Public Works Roads Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Public Works Roads Department - PWRD Tender

Civil And Construction
Bridge Construction
Eprocure
Opening Date5 Dec 2022
Closing Date22 Dec 2022
Tender Amount₹ 6,31,01,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land

2895.77

-

339.68

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material

2060

-

2840.82

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means

1029.7

-

4583.37

... More
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per echnical specification clause 1504 including carriage. a) including Edge block/Edge restraints

13731.18

-

1161.08

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 600mm equilateral triangle

11

-

3933.19

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 802 600mm circular

2

-

5345.8

... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 803 800mm x 600mm rectangular

3

-

7537.1

... More
Providing Hump type speed breaker PCC M20 ( Nominal mix (1:2:4))

11.25

-

6664.29

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

-

24845.31

... More
Kilometre Stone: Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 II)Ordinary Kilometer Stone (Precast)

4

-

2509.18

... More
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75mfrom the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed. (a) 15 cm dia. RCC guard post with reinforcement of 6nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c

200

-

1324.36

... More
2NOS.RCC BOX CULVERT 4.00MX4.00M & 1NO. 3.0MX3.0M RCC BOX CULVERT :Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil Upto 3 m depth

1025.53

-

127.69

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 .A. With crushed Stone I. P.C.C grade M 10 ,Nominal mix 1:3:6

79.97

-

6036.57

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 .A. With crushed Stone II) P.C.C grade M 15 Nominal mix (1:2.5:5)

173.05

-

5894.19

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 .A. With crushed Stone IV ) R.C.C Grade M20

86.33

-

7072.9

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 A. With Crushed StoneI) P.C.C grade M 15 (1:2.5: 5)

69.76

-

6234.21

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 A. With Crushed Stone I) RCC Grade M20, Height upto 5.0m

95.74

-

7480.82

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 A , With crushed stone ii) R.C.C grade M 25 (a) Height upto 5M

61.79

-

8160.44

... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3

45.8

-

2763.19

... More
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar . (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

20.72

-

65217.95

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

112

-

134.71

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 ii) Sandy material

58.2

-

1822.69

... More
RCC BRIDGE 2X24.75M SPAN :Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. (i)Ordinary soil A.Manual Means (I) Without dewatering upto 3 m depth

232.67

-

137.86

... More
Pile load test on single vertical pile in accordance with IS:2911(Part-IV). a). Initial and Routine load test.

345

-

372.9

... More
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm)

550.63

-

11495.49

... More
Levelling course for pile cap

18.84

-

5821.76

... More
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification. Including steel shuttering formwork (N) without plasticiser B. RCC grade M25 (i) Using Concrete Mixer

170.28

-

7469.3

... More
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)

50.64

-

64120.72

... More
Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications and steel shuttering formwork. (N) without plasticiser F. RCC Grade M 25 Case – I : Using Concrete Mixer 1.Height up to 5.0 m

144.44

-

7939.38

... More
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications (a)TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)

22.82

-

64274.4

... More
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical specifications.

213840

-

1.37

... More
Furnishing and placing reinforced / Prestressed cement concrete in superstructure as per drawing and Technical Specifications. Including steel shuttering formwork. (N) Without plasticiser B. RCC Grade M 25 Case - I : Using Concrete Mixer ii) For T-beam and alab (a) Height upto 5m

229

-

8977.85

... More
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent

35.18

-

70631.78

... More
Providing and laying cement concrete wearing coat M 30 grade including reinforcement complete as per drawing and Technical Specifications

28.51

-

13358.86

... More
Construction of pre cast RCC railing of M30 Grade in situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500 center to center spacing between vertical post not to exceed 2000 mm leaving adequat space between vertical post for expansion, complete as per approved drawings and technical specifications.

110.52

-

1985.41

... More
Providing and and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70mm, complete as per approved drawings and standard specificatons to be installed by the manufacturer / supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.

22.5

-

28759.63

... More
Drainage spouts complete as per approved drawings and technical specifications.

22

-

9075.03

... More
Carrying out Sub Soil Investigation ( SSI), for all types of soil (except boring in rock) upto a depth of 30m or refusal ( N=100) for each foundation location as per IRC : 78-2000 and submission of SSI report to the Engineer in -Charge for approval. Preparation & submission of Design calculation & Drawings of foundations, Sub Structures, Super Structures as per relevant IRC codes and SSI report , 2 ( two) copies each of Design & Drawings of each Bridge to be submitted for approval and 8 (eight) copies after approval of competent authority.

2

-

127927.02

... More
Providing and constructing temporary island for construction of pile foundation with depth of water upto 4.0m complete as per technical specification.

1

-

63713.58

... More
Providing and laying pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and technical specifications I. Stone/Boulder

228.38

-

1860.88

... More
Providing and laying filter material underneath pitching in slopes as per drawing and technical specifications.

114.19

-

2049.37

... More
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301

315.45

-

2780.59

... More
Utility Shifting

1

-

121053.3

... More
Metal Beam Crash Barrier, Type - A: "W" Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2m center to center, 1.8 m high, 1.1m below ground/road level, all steel parts and fitments to be galvanized by hot dip process, all fitting to conform to IS:1367 and IS:1364, metal beam rail to

160

-

4852.11



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.