

-

-

... More
Drain Excavation in Soil for Structures using Hydraulic Excavator Tippers with disposal all lead and lifts. (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavated earth to the extent required and utilising the remaining earth locally for road work as per Clause No. 304 of Technical Specification)

3213

-

-

... More
Drain Plain cement Concrete in open foundation complete as per drawing & Technical Specification Clause No.1704.3 PCC grade M15

289

-

-

... More
Drain Reinforced cement Concrete in open foundation complete as per drawing & Technical Specification RCC grade M25 With Batching Plant, Transit Mixer and Concrete Pump

1351.5

-

-

... More
Drain Reinforcement in Drain: (Supplying, placing and fixing TMT High Strength Deformed Steel Bars conforming to IS:1786 Fe 500D Grade in drain complete as per drawing and Technical Specification Section 1600)

147.9

-

-

... More
Drain Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards draining face. Complete as per drawing and Technical specification Clause No. 2706

1700

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide Clause No. 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Technical specification Clause No. 801.3 90 cm equilateral triangle

142

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide Clause No. 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause No. 801.3 60 cm circular

8

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide Clause No. 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing 80 mm x 60 mm rectangular Clause No. 801.3

26

-

-

... More
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectrorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide Clause No. 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Technical specification Clause No. . 801.3 90 cm high octagon

32

-

-

... More
Retro-Reflectorised Traffic Signs Supplying and installation of Retro Reflectorized Indicators, 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorized panels at the top, buried or pressed into the ground and conforming to IRC-79, all complete as per Technical Specification and as directed by the Engineer-in-charge. One way hazard marker

7

-

-

... More
Retro-Reflectorised Traffic Signs Supplying and installation of Retro Reflectorized Indicators, 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorized panels at the top, buried or pressed into the ground and conforming to IRC-79, all complete as per Technical Specification and as directed by the Engineer-in-charge. Object hazard marker

92

-

-

... More
Retro-Reflectorised Traffic Signs Supplying and installation of Retro Reflectorized Indicators, 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorized panels at the top, buried or pressed into the ground and conforming to IRC-79, all complete as per Technical Specification and as directed by the Engineer-in-charge. Road way delineator

94

-

-

... More
Retro-Reflectorised Traffic Signs Supplying and installation of Retro Reflectorized Indicators, 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorized panels at the top, buried or pressed into the ground and conforming to IRC-79, all complete as per Technical Specification and as directed by the Engineer-in-charge. Chevron 600 x 450 mm

56

-

-

... More
Direction and Place Identification Signs with size more than 0.9 sqm size Board. Providing and erecting direction and place identification retro- reflectrorised sign as per IRC :67 made of high intensity grade sheeting vide Clause No. 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause No. 801.3

2.4

-

-

... More
Kilometre Stone: Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC:8, fixing in position including painting and printing etc.as per technical specification IRC: 8 Type Designs of Highway Kilometre Stone (Second revision) 5th kilometre stone (Precast)

8

-

-

... More
Kilometre Stone: Reinforced cement concrete M15 grade kilometre stone of standard design as per IRC:8, fixing in position including painting and printing etc.as per technical specification IRC: 8 Type Designs of Highway Kilometre Stone (Second revision) Ordinary Kilometre stone (Precast)

24

-

-

... More
Kilometre Stone: Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8, fixing in position including painting and printing etc.as per technical specification IRC: 8 Type Designs of Highway Kilometre Stone (Second revision) Hectometre stone (Precast)

68

-

-

... More
Overhead Signs of including Truss, Two Vertical Post, concrete foundation all complete Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectrorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in Technical specification Clause No. 802.2 and 802.3 and installed as per Technical specification Clause No. 802.6 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved drawing and plans and Technical Specification complete and Technical specification Clause No. 802

1

-

-

... More
Metal Beam Crash Barrier Type - A, “W” : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS : 1367 and IS : 1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x5 mm, 546 mm long complete as per Technical specification Clause No. 811.3 complete job as per approved drawings.

1440

-

-

... More
Flexible Crash Barrier, Wire Rope Safety Barrier (Providing and erecting a wire rope safety barrier with vertical posts of medium weight RS Joist (ISMB series) 100 mm x 75 mm (11.50 kg/m), 1.50 m long 0.85 m above ground and 0.65 m below ground level, split at the bottom for better grip , embeded in M-15 grade cement concrete 450mm X 450mm X 450mm, 1.50m centre to centre with 4 horizontal steel wire rope 40mm dia and anchored at terminal posts 15m apart. Terminal posts to be embeded in M15 grade cement concrete foundation 2400 X 450 X 900mm (Depth), strengthen by a strut of Rs joists 100X75mm. 2m long at 450 inclination and a tie 100 X 8mm, 1.50m long at the bottom, all embeded in foundation concrete as per approved design and drawing rate excluding excavation and cement concrete.) as per Clause No. 811.4

360

-

-

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including Reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes as per Technical specification Clause No. 803.4

8521

-

-

... More
Boundary pillar Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting as per Clause No. 807

200

-

-

... More
Pedestrian Guard Rail: Tubular Steel Railing on Medium Weight steel channel (ISMC series) 100 mm x 50 mm (Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 metres high above ground, 2 m centre to centre, complete as per approved drawings and Technical Specification Clause No. 809)

4700

-

-

... More
Road Stud with Lense Reflector Road Markers/Road Stud with Lense Reflector (Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973) and Technical specification Clause No. 804.

2895

-

-

... More
Supply, Installation, Testing and Commissioning of Made in India Semi Integrated Stand-Alone 65W Solar LED (W-LED) Street Lighting System proposed at Major & Minor Junction Location, Bus Bay & Bus Shelter Location and Major Bridge as per Drawing and Technical Specification of Solar Street Light (65W) LED BASED. The system efficacy of the 65W solar street light should be 160 lm/W (Lumen output ≥ 10400 lumens at @maximum power). The lighting system must be with MPPT Solar Charge Controller, 165 Wp Solar PV module, 12.8 V, 84Ah Li-Fe-Po4 battery with inbuilt BMS technology and automatic dusk to dawn operation with dimming including all necessary control electronics-inter connecting wires / cables and all mechanical hardware to be mounted on a 7m long hot dip galvanized Octagonal/Conical Pole made of HT Steel Grade. Pole base plate is 250x250x16mm, top & bottom dia are 70 & 158mm respectively, plate thickness 3mm along with 4 numbers of 750mm foundation bolt as per EN-8 Grade. Pole to be installed on a RCC foundation of M-20 Grade concrete.

26

-

-

... More
Painting two coats after filling the surface with synthetic enamel paint in all shades on new concrete surfaces as per ATS-2

1410

-

-

... More
Construction of R.C.C Bus shelter at Village Portion as per drawing and Technical Specification Clause No.12.6 of IRC SP 73:2018 "Manual of Specifications and Standards for Two Laning of Highways with Paved Shoulder (Second Revision)

26

-

-

... More
Supply and Installation of 300 mm Solar Blinker. LED - 216 Solar Panel 30 Watt Battery - 12 AH Fitting, Fixing and all complete Job.

7

-

-

... More
Box Culvert Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification Clause No. 304, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. (All depth)

8145.18

-

-

... More
Box Culvert Plain/Reinforced cement concrete, in foundation complete as per drawing and technical specification including steel shuttering formwork and Technical specification Section 2100 RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump

573.4

-

-

... More
Box Culvert Reinforced cement concrete, in sub structure complete as per drawing and technical specification Section.2200 and steel shuttering formwork RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump

550.39

-

-

... More
Box Culvert Furnishing and Placing Reinforced/ Prestressed cement concrete in superstructure as per drawing and Technical Specification’ Section 2300 including steel shuttering formwork. RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump

195.98

-

-

... More
Box Culvert Reinforcement in Foundation (Supplying, placing and fixing TMT High Strength Deformed Steel Bars conforming to IS:1786 Fe 500D Grade in Foundation complete as per drawing and Technical Specification Section 1600)

35.88

-

-

... More
Box Culvert Reinforcement in Sub Structure (Supplying, placing and fixing TMT High Strength Deformed Steel Bars conforming to IS:1786 Fe 500D Grade in Substructure complete as per drawing and Technical Specification Section 1600)

62.44

-

-

... More
Box Culvert Reinforcement in Super Structure (Supplying, placing and fixing TMT High Strength Deformed steel bars conforming to IS:1786 Fe 500D Grade in Super- structure complete as per drawing and technical specification Section 1600)

20.68

-

-

... More
Box Culvert Plain cement concrete, in foundation complete as per drawing and Technical specification section 2100 including steel shuttering formwork. PCC Grade M15

321.72

-

-

... More
Box Culvert Providing and laying of Geo composite material as a Filter media as per Technical Specification Section 700, material must satisfy the following property :- 1. Mass per unit area gm/m -710 minimum . 2. CBR Puncture Resistance (N)- 3000 minimum. 3. Tensile strength (Kn/m) -16 minimum. 4. Hydraulic gradient i = 1 at 100 kPa pressure 5. Hydraulic gradient i = 1 at 200 kPa pressure. Drainage core :- Sets of parallel ribs overlaid and integrally connected having rhomboidal mesh opening. Raw material - High density polyethylene stabilised by Carbon black , black carbon with three core.

2204.96

-

-

... More
Box Culvert Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards draining face. Complete as per drawing and Technical specification Clause No. 2706

688

-

-

... More
Box Culvert Sand Filling in foundation trenches as per drawing & MoRT&H technical specification Clause No. 304.

862.93

-

-

... More
Box Culvert Plain cement concrete, in foundation complete as per drawing and Technical specification 2507 including steel shuttering formwork. Curtain wall/flexible Apron PCC Grade M20

711.06

-

-

... More
Box Culvert Providing and laying Stone/Boulder apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification Section 2500

1435.57

-

-

... More
Box Culvert Provision of reinforced cement concrete crash barrier (New Jersey Type) on structure, constructed with M - 40 grade concrete and with High Strength Deformed Steel bars reinforcement Fe 500D grade conforming to IRC:21, including 50mm dia railing with fixtures and installed as per approved drawings and at locations as directed by the Engineer. As per Technical specification Clause No. 2703.3 and Clause No. No. 811.2 & Clause No.109.6. of IRC: 5 Standard Specifications and Code of Practice for Road Bridges Section- I General Features of Design

164.32

-

-

... More
Box Culvert Mastic Asphalt (Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in Table 500-39 of Technical Specification ( binder having penetration as (15+/- 5) at 250C), prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing anti-skid surface with bitumen pre coated fine grained hard stone ships of 13.2mm nominal size at the rate of .005cum per 10 sqm. and at an approximate spacing of 10 cm centre to centre in both directions, pressed into surface when the temperature of surfaces more than 100C, protruding 1mm to 4mm over mastic surface, all complete as per Technical specification Clause No. 516 of technical Specification.

611.52

-

-

... More
Box Culvert Bituminous Concrete Providing and laying bituminous concrete Grading I (13mm nominal aggregate size) using PMB 70 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, compacting to achieve the desired compaction and complete in all respects as per Technical specification Clause No. 501.2 .1 and Clause No. 507

24.46

-

-

... More
Box Culvert Tack Coat Providing and applying tack coat with bitumen emulsion as per Technical Specification Clause No. 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.

611.52

-

-

... More
Minor Bridge Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification Clause No. 304, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) (All depth)

2633.81

-

-

... More
Minor Bridge Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification Clause No. 2100 and including steel shuttering formwork. PCC grade M15

65.13

-

-

... More
Minor Bridge Reinforced cement concrete in Substructure complete as per drawings and Technical Specification section 2200 and IRC :112-2020 (Code of Practice for Concrete Road Bridges) With Batching Plant, Transit Mixer and Concrete Pump R.C.C. grade M-35 (All height)

109.43

-

-

... More
Minor Bridge Reinforced cement concrete in Substructure complete as per drawings and Technical Specification section 2200 and IRC :112-2020 (Code of Practice for Concrete Road Bridges) With Batching Plant, Transit Mixer and Concrete Pump R.C.C. grade M-30 (All height)

145.97

-

-

... More
Minor Bridge Supplying, placing and fixing in position true to line and level POT Bearings conforming to IRC: 83 (Part-III) -2018 Section: IX and Clause No. 2006 complete including all accessories as per drawing and Technical Specification.

1600

-

-

... More
Minor Bridge Supplying, fitting and fixing in position true to line and level Elastomeric bearing conforming to IRC 83 (Part II)-2018 Section: IX and Clause No. 2005 of Technical Specification complete including all accessories as per drawing and Technical Specification.

51960

-

-

... More
Minor Bridge Supplying, fitting and fixing in position true and level of Metallic Guide Bearing conforming to IRC 83 (Part III)-2018 Section: IX - including all accessories as per drawing and Technical Specification.

325

-

-

... More
Minor Bridge Supplying, fitting and fixing in position true and level of Pin Bearing conforming to IRC 83 (Part III) -2018 Section: IX including all accessories as per drawing and Technical Specification.

3900

-

-

... More
Minor Bridge Reinforced cement concrete, in Super structure complete as per drawing and technical specification Clause No. 2300 and IRC :112-2020 (Code of Practice for Concrete Road Bridges) and steel shuttering formwork; PSC M-40 grade using batching plant and concrete pump (All height)

83.41

-

-

... More
Minor Bridge Reinforced cement concrete, in Super structure complete as per drawing and technical specification Clause No 2300 and IRC :112-2020 (Code of Practice for Concrete Road Bridges) and steel shuttering formwork; PSC M-45 grade using batching plant and concrete pump (All height)

163.22

-

-

... More
Minor Bridge PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification Clause No. 2704

28.2

-

-

... More
Minor Bridge Reinforced cement concrete Approach slab M30 Grade including reinforcement and formwork complete as per drawing and Technical specification Clause No. 2704

73.84

-

-

... More
Minor Bridge Providing and laying of an Strip seal expansion joint complete as per drawing and Technical specification for road & bridge works Clause No. 2606 and Clause No. 2610 of technical specification

48

-

-

... More
Minor Bridge Drainage Spouts complete as per drawing and Technical specification Clause No. 2705

22

-

-

... More
Minor Bridge Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards draining face. Complete as per drawing and Technical specification Clause No. 2706

318

-

-

... More
Minor Bridge Reinforcement in Foundation (Supplying, placing and fixing TMT High Strength Deformed Steel Bars conforming to IS:1786 Fe 500D Grade in Foundation complete as per drawing and Technical Specification Section 1600)

5.34

-

-

... More
Minor Bridge Reinforcement in Sub Structure (Supplying, placing and fixing TMT High Strength Deformed Steel Bars conforming to IS:1786 Fe 500D Grade in Substructure complete as per drawing and Technical Specification Section 1600)

27.08

-

-

... More
Minor Bridge Reinforcement in Super Structure (Supplying, placing and fixing TMT High Strength Deformed steel bars conforming to IS:1786 Fe 500D Grade in Super- structure complete as per drawing and technical specification Section 1600)

69.68

-

-

... More
Minor Bridge Supplying, placing and fixing of Uncoated stress relieved low relaxation seven ply strand conforming to IS 14268 including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specification Section1800 and IRC :112-2020 (Code of Practice for Concrete Road Bridges)

8.01

-

-

... More
Minor Bridge Provision of reinforced cement concrete crash barrier (New Jersey Type) on structure, constructed with M - 40 grade concrete and with High Strength Deformed Steel bars reinforcement Fe 500D grade conforming to IRC:112, including 50mm dia railing with fixtures and installed as per approved drawings and at locations as directed by the Engineer. As per Technical specification Clause No. 2703.3 and Clause No.811.2 & Clause No.109.6. of IRC: 5 Standard Specifications and Code of Practice for Road Bridges Section- I General Features of Design

145.6

-

-

... More
Minor Bridge Painting two coats after filling the surface with synthetic enamel paint in all shades on new concrete surfaces as per ATS-2

361.4

-

-

... More
Minor Bridge Mastic Asphalt (Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in Table 500-39 of Technical Specification ( binder having penetration as (15+/- 5) at 250C), prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing anti-skid surface with bitumen pre coated fine grained hard stone ships of 13.2mm nominal size at the rate of .005cum per 10 sqm. and at an approximate spacing of 10 cm centre to centre in both directions, pressed into surface when the temperature of surfaces more than 100C, protruding 1mm to 4mm over mastic surface, all complete as per Technical specification Clause No. 516.

654.2

-

-

... More
Minor Bridge Bituminous Concrete Providing and laying bituminous concrete complete as per drawing and Technical Specification Clause No.501.2.1 and Clause No. 507. (i) with PMB-70 Grade Bitumen (i) for grading 2 (13.2mm nominal size)

46.32

-

-

... More
Minor Bridge Tack Coat Providing and applying tack coat with bitumen emulsion as per Technical Specification Clause No. 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.

611.52

-

-

... More
Minor Bridge Back filling behind abutment, wing wall and return wall complete as per drawing, IRC and Technical Specification Clause No.-305

1507.45

-

-

... More
Minor Bridge Providing and laying of Geo composite material as a Filter media as per Technical Specification Section 700 material must satisfy the following property :- 1. Mass per unit area gm/m -710 minimum . 2. CBR Puncture Resistance (N)- 3000 minimum. 3. Tensile strength (Kn/m) -16 minimum. 4.Hydraulic gradient i = 1 at 100 kPa pressure 5. Hydraulic gradient i = 1 at 200 kPa pressure. Drainage core :- Sets of parallel ribs overlaid and integrally connected having rhomboidal mesh opening. Raw material - High density polyethylene stabilised by Carbon black , black carbon with three core.

442.5

-

-

... More
Minor Bridge Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification.

69.6

-

-

... More
Minor Bridge Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.

69.6

-

-

... More
Minor Bridge Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and Technical Specification.

74

-

-

... More
Minor Bridge Providing and filling joint sealing compound as per drawings and Technical Specification with coarse sand and 6% bitumen by weight

50

-

-

... More
Minor Bridge Providing and laying Stone/Boulder Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical Specification Section 2500

161.98

-

-

... More
Minor Bridge Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification.

107.99

-

-

... More
Minor Bridge Providing and laying Plain cement concrete mechanically mixed and compacted, including centring and shuttering all complete as per Clause No. 1500, 1700 & 2100 drawings and Technical Specification and as directed by the Engineer-in-charge. PCC M15 grade (Toe wall)

86.5

-

-

... More
Minor Bridge Furnishing and Placing Reinforced/ Prestressed cement concrete in Superstructure including all lead and lifts as per drawing and Technical Specification Section 2300 and IRC :112-2020 (Code of Practice for Concrete Road Bridges) Sesmic Arrester and Pedestal PSC Grade M-45, Using Batching plant

12.07

-

-

... More
Minor Bridge Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure including all lead and lifts as per drawing and Technical Specification Section 2300 and IRC :112-2020 (Code of Practice for Concrete Road Bridges) RCC M35

170.04

-

-

... More
Minor Bridge Plain cement concrete, in foundation complete as per drawing and Technical specification Clause No. 2507 including steel shuttering formwork. Curtain wall/flexible Apron PCC Grade M20

134.08

-

-

... More
Minor Bridge Providing and laying Stone/Boulder apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification Section 2500

630.26

-

-

... More
Minor Bridge Granular Sub-Base with Coarse Graded Material (Table: - 400- 1), (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical Specification Clause No. 401) For Grading V Material

54.16

-

-

... More
Minor Bridge Rigid Apron: -Providing and laying Flooring complete as per drawing and Technical Specification Section 2500 laid over cement concrete bedding. Rubble stone laid in cement mortar 1:3

58.48

-

-

... More
Reparing & Rehabilitation Removal of existing cement concrete wearing coat including its disposal complete as per Technical specification without causing any detrimental effect to any part of the bridge structure and removal of dismantled material with all lifts and lead upto 1000m. (Thickness 75 mm.)

688.94

-

-

... More
Reparing & Rehabilitation Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres. II By Mechanical Means for Items No. 202 (b) & (c) B. Prestressed / Reinforced cement concrete grade M20 & above

5.4

-

-

... More
Reparing & Rehabilitation Eproxy bonding of new concrete to old concrete as per technical specification' as per Technical specification Clause No. 2805

15.62

-

-

... More
Reparing & Rehabilitation Providing, placing and fixing in position Chemical rebar fastners (of M/s Hilti or M/s Sika or approved equivalent conforming to Europian standard CSTB/ETA and Civil Aid standard) of vaious diameters in Piers, Pier caps, including drilling holes of specified size and depth, cleaning holes, placing chemicals inside the holes and fixing reinforcing bars as per specifications of the chemical rebar supplier, and under supervision of the authorized representative of the supplier and conducting pull-out test of atleast 5% of total nos. of chemical re-ba fastners (cost of reinforcing bars to be paid seperately) all complete as per specification as directed by the department. 12 mm dia re-bar fastners.

100

-

-

... More
Reparing & Rehabilitation Labour for Lifting of super structure span by jacking up from below i.e. by placing the jacks on pier/abutment caps for span length of 30m. (Cost of bearing to be paid extra) (Rectification of Bearings as per Technical Specification Clause No. 2810) Lifting from the pier cap

4

-

-

... More
Reparing & Rehabilitation Replacement of Expansion Joints complete as per drawings and technical specification'

33.6

-

-

... More
Reparing & Rehabilitation Reinforced cement concrete in Substructure complete as per drawing and technical specification Section 1700 RCC M40 (For Pedestal)

6.31

-

-

... More
Reparing & Rehabilitation Reinforcement in Sub Structure (Supplying, placing and fixing TMT High Strength Deformed Steel Bars conforming to IS:1786 Fe 500D Grade in Substructure complete as per drawing and Technical Specification Section 1600)

0.95

-

-

... More
Reparing & Rehabilitation Supplying, fitting and fixing in position true to line and level Elastomeric bearing conforming to IRC 83-2018 (Part II) Section: IX including accessories conforming to Technical Specification complete

580608

-

-

... More
Reparing & Rehabilitation Providing and laying of a Strip seal expansion joint conforming to Clause No. 2606 of Technical Specification catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer’s instruction for installation.

33.6

-

-

... More
Reparing & Rehabilitation Bituminous Concrete Providing and laying bituminous concrete complete as per drawing and Technical Specification Clause No.501.2.1 and Clause No. 507 (i) with PMB-70 Grade Bitumen (i) for grading 2 (13.2mm nominal size)

27.56

-

-

... More
Reparing & Rehabilitation Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-39, (binder having penetration as (15+/-5) at 250C),prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing antiskid surface with bitumen precoated fine-grained hard stone chipping of 13.2 mm nominal size at the rate of 0.005cum per 10 sqm and at an approximate spacing of 10 cm center to center in both directions, pressed into surface when the temperature of surfaces more than 100C, protruding 1 mm to 4 mm over mastic surface, all complete as per Clause No. 516

688.94

-

-

... More
Reparing & Rehabilitation Providing and applying tack coat with bitumen emulsion as per Technical Specification Clause No. 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.

688.94

-

-

... More
Reparing & Rehabilitation Painting on concrete surface (Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. ) For RCC Railing

186.2

-

-

... More
Environment Management Cost Ambient air quality monitoring along the project road for particulate matter (PM2.5 and PM10), sulphur dioxide (SO2), oxides of nitrogen (NOX); and carbon monoxides (CO) using standard analysis technique in accordance with the National Ambient Air Quality Standards formulated by MoEF&CC and the World Bank (IFC) Air Quality. Near all hot mix plant locations approved by the Engineer as per Technical Specification clause no 111

5

-

-

... More
Environment Management Cost Ambient air quality monitoring along the project road for particulate matter (PM2.5 and PM10), sulphur dioxide (SO2), oxides of nitrogen (NOX); and carbon monoxides (CO) using standard analysis technique in accordance with the National Ambient Air Quality Standards formulated by MoEF&CC and the World Bank (IFC) Air Quality. Construction sites near sensitive locations as per Technical Specification clause no 111

5

-

-

... More
Environment Management Cost Ambient air quality monitoring along the project road for particulate matter (PM2.5 and PM10), sulphur dioxide (SO2), oxides of nitrogen (NOX); and carbon monoxides (CO) using standard analysis technique in accordance with the National Ambient Air Quality Standards formulated by MoEF&CC and the World Bank (IFC) Air Quality. At 1 location during operation stage where monitoring had been done during construction stage as per Technical Specification clause no 111

5

-

-

... More
Environment Management Cost Sound Pressure Level (SPL) measurements along the project road using standard analysis technique in accordance with the National Ambient Noise Standard in respect of noise formulated by MoEF&CC and the World Bank (IFC) Noise Level Guidelines. At equipment yards/ Hot mix plants/ Construction Camps as per Technical specification clause no 111

5

-

-

... More
Environment Management Cost Sound Pressure Level (SPL) measurements along the project road using standard analysis technique in accordance with the National Ambient Noise Standard in respect of noise formulated by MoEF&CC and the World Bank (IFC) Noise Level Guidelines. Near known nesting sites - as directed by the Engineer as per Technical specification clause no 111

5

-

-

... More
Environment Management Cost Sound Pressure Level (SPL) measurements along the project road using standard analysis technique in accordance with the National Ambient Noise Standard in respect of noise formulated by MoEF&CC and the World Bank (IFC) Noise Level Guidelines. During Operation Stage as directed by the Engineer as per Technical specification clause no.111

5

-

-

... More
Environment Management Cost Water Quality Testing for parametres as per IS: 10500-2012 along the road in accordance with CPCB norms Surface Water Quality testing during Construction Stage as per Technical specification clause no 111

3

-

-

... More
Environment Management Cost Water Quality Testing for parametres as per IS: 10500-2012 along the road in accordance with CPCB norms Discharge Water Quality testing during Operation Stage as per Technical specification clause no 111

3

-

-

... More
Environment Management Cost Soil Quality Testing along the project road in accordance with CPCB norms During Construction stage at productive agricultural lands abutting traffic detours and traffic diversions, to be identified by the Engineer as per Technical specification clause no 111

3

-

-

... More
Environment Management Cost Soil Quality Testing along the project road in accordance with CPCB norms During Operation stage at accident/spill locations involving bulk transport carrying hazardous material. as per Technical specification clause no. 111

3

-

-

... More
Environment Management Cost Turfing with Sods (Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the engineer including preparation of ground, fetching of rods and watering) 5 m width turfing on outer side of ponds

1500

-

-

... More
Environment Management Cost Surface Drains in Soil (Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions to the requirement of Technical specification clause 301 and 309. Excavated material to be used in embankment within a lead of 50m (Average lead 25m) Construction of surface drains on outer side of ponds

130

-

-

... More
Environment Management Cost Oil interceptors at parking/ servicing of construction vehicles as per Technical specification clause no 111

1

-

-

... More
Environment Management Cost Provision of Noise barrier at sensitive areas like schools and hospitals. The noise barriers of hollow brick wall/ reinforced concrete panels with height of 3.5m. (School, Health care centre) as per clause no 111

100

-

-

... More
Provisional Sum for Road Facilities and Amenities

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.