Public Works Building And NH Department Tender

... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Public Works Building And NH Department - PWDBNH Tender

Civil Works Others
Eprocure
Opening Date2 Sep 2021
Closing Date15 Sep 2021
Tender Amount₹ 7,43,80,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (b) In prop 1cement: 4 sand :8 coarse aggregate by volume

293.85

-

-

... More
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. b) 50mm thick

49.69

-

-

... More
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.

50

-

-

... More
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser c) M25 grade concrete

866.43

-

-

... More
(B) In super structure from plinth level up to 1st floor level ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser c) M25 grade concrete

131.26

-

-

... More
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank

169.82

-

-

... More
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face

153.91

-

-

... More
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.

385.46

-

-

... More
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.

219.69

-

-

... More
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.

710.06

-

-

... More
Providing form work of 12mm thick Plywood board and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first floor level. (a) Thickness not exceeding 200mm.

123.89

-

-

... More
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.

64.3

-

-

... More
(II) In superstructure above plinth level up to 1st floor level. (d) In proportion 1:6.(1 cement:6 sand)

89.89

-

-

... More
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)

522.49

-

-

... More
112 mm thick reinforced brick wall in prop 1:5 reinforced with two lines of M.S rod/ Tor steel as specified embeded in 38 mm thick concrete course in prop.1:2:4 with coarse agg. 12mm down at every fourth courses embeded with protruding rod in column including curing etc.complete as directed ( M.S rod/Tor steel shall be measured and paid separately) in super structure above plinth up to 1st floor level.

522.49

-

-

... More
Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/ R.B wall

112.15

-

-

... More
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (A) CERAMIC i)Normal range (Sizes 300 mm x 300mm and above) (a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate

162.14

-

-

... More
B) ON WALLS Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). i) Of size 200mmx300mm and above

564.06

-

-

... More
VITRIFIED TILES A) ON FLOOR Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above

281.54

-

-

... More
B) ON WALLS Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). i) Of size 300mmx450mm and above

29.93

-

-

... More
Kota-stone slab flooring of 18 mm thick over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (1) 550mm x 550mm

141.78

-

-

... More
Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete. (1) 550mm x 550mm

6.14

-

-

... More
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. d) In cement mortar 1:6

219.69

-

-

... More
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side d) In cement mortar 1:6

1004.65

-

-

... More
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side d) In cement mortar 1:6

443.34

-

-

... More
Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed. i) 10 mm thick plaster d) In cement mortar 1:6

219.69

-

-

... More
Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed. ii) 15 mm thick plaster d) In cement mortar 1:6

1447.99

-

-

... More
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.

219.69

-

-

... More
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. a) On Single coat plaster

123.36

-

-

... More
Ceiling with Exposed Metal (G.I.) Frame work with E-Grid - 2430 Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. Finally, if specified, boards are to be painted with 2 coats of acrylic emulsion paint of approved shade/make over a coat of cement primer before installing it on the grid. (A) Standard Ceilings of Everest make or equivalent as directed by the departement (ii) Using 6 mm thick FC Board

122.51

-

-

... More
GYPBOARD CEILING Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). (ii)12.5mm thick

30.63

-

-

... More
ROOF TREATMENT Grading roof for water proofing treatment with (b) Cement mortar (i) 1:3 (1 cement: 3 coarse sand)

32.89

-

-

... More
Providing and laying six course water proof treatment with bitumen felt over roof consisting of first, third and fifth courses of blown or residual bitumen applied hot @ 1.45kg, 1.20kg and 1.45kg per sq.m of areas respectively, second and fourth courses of roofing with felt type 3 grade - I (hessain base self finished bitumen felt) and sixth and final course with stone grit 6mm and down per sq.m including preparation of surface, excluding grading complete.

506.06

-

-

... More
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/ Sundi)

0.97

-

-

... More
BLOCK BOARD SHUTTERS Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. b) Non decorative type and block board core. (ii) 35 mm thick .

54.75

-

-

... More
BLOCK BOARD SHUTTERS Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. b) Non decorative type and block board core. (iv) 25 mm thick .

10

-

-

... More
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. II Ornamental grill (ms-Staircase quantity also added) (c) Fixed to Brickwork/P.C.C/R.C.C.

5216.4

-

-

... More
Supplying, fitting and fixing anodised aluminium decorated grill with anodised aluminium rectangular frame of 'F' and 'H' section fitted with walls, columns or stiffeners by special type of screws as per specification by the Department for all levels. (Aluminium Alloy procured from primary aluminium producer (On submission of certificate of alloy purchaging from primary producer)

19.15

-

-

... More
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). a)Side hung and Top hung windows and ventilators i) 6 mm clear glass

21.85

-

-

... More
(b)Fixed windows and ventilators i) 6mm clear glass

60.17

-

-

... More
Providing and fixing anodised aluminium framed double leaf doors of approved brand with styles size 45mm x 48mm x 3.2mm, top rails 50mm x 45mm x 2.5mm, lock rails 48 mm x 45mm x 2.5mm, bottom rails 100mm x 45mm x 2.5mm fitted with tapper clips of size 20mm x15mm x1.2mm complete with automatic floor mounted door closure, butterfly type handles, special cylindrical lock, concealed type aluminium tower bolt,neoprene dryset rubber gusket, door felt gusket, etc.complete as directed by the Department at all levels. (a) Double leaf doors (ii)6mm clear glass

9.75

-

-

... More
FRP FLUSH DOOR Supplying & fixing of factory made 30mm thick Fibreglass Reinforced Plastic (FRP) panneled door shutter of required colour of FIBREWAYS made with fire retardant grade unsatured polyster resin,moulded to 3mm thick FRP laminate for forming hollow rails and styles,with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings,cast monolithically with 5mm thick FRP laminate for panels and conforming to IS:14856-2000 including fixing to frames complete as per direction of Engineer-in charge.

61.11

-

-

... More
FRP FRAME providing & fixing of factory made Fibreglass Reinforced Plastic (FRP) door frame of FIBREWAYS having three legged of cross section 90mmx45mm having single rebet of 32 mmx15mm to receive shutter of 30 mm thickness .The laminate door frame moulded with fire retardant grade unsaturated polyster resin and chopped mat .Door frame laminate and shall be filled with suitable wooden block in all the three legs the frame shall be covered with covered glass from all sides. MS stay shall be provided at the bottom to steady the frame.

192.9

-

-

... More
DISTEMPERING f) Distempering with dry distemper of approved brand and manufacture(two coats)and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.

1224.34

-

-

... More
DISTEMPERING j) Extra over item no. (f) above for distempering with dry distemper on ceiling and or sloping roof.

219.69

-

-

... More
PLASTER OF PARIS & WALL PUTTY Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)

1912.55

-

-

... More
EXTERIOR PAINTS / COATINGS Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak" brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.

443.34

-

-

... More
Extra over item no.13.5.2 above for every subsequent coat of acrylic emulsion exterior coatings of Unicem 'Rakshak' brand of required shade.

57.93

-

-

... More
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (b) With ready mixed paint , wood primer (white).

54.75

-

-

... More
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. (c) With ready mixed paint , Alluminium primer

31.6

-

-

... More
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over 100mm in width or girth. a) General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).

54.75

-

-

... More
b) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).

54.75

-

-

... More
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a) With ready mixed "red-lead/ red oxide" primer.

150

-

-

... More
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) a) Sliding door bolts ii) 250mm x 16mm

54

-

-

... More
b) Tower bolts ii) 250mm x 12mm

59

-

-

... More
v) 100mm x 10mm

93

-

-

... More
c) Door handles ii) 100mm

6

-

-

... More
iii) 150mm

63

-

-

... More
d) Gate shutter hook & eye I) 100mm

2

-

-

... More
l) Hydraulic door closure

6

-

-

... More
m) Mortice lock vertical type iv) Aldrop with In built Lock-6 lever kadi tala(Godrej Make)

9

-

-

... More
n) Drawer locks i) 40mm

54

-

-

... More
o) Cupboard locks i) 40mm

10

-

-

... More
p) Finger plate

10

-

-

... More
q) Kicking plate

16

-

-

... More
r) Curtain rod ii) 25mm x 2mm

31

-

-

... More
t) Door stopper with rubber stopper

63

-

-

... More
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar

230.42

-

-

... More
Steel work welded in built up sections, framed work including cutting, hoisting and fixing in positions and applying priming coat of red-lead paint including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. b) In trusses and trussed purlins up to 25m span and 15.0m overall height.

296.52

-

-

... More
Providing Bare Galvalume Sheet Roofing at all levels including fitting and fixing self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50 mm thick

593.05

-

-

... More
Providing Bare Galvalume Sheet roofing accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iii) 0.50 mm thick

82.54

-

-

... More
Providing plinth protection with bricks laid on edge and grouted with cement mortar 1:4 and finishing with cement pointing in prop. 1:1 complete.

79.65

-

-

... More
WATER PROOFING OF CHAJJAS, ROOF SLABS, TERRACES, SUNKEN SLABS, SEPTIC TANK,OH TANK, RAFT SLAB IN BASEMENT, WALLS ETC. (A) Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/ mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals) @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals) mixed with cement in the ratio 1:2 as final coat.

78.76

-

-

... More
Supplying, providing, mixing and laying over waterproofing layers/ coatings with concrete screed of average 30mm thick or as per drawings/ requirements in proportion 1:2:4 (1cement : 2fine aggregate : 4coarse aggregate) (by volume) with 10mm and down well graded aggregates and admixed with a normal plasticizer like Master Plast PL-1 of Choksey Chemicals /Dr. Sealkit Normal Plast (Asian Chemicals)/Rheomac 707 of BASF @ 0.3% by weight of cement and thereafter scoring the top surface of the concrete screed @ 200mm c/c as specified and directed by the Department.

78.76

-

-

... More
Providing, supplying, mixing, laying 8mm thick cement Plastering in prop.1:6 over R.C.C. surfaces mixed with integral waterproofing compounds like Master Proof IWP-1 of Choksey Chemicals /Dr. Sealkit No.1 (Asian Chemicals) /Rheomac 707 of BASF@ 0.2% by weight of cement conforming to IS:2465 as specified and directed by the Department complete.

78.76

-

-

... More
Providing, supplying, mixing and champhering the edges along joint of wall/ parapet wall and raft/ roof slab having champhered dimension of 150mm x 150mm with cement sand mortar (prop.1:4) mixed with Master Proof IWP-1 of Choksey Chemicals /Dr. Sealkit No. 1 of (Asian Chemicals)/ RHEOMAC 707 of BASF@ 0.2% by weight of cement over a primer coat on the area to be champhered with a combination of 100% acrylic Polymer Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/ RHEOMAC 115 of BASF of Choksey Chemicals and cement in the ratio 1:2 to be applied by brush as specified & directed by the Department complete.

35

-

-

... More
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.

74.28

-

-

... More
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.

595

-

-

... More
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.

595

-

-

... More
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.

215.2

-

-

... More
Supplying , fitting and fixing barbed wire fencing with seven strands of barbed wire 12 S.W.G.x 2pliesx 4 points at 75mm apart including supplying fitting and fixing sawn sal wood posts of 100mmx100mm size struts 1800mm long at 1500mm apart driven at least 600mm under ground with providing 100mmx75mm size struts 1800mm long in corner, straining and end post as necessary including coaltaring two coats in posts and struts and supplying necessary nails, staples etc.complete as directed and specified (the distribution of the barbed wire should be placed at equal intervals for the intermediate except bottom and top which is to be placed at 100mm and 230mm clearance respectively).

275

-

-

... More
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts).

18

-

-

... More
Day Time Use Building: Providing & Laying of Insuboard over the PCC, 50Mm Thickness.(Make: M/S Supreme or equivalent) (PCC with proper Slope Over RCC)

5

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up , including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm

7

-

-

... More
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer Using rough kota stone.

258.88

-

-

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone

303.04

-

-

... More
Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:

1475

-

-

... More
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing. 30 mm thick

244.44

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainles steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

2766

-

-

... More
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin- charge.

57

-

-

... More
Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge.

52

-

-

... More
Providing WPC deck floor planks of section 150mm X 25mm, made from Hybrid grade polymer, 45% wood fiber and 10% Additives with UV stabilizers etc. WPC should be be weather proof, water proof, termite proof and suitable to be used in outdoor spaces with temperatures ranging between -43deg to +60 deg. WPC flooring section should have bulk density of 1.2 g/cc. WPC flooring have thickness of 25mm and width 150 mm. WPC flooring to be supported on WPC sub structure made up of 25X40mm WPC profile (Distance between two supporting elements is not more than 450mm)

1058.7

-

-

... More
For Isolated Footing, Raft supported on Piles : Using Pre Applied (Smooth Type, Acrylic Finish) Fully bonded HDPE membrane: Supplying and installing a positive side waterproofing treatment for “Raft Slab'' by using "MasterSeal 730 UVS" (smooth type) , 1.2 mm thick, flexible, "Fully-Bonded HDPE Membrane" before casting of the base RCC slab and shall conform to all grades of basement as defined in IS 16471. The pre-applied membrane to adhesively bonded to the underneath of the poured concrete used as base/ raft slab to resist lateral water migration between membrane and base/raft slab. Membrane shall consist of 4 layers: i) A thick white HDPE carrier film ii) A pressure sensitive adhesive, iii) trafficable & weatherable acrylic protective coating which bonds integrally to poured concrete iv) Release liner (Release liner to be removed before laying reinforcement). The pre-applied membrane shall be installed with standard 80mm selvedge laps and 80mm end laps taped with MasterSeal 936 a double side coated adhesive tape over the entire area and turned up on to removable formwork and stopped 50mm below the thickness of concrete slab. The membrane shall be laid over the concrete blinding having smooth dried surface including necessary removal of release liner while applying, necessary overlaps between the membranes and fixing overlaps by Tape, firm rolling onto the surface to get a tight seal, etc.. Mechanically bonded membranes, membranes with fleece on top of base layer and membranes with sanded/particulate layer on top of pressure sensitive adhesive are not permitted The fully bonded HDPE sheet waterproofing membrane shall have following typical properties: 1) Colour: White 2) Resist hydrostatic pressure of - 61 m head of water (as per ASTM D5385) 3) Peel adhesion to concrete - 1.8 N/mm (as per ASTM D903 modified) 4) Puncture Resistance – 1000 N (as per ASTM E 154 modified) 5) Elongation - 500% (as per ASTM D412) 6) Tensile strength, Film - 25 Mpa (as per ASTM D412) 7) Dimesional Stability - 0.5 % (as per ASTM D1204) All systems to be installed as per manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed by Engineer in-charge.

1310.64

-

-

... More
For Unconfined Retaining Wall: Using Self Adhesive, Fully Bonded, HDPE Laminated SBS Sheet Membrane: Supplying and Installing 'MasterSeal 726' , a self-adhesive, cold applied , flexible, 1.5mm thick polymer modified bituminous waterproofing membrane laminated onto a tough HDPE film ( 100 Microns) on one side and silicone release liner on the other. Flame and welded parts are not permitted. The membrane shall be applied on the uniform surface of the Vertical RCC Wall after application of single component solvent based bituminous primer approved and installed as per BASF’s recommendation. Maximum moisture content of RCC Wall should not be more than 5% while using solvent based primer and not more than 8% while using water based primer. The membrane shall conform to all grades of basement as defined in IS 16471 & should have following typical properties: 1. Thickness: 1.5 mm 2. Hydrostatic Head Resistance: 50 m (as per DIN 16726:2011 -01) 3. Puncture Resistance: 12.8 N.mm (as per ASTM G14:2004) 4. Tensile strength : 3.4 MPa (Median) (as per ASTM D 412) 5. Peel Adhesion strength : 2.4 KN/m Width (as per ASTM D 1000) Note: In case of Raft having toe, making angle fillet (50x50) mm at all intersection between horizontal & vertical surfaces using cement sand mortar (1:3) admixed with MasterEmaco SBR 2 @ 5 Kgs/Bag of cement and finished smooth before application of bituminous primer followed by application of MasterSeal 726 membrane (ONLY PRIMER AND MEMBRANE IN APPLICATOR SCOPE), and finally laying M20 grade protective screed in 50 mm thickness over MasterSeal 726 membrane on toe area shall be in civil contractor's scope.

300

-

-

... More
The membrane shall be laid as per below procedure: Surface Preparation: Clean the concrete surface with brush and make it free from dust, laitance, frost, mould release agents, curing compounds and sharp protusions. Remove any sharp protrusions on the concrete surface by chipping and local repairs. All abrupt irregularities, voids & honeycombed area shall be made good with repair material before installation of membrane. Membrane Application: Roll out MasterSeal 726 membrane, cut it to manageable lengths and stick it to the surface by peeling off the release paper on the back of the membrane. Press membrane in place, adhesive side down, smoothing out to exclude air. Adjacent rolls to come on premarked overlaps lines printed on both the edges of the membrane to have minimum 50 mm side overlap. All end laps to be minimum of 100 mm. All laps shall be rolled to achieve a good seal & end laps staggered. Continue rolling out the membrane till the entire area is covered. PS: Cost excludes repairing of cracks & honeycombed concrete and filling the same with CM (1:3) mixed with MasterEmaco SBR 2. Membrane Protection against backfilling: Supply & spot bonding 25mm thick expanded polystyrene board or 7-8 mm thick dimple drain board onto MasterSeal 726 membrane. The expanded polystyrene shall have minimum density of 24 kg/cum (or as decided by engineer–in–charge) and shall be applied prior to backfilling. Note: The backfilling (BY OTHERS) shall be free from abrasive materials (nails, sharpnels, boulders, debris) & shall be done in stages (150-250) mm and within 2-3 days of fixing protection board. Note: In case of Raft with Toe --- MasterSeal 726 membrane needs to be protected horizontally (toe area) with 50 mm thick screed (M-20 Grade) including making angle fillet minimum (50mm x 50mm) of cement sand mortar at all intersections between vertical and horizontal surfaces ----- In Civil contractor’s scope.

1310.64

-

-

... More
Option 2: The membrane can be terminated by providing Aluminium flashing (50 mm wide, 2-3 mm thick) fixed with non corrosive fastener & sealing of termination bar with PU Sealant as MasterSeal NP 472. All systems to be installed as per manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed by Engineer in-charge.

150

-

-

... More
Sealing of Tie Rod Holes: Sealing of all tie rod holes in retaining wall by removing PVC Sleeves and filling the cavity with dual shrinkage compensated cementitious mortart MasterEmaco 348.

10

-

-

... More
Sealing of Pipe/Sleeve Penetrations in Retaining Walls: (150 mm dia) The surface of the cut out hole and the pipe shall be thoroughly prepared to ensure the removal loose particles and dust etc. including abrading the pipe outer surface to ensure proper bond to the filling materials. It should be ensured that the annular space around the pipe should be of minimum 50 mm to allow free flow of and proper filling with non shrink grout. The surface has to be pre-wet with water before the application of filling material. Providing and applying hydro-swellabe waterstop MasterSeal 912 of BASF available in paste form in Catridge shall be squeezed out and applied in 6mm bead around the pipe and fixing slurry tight shuttering and laying high strength non shrink cementitious grout MasterFlow 718 or dual shrinkage compensated cementitious mortart MasterEmaco 348 of BASF in to the annular space to fill the entire gap and allowed to harden and cure and sealing around the periphery joints of the pipes using MasterSeal HLM 5000 - a single component, bitumen modified polyurethane waterproofing membrane etc., all complete as per the manufacturer's instruction and the engineer incharge. As per drawing Note: Rate should include cost of materials and labour for application, including conveyance, lead and lift etc., Note: Rates only wherever applicable. All systems to be installed as per manufacturer's recommendations, etc. complete with all lead and lift for all materials and labour and as directed by Engineer in-charge.

10

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kind of Soil

450

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

411

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

39

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:1½:3 (1 cement:1½ coarse sand:3 graded stone aggregate 20 mm nominal size)

2

-

-

... More
Centering & shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns etc. for mass concrete.

373

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

193

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

553

-

-

... More
AddSBM Cess@ 0.5% on DSR and Road SOR item

32

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars.

19058

-

-

... More
Thermo-Mechanically Treated bars.

19058

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars.

5161

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level

137

-

-

... More
All works above plinth level upto floor V level

27

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)

96.6

-

-

... More
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.as required. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

5

-

-

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).

773

-

-

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

773

-

-

... More
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)

1169.4

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats)

322

-

-

... More
Providing, Fixing,testing and commissioning of Sanitary fixtures & CP fittings including all accessories (ISI- marked , sample to be approved from client). The contractor rates to include for supply all Sanitary fixtures & CP fittings including fixing/supporting accessories like WC pan connectors, nuts, bolts, screws, hangers,bottle traps, rubber buffers, CI or MS brackets, anchor fastners, sealents, washers, adhesives,Flanges, plumber's tape, white cement, masking tape (if required for protection),clamps,m.s angles for support etc which are required for the successful installation of the fixtures/fittings including the steel shuttering in a neat workman like manner to the satisfaction of Project Manager. Rates are inclusive of Providing ,fixing ,testing and commissioning of Sanitary fixtures & CP fittings with all accessories at all the heights, depths and locations within the project premises. Rates are inclusive of Providing ,fixing ,testing and commissioning for underslung plumbing system or embeded piping, including all clamps & hooks including their painting to complete the work.Mostly, all the toilets in the residencial units have been designed for under slung piping. Rates are inclusive of provision of extension piece for final connection of CP fitting shall be supplied and installed by the contractor accordingly (as required) All pressure pipe will be tested on 1.5 times of the working pressure or as per CPWD specifications. SUB HEAD - I - SANITARY FIXTURES & FITTINGS: Consider all plumbing fixtures with following flow-rates at 3.1 bar or 45 psi pressure. Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

13

-

-

... More
One urinal basin with 5 litre white P.V.C. automatic flushing cistern

8

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer

14

-

-

... More
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

13

-

-

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

14

-

-

... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore

2

-

-

... More
Providing and fixing toilet paper holder : C.P. brass

13

-

-

... More
Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore

60

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore

49

-

-

... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

14

-

-

... More
Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.

8

-

-

... More
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

12

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes

29.55

-

-

... More
20 mm nominal outer dia Pipes

16.02

-

-

... More
25 mm nominal outer dia Pipes

32.78

-

-

... More
32 mm nominal outer dia Pipes

18.78

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal outer dia Pipes

6.99

-

-

... More
40 mm nominal outer dia Pipes

38.07

-

-

... More
50 mm nominal outer dia Pipes

48.83

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50 mm dia nominal bore

30

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

9

-

-

... More
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm nominal bore

1

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 450 x 450 mm

2

-

-

... More
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm dia

39.87

-

-

... More
200 mm Dia

32.66

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter S.W. pipe

39.87

-

-

... More
200 mm diameter S.W. pipe

32.66

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe

127.27

-

-

... More
250 mm dia. R.C.C. pipe

116.84

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

-

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

14

-

-

... More
Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

-

-

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, outside plastering with cement mortar 1:3(1 cement : 3 coarse sand), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with SFRC cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering ,excavation,refilling ,disposal of surplus earth in all kinds of soil,footrest etc. all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be including in this item.) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

-

-

... More
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

0.1

-

-

... More
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 250 to 300 mm diameter

1

-

-

... More
Providing, Fixing,testing and commissioning of 15 mm dia CP brass two way bib cock with flow 6 LPM (Litre per Minute) at 3.1 bar or 45 psi test pressure with C.P. wall flange of approved quality as approved by architect and complete in all respect.

13

-

-

... More
Providing & Fixing 3 star rating 10 Liter capacity storage type Electrical water Heater (Geyser) Vertical geyser including all accessories & complete in all respect.

1

-

-

... More
Providing & Fixing 3 star rating 15 Liter capacity storage type Electrical water Heater (Geyser) Vertical geyser including all accessories & complete in all respect.

3

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm dia

14.16

-

-

... More
50 mm dia

2.3

-

-

... More
65 mm dia.

48.64

-

-

... More
80 mm dia.

11.61

-

-

... More
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 32 mm dia.

1

-

-

... More
40 mm dia.

1

-

-

... More
50mm dia.

3

-

-

... More
Providing & fixing C.I butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 10 Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required as approved by architect and complete in all respect. 65 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
Providing and fixing electronic type level indicator for water tanks mounting in panel with the following features, level display, alarm when water level is low or high, full range from one level to two level display and manual reset for alarm etc. with electrical wiring conduit supports from wall & ceiling,float type sensor and all other accessories complete as required as approved by architect and complete in all respect.

2

-

-

... More
Providing, jointing, testing and fixing UPVC Soil, Waste & Vent system conforming to IS : 13592 and UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offset and other specials. Jointing shall be done with pushfit EPDM ring jointing technique in general. Solvent cement joints may be provided for fittings and specials which are not manufactured with pushfit rubber joints.Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection and also pipes may be laid / fixed in sunken floors, under slung from ceiling. The pipes laid in sunken floor shall be encased with not less than 75 mm thick cement concrete (1:2:4) all around.The installation shall be complete in all respects including cutting chases / holes in walls, slabs and making good the same as per specifications. (All major MS structure to hold the stack is included in this item) as approved by architect and complete in all respect. 110 OD Type B

177.3

-

-

... More
Providing, fixing, jointing, testing and commissioning UPVC (Class III) Rain water downtake pipe conforming to IS:4985 cut to required lengths including all necessary fittings and specials.UPVC fittings (moulded as well as fabricated) like bends, tees, Y-tees, crosses, boss connections, access pieces, saddle pieces, cleanouts, adaptors for connections to other materials, plugs, reducers, cowls, offsets and other specials. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting, chases / holes in floors / walls / slab and making good wherever required. (All major MS structure to hold the stack with fixing including anchor fasteners,sand,cement etc is included in this item). 160 mm dia

42

-

-

... More
Providing, fixing, jointing and testing UPVC soil, waste, vent pipework comprising UPVC pipe conforming to IS :4985-1983 of class 3 ( 6kg/cm2) as specified below and fittings (moulded as well as fabricated) like elbows, bends, reducers, threaded tail pieces, caps, suitable elbow with suitable extension piece for drain point and other specials jointing with cement solvent, chasing, cutting and making good the walls & floors pipes laid in floors shall be encased with 40 mm thick concrete all around, complete in all respects including testing of complete installation.(All major MS structure to hold the stack with fixing including anchor fasteners, sand, cement etc is included in this item) as approved by architect and complete in all respect. 40 mm dia 6 kg/cm2 (Class III )

10.92

-

-

... More
50 mm dia 6 kg/cm2 (Class III )

4.09

-

-

... More
63 mm dia 6 kg/cm2 (Class III )

17.6

-

-

... More
Providing and fixing UPVC/SWR trap (P trap) of self cleaning design as per IS:13592 : 1992 complete including cost of cutting and making good the cutouts in walls and floors etc.including cutting and making good the walls and floors wherever required complete as approved by architect and complete in all respect. as approved by architect and complete in all respect. 110 mm inlet and 110 mm outlet

20

-

-

... More
Providing and fixing floor drain made out of 110x63 mm OD uPVC. elbow connected to uPVC pipe complete as per direction of Project Manager as approved by architect and complete in all respect as approved by architect and complete in all respect.

14

-

-

... More
Providing and fixing Inlet Fitting for Urinal trap, formed out of 110 mm PVC pipe with multiple side inlets formed with saddle pieces, suitable for 40, 50 and 63 mm dia side connections as per standard detail and support through galvanized steel support from slab or set in cement concrete mix 1:2:4 including cutting and making good the walls and floors wherever required as approved by architect and complete in all respect..

3

-

-

... More
Providing and fixing Inlet Fitting for floor trap, formed out of 110 mm PVC pipe with multiple side inlets formed with saddle pieces, suitable for 40, 50 and 63 mm dia side connections as per standard detail and support through galvanized steel support from slab or set in cement concrete mix 1:2:4 including cutting and making good the walls and floors wherever required as approved by architect and complete in all respect..

17

-

-

... More
Providing and fixing Heavy Class SS grating of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT, UT & FD as approved by architect and complete in all respect.. Size 100 mm X 100 mm

34

-

-

... More
Providing and fixing P.V.C. WC connector (straight or bend type) with rubber lip ring. Including 110 mm dia PVC pipe / bend of required length and proper connection with M seal to C.I. pipe complete as required as approved by architect and complete in all respect..

13

-

-

... More
Providing and fixing cleaning eye 110mm dia on horizontal UPVC soil & waste pipes of 300 mm long UPVC pipe with one plain end lead caulked in to the collar of UPVC pipe and the other end with flange which in covered by neoprene rubber gasket and blank flange, complete with nuts, bolts etc and hot dip galvanization after fabrication to the satisfaction of Project Manager as approved by architect and complete in all respect.. 100 mm dia

9

-

-

... More
Providing and supplying 32 mm air realease valve for domestic loop line at terrace with complete in all respect as per Engineer in charge.

1

-

-

... More
Supply, assembly, erection, testing and commissioning of pumping system comprising the following: as approved by architect and complete in all respect. Vertical/Horizontal centrifugal pumps (1 Working + 1 Stand-by) with mechanical seal, SS Volute casing and SS impeller connected to suitable capacity TEFC induction motor suitable for 415 ± 10 % volts, 3 phase, 50 cycles A.C. supply with 100 mm dia. pressure gauges including MS skid and mounting of the pumps on the skid. (Motor to be of the same make as the pump) Raw Water Filter Feed Pump : Capacity : 50 LPM Each Pump (1 Working + 1 Standby) @ 20 M head. (location at UGT Plant room)

2

-

-

... More
Supply, assembly, erection, testing and commissioning of SS/CI submersible grinder type pumps, suitable to handle basement drainage having the following capacities, complete with 3 phase squirrel cage submersible motor of required HP for 415 ± 10% volts, 3 phase, 50 Hz. A.C. supply cooled by surrounding liquid, submersible cable upto main panel within the plant room, dry running preventor, G.I. guide pulling chain, all the necessary piping and accessories, valves, delivery header etc. as required complete in all respects. The rate will include electrical panel with cyclic operation as supplied by the manufacturers. The rate will also include a three level sensor, controller and level indication (low, mid and high) system with a sounder for high level. The pumps will start as follows: (a) At mid level pump 1 will start. (b) At high level pump2 will start and there will be a sounder alarm as approved by architect and complete in all respect. The above installation shall be complete with sump pump lifting assembly, ready made electro – galvanized MS lifting chain, GI pipe header complete with discharge manifold, flanges, tee, elbow etc. complete including GI pipe upto the top of sump and including GI union. Header shall be sized for both pump working under delivery velocity of 1.5 m/sec. Capacity of 195 lpm against a total head of 20m (solid handling 5-15 mm) (Basement Sewerage) (1 Working + 1 Stand by)/(4 sets) (SS Body and SS Impeller and shaft)

2

-

-

... More
Providing, fixing, jointing and testing in position the following medium class B G.I. pipes conforming to IS:1239 cut to required lengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, unions, reducers, flanges & plugs etc. fixing at wall/ceiling level supported by clamps, hangers etc, (to be galvanized after fabrication) cutting hole in wall/floor/slab and making good the same good with cement concrete 1:2:4 / fire sealant complete as approved by architect and complete in all respect.. 50 mm dia

150

-

-

... More
MULTIGRADE SAND FILTER (For Domestic supply) Supply, installation, testing & commissioning of vertical self supporting Dual Media Filter (DMF) fabricated from FRP as per IS : 2825, ASMI code, complete with pressure gauges at inlet & outlet, sample cock, PVC face piping with ABS multiport valves and all accessories, with initial charge of filter media for Dual media filter with multi grade quartz sand & anthracite, lining inside with PP and FRP wounded outside, testing and commissioning complete as approved by architect and complete in all respect.. Capacity : 2.5 M3 / Hr Filtration rate : 15 m3 / m2 / hr Height of shell : 3.5 Kg/Sq.cm Max. operating pressure : 3.5kg/sq.cm. Test pressure : 5.5kg/sq.cm dia of filter : .4 mtr Out Put Suspended solids : less than 5ppm Multi grade Sand Media (minimum) : 400kg Vessel Model : 18 x 65 Make : Pentari / Star lite

1

-

-

... More
ACTIVATED CARBON FILTER (For Domestic supply) Supply, Installation, testing & Commissioning of vertical self supporting Activated Carbon filter (ACF) fabricated from FRP as per IS: 2825, ASMI Code, Complete with pressure gauges at inlet & outlet ample cock PVC face piping with ABS multiport valves and all accessories with initial charge of filter media for Activated Carbon filter with anthracite (activated Carbon) , lining inside with PP and approved by architect and complete in all respect. Capacity : 2.5 M3 / Hr Filtration rate : 15 m3 / m2 / hr Height of shell : 3.5 Kg/Sq.cm Max. operating pressure : 3.5kg/sq.cm. Test pressure : 5.5kg/sq.cm dia of filter : .4 mtr Out Put Suspended solids : less than 5ppm Multi grade Sand Media (minimum) : 400kg Vessel Model : 18 x 65

1

-

-

... More
Supplying, assembly, erection, testing and commissioning of magnetic level sensors and controllers, CPVC probe tube, PP actuating float and all other equipment required for the performance of the system to the satisfaction of the engineer in charge complete including providing and fixing wiring from control junction box near the UG tank to probes of required length, interconnection wiring between level controller and the concerned contactor in the starter panel as required. The level controller will perform the following functions as approved by architect and complete in all respect..

1

-

-

... More
To switch on the pumps (including tube well pumps 2 nos., raw water pumps, Domestic Water Treatment, Softening Plant, Domestic, Flushing and Soft Water Makeup Tanks at Terrace etc.) when the level of water in the supply water tank is low and to cut off the pump when the level in the receiving water tank is high and switch off the pumps when the level of water in the supply water tank is low. To indicate 3 levels of water in all tanks through a control panel with LEDs To start the pumps in a cyclic order. The system shall be complete to ensure automatic quotation of pump in accordance to water level in respective tanks. The Contractor will include all the under ground and over head tanks and all the pumps as required for level control in this item Providing & fixing Electric control panel to open / close the solenoid valve at low / high water level through level controller in OH water tanks including wiring, level controller probes & other accessories as required to operate the system automatically, including providing motorized butterfly valves with weather proof enclosure valves of suitable size as approved by architect and complete in all respect..

1

-

-

... More
Providing, fixing, jointing and testing in position the following medium class G.I. pipes conforming to IS:1239 cut to required lengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, unions, reducers, flanges & plugs etc. fixing at wall/ceiling level supported by clamps, hangers etc, (to be galvanized after fabrication) cutting hole in wall/floor/slab and making good the same good with cement concrete 1:2:4 / fire sealant complete as approved by architect and complete in all respect.. 32 mm dia

10

-

-

... More
40 mm dia

10

-

-

... More
50 mm dia

10

-

-

... More
Providing two coats of Synthetic enamel paint of approved shade on pipes and supports as per pipe colour code over a coat of primer. Including painting of legends with direction arrow as approved by architect and complete in all respect. 32 mm dia

10

-

-

... More
40 mm dia

10

-

-

... More
50 mm dia

10

-

-

... More
Supply, installation, testing and commissioning of tanker inlet connection complete with 80 mm dia GI inlet piping, hose inlet connection, MS cabinet enclosure (epoxy painted after fabrication), pad locking arrangement, inlet flexible hose complete with all necessary arrangementas approved by architect and complete in all respect..

1

-

-

... More
Supply, assembly, erection, testing, and commissioning of chlorine dosing for a treated water completeas approved by architect and complete in all respect.. Flow rate 0-6 lph 100 LTE

1

-

-

... More
Providing and fixing Butter fly valve Rated for PN16 pressure rating including rubber gasket, flanges, nuts, bolts, washers & painting as approved by architect and complete in all respect.. 50 mm dia

6

-

-

... More
65 mm dia

2

-

-

... More
80 mm dia

2

-

-

... More
Providing & fixing C.I. dual plate type check valve tested to a pressure of 15Kg/sqcm. Including rubber gasket, flanges, union, nuts, bolts, washers & painting as approved by architect and complete in all respect.. 50 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
Providing & fixing C.I. 'Y' Strainer (screwed / flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flanges / union nuts, bolts & washers complete as required (on pump suction)as approved by architect and complete in all respect.. 50 mm dia .

3

-

-

... More
65 mm dia

2

-

-

... More
80 mm dia

1

-

-

... More
Providing and fixing in position of approved quality G.M. float valve with copper ball float and brass rods of required length suitable for pressure of 10 Kg/sqcm of the following sizesas approved by architect and complete in all respect.. 25 mm dia

2

-

-

... More
50 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
Providing & fixing in position Vane Type mechanical water flow meter for following pipe sizeas approved by architect and complete in all respect.. 50 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
Providing and fixing M.S. puddle flanges (fabricated of 750 mm long pipe pieces) to R.C.C. water tanks wall / slab. The entire fitting shall be hot dipped galvanized (Flanges shall confirm to BS10 Table E) as approved by architect and complete in all respect.. 25 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe). .

6

-

-

... More
40 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).

4

-

-

... More
50 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).

6

-

-

... More
65 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).

2

-

-

... More
80 mm dia (Flanged ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).

2

-

-

... More
Providing and fixing Expansion flexible bellows between existing puddle flange in water tank retaining wall and proposed puddle flanges as mentioned under item No. 3 above. The bellow flanges shall match with exiting puddle flanges at siteas approved by architect and complete in all respect.. 25 mm dia .

1

-

-

... More
32 mm dia

1

-

-

... More
40 mm dia

1

-

-

... More
50 mm dia

1

-

-

... More
65 mm dia

1

-

-

... More
80 mm dia

1

-

-

... More
Providing and fixing in position G.I. vent with brass mosquito proof coupling and air filter including return bend, complete as required. The entire fitting shall be hot dip galvanizedas approved by architect and complete in all respect.. 100 mm dia .

3

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

67.5

-

-

... More
Providing, testing & commissioning of dial type pressure gauge with pressure scale of 0 to 15 kg / cm2. Provision of isolation cock suitable for pressure of 15 kg / cum2 shall be included in cost.

6

-

-

... More
Supply complete testing kit with all chemicals complete suitable for conducting test on water quality. The test kit shall be suitable to measure TDS, pH, Hardness, Iron content and other parameters (Make : Ion Exchange)as approved by architect and complete in all respect..

1

-

-

... More
Any Additional Items wherever required will be from the APWD Schedule of Rtaes(SOR) for Civil, Sanitary & Water Supply and Electrical works including service connection etc. for 2013-14. Rates to be quoted at per or flat percentage basis i.e. ___________ % above/below the APWD SOR 2013-14 for Civil, Sanitary & Water Supply and Electrical works for any additional items not included in the above items. The amount for these items will be calulated out at per or percentage above below whichever is quoted by the Bidder over the amount against these items. Estimated Amount: Rs. 29,62,356.00

1

-

-

... More
FIRE FIGHTING SYSTEM Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head

1

-

-

... More
Fabricating, Supplying, Installation, Testing and Commissioning Air Vessel of continuous welded construction with flanged discharge header on the top of each riser fabricated out of 10 mm thick dished ends and 8 mm thick MS sheet, Air Release Valve complete with suitable drain arrangement with 25 mm dia gun metal wheel valve complete with all accessories etc. as required of the following sizes: 1.2 Meter high and 250 mm dia.

4

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

8

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)

8

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)

8

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m

8

-

-

... More
SITC weather proof M.S cabinet size 1200 mm x 600 mm x 250 mm Supplying, installation, testing and commissioning of weather proof M.S cabinet size 1200 mm x 2100 mm x 600mm deep fabricated from 1.6mm thick M.S. sheets and M.S angle 40mmx40mmx6mm complete with glass, locking arrangements to accommodate the following: - Gunmetal single headed Hydrant valve - 1 No. Fire Hoses 63mm, 15 M long with accessories - 2 Nos. Short branch - 1 No. First Aid hose Reel - 1 No. Fire Extinguisher - 2 Nos. Fireman's Axe - 1 No. Pressure Gauge - 1 No. The cabinet shall be painted with one coat of primer and 2 coats of synthetic enamel paint of approved shade.

8

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia

160

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia

2

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia

3

-

-

... More
Providing, Installation, Testing and Commissioning of Gun Metal / Bronze Ball Valves with brass body chrome plated of following sizes as required. 25 mm dia

8

-

-

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

8

-

-

... More
Supply, Installation, Testing and Commissioning of 150 mm dia Bourden type, Stainless Steel dial type Pressure Gauge including brass isolation valve and siphon pipe having calibration of 0 - 16 Kg / cm2

8

-

-

... More
Supplying and Fixing of Fire Man's axe with heavy insulated rubber as per standard conforming to IS 926

8

-

-

... More
Providing and fixing of ISI marked (IS:15638) portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets as required as per specifications. Extinguisher shall halon free.

8

-

-

... More
Providing and fixing fire extinguisher of carbon dioxide type consisting of brand new high pressure steel cylinder bearing IS: 7285 mark and having the approval of controller of explosives Nagpur, wheel type valve bearing IS:3224 mark internal discharge tube, 1 meter long high pressure discharge hose, non conducting horn, suspension bracket, fully charged bearing IS: making fixed to wall as directed.Extinguisher shall halon free. 4.5kg capacity cylinder

8

-

-

... More
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc as required. GROUP-C

100

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

2

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.

500

-

-

... More
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.

250

-

-

... More
Wiring for circuit/ submain wiring alongwith earh wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

400

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

200

-

-

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

20

-

-

... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

150

-

-

... More
4 X 6 sq. mm + 2 X 6 sq. mm earth wire

60

-

-

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire

60

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm

220

-

-

... More
4 x 1.5 sq. mm

110

-

-

... More
Supplying and drawing following pair, 0.5 mm dia FRLS PVC insulated copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair

150

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

1

-

-

... More
Supplying and fixing of following sizes of steel conduit along with accessories in surface/ recess including painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as required. 20 mm.

200

-

-

... More
25 mm.

100

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.(for Telefhone System) 20 mm.

100

-

-

... More
25 mm.

100

-

-

... More
32 mm.

30

-

-

... More
40 mm.

20

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet.

5

-

-

... More
TV antenna socket outlet

1

-

-

... More
Bell push

1

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

8

-

-

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm x 75mm)

8

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).

2

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required.

26

-

-

... More
Supplying and fixing call bell/ buzzer suitable for D.C./A.C. single phase, 230 volts, complete as required.

1

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

136

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required / Chandelier light fixture.

9

-

-

... More
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.

11

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.

11

-

-

... More
Supplying and drawingof UTP 4 pair CAT 6 LAN Cable in the existing surface / recessed steel / PVC conduit as required. 1 run of cable

60

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required GROUP-C

66

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2nos.3 pin 5/6 amps modular socket outlet and 2nos. 5/6 amps modular switch, connection, etc. as required. (For light plugs to be used in non residential buildings).

2

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door

1

-

-

... More
Supplying and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door

1

-

-

... More
6 way (4 + 18), Double door

2

-

-

... More
8 way (4 + 24), Double door

1

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole

78

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

2

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

1

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A

2

-

-

2

-

-

... More
Supplying and fixing 20amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps 'C' curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

6

-

-

... More
Supplying and fixing 20amps, 240 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 amps 'C' curve, TP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

1

-

-

... More
L.T.CABLE LAYING Laying and of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC / HUME / METAL pipe as required. Upto 35 sq. mm

20

-

-

... More
Above 35 sq. mm and upto 95 sq.mm

20

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm

630

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

40

-

-

... More
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm

673

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

40

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

175

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

20

-

-

... More
Supplying and making indoor end termination with brass compression gland and aluminium / Copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. ALUMINIUM CABLE (ARMOURED) 3.5 core 95 sq.mm XLPE

4

-

-

... More
4core 35 sq.mm XLPE

2

-

-

... More
4core 25 sq.mm XLPE

2

-

-

... More
4core 16 sq.mm XLPE

2

-

-

... More
4 core 10/6/4 sq.mm Alu. Armd Cable

6

-

-

... More
3 core 10/6/4 sq.mm Alu. Armd Cable

16

-

-

... More
2 core 10/6/4 sq.mm Alu. Armd Cable

56

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required (for MPP/FFP YLDB, EXT LIGHT-2NOS)

8

-

-

... More
Earthing with G.I.earth plate 600 mm X 600 mm X 6 mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7metre long etc. with charcoal/ coke and salt as required. (for DG BODY)

2

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7metre long etc. with charcoal/ coke and salt as required. (for DG SET , EPABX)

3

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLS on earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

40

-

-

... More
Providing & fixing 25mm x 5mm Copper strip on surface or in recess for connection etc as required.

20

-

-

... More
Providing & fixing 25mm x 5mm G.I strip on surface or in recess for connection etc as required.

60

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.

5

-

-

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

60

-

-

... More
Providing and fixing 6 SWG GI wire on suface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring /cable as required.

800

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 mm dia

40

-

-

... More
150 mm dia

60

-

-

... More
Supplying and embedding following dia G.I.pipe (meduim class) inpole collar / foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 32 mm dia

30

-

-

... More
40 mm dia

30

-

-

... More
CABLE RACK Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

500

-

-

... More
CABLE TRAY Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
200 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
200 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
225 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays Reducer with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
225 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

2

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. With 3 x 2.5 sq. mm FR PVC insulated copper conductor For 9 mtr. Single arm Pole ( 1No. x 9Mtr.= 9Mtr.) (9set)

81

-

-

... More
With 3 x 1.5 sq. mm FRLS PVC insulated copper conductor For 4.0mtr. Post top latern pole / Gate Light( 1No. x 4.0.Mtr.= 4.0Mtr.) (10sets)

40

-

-

... More
Providing and fixing circular / Hexagonal cast iron or M.S Sheet Box for ceiling fan clamp of internal dia 140 mm , 73 mm height top lid of 1.5 mm thick M.S Sheet with its top surface hacked for proper bonding , top lid shall be screwed into the cast iron / M.S sheet box by means of 3.3 mm dia round headed screws , one lock at the corners clamp shall be made of 12 mm dia M.S bar bent to shape as per standard drawing

9

-

-

... More
Supply and fixing of the following Telephone Tag Block made out of M.S sheets of 18 SWG thickness properly welded complete with all accessories such as Tag block, connector (KRONE make), mounting strips, tapped holes, fixing bolts, approved shad of paint after primer as per specifications. 10 Pair

2

-

-

... More
Supplying, wiring and connecting following pairs 0.6 mm dia twin core tinned copper conductor PVC insulated and sheathed Unarmoured telephone cables in existing pipes. 10 pair cable

30

-

-

... More
Same as 2.1 but 10 pair telephone cable of jelly filled Armored cable. in existing pipe.

60

-

-

... More
Supply and fixing following Data /Lan modular socket on the existing modular plate including connections but excluding modular plate etc. as required. RJ - 45 Socket.

2

-

-

... More
Supply of the following luminaires comprising of basic channel, holder, Electronic Ballast / Low Loss Copper Ballast (as mentioned in BOQ) starter, condenser, control gear box complete with decorative attachments, lamps etc. as per specification and as per catalogue number giving below Ceiling / Wall mounted 10 LED light fixture .Philips Cat No. BN021 LED 10S-6500 PSU GR S1 or equivalent.

24

-

-

... More
Ceiling / Wall mounted 20 LED light fixture .Philips Cat No. BN021 LED 20S PSU CW GR S2 or equivalent.

23

-

-

... More
Ceiling / Wall mounted 40 LED light fixture .Philips Cat No. BN100C LED 40S-6500 PSU L120GR or equivalent.

2

-

-

... More
Surface mounted ceiling 18W LED light fixture Philips Cat No. SM 251C LED 20S 6500 PSU WH.or equivalent.

20

-

-

... More
Surface mounted ceiling 15W LED light fixture Philips Cat No. SM 251C LED 16S 6500 PSU WH.or equivalent.

9

-

-

... More
Decorative recessed 32W LED light fixture Philips Cat No. RC380B LED 36S-6500 G4 L60 W60 PSU OD OC.

6

-

-

... More
Decorative recessed 15W LED Down light fixture Philips Cat No. DN394B LED 16S-6500 PSU WH (1200 Lumen) (Round shape)

24

-

-

... More
Ceiling / Wall mounted 40 LED light fixture .Philips Cat No. WT201C LED 40S-6500 PSU L120 or equivalent.

1

-

-

... More
Ceiling / Wall mounted 20 LED light fixture .Philips Cat No. WT201C LED 40S-6500 PSU L120 or equivalent.

1

-

-

... More
10Watt LED Bulk head light fixture Philips Cat No WT202W LED6S CW PSU SI PC or equivalent

2

-

-

... More
25W LED Post top lantern Bajaj: BLPTSP 25W LED NW LED

16

-

-

... More
70W LED Flood light fixture.Philips BVP120 LED 70 CW FG S1 PSU GR

4

-

-

... More
Philips BRP410 LED091 CW HE NS PC S2 PSU GR (91W, 9100 lumen) control gear as required.

7

-

-

... More
SUPPLY OF CEILING/ PROPELLER TYPE EXHAUST FANS (WITH GRAVITY LOUVERS) / CABIN FAN. 1200 mm sweep Ceiling fan.

9

-

-

... More
450 mm dia 900 RPM exhaust fan.

3

-

-

... More
380 mm dia 900 RPM exhaust fan.

8

-

-

... More
L.T. PANELS : Supply and erection of all interconnections, small wiring, testing & commissioning of the following cubical type panels made of 14 guage CRCA structure, base channel, complete with, moulded case circuit breakers, meters, indicating lamps, current transformer etc. Complete in all respects, insulated bus bars with heat shrinkable PVC sleeve in suitable bus chambers, interconnection, small wiring, name plate, danger plate, earth bus etc. & comprising of compartments with hinged door for each feeder & its accessories, cable alley with hinged doors, bus chamber with bolted door etc. The panel being of dust & vermin proof construction with rubber gasket attractively powder coated with Siemens grey shade and having orange peel finish etc. The panel shall be free standing type/ wall mounted type as per relavant drawing and comprising with the following. Degree of protection IP: 54 Note:- Breaking Capacity of all MCCB's are Ics Service Breaking Capacity. MCCB's upto 250A shall be with Adjustable thermal-magnetic and above 250A Microprocessor based Adjustable release. MCCBs for Incomers shall have in built O/C, S/C and E/F protection and for MCCBs for Outgoing feeders shall have in built O/C and S/C protection. All MCCB's shall be with Extended type Front door operating handle, Phase Spreaders & Phase Barriers. The current density of bus bars shall be minimum 0.8A/ Sqmm for Aluminium bus Bars and 1.6 A / Sqmm for Copper bus bars. The maximum temperature rise of the bus bars and any joint shall not exceed 30⁰C above an ambient of 45⁰C. The Current Transformers burden shall be 5VA upto 250A & 15 VA above 250A, accuracy class 1.0 for metering and class 5P10 for protection. CTs shall be "CAST RESIN" type . All indication lights shall be LED type. All meter shall be "DIGITAL" type. Degree of Protection for panels shall be IP:54 for indoor panels and IP:55 for out door panels. "ON" Indicating lamp shall be provided for all 3 phase MCCB out going feeders unless otherwise specified. Control SP MCB's of 2 / 4A Rating shall be provided for each metering circuit. MAIN POWER PANEL

1

-

-

... More
INCOMING : 1 No.200A, TP+N MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. 1No.200A 4P ON Load Change Over Switch BUS BAR : One set of 250A FP Alu. Bus Bar with PVC Sleeve in sealed M.S. Painted Bus Chamber. METERING & INDICATIONS 1 Set of R/ Y/ B phase indication lamp with control MCB's. 1 no. Multi Function Meters with RS485 (V, A, F, PF) With CT and control MCB's(EM6436) OUTGOING : 1 no. 125A TP+N MCCB (25KA) with T. M. Rel. For O/C & S/C Prot. 2 nos. 100A TP+N MCCB (25KA) with T. M. Rel. For O/C & S/C Prot. 2 nos. 40A TP+N MCCB (25KA) with T. M. Rel. For O/C & S/C Prot. 3 Nos. 63A FP MCB (10KA) C-Curve 4 Nos. 40A FP MCB (10KA) C-Curve 1 No. 40A DP MCB (10KA) C-Curve 25 x 6 mm. G.I. Earth Bus across the width of the panel. WATER PUMP PANEL

1

-

-

... More
INCOMING : 1 No. 100.A, TP+N MCCB (25KA) with inbuilt Thermal Magnatic based release for Over load, Short circuit & Earth Fault protection. BUS BAR : One set of 150 A TPN ALu. Bus Bar, 25kA with PVC Sleeve in sealed Powder Coated Bus Chamber. METERING AND INDICATIONS 1 set of R/Y/B phase indication Lamp & MCB. 1 no. Multi Function Meters with RS485 (V, A, F, PF) With CT and control MCB's(EM6436) OUTGOING : 2 Nos. 40/32A TP N MCCB (25KA) 2 Nos. STAR/DELTA Starter(12 HP/9kw) Complete with 40A TP MCCB Suitable Rating Contactor & O/L Relay according to type -2 co-ordination, current sensing single phasing preventor, Ammeter with 1 C.T., Start/Stop Push Button, ON/OFF/TRIP indication Lamps, control MCB 2A and associate wiring as required. 2 Nos. DOL Starter(2.5 HP/1.9kw) Complete with 40A TP MCCB Suitable Rating Contactor & O/L Relay according to type -2 co-ordination, current sensing single phasing preventor, Ammeter with 1 C.T., Start/Stop Push Button, ON/OFF/TRIP indication Lamps, control MCB 2A and associate wiring as required. 2 Nos. DOL Starter(1.5 HP/1.1kw) Complete with 40A TP MCCB Suitable Rating Contactor & O/L Relay according to type -2 co-ordination, current sensing single phasing preventor, Ammeter with 1 C.T., Start/Stop Push Button, ON/OFF/TRIP indication Lamps, control MCB 2A and associate wiring as required. 25 x 6 mm AL. earth bus across the width of panel YLDB ( EXTERNAL LIGHTING DB,OUT DOOR TYPE ) (NEAR GUARD ROOM) Supplying, receiving, stroing, handling, testing and commissioning of following Cabinet type original factory fabricated distribution board 16 guage rust inhibited and baked enamel painted sheet steel and comprising of incoming MCCB, bus bar (Copper), neutral bus bar or links, top & bottom detachable vonduit entry plates, earthing terminals with bolts grouting & locking facility etc. Complete as per specification & comprising with the followings.

1

-

-

... More
40A TP MCCB (25KA) 40A TP Power Contactor. Electronic Timer (for 24 hours) Auto / manual Switch Push button (ON / OFF) Indicating lamps (ON / OFF) 8 Nos. 20 A DP MCB (10kA) 2 Nos.32 A DP MCB (10kA) Before Contactor.& Timer 6A SP MCB (10KA) for control ckt. Internal wiring L.T. CABLES (SUPPLY) Supply of the following 1100 Volts Alu/ Cu. Conductor, PVC insulated PVC sheathed, steel armoured/ unarmoured or XLPE cables as per IS-1554/ 7098 Part- I and as per standard specification ALUMINIUM CABLES (ARMOURED) 3.5 core 95 sq.mm XLPE

120

-

-

... More
4 core 35 sq.mm XLPE

50

-

-

... More
4 core 25 sq.mm XLPE

40

-

-

... More
4 core 16 sq.mm XLPE

60

-

-

... More
4 core 10 sq. mm. XLPE

30

-

-

... More
4 core 6 sq. mm. XLPE

70

-

-

... More
3 core 10 sq.mm XLPE

60

-

-

... More
3 core 6 sq.mm XLPE

60

-

-

... More
3 core 4 sq.mm XLPE

60

-

-

... More
2 core 10 sq. mm. XLPE

543

-

-

... More
2 core 6 sq. mm. XLPE

275

-

-

... More
DANGER BOARD/SHOCK RESTRORATION CHART ETC. Supplying and fix of standard shock restoration chart in heavy wooden frame with 3 mm thick plane glass.

1

-

-

... More
Supply and fix Danger Board indicating the voltage. 440V Danger Board

1

-

-

... More
Supply & laying of insulating mates as per IS15652-2006 (1.0 m wide) Suitable for 1.1 KV Class-A (2.0 mm thick) insulating mate

4

-

-

... More
AUTOMATIC FIRE ALARM AND DETECTION SYSTEM The work shall comprise of design, supply, erection, testing and commissioning of the entire system as per specification and drawings and comprising of smoke detectors heat detectors, photocell detectors, control panels, manual call points, hooters etc. including, fixing, accessories, cabling, fixing and mounting arrangement of components and equipment, making holes in wall/ ceilings for passages of cables & making good the same, proper saddles for fixing of cables as required to complete the job in first class workman like manner. (Approved makes of Material : System Sensor / Agni) The testing & commissioning of fire alarm system shall be carried out by authorized dealer/ company of equipment manufactures. The fire alarm system shall be connect with PA system. Panel shall be extendable Type. The system shall have UL / EN certification. Detectors Heat Detector Supply installation testing and commissioning of Rate of rise cum fixed temperature heat detectors with LED lamps base etc. as per specifications.

1

-

-

... More
Smoke Detector Supply installation testing and commissioning of Photo-Thermal type Smoke detectors 12 / 24 volt D.C., visual alarm indicators (LED's) "Blink - Red" in stand by and "Steady - red" in alarm complete in all respects with base as required.

19

-

-

... More
Response Indicator Supply, Installation, Testing & Commissioning of response indicator with plastic cover and transparent LED which shall glow red in case of fire with MS box on wall / Ceiling including connections etc

5

-

-

... More
Supply, Installation, Testing & Commissioning of response indicator with plastic cover and transparent LED which shall glow red in case of fire without MS box on wall / Ceiling including connections etc.

1

-

-

... More
Manual break glass type call points switch cast aluminium housing, telephone socket, hammer and chain as per specifications.

1

-

-

... More
Providing, fixing, testing and commissioning of dual tone electronic wailing tone fire alarm sounder having Philips 4" round/8 ohms speaker & oscillator amplifier, all housed in 16swg CRCA sheet metallic box, with suitable 19mm/16swg metallic conduit top and back entry knokout arrangement.

1

-

-

... More
Automatic Fire Alarm Pane Providing, fixing, testing and commissioning of main control panel of 2 zones as per IS-2189 with battery and charger. Each and every zone should have of visual indication like isolation, fire open circuit in detector, circuit fire alarm acknowledge fault alarm acknowledge, the main panel should be housed in 16swg CRCA sheet enclouser with front door having lock and key. Each and every zone should have the following switches Isolation, fire test, open circuit test, short circuit test, fire alarm acknowledge fault alarm acknowledge alarm test, the power supply should be heavy duty with suitable size battery charger with 12 hours backup Dry maintenance free battery. The panel will have AC switch, AC/DC fuse, indication, Battery low indication. The panels shall have a facility of tripping of AC units.

1

-

-

... More
Fire Exit sign board with 5W LED lamp with fixing/hanging arrangement including wiring & termination (as per sample approved)

1

-

-

... More
OUTDOOR LIGHTING POLES Supplying, Installation , testing and commissioning of outdoor lighting with fabricated pole made of MS pipe ( medium class) complete with base plate, luminaire bracket arm bed concrete foundation in 1:3: 6 ratio (1cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) including excavation and refiling , painting of Poles with one coat of primer and two coats of approved synthetics enamel paint etc. as required 9 mtr.high steel tubular pole with 450 x 450 x 10 mm thick base plate. Outside dia and thickness of sections of the pole shall be at bottom 139.7mm x 4.85mm , middle 114.3mm x 4.50mm & top 88.9mm x 3.25mm. Single arm Pole (Apprx. Weight 125kg)

9

-

-

... More
4.0 meter, Mild steel Pole for post top lantern (ISI marked) with 76.1mm O/D and 3.65 mm thickness and with 300 x 300 x6 mm thick base plate.

10

-

-

... More
40 mm dia & 0.6 M long GI pipe for gate light

4

-

-

... More
POLES MOUNTING BOXES : Supply and fixing of Thermoplastic type water proof pole mounting boxes of size 200 x 160 mm x 98mm, with cover and Gasket with cable entry knock outs, 4 way 20A connectors & 6A SP MCB mounted inside box etc.as per design including mounting arrangements. (Box depth 98mm)

23

-

-

... More
UV Disinfection For Main Pool 50 m x 25 m Low Pressure UV Lamp and Hight output Made of SS316L , Max. Flow Rate : 125 m3/hr UV Dosage : 30mj/cm2, UV Lamp : Number Power Consumption : 6 x87 w , with connection size for inlet & outlet : DN 150, Diameter : 273 mm Length of UV in mm : 1339 Max. working pressure : PN10, Lamp Life EOD : 13000 hrs Make : BIO UV-AtecPool

4

-

-

... More
UPVC Butterfly valves with Valve kit Ø 160 mm

12

-

-

... More
3 core PVC Copper cable for Pumps 2.5 mm2

60

-

-

... More
To be added in Main Pool Panel with all electrical acessories for UV system ( 04 nos.)

1

-

-

... More
Supervision of Erection & Commissioning of UV Disinfection

1

-

-

... More
POOL DIMENSIONS: 50.03M (L), 25 M (W) x 2.0 Avg. Water Depth VOLUME : 2500 M³ TURN OVER PERIOD : 6.0 Hrs FILTRATION FLOW : 400 M³/Hr FILTRATION VELOCITY : 40M³/Hr/M² BALANCE TANK CAPACITY : 75M3 ( 10.0 m x 6.0 m x 2.0 m ) Filters (Vertical Type) TOTALLY NON-CORROSIVE Filter made of Fibreglass and reinforced with Bobbin wound polyester yarn. Fitted with collector arms and diffusers made from unplasticised PVC and Polypropelene. Hub for holding the collector arms should be made of Stainless Steel. Filter Diameter 1800 mm. (The diameter should be minimum 1800mm as measured at any point of the Height On Straight). Flanged Connection for inlet & outlet : 160mm Manhole lid: 360 mm dia Media Bed depth 1000mm Working pressure 2.5kg/cm2, (37.5 PSI), Test pressure 3.75 kg/cm2 (56.25 PSI). Flow rate of 100 m³/hour at a specific velocity of 40m³/hr/m². Filter to be supplied complete with lid in polyester resin and fibre glass,filter internals,manual air purge cap, for sand discharge, presure gauge. Make: AtecPool Espana

4

-

-

... More
Manually operated 5 Valve batteries built entirely in PVC/PN-10 with 160mm flanged connections to filters.

4

-

-

... More
Butterfly valves also in PVC. Supports & Clamps made of SS Pipes

4

-

-

... More
Silica sand media for filter with granulometry between 0.4 and 0.8mm Make : Indeginouse

14400

-

-

... More
Gravel for filter with granulometry between 1-2 mm Make : Indeginouse

4000

-

-

... More
High flow plastic Horizontal Centrifugal pumps with Inbuilt strainer.

4

-

-

... More
Body is made of cast Iron Prefilter body in Cast Iron Basket made of stainless steel with lid Pre-filter is closed with knob system of easy acessibilty connection size 100 mm x 65 mm Shaft : Made of AISI SS 304 Mechanical seal : made of graphie/Ceramic Impeller : Made of HT 200 ,Capacity : 10 HP,Motor 2850 rpm, IP 55 , 50 Hz Electrical Protection : IP55 Capable of delivering 100 m³/hr @ 12 m head and shut off head not exceeding 2.5kg/cm2 Duty 4 nos. Make: AtecPool Espana The maxium system Flow rate shall not exceed the flow rating of any listed ( per IAPMO Listed) suction outlet cover installed 18" x 18" : Grate with frame in ABS plastic white color. VGB 2008 & UL. Total open area : 155.6 sq.in. Frame size : 18" x 18". Floor flow rate : 424 gpm @ 1.5 ft/sec Make: AtecPool/CMP

2

-

-

... More
Suction inlet in white ABS with cap internal 50mm glue connection Make: AtecPool Espana

8

-

-

... More
White ABS plastic bottom inlet for concrete with S.S. screws and regulable flow. Max flow 9 m3/hr. Connection: Outside/ inside dia 50mm Glue Make: AtecPool Espana

96

-

-

... More
Chemical Dosing system for pH and Chlorine Electromagnetic dosing pump in Polypropylene, IP 65 protection.

8

-

-

... More
Maximum Flow 10.0 lph at 4/5 bar. 0-100% manual flow adjustment.180 strokes / minute. Make: ATecPool -Aqua/Edose Dosing Tanks Semi transparent polyurethane tank for feeding chemicals to the dosing pumps.100lts capacity. Make: AtecPool Espana

8

-

-

... More
Overflow Type Ladders Overflow Commerical Pool Ladder Ø 43 mm x 1.2 mm tube in Stainless steel 316 shiny polish finishing , different kind of tread always fixed to the handrail with hiddin screws ,Double safety tread , 5 step ladder Make: AtecPool Espana

6

-

-

... More
Grating & Grating Profile for swimming Pool White Color Modular Gratings made in UV stabilized ABS. With Anti-spill design Snaps together on central spine thus enabling a flexible continuous run.45 units per meter, Ht.22 or 35 mm, width: 295 mm Make: AtecPool Espana

105

-

-

... More
UNDER WATER LIGHTS 50 W, 12V LED Warm white underwater light, niche type with Electrolysed stainless steel body ( SS316) and niche in PP. supplied 3.6 meter STOWHO7RN-F cable. The light shall be fitted/ removed with the use of SS screws to avoid coming loose like push fit lights. The lights shall be CE compliant. Make: AtecPool Espana

32

-

-

... More
Deck box made in white ABS with three threaded outlets. Make: AtecPool Espana

32

-

-

... More
Flexible conduit for carrying cable from underwater light to deck box. 1.5Meter length, threaded ends 3/4" & PG-16 Make: AtecPool Espana

32

-

-

... More
Transformers for underwater lights, 300 VA. Step down to 220V to 12/14/16V , IP 67 Make: AtecPool Espana

8

-

-

... More
MAINTENANCE ACCESSORIES Anodised aluminum double vacuum head (760 mm width) with 1-1/2" connection with handle with clip type Make: AtecPool Espana

1

-

-

... More
Extensible handles for cleaning attachments in anodized aluminium which can be adapted to the entire range of cleaning equipment, brushes, leaf skimmers and scoops.13 mts. Long Make: AtecPool/AST

1

-

-

... More
Transparent blue Copolymer Floating vacuum hose 1.5" dia (40mm) 30 mtrs long. Including hose cuffs for connection to suction inlets. Make: AtecPool Espana

1

-

-

... More
Deep bag net made in polypropelene and white polyester netting clip type connection Make: AtecPool Espana

1

-

-

... More
Surface net made in polypropelene and white polyester netting clip type connection Make: AtecPool Espana

1

-

-

... More
Curved brushes made in polypropelene for pool basins and scum liners clip type connection Make: AtecPool,

1

-

-

... More
Straight brushes with stainless steel bristles Make: AtecPool Espana

1

-

-

... More
Reinforced aluminium telescopic handle 2.4 - 4.8M long with clip type connection Make: AtecPool Espana

1

-

-

... More
Algae Brush with Aluminium back and S. S. bristles, fixing with clip connection. Make: AtecPool Espana

1

-

-

... More
Test Kit for pH & Chlorine Make: AtecPool Espana

2

-

-

... More
Supply and Installation of following uPVC pipes 10 bar pressure Ø200 mm

120

-

-

... More
Ø160 mm

200

-

-

... More
Ø110 mm

100

-

-

... More
Ø90 mm

48

-

-

... More
Ø75 mm

48

-

-

... More
Ø63 mm

200

-

-

... More
Ø50 mm

48

-

-

... More
Paddle Flange ( IN uPVC) Ø 200 mm for overflow from channel & B.tank inlet

12

-

-

... More
Ø 160 mm for inlets & backwash

9

-

-

... More
Ø 200 mm from B.Tank to pump suction header

4

-

-

... More
Ø 200 mm for Overflow of B.Tank

2

-

-

... More
Ø 110 mm for drain pipe

4

-

-

... More
Ø 63 mm for vacuum point ,B.Tank drain & make up

10

-

-

... More
Ø 50 mm for B.Tank drain & make up

2

-

-

... More
Ø 50 mm for cables

6

-

-

... More
uPVC VALVES : All valves shall be of PIMTAS/COROPLAST /Equivalent brand of minimum PN10 rating. Butterfly valve with flange adaptor & backing ring of Ø 110 mm dia for Main drain

2

-

-

... More
Butterfly valve with flange adaptor & backing ring of Ø160 mm dia for Inlet line

4

-

-

... More
Butterfly valve with flange adaptor & backing ring including nuts & bolts of Ø200mm/Ø160mm dia for pump suction & delivery lines (set)

4

-

-

... More
Butterfly valve with flange adaptor & backing ring including nuts & bolts of Ø 200 mm. From balancing tank to pump suction header

4

-

-

... More
Ball valve solvent type of Ø 63 mm dia form Vacuum line, drain & make up

3

-

-

... More
Flap type Non-return valves with assembly kit Ø 200 mm for pool balancing tank to pump suction header

2

-

-

... More
Flap type Non-return valves with assembly kit Ø 160 mm for inlet pipe

4

-

-

... More
Flap Type Non-return valves with assembly kit Ø160mm for backwash & pump discharge line

8

-

-

... More
Control panel and electrical/control wiring including providing and fixing dust and verin proof cubicle type motor control center fabricated from 16 S.W.G. for body, 14 S.W.G. for door as per IP52, duly powder caoted finish and comprising of adequate capacity MCBs,MCCBs, cyclic timer, overload relays, push button start, ameter, voltmeter, appropriate etched plastic idetification plate for each starter/switch colour coaded internal wiring from incoming main switch gear, starters, indicating lamps, phase preventer , heater for panel, fresh/exhaust air fan with filter . complete in all respects(For Filter -Recircualtion pump (04 nos.) , Dosing pumps ( 8 nos.) , Underwater light MCB ( 8 nos.) , RCCB for U/W Lights ( Note : we will have 2 small Panel for U/W Light at Length side at centre of Lenght side max. 6 m away from swimming pool wall)

1

-

-

... More
Rigid PVC conduit ( Heavy) color Ivory/Black Ø 25 mm in mtrs

850

-

-

... More
All the electrical cables for Underwater lights 2 core PVC insulated FR PVC round shealded copper cable from junction/deck box to light panel. 2.5 mm2

550

-

-

... More
4.0 mm2

400

-

-

... More
3 core PVC insulated FR PVC round shealded Copper cable for dosing pumps 2.5 mm2

150

-

-

... More
4 core PVC armoured Copper cable for Pumps 6.0 mm2

70

-

-

... More
Perforated GI cable tray 1.6 mm thick , 40 x 150 x 40 mm width

100

-

-

... More
GI Earthing strip/Wire clampled to the wall, cable tray complete as required including interconnection between length at joints all fixing acessreis saddles, clamp etc 8 SWG wire

70

-

-

... More
MS channel of 150 mm with Paint for pipe support at floor with anchor fastner

1

-

-

... More
Rubber Expansion Joints Neoprene lined single unfilled arch Intergral rubber flanges on both sides with split retaining rings (SRR)+ Control Unit ( CU), working pressure : 10 bar , Test pressure : 16 bar, temp. : -10 to 70 C, Medium : water Pump discharge side Ø 150 mm ( N.B) Make : RESISTOFLEX

4

-

-

... More
Intial chemical charge for 1 month start up of swimming pool based in 12 hours running

1

-

-

... More
Hammer Drive Anchor Fastener 12 x 100 mm Steel Zinc Plated in nos.

200

-

-

... More
Supervision of Erection & Commissioning of Mechanical Equipments

1

-

-

... More
MIDI 110 mm float lines 50 M long with orange and white floats. To be supplied complete with float line tensioners and anchorings on either side of the pool. The anchors shall be made of SS 316 and suitable for a pool with 2 sides overflow All discs are made from UV stabilised co-polymer polypropylne and floats are from high density polythylene. Cable is SS 316 with diamter of 3.1 mm and max force of 5 Kn. Standard colours : red 5 m ends white & blue alternating. 50 mtr lans have marks at the 15 m position

10

-

-

... More
The anchors shall be made of SS 316 and on either side of the pool.The anchors shall be made of SS 316 and suitable for a pool with 2 sides overflow Make: AtecPool/Anti

20

-

-

... More
The storeel is made from stainless steel with stainless steel castors. Protect your Anti wave racing lanes with the original Anti wave stoReel.Produced from top quality corrossion resistant poder coated aluminium. One roller will Hold min. 3 lanes of MIDI 110 mm ( 50 mtr) dia. 1000 mm x 1200 mm height wheels and 2/4 wheels fitted with brakes. Make: AtecPool

4

-

-

... More
Starting Block is designed for the requirment of most normal competition & training pools. Provides a high quality and long lasting starting block Dimension : 500 mm x 500 mm x 450 mm Height. Top of block are Hand-laid fiberglass while fitting are 316 Stainless steel. Dynaset drop-in anchors included. The top surface of Anti skid starting block. Make: AtecPool

10

-

-

... More
The anti wave back stroke set contains a complete set of poles, flags, lines & fittings Supplied with sufficient deck hole anchors for insatalltion. Pole and deck anchors are made of SS 316 Height 2.0 m & Ø 48.30 mm with 1.6 mm thickness Top of the poles are made from engineering plastic. Make: AtecPool/Anti

2

-

-

... More
The anti wave False stroke set contains a complete set of poles with Jawa , red rope , deck holes Supplied with sufficient deck hole anchors for insatalltion. Pole and deck anchors are made of SS 316 Height 2.0 m & Ø 48.30 mm with 1.6 mm thickness Top of the poles are made from engineering plastic. Make : AtecPool/Anti

1

-

-

... More
The deck anchors shall be made of SS 316 and on deck for False & Back stroke Indicator. Ø 48.3 mm x 120 mm Make: AtecPool/Anti

6

-

-

... More
The GRP caddy lane saver prevents lane damage from sharp edges during removal of lanes from pool to stoReel & re-insatalltion Make: AtecPool/Anti

1

-

-

... More
Life Safety Equipments 60 cm life ring with polyethelne ( orange color) Make : AtecPool

4

-

-

... More
Lifehook with aluminium handle 3.3m Make : AtecPool

1

-

-

... More
The anti life guard chair provides a pratical vantage point for life guard duties. Made os stainless steel construction allows the chair to be moved and stored with ease. Height 1800 mm Make : AtecPool

1

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth lead upto 50 metres.

216

-

-

... More
Construction of Embankment with material Deposited from Roadway cutting (Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)

216

-

-

... More
Granular Sub-Base with Coarse Graded Material (Table:-400-2) ( Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface , mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density complete as per cl.401 for grading -I Material

54

-

-

... More
for grading -II Material

54

-

-

... More
Water Bound Macadam (Providing,laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding material to fillup the interstices of coarse aggregate, watering and compacting to the reqd. density (with an initial lead of 5.0 km.) By Manual Means Grading I Using Screening Type-A (13.2mm Agg.)

108

-

-

... More
Grading Using Screening Type-B (11.2mm Agg.)

108

-

-

... More
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).

108

-

-

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars.

2160

-

-

... More
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Grade 'A' sealing compound. Grade 'A' sealing compound.

1008

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

24

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter

8

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe

32.8

-

-

... More
Providing and laying interlocking Concrete Block Pavement (ICBP) conforming to IS:15658-2006 including all lead and lift 80 mm interlocking precast blocks having compressive strength of 40N/sqmm

412.5

-

-

... More
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

50

-

-

... More
Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing, specification and direction of Engineer-in-charge. Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm

1

-

-

... More
Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm

1

-

-

... More
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. New Work ( Two or more coats)

10.09

-

-

... More
Providing grooves in CC road of 5 mm width and 50 mm depth as per architecture drawing and design as approved by architect and complete in all respect..

144

-

-

... More
FOR HORTICULTURE & PLANTATION Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil

169.44

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

169.44

-

-

... More
LANDSCAPE Supplying and stacking of good earth at site including royalty and carriage up to 5 km (earth measured in stacks will be reduced by 20% for payment).

75

-

-

... More
Supplying and stacking sludge at site including royalty and carriage up to 5 km (sludge measured in stacks will be reduced by 8% for payment).

37.5

-

-

... More
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm

37.5

-

-

... More
Fine dressing of the ground.

500

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

150

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge..

150

-

-

... More
Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the good earth shall be paid for separately). In rows 5 cm apart in both directionS

500

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 90 cm dia, and 90 cm deep

1000

-

-

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).

108

-

-

... More
Complete maintaince of the entire garden features in the garden area i.e. lawn trees, shurbs, hedges, flower beds, creepers etc. including hoeing, pruning replacements of plants, gap filling, watering, mowing of lawn, clipping of hedges, removal of garden waste, applying inseticide, pesticide & fertilizer(whenever required) top dressing of lawn with good earth and manure and maintenace of other garden related works for 12 months (1 year) as directed by officer-in-charge. (Note:-Good earth, maure, fertilizer, insecticide, pesticide etc & all T&P articles & stock material will be provided bt the department.) Open spaces(as per yard stick 1Mali =3.00Acre).

6000

-

-

... More
Supply and stacking of selection No. 1 doob grass at the fresh & fre from weeds having proper roots.

2500

-

-

... More
Providing and Displaying plants Budded Rose (H.T. variety) 3 to 4 healthy branch 30 cm and above ht. well developed with one and above flower plant in 20 cm Earthen Pot, as per direction of the officer-in-charge.

50

-

-

... More
Providing and Displaying plants Creeper Rose variety 3 to 4 healthy branch 60 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.

50

-

-

... More
Providing and Displaying plants Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.

50

-

-

... More
Timber and Flowering tree Supply and stacking of Grevillea robusta (Silver Oak) plant of height 150- 165 cm. in big poly bags of size 25 cm as per direction of the officer-incharge

25

-

-

... More
Supply and stacking of Polyalthia longifolia (Ashok) plant of height 150- 165 cm. in earthen pots of size 25 cm as per direction of the officer-incharge.

25

-

-

... More
Supply and stacking of Acacia auriculiformis (Amaltas) plant of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge.

10

-

-

... More
Supply and stacking of Millingtonia hortensis plant of height 150-165 cm.in big poly bag of size 25 cm as per direction of the officer-in-charge.v

10

-

-

... More
Supply and stacking of Spathodea campanulata plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.

10

-

-

... More
Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge

10

-

-

... More
BOREWELL Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All type of soil 300 mm dia

160

-

-

... More
Rocky strata including Boulders 300 mm dia

20

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders 300 mm dia

120

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia

160

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia

120

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

8.83

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

10

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.

15

-

-

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

15

-

-

... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

48

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 dia

2

-

-

... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 dia

2

-

-

... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 dia

2

-

-

... More
Rain Water Harvesting Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kind of Soil

79.98

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

1087

-

-

... More
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil from 1.5 mtr to 3.0 mtr

18

-

-

... More
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil From 3.0 mtr to 4.5 mtr

18

-

-

... More
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil From 4.5 mtr to 6.0 mtr

11

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

0.87

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts, etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 Cement : 1.5 coarse sand (Zone-III) dervied from natural sources : 3 graded stone aggregate 20 mm nominal size) dervied from natural sources

1.03

-

-

... More
Centering & shuttering including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platform.

6.59

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars.

113.3

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)

25.83

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata,preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia

20

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer –in-charge 100 mm nominal size dia

20

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia

6

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

2.12

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

2.12

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer –in-charge.

2.12

-

-

... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

0.53

-

-

... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm dia

1

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

20

-

-

... More
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg

3

-

-

... More
Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.as required. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

100

-

-

... More
Providing and fixing SS grating complete as per drawing, approval and instructions of the Engineer-in-charge.

1

-

-

... More
Sewage Treatment Plant shall include the following MSEP Prefabricated Tanks, Walkway . Anoxic Tank 1.5 KL

1

-

-

... More
Aeration Tank Cum MBR Tank 3 KL

1

-

-

... More
Sludge holding Tank 1.5 KL

1

-

-

... More
Treated Water Tank 4 KL

1

-

-

... More
Supply, installation, testing & commissioning of SS screen perforated 6-8 mm 1 No. & perforated 3-2mm 1 No. size of both screen is 700x800 mm

2

-

-

... More
Supply, installation, testing & commissioning of level Switch and controller for automatic operation of the system with high/low level alarm with low level stop and high level start logic.

2

-

-

... More
Supply, installation, testing & commissioning of non clogging type pumps complete with all accessories, motor of required capacity. Delivery header with isolation valve, level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty: Submersible Raw sewage Transfer Pumps ( 2Nos. -2working & 1 standby) , Flow rate (each) = 2m3/hr MOC : CI Head = 08-10 Mtr ( pumps for transfering Sewage from equilisation tank. To MBBR Tank Solid Handling size 30-40mm) Make:Wilo/CRI/KSB/CG

2

-

-

... More
Sludge Recircualtion Pumps with CI body & CI impeller pump 1 working Make: Make:Wilo/CRI/KSB/CG Capacity : 2 m3/hr Head : 8-10 M (Solid handling size for above pumps shall be 10mm). Air diffusion system shall include the following:

2

-

-

... More
2 Nos. Twin type rotary air blowers (Two working & one standby) capable of delivering 20m3/hr of free air at 0.4 kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP, Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. Make: Ingersoll rand/Kay/Everest

2

-

-

... More
Air piping shall comprise of pipes with MSEP Header complete with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports & clamps, etc cutting chases & making good. Contactor to submit detailed P & I indicating their proposal

1

-

-

... More
Non clog type air retrieval diffussion(EPDM) system capable of handling 5-8 cfm of air with oxygen transfer efficiency of 3-4% per/meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from plat form at the top. ( fine bubble epdm membrane diffusers) Make: SSI/Quasys/Rehau/OTT

1

-

-

... More
Providing and fixing all piping (as described below) and isolation control valves for making the system complete. CPVC : Submerged air piping, Air Piping PVC :Pumped effluent & tank overflow pipe line MSEP : Interconnecting pipe line after delivery header of pump/ filter

1

-

-

... More
Supplying installing, testing and commissioning of MBR Membrane Module in MBR Tank of Sutaible Capacity for 16 KL in SS 304 Skid MOC : PVDF Type : Outside In Micron : 0.2 Micron Effective Surafce Area : 20m2/Membrane Membrane Quantity -2 Nos. = 1 Set Make : Deerfos/GE/Toray/Mitsubishi

1

-

-

... More
Supplying, installing, testing & commissioning of Horizontal centrifugal water pumps,CI Body & Impeller along with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve. Mechanical seal, drain pipe with valve for the pump. The pump shall be suitable for 415±10% volts 3 phase AC supply MBR Permiate pump Capacity : 1 m3/hr Head :12-20M No. of Pumps (1W+1S) Make: Wilo/Ebara/Grundfos /CRI

2

-

-

... More
Supplying, installing, testing and commissioning of Basket Type Centrifuge Sludge Drying System MOC SS 304 Baskety MSEP Body along With Motor Size : 12" Make: Airtech/Harihar

1

-

-

... More
Supply, installation, Testing & commissioning of sludge feed pumps Monoblock Centrifugal pmplete with all fittings & accessories QTY : 2 No. 1 W Capacity : 1 m3/hr @ 10 M H MOC : CI Make Kirloskar/CG/M&P

1

-

-

... More
Supply, installation, testing & commissioning of UV System for Disinfaction of Treated Water Flow : 1 m3/hr MOC: SS 304 Make: Sukrut/Alfa

1

-

-

... More
Online Instrument pH Meter - 1 Nos. Make : Aster/Digital Flow Meter - 1No. Make : Adept/Aster

1

-

-

... More
STP ELECTRICAL PANEL WITH PLC & HMI Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Motor Control Centre Incoming 100 amps TPN MCCB with the following accessories: a. 0-500 volts 96 x 96 mm square electronic voltmeter with selector switch shall be protected by 2 amps TP MCB. 1 Set b. 0-200 amps 96 x 96 mm square electronic ammeter with selector switch and 125./5 amps 10 VA CL:1 CTs. 1 Set c. Phase indicating lamps shall be protected by 2 amp SP MCB 3 Sets Bus Bar 200 amps TPN (15 KA) copper bus bar with heat shrinkable insulation sleeves. a. Required Nos of required capacity TPN MCB for direct on line starter/star delta starters and out going feeders to all the pumps/blowers etc. (including standbies). Each compartment shall contain auto / manual selector switch and indicating lamp with MCB’s for ‘ON/OFF/TRIP’ status of motor b. Motor starters shall be provided with Automatic level controller c. DOL starters shall be used for mototrs below 10HP and Star-Delta Starters for other motors . d. Provision shall be made for providing potential free contacts to all pumps starters e. All MPCB, Contactor,Overload Relay Shall be L&T f. PLC& HMI : Mitsubishi/Allen Bradley/ Siemens

1

-

-

... More
Supplying, installing, testing & commissioning of Cables , Conector, Cable Trays, to make Electrical Installation Complete. a) Cable Type - 3& 4 Core Alu/Copper Capacity - As per the control panel and machines to connected. Size of cable - 3 & 4 core x up to 4sqmm or as required. b) Cable Tray Qty - As required Type - Slotted GI Size - 2" x 4" x 6" or as required. c) Cable Tray Support Quantity - As per site requirment of approved quality. TOTAL SUMMARY FOR ELECTRICALS

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.