Public Works Building And NH Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,94,092Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWBNH_37227_1Bid Award Id
ViewTender No
No. 688 Dated 09-03-2024Tender Authority
Public Works Building And NH Department ViewPurchaser Address
-Website
http://https://pwdbnh.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Centering and shuttering including strutting, propping etc. and removal of form for
Lintels, beams, plinth beams, girders, bressumers and cantilevers
171.39
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts
58.8
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
308.65
-
-
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
Second class teak wood
4.11
-
-
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)
Second class teak wood
35 mm thick shutters
95.27
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 1000x1000 mm
218.46
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
31.44
-
-
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm .....
(a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
218.46
-
-
20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
712.56
-
-
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.
122.65
-
-
Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete.
712.56
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Water thinnable cement primer
712.56
-
-
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
712.56
-
-
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting
to size and shape wherever required.
1.00 mm thick with zinc coating not less than 275 gm/m²
282.42
-
-
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
3923.19
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
103.97
-
-
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
78.04
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more
8999.68
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
34.33
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
6.48
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
30.36
-
-
Providing soiling in foundation and under floor at all levels with stone / best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the sub grade as directed including all labour and materials and if necessary dewatering , complete
79.27
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.18
-
-
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
51.84
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
155.45
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts
43.2
-
-
Suspended floors, roofs, landings, balconies and access platform
144.14
-
-
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:4 (1 cement : 4 coarse sand)
12.62
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
225.9
-
-
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
8.21
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
107.6
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
42.69
-
-
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
13.68
-
-
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
130.07
-
-
20 mm plaster of mix
1:4 (1 cement: 4 fine sand)
624.32
-
-
Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete.
754.39
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Water thinnable cement primer
754.39
-
-
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.
New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
754.39
-
-
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm .....
(a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
107.6
-
-
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
Second class teak wood
1.44
-
-
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)
Second class teak wood
35 mm thick shutters
37.33
-
-
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
5
-
-
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern
2
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
"White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps
with elbow including operated levers
7
-
-
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe
40 mm dia
7
-
-
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
6
-
-
Providing and fixing toilet paper holder :
Vitreous china
7
-
-
Providing and fixing soil, waste and vent pipes : 100 mm dia
Sand cast iron S&S pipe as per IS: 1729
60
-
-
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
100 mm inlet and 100 mm outlet
Sand cast iron S&S as per IS: 3989
4
-
-
Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) :
100 mm dia
25
-
-
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
2
-
-
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
3
-
-
Providing and fixing brass bib cock of approved quality :
20 mm nominal bor
2
-
-
Providing and fixing brass stop cock of approved quality :
20 mm nominal bor
2
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 15 mm dia nominal outer dia pipes
65
-
-
20 mm dia nominal outer dia pipes
55
-
-
25 mm dia nominal outer dia pipes
50
-
-
32 mm dia nominal outer dia pipes
35
-
-
40 mm dia nominal outer dia pipes
30
-
-
50 mm dia nominal outer dia pipes
25
-
-
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc
Internal work - Exposed on wall
15 mm dia nominal bore
50
-
-
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.
Internal work - Exposed on wall 20 mm dia nominal bore
55
-
-
32 mm dia nominal bore metre
45
-
-
40 mm dia nominal bore
40
-
-
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
20 to 40 mm nominal bore
6
-
-
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)
20 mm nominal bore
6
-
-
32 mm nominal bore
4
-
-
40 mm nominal bore
4
-
-
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
15 mm nominal bore
6
-
-
20 mm nominal bore
6
-
-
25 mm nominal bore
6
-
-
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
40 mm nominal bore
Horizontal
4
-
-
Vertical
4
-
-
Providing and fixing uplasticised PVC connection pipe with brass unions :
30 cm length
15 mm nominal bore
15
-
-
20 mm nominal bore
15
-
-
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
6000
-
-
Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :
Up to 6 metres depth
6
-
-
Beyond 6 m and up to 12 m depth
6
-
-
Beyond 12 m and up to required depth
20
-
-
Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality.
2.5
-
-
Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories.
1
-
-
"Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :
"
50 mm nominal bore
1
-
-
"Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
"
150 x 100 mm size P type
" With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5"
7
-
-
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5
5
-
-
Reducing Socket, bend, tee, etc.
1
-
-
Supplying of Furnitures
Chair
21
-
-
Steel Almirah
17
-
-
Bed (Single)
16
-
-
Study Table.
19
-
-
Wiring for the light point/fan point/exhaust fan point/call point with 1.5sqmm. FRLS PVS insulated copper conductor single core cable in surface/recessed medium class PVC conduit,with pioano type switch,phenolic laminated sheet,suitable size M.S box and earthing the point with 1.5 sq.mm Copper conductor single core cable etc.as required.
Group C
61
-
-
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etx. As required.
5/6 A switch
10
-
-
2 way 5/6 A switch
5
-
-
3 pin 5/6 socket outlet
10
-
-
6 pin 15/16 A socket outlet
5
-
-
wiring for curcuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduct as required.
2 x 2.5. sq.mm+1x2.5sq mm earth wire
143
-
-
2 x 4 sq. mm + 1 x4 sq. mm earth wire
123
-
-
2 x 6 sq. mm + 1 x 6sq. mm earth wire
119
-
-
Installation, testing and commissioning of star rated ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
12
-
-
Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
24
-
-
Supplying and fixing following ModularGI Box base & cover plate on existing modular metal boxes etc. as required.
8 module (125mmx125mmm)
4
-
-
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
8 module
4
-
-
Supplying and fixing of following ways single pole and neutral sheet steel MCB distribution board 240 V on surface complete with thinned coper - bus- bar neutral bus bar - - - - -isolator.
12 way
1
-
-
Supplying and fixing of following ways single pole and neutral sheet steel MCB distribution board 240 V on surface complete with thinned coper - bus- bar neutral bus bar - - - - -isolator.
16 way
1
-
-
Supplying and fixing following rating, double pole, (single phase and neutral ), 240 V, residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40A
10
-
-
Earthing with G.I. earth pipe 4:5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. charcoal/coke and salt as required.
6
-
-
Supplying and laying 6SWG G.I. wire 0.50 metre below ground level for conductor earth electrod including masonary - - - - GI thimble etc as required.
40.6
-
-
Supplying testing of 4 ft LED Tube light batten including all accessories as directed by the deptt.
43
-
-
Supplying of following size of PVC/XLPE insulated and PVC sheathed1.1KV grade Solid aluminum conductor up to 10.sq.mm balance strnded conductor ,XLPE insulated ,cores laid up ,PVC tap innersheathed ,Armour (Aluminium wire for single core up to 70 sq.mm balance luminium strip ,Galvanised wire for cables up to 2x10 sq.mm ,3x10 sq.mm 4x6 sq.mm and balance all galvanised steel strip) extruded PVC type ST2 sheathed 650/1100V grade as per IS 7908 (part-1) 1988 armoured U.G Cable as specified and direced by the department(Plaza or equivalent make as approved by this department) 70 sq.mm UG cable
166
-
-
Supplying with including fitting fixing Of Exhaust Fan etc. AS directed by the Deptt.
7
-
-
Supplying instalation of Testing of and commissioning of Hi-Wall Inderter 5 Star 1.5 Ton rating non ducted aplit type Air-condition with remote complete with coper pipe and complete electrical connection as approved by the depttt.
3
-
-
Supplying Instalation, Testing and commissioning of Voltage stabiliser 4KA for Air Conditioner as directed by the deptt.(V guard or equvalent make)
3
-
-
Supplying with fitting and fixing Single Phase Modular Motor starter switch of the following specification complete including making necessary connection as specified and directed by the deptt.
3
-
-
Supplying Instalation , Testing and commissioning of Storage water heater /Geuser vertical type 25 ltr capacity (venus or equvalent)
1
-
-
Supplying Instalation , Testing and commissioning of Miniature Circuit Breaker Distribution board including all accessories as directed by the deptt. (venus or equvalent)
2
-
-
Providing and fixing of lightning conductor final, made of 25 mm dia. 300mm long GI tube having single prong at top with 85mm dia 6mm thick GI base plate including holes etc. complete as directed.
4
-
-
Providing and fixing testing joint made of 20mmx3mm thick GI strip 125 mm long with 4 nos of G.I. bolts nuts and spring washer etc. complete as required.
140
-
-
Supplying testing and commissioning of IP66 LED Street Light 60W including all accessories as directed by the deptt. (Wipro or equivelent make)
10
-
-
Supplying testing and commissioning of 1 KVA Online UPS with Battery of Back up time of 60 minutes as specified and directed by the deptt.
1
-
-
Supplying testing and commissioning of Kirlosker Submerssible pumpset, single phase with motor rating of 0.75 Kilowat as specified and directed by the deptt.
2
-
-