Public Works Building And NH Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 3,37,267Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWBNH_40416_1Tender No
SE(N)/04/2024-25/Pt/195Tender Authority
Public Works Building And NH Department ViewPurchaser Address
-Website
http://PublicWorksBuildingAndNationalHighwayDepartment
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
38665.42
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
111.28
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
326.1
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc for mass concrete
9.01
-
-
Centering and shuttering including strutting, propping etc and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
641.76
-
-
Centering and shuttering including strutting, propping etc. and removal of form for Walls any thickness including attached pilasters, butteresses, plinth and string courses etc
114.24
-
-
Centering and shuttering including strutting, propping etc and removal of form for Stairs, excluding landings except spiral-staircases
36.9
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 1 cement : 1.5 coarse sand zone-III derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources
57.75
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 1 cement : 1.5 coarse sand zone-III derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources
172.26
-
-
Centering and shuttering including strutting, propping etc and removal of form for Suspended floors, roofs, landings, balconies and access platform
855.43
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 1 cement : 1.5 coarse sand zone-III derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources
0.86
-
-
Brick work with common burnt clay F.P.S. non modular bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 1 cement : 4 coarse sand
6.15
-
-
Half brick masonry with common burnt clay F.P.S. non modular bricks of class Designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 1 cement :4 coarse sand
444.73
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 1 Cement : 3 coarse sand zone-III derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources
0.67
-
-
Providing and laying vitrified floor tiles in different sizes thickness to be specified by the manufacturer with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 1 cement : 4 coarse sand, jointing with grey cement slurry @ 3.3 kg sqm including grouting the joints with white cement and matching pigments etc complete Size of Tile 600x600 mm
288.2
-
-
Providing and laying Vitrified tiles in floor in different sizes thickness to be specified by the manufacturer with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 1 cement: 4 coarse sand jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. v Size of Tile 600 x 600 mm
299.05
-
-
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 1 cement : 3 coarse sand, finished with a floating coat of neat cement. 18 mm thick
27.99
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 thickness to be specified by the manufacturer, of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 1 cement : 3 coarse sand and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
170.52
-
-
Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 1 cement : 4 coarse sand : Light shade pigment using white cement
60.21
-
-
Kota stone slab flooring over 20 mm average thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 1 cement : 4 coarse sand : 25 mm thick
35.85
-
-
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm average thick cement mortar 1:3 1 cement: 3 coarse sand and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete
26.88
-
-
Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc
333.5
-
-
12 mm cement plaster of mix : 1:4 1 cement: 4 fine sand
377.42
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 1 cement: 4 fine sand
924.24
-
-
20 mm cement plaster of mix : 1:4 1 cement: 4 fine sand
16.4
-
-
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc
1247.94
-
-
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
3.78
-
-
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
3.78
-
-
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm weight not less than 10kg/sqm
69.33
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
1032.24
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
1293.6
-
-
Finishing walls with water proofing cement paint of required shade : New work Two or more coats applied @ 3.84 kg/10 sqm
377.38
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work two or more coats over and including water thinnable priming coat with cement primer
912.06
-
-
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile E Fixing with adjustable lugs with split end tail to each jamb
122.3
-
-
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVCfoam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size,complete as per manufacturer’s specification and direction of Engineer- in-Charge.
20
-
-
Providing and fixing to existing door frames.
30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam PUF Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856, complete as per direction of Engineer-in-charge
6.72
-
-
Providing and fixing ISI marked flush door shutters conforming to IS 2202 (Part I) decorative type, core of block board construction with:frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
51.87
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . Cost of aluminium snap beading shall be paid in basic item: With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm
70.53
-
-
Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work hard and soft wood
136.14
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
136.14
-
-
Steel work in built up tubular round, square or rectangular hollow tubes etc trusses etc, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
7137.9
-
-
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections galvanized @ 120 grams sqm, both side inclusive consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick minimum sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick minimum sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick minimum sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cuttingmaking, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC Noise Reduction Coefficient of 0.85, with 50 mm thick rockwool of 48 kg /cum backing.
330.25
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transport ation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
443.39
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +0.05 % total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete
46.85
-
-
Barge Board
85.62
-
-
Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet Anglo Indian W.C pan with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend
5
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
6
-
-
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mmsizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern
3
-
-
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
6
-
-
Providing and fixing mirror of superior glass of approved quality and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia
6
-
-
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
6
-
-
Providing and fixing 3 layer PP-R Poly propylene Random copolymer pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. PN - 10 Pipe, 110 mm OD SDR-11
51
-
-
Providing and fixing 3 layer PP-R Poly propylene Random copolymer pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. PN - 10 Pipe, 75 mm OD SDR-11
41
-
-
Providing and fixing 3 layer PP-R Poly propylene Random copolymer pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. PN - 10 Pipe, 50 mm OD SDR-11
25
-
-
Providing and fixing 3 layer PP-R Poly propylene Random copolymer pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. PN - 10 Pipe, 40 mm OD SDR-11
18
-
-
Providing and fixing 3 layer PP-R Poly propylene Random copolymer pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. PN - 10 Pipe32mm OD SDR-11
20
-
-
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge PN - 10 Pipe, 25 mm OD SDR-11
15
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door 75x75x75 mm
6
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door 110 x 110 x 110 mm
6
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee without dor 75x75x75 mm
6
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door 110 x 110 x 110 mm
8
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5 75 mm bend
6
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm bend
6
-
-
Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
45
-
-
Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20 mm nominal dia Pipes
25
-
-
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 1 cement : 4 coarse sand for water meter complete with C.I. double flap surface box 400x200x200 mm inside with locking arrangement and RCC top slab 1:2:4 mix 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size , i/c necessary excavation, foundation concrete 1:5:10 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size and inside plastering with cement mortar 1:3 1 cement : 3 coarse sand 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.non modular bricks of
12
-
-
Providing and fixing gun metal gate valve with C.I. wheel of approved quality screwed end : 32 mm nominal bore
2
-
-
Providing and fixing gun metal gate valve with C.I. wheel of approved quality screwed end : 50 mm nominal bore
2
-
-
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
6
-
-
Providing and fixing C.P. brass stop cock concealed of standard design and of approved make conforming to IS:8931 15 mm nominal bore
6
-
-
Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia
7
-
-
Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms
7
-
-
Boring with 100 mm diameter casing pipe for hand pump tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump tube well is lowered and tested : Beyond 12 m and up to 18 m depth
42
-
-
Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality in all soils expwct ordinary hard rocks requirding balsting
39
-
-
Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well.
5
-
-
Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories with brass stariner or approved quality in all soil except ordinary hard roack requiring blastering includig removing the casing tested
1
-
-
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete New work 15 mm nominal bore
1
-
-
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete New work 32 mm nominal bore
1
-
-
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete New work 40 mm nominal bore
1
-
-
Providing and placing on terrace at all floor levels polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
2000
-
-
Wiring for light point, fan point, exhaust fan point, call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Group C
95
-
-
Supplying and fixing piano type socket on the existing switch box cover including connection etc as required. 3 pin 5 6 A Socket outlet
24
-
-
Supplying and fixing piano type socket on the existing switch box cover including connection etc as required. 6 pin 15 16 A Socket outlet
7
-
-
Wiring of circuit submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
390
-
-
Wiring of circuit submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
200
-
-
Wiring of circuit submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
110
-
-
Wiring of circuit submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface recessed medium class PVC conduit as required 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
100
-
-
Wiring of circuit submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
35
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. But without MCB,RCCB, Isolator 8 way , Double door
3
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB, RCCB, Isolator 12 way , Double door
2
-
-
Supplying and fixing of following ways surface recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs but without MCBs and incomer as required Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required 12 way 4 + 36, Double door
1
-
-
Providing and fixing following capacity TP&N disconnector fuseswitch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel making connections, etc. as required. 63 A TPN
2
-
-
Providing and fixing following capacity TP&N disconnector fuseswitch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel making connections, etc. as required. 160A TPN
1
-
-
Supplying and fixing 5 A to 32 A rating, 240, 415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
20
-
-
Supplying and fixing following rating, double pole, single phase and neutral, 240 V, residual current circuit breaker RCCB, having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 A
4
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current BLDC Motor, class of insulation resistance more than 2 mega ohm, suitable for230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
30
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. modular plate & switch box excluding modular plate as
31
-
-
Supplying and fixing call bell, buzzer suitable for single phase, 230 V, complete as required
1
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal coke and salt as required. including accessories, and providing masonry enclosure with with charcoal coke and salt as required.
2
-
-
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. but without charcoal coke and salt as required
1
-
-
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metrebelow ground as strip earth electrode, including connection terminating with nut, bolt, spring, washer etc. as required. Jointing shall be done by overlapping and with 2 sets of brassnut bolt and spring washer spaced at 50mm
8
-
-
Providing and laying earth connection fromm earth electrode with 6 SWG dia GI wire ini 15 mm dia GI pipe from earth electrode inlcuding connection with GI thimble exavation and re-filling as required
14
-
-
supplying, fitting & fixing of LED tube light aluminium Extruded smart Bright Batten light fitting 4 ft Model No. BN021C LED22S PSU CW GR Philips make as required and as directed by the department
30
-
-
Supplying fitting & fixing of LED Bulb 7W,9W, 12W non- dimmable in the existing batten angle holder as required and as directed by the department Philips or eqvt make
15
-
-
Supplying fitting and fixing Bajaj caapcitor type propeller type AC ventilator fan-exhaust 200 mm sweep size as required and as directed by the Department
6
-
-
Supplying including installation testing and commissioning of Hi wall non ductable type of 2.00 Ton capacity having proper cooling capacity singl phase 3 star MODEL splite type inverter Air Conditioner Machine complete with corded Remote, copper pipe connection between indoor & outdoor unit, electrical connection etc. as approved spiecied and directed by the Deptt Daikin or equivalannt Make 2.00 Ton Capacity
2
-
-
Supplying with fitting and fixing of 4 KVA Voltage stabilizer including making necessary connection as approved, specified and directed by the deptt Slyline make Model No. SKL-AVR-4KV
2
-
-
Supplying with fitting and fixing of Single Phase Modular Motor Starter switch including making necessary connection as per direction of department Legrand Make Model no. 6730 31
2
-
-
Supply of following size PVC, XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip , extruded PVC Type ST2 sheathed, 650,1100V grade as per IS 7908 Part 1 1988 armoured U.G. cable U.G. cable laid in ground, partially in air as required for termination up as specified and directed by the deptt RR Kabel, Havells, Polycab make or equivalent 70 sq. mm armoured cable 3.5 core KEIor equivalent make
69
-
-
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor type double door, floor mounting compartmentalize panel board of size 800 mm X1200 mm X 400 mm made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom and C.R. sheet roofing on the top. The panel board is to be erected in 1 : 3 : 6 PCC foundation including excavation of trench and brick soling etc. complete neatly Wiring done with provision for 1. 1 no 250 A 4pole 415V MCCB 2. 2 nos. 250 A SPREADER TERMINAL, 3. 1 no160 A 4P MCCB 4. 2 nos. 160 A SPREADER TERMINAL 5. 3 nos 32 A 4P MCB etc
1
-
-
Supplying installation testing and Commissioning of Passenger Elevator KONE/TKE make for 3 stop 544 K8 persons) having contractj speed of 0.65 Metre /sec. (approx) MPS seerving different floor in the exsiting lift shaft as per deatiled specification enclosed and as under Location of the lift- 1. Tyupe & Caapcity _Passenger -08 Persons 544 KG 2. Speed -0.65 Mtr / Sec- approx 3. Type of drive variable voltage variable Frequensy Drive with Mocriprocessor based simplec Full collectieve control
4. Location of Machine room -Top
5. Availabe Travel 7.2 Mtre (Maximum
6. Serving -Ground Floor to 2nd floor (0,1,2) 3stops 3 levels 3 Openings
7. Well size 1850 mm Widex 1850 mm Deep over t he finished surface
8. Power supply 415 volts 3 phase 50 cyucles alternating current
9. Auxiliary Required - single phade 220 V 50 Cycle alternating current
10. Cab size Clear inside approax -1300 mm wide x 1100 mm Deep
11. Pit Depth 1600 mm 12. Head room 4800 mm
13. Car Enclosure stainless steel Car Hirline finish
14. Flooring PVC Flooring
15. Elecctric light Fluorescent Light Fitting
1
-
-
Payment to be made to the APDCL authority for Load Security as per APDCL norms
12
-
-
Payment to be Metre Security ( sigle phase)paid to the APDCL authority
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%