Public Works Building And NH Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 2,00,720Document Cost
₹ 3,011Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_PWBNH_24837_1Bid Award Id
ViewTender No
CE/TB-III/37/2022/2 Dated Guwahati 21st Mar 2022Tender Authority
Public Works Building And NH Department ViewPurchaser Address
-Website
http://https://pwdbnh.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
670.81
-
-
Mild steel and Medium Tensile steel bars
305
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
3.19
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu-
ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
6.26
-
-
Centering and shuttering including strutting, propping etc. and removal of form work for :4.3.1 Foundations, footings, bases for columns
23.61
-
-
Columns, piers, abutments, pillars, posts and struts
31.24
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level in
all shapes and sizes in :
Cement mortar 1:
2.4
-
-
Supplying and filling in plinth with sand under floors, including watering,
ramming, consolidating and dressing complete.
42.74
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished seamless type tubes.
483.32
-
-
Providing corrugated G.S. sheet roofing including vertical / curved
surface fixed with polymer coated J or L hooks, bolts and nuts 8
mm diameter with bitumen and G.I. limpet washers or with G.I. limpet
washers filled with white lead, including a coat of approved steel
primer and two coats of approved paint on overlapping of sheets
complete (up to any pitch in horizontal/ vertical or curved surfaces),
excluding the cost of purlins, rafters and trusses and including cutting
to size and shape wherever required.12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
27.3
-
-
15 mm cement plaster on rough side of single or half brick wall of
mix:13.5.1 1:4 (1 cement: 4 coarse sand)
34.44
-
-
Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered wall
surface to prepare the surface even and smooth complete.
34.4
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm
over and including priming coat of exterior primer applied
@ 2.20 kg/10 sqm)
34.4
-
-
Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built - In pressure Gauge to know the Readyness of the Extinguisher Squeeze Grip Handle As per IS: 15683 with ISi Each Mark (06 kg capacity) Brand – Fire stop
2
-
-
Supply, Installation, Fixing of Carbon dioxide fire Extinguisher confirming to IS : 15683 with ISi Mark (4.5) Kg. Brand - Firestop
2
-
-
Supply, Installation, Fixing of Foam S/P type 91tr capacity Fire Extinguisher complete in all respect with ISI Mark. IS - 15683. Brand – Fire stop
2
-
-
SITC of Terminal Uni Gas Outlets [ for Oxygen/Vacuum/ Nitrous Oxide & Medical Air ] with probes/ Adaptors.
60
-
-
SITC of Oxygen BPC Flow meter with Humidifier Bottle
20
-
-
SITC of Low Pressure Tubing Flexible antistatic tube
100
-
-
SITC of Ward Vacuum Unit with Regulator alongwith vacuum gauge, collection jar of 600ml capacity.
20
-
-
SITC of Medical Grade Copper Pipe 12mm OD x 0.7mm Thick conforming to BS EN 13348, Llyods certified
90
-
-
SITC of Medical Grade Copper Pipe 15 mm OD x 0.9mm Thick conforming to BS EN 13348, Llyods certifie
200
-
-
SITC of Medical Grade Copper Pipe 22 mm OD x 0.9 mm Thick conforming to BS EN 13348, Llyods certified
250
-
-
SITC of Medical Grade Copper Pipe 28 mm OD x 0.9mm Thick conforming to BS EN 13348, Llyods certified
200
-
-
SITC of Medical Grade Copper Pipe 42 mm OD x 1.2 mm Thick conforming to BS EN 13348, Llyods certified
70
-
-
SITC of Zonal Valve Box with configurations are Valve Boxes are described.:- i) 3 Gas Services- O2, Vacuum, Air
1
-
-
SITC of Area Line Pressure Alarm as per standard specifications all as specified and as directed for 3 Gas Service.
2
-
-
SITC of Isolation Valves suitable for 12mm OD copper pipe
6
-
-
SITC of Isolation Valves suitable for 15mm OD copper pipe
10
-
-
SITC of Isolation Valves suitable for 22 mm OD copper pipe
5
-
-
SITC of Isolation Valves suitable for 28mm OD copper pipe
2
-
-
SITC of bed head pannel with vac slider,monitor tray
15
-
-
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following sire direct in ground including excavation, sand cushioning, protective covering and refilling the trench eta as required.
Above 185 sq. mm and upto 400 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required.
60
-
-
Above 185 and upto 400 sq mm (clamped with 40x3mm MS flat clamp)
Supplying and facing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
175
-
-
25mm
110
-
-
Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
400 A 50 KA FPMCCB
2
-
-
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/coke and salt) as required.
4
-
-
Supplying and laying 25 mm x 5 mm copper strip at 0.50 (metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
32
-
-
Providing and faxing 6 SWG diaG.l wire on surface or in recess for loop earthing as required.
110
-
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc as required
30
-
-
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm x 7.5 mm thick, thimble, stay clamps, turn buckle (20 mm X 600 (mm) 7/ 400 mm dia G.1 stay wire and 11 KV strain insulator etc in cement concrete 138 (1 cement: 3 coarse sand 6 graded stone aggregate 40 min nominal size) foundation including excavation and refilling etc. as require.
1
-
-
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both s w with inscription in single red colour on front side as required
4
-
-
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:
185sq.mm/240 sq.mm
4
-
-
Erection of steel tubular or rail pole strut in comment concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including Each excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
4
-
-
Supplying, installation, testing and commissioning of the 250KVA 11/0.433KV copper wound out door type oil filled 4 STAR Level-2 transformer complete including all accessories like Earthing terminal, Liftung Lugs, Drain Valve, Oil filling Hole with plug, Silicagel Breather, First filling of Ollas per IS355, Arcing Hom, Radiator, Air Release Plug, Conserver Tank eta along with cost of load security, Meter Security and making necessary arrangement of obtaining NOC for charging approval of the station from the competent authority as directed and specified by the department Transformer should be as per CEA guidelines as amended up to date (All required materials for the Sub-Station will be measured & paid
1
-
-
Supplying including installation, testing and commissioning of Water Cooled Diesel Generator set coupled complies with current CPCB-II emission norms to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. mounted on a 1) MS. Fabricated base frame 2) MS. fuel tank of required capacity, 3) Residual silencer (Stack hight shall be menimum 6.0mtr above the building where the gen set is installed), 4) AMF Control Panel 5) Suitable batteries with lead, 5) First fill of lube oil, 6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to 15 comprising the Technical Specification as per manufacturer. (RANGE FROM S KVA TO 625 KVA Kirloskar KOEL, Greaves, JAKSON or equivalent alternator. Water Cooled Diesel Generator set
1
-
-
Supply with installation & commissioning of readymade maintenance free CPRI approved chemical earthing system with 100 MM dia. 2.9 Metres length corrossion free centrifugally Cast Iron Earthing Electrode complete with Reslow/BFC Grounding chemical compound (40 KG) and Advance Earth Pit cover (CI) of size 300 mmx300 mm including excavation of earth pit and construction brick earth chamber including plastering both Inner & outer surface of brick wall as specified and directed by the deptt.
4
-
-
Supplying and fitting fixing of galvanised Angle of 50mm x 50mm x 6mm size complete with clamp, bolts nuts etc. as required and as directed by the Department.
15
-
-
Supplying and fitting fixing of galvanised channel cross arm of 100mm x 50mm x 6 x 2200 mm long complete with clamp, bolts nuts etc. as required and as directed by the Department.
23
-
-
Supply Including fitting and fixing of 11 KV ISOLATOR with Earth Switch and G.L. mounting structure as specified and directed by the Deptt.
1
-
-
Supply including fitting and fixing of 11 KV GOAB switch 150A as specified and directed by the Deptt.
1
-
-
Supply including fitting and fixing of 11 KV DO Fuse 150A as specified and directed by the Deptt.
1
-
-
Supply including fitting and fixing of 12KV 9KA lightning Arrester Line Type as specified and directed by the Deptt.
1
-
-
Supply including fitting and fixing of 11 KV Disc insulator (Polymeric) 70 KN with H/W as specified and directed by the Deptt.
12
-
-
Supply including fitting and fixing of 11KV Pin Insulator as specified and directed by the Deptt.
12
-
-
Supply including fitting and fixing of C.I earth pipe 18m inner dia 100mm outer dia 110mm as specified and directed by the Deptt.
8
-
-
Supply of G.L. Steel Tubular Pole SP-66 as specified and directed by the Deptt.
4
-
-
Supplying Including fitting and fixing of the following Sub- Station accessories including all necessary required materials as specified and directed by the Deptt. 1) G.L. nuts & bolts with G.L. washer (Assorted)-50Kg.
2) G.I. Pole Clamp-9 Nos.
3) P.G. Clamp- 6 Nos
4) Cable Gland -4 Nos
5) Bimattalic Lug. -24 Nos.
1
-
-
Supply including fitting and fixing of H.T. Trivector Meter as specified and directed by the Deptt
1
-
-
Supply including fitting and fixing of Metering Cabinet as specified and directed by the Deptt.
1
-
-
Supply including drawing of ACSR RacconConductor as specified and directed by the Deptt.
250
-
-
Supply including fitting and fixing of Distribution Transformer (DTR) Fenching as specified and directed by the Deptt
1
-
-
Supplying of following sizes XLPE insulated and PVC sheathed copper conductor armoured power cable of LT 1.1 KV grade conforming to IS 7098 (Part-1)/1988 with amendment up to date etc as required. Control cable 10 Core X 2.5 sq.mm
30
-
-
Supplying of following sizes XLPE insulated and PVC sheathed aluminium conductor armoured power cable of (HT 11 KV (UE) grade conforming to 5 7098 (Part-2)/ 2011 with amendment up to date etc as required. 1 Core 185 Sq. mm HT Cable (1K185) sq.mm
75
-
-
Supplying of following sizes XLPE Insulated and PVC sheathed aluminium conductor armoured power cable of LT 11 V grade conforming to 15 7098 (Part-1)/1988 with amendment up to date etc as required. 1 Core 400 Sq. mm LT Cable (1x400) sq.mm
60
-
-
Supplying of following stres XLPE insulated and PVC sheathed aluminium conductor armoured power cable of LT 1.1 KV grade conforming to IS 7098 (Part-1)/1988 with amendment up to date etc as required.
3 & 1/2 Care 300 Sq. mm armoured LT Cable (3 &1/2 X 100) sq.mm
76
-
-
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatsed Powder Painted cubical outdoor type double door, floor mounting compartmentalize panel board of size 0.8M X0 8MX 0.40M made of 16 SWG (1.66 mm thick) C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom and CR sheet roofing on the lop. The panel board is to be erected in 1:3:6 PCC foundation including excavation of bench and brick soling et complete neatly wiring done with provision for ons no 315/400 A 4pole MCCB or with Fuse Unit as incomer and out going as specified and directed by the deptt. confirming to IP 65 protection comprising of the following electrical an
1.40mm X5mm (4x2) srp copper Bus-Bar 0.20 length each 2. Digital 3 Phase Voltmeter Accuracy class 0.5-1 no
3. Digital 3 Phase Ammeter Accuracy class 0.5-1 no 4. Plot Lamp with integral ckt LED 110-230 V (Red, Yellow & Blue) -3 nos
5. Voltmeter & Ammeter Selector Switch-2 nos
6.2 A Side fuse unt-3 nos
(Incoming & Outgoing Switch Gear of regd. rating will be measured and paid separately)
1
-
-
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor type double door, floor mounting compartmentalize panel board of size 0.95M X 1.30MX 0.40M made of 16 SWG (1.68 mm thick) C.R. sheet and 40mm X 40mm X 5mm size angle having 4 no legs at the bottom and C.R. sheet roofing on the top. The panel board is to be erected in 1 3:6 PCC foundation including excavation of tranch and brick soling etc. complete neatly wiring done with provision for one no 400 A 4pole MCCB or Switch Fuse Unit an incomer and provision for 4nos DP or TPN out going as specified and directed by the deptt. confirming to IP 65 protection comprising of the following electrical item.
1.i) 40mm X 5mm 4 strip copper Bus-Bar 1.20 M length each
ii)25mm X 5mm 4 strip copper Bus-Bar 0.5M each 4 sets
2. Digital 3 Phase Voltmeter Accuracy class 0.5-1 no 3. Digital 3 Phase Ammeter Accuracy class 0.5-1 no
4. Plot Lamp with integral ckt LED 110-230 V (Red, Yellow & Blue) -3 nos
5. Voltmeter & Ammeter Selector Switch -2 nos
6.2 A Side fuse unit-3 nos
(Incoming & Outgoing Switch Gear of regd. rating will be measured and paid separately)
1
-
-
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 315A 4P MCCB (ics = Icu, adjustable ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415V 50 Hz 315A 4P MCCB
(C&S, Havells, Indo Aslan, HPL V-Guard or equivalent make as approved by the Deptt.)
1
-
-
(C&S, Havells, Indo Aslan, HPL V-Guard or equivalent make as approved by the Deptt.)
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 125A 4P MCCB (Ics=cu, adjustable ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
25KA 415V 50 Hz 125 A 4P MCCB (C&S, Havells, Indo 25 Asian, HPL, V-Guard or equivalent make as approved by the Deptt.)
1
-
-
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 63A 4P MCCB (Ics-icu, adjustable ir setting 0.7) without enclosure of the following capacity complete with making necessary connection approved, specified and directed by the deptt.
25 KA 415V 50 Hz 63A 4P MCCB (Havells, HPL, Indo Asian make)
2
-
-
Cost to be paid to the APDCL for their deposit work including supervision charge etc. as per their submitted bill.
1
-
-
Supplying of following sizes XLPE insulated and PVC sheathed copper conductor armoured power cable of LT 11 KV grade conforming to IS 7038 (Part-1)/1988 with Control mendment up to date etc. as required.
cable 3 Core X 2.5 sq.mm armoured-2XWY/2XFY.
210
-
-
CCTV Installation, testing and demonstration charges
1
-
-
Cattle Bridge & Gate
Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets,
gates and similar works
1341.91
-
-