Public Works Roads Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 4,00,000Document Cost
₹ 4,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWD_39700_60Tender No
CE/MAINT/RIDF-XXX/TE/01/24-25Tender Authority
Public Works Roads Department ViewPurchaser Address
-Website
http://https://pwdroads.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Construction of embankment with approved materials obtained from borrow pits with a lift upto 1.5m, transporting to site, spreading, grading to required slope and compaction to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000m as per Technical Specification Clause 301.5.
(i) Private Land
7665.46
-
258.21
Compacting original ground supporting subgrade
Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.
2469
-
36.16
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
(i) Private Land
1255.13
-
339.68
Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC,and compacting with vibratory roller to achieve the desired density,complete as per cl. 401( with an initial lead of 5 Km.) (i) for Gr. II material. (1) FOR GHURAJAN T. E.
539.33
-
2541.88
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.( with an initial lead of 5 Km.)( i) for Gr. II material. (2) FOR RAIDANG T. E.
515
-
2304.82
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness , hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill up the interstices of coarse aggregate, watering and compaction to the required density as per Technical Specification Clause 405. Gr.III. (1) FOR GHURAJAN T. E.
323.6
-
4384.61
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness , hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill up the interstices of coarse aggregate, watering and compaction to the required density as per Technical Specification Clause 405. Gr.III. (2) FOR RAIDANG T. E.
309
-
4116.06
Inter locking concrete Block pavement
(A) Interlocking pavement block
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage.
(a) Including Edge block/ Edge restraints
(1) FOR GHURAJAN T. E.
4314.6
-
1161.07
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage.
(b) Excluding Edge block/ Edge restraints
(2) FOR RAIDANG T. E.
4120
-
941.4
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork.
(D) PCC Grade M25 (i) Using Concrete Mixer
174
-
7273.81
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand). ii) 60cm equilateral traingle
22
-
3933.19
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand). ii) 60cm Circular
6
-
5345.8
Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand). iv) 80cmm x 60 cm rectangular
6
-
7537.1
Direction and Place identification sign upto 0.9 sqm size board : Providing and erecting Direction and Place identification sign upto 0.9 sqm size board reto Reflectorised sign as per IRC: 67 madeof high intensity encapsulated lense type reflected sheeting vide cl.801.3, fixed over aluminium sheeeting ...... as per approved drawing and sign (All steel work must be Tata/ SAIL or any other approved brand.)
3.6
-
13899.23
Cross Drainage works : (H.P. Culvert 1000MM Dia NP-3, L = 7.50M)
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material..
I. In ordinary soil. Upto 3 m depth
93.45
-
127.69
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 802, 803, 1202 & 1203.
A. With crushed stone.
PCC Grade M10, Nominal Mix 1: 3: 6
9.24
-
6036.57
Bedding of pipe
(ii)Type B (First Class) Bedding Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii) Granular Material
11.99
-
1558.04
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (B) 1000 mm dia
37.5
-
7787.85
Filling in foundation trenches as per drawing and technical specification cl. 305.3.9
I. Sand filling
39.42
-
1644.26
Brick Masonry Work in cement mortar in foundation of Head walls complete exculding pointing and plastering as per drawing and technical specification Clause 1109
(ii) Brick Masonry in 1:4 cement mortar
71.92
-
7450.77
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
144.33
-
146.41
Cross Drainage works : Slab Culvert 1.00m x 1.00m Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material..
I. In ordinary soil. Upto 3 m depth
40.23
-
127.69
Bedding of pipe
(ii)Type B (First Class) Bedding Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105 (ii) Granular Material
3.96
-
1558.04
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 802, 803, 1202 & 1203.
A. With crushed stone.
PCC Grade M10, Nominal Mix 1: 3: 6
1.57
-
6036.57
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A) With Crushed Stone
(iii) P.C.C Grade M20
Nominal mix (1:2:4)
16.57
-
6664.29
Brick Masonry Work in cement mortar in foundation of Head walls complete exculding pointing and plastering as per drawing and technical specification Clause 1109
(ii) Brick Masonry in 1:4 cement mortar
33.95
-
7450.77
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
B) With crushed stone, II. R.C.C Gr.M-25 a) for height upto 5.0M, For Deck Slab..
11.34
-
8677.89
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 (A) With crushed stone
3.56
-
14419.59
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
36
-
134.7
Supplying, fitting and placing MS Bar (Fe-500) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202 (i) For Deck Slab.
1.66
-
65253.54
Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage.
(b) Excluding Edge block/ Edge restraints
79.2
-
941.4
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401
(II) For Grading II Material.
15.84
-
2304.82
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
86.09
-
146.41
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements