Public Health Engineering Department Tender
... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Public Health Engineering Department - PHED Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date12 Mar 2025
Closing Date3 Apr 2025
Tender Amount₹ 1,82,85,000
Costs
EMD
₹ 3,65,700Document Cost
₹ 3,700Tender Fee
Refer Documents
Summary
Additional Water Supply Pipeline To Kamarkuchi Village From The Distribution Network Of Chandrapur And Dimoria Block Kamrup (m) For The Year 2024-25
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_PHED_43405_1Tender No
SEPH/GC/TB-152/Vol-XII/2024-25Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://https://phe.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
9.12.1 (APHE) Labour charge for carrying and laying in position D.I. pipes & specials (class K-7) in line level complete as directed.
(b) 100 mm dia
2300
-
-
... More
9.12.6 (APHE) Providing joints to DI S&S pipes including cutting the pipes where necessary & supplying all jointing materials where necessary with testing of the joints all complete as directed.
1050
-
-
... More
9.6.1 Labour charge for carrying, placing in position fitting-fixing C.I. sluice valve,(with wheel & cap) C.I. reflux valve complete with supplying bolts and nuts and 3mm thick rubber insertion sheet etc. all complete as directed.(one valve and two flange joints
d) 150mm dia
1
-
-
... More
9.6.1 (APHE) Labour charge for carrying, placing in position fitting-fixing C.I. sluice valve,(with wheel & cap) C.I. reflux valve complete with supplying bolts and nuts and 3mm thick rubber insertion sheet etc. all complete as directed.(one valve and two flange joints
b) 100mm dia
1
-
-
... More
18.35 (DSR) Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
2
-
-
... More
18.41 (DSR) Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :
18.41.10 -150 mm diameter pipe
1360
-
-
... More
18.41 (DSR) Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :
18.41.9 -100 mm diameter pipe
1590
-
-
... More
18.41 (DSR) Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :
18.41.9-100 mm diameter pipe
2300
-
-
... More
4.1 (DSR) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
4.1.3A 1:2:4 (1 cement : 2 coarse sand (zone-III) including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size Recycled Concrete Aggregate (RCA) upto 25%)
94.5
-
-
... More
5.7 (APHE) D.I. Pipe (Class K-9)
a) 150mm dia
1360
-
-
... More
5.7 (APHE) D.I. Pipe (Class K-9)
b) 125mm dia
1590
-
-
... More
5.7 (APHE) D.I. Pipe (Class K-9)
c) 100mm dia
2300
-
-
... More
APHE 6.4.2 Ductile Iron Socket/ Spigot Pipes Class-K9 As per IS:8329/2000
a) 150mm dia
48
-
-
... More
APHE 6.4.2 Ductile Iron Socket/ Spigot Pipes Class-K9 As per IS:8329/2000
c) 100mm dia
70
-
-
... More
APHE 6.4.3 Ductile Iron Sockets as per IS : 9523/2000
(a) 100 mm -200 mm
1387.5
-
-
... More
APHE 6.4.4 Ductile Iron Flange as per IS : 9523/2000
(a) 100 mm -200 mm
1440
-
-
... More
APHE 6.4.5 DI DOUBLE SOCKET BRANCH FLANGE TEE
(a) Up to 500 x 500 mm
1152
-
-
... More
APHE 6.4.6 DI ALL SOCKET TEE
(a) Up to 500 mm
720
-
-
... More
APHE 6.4.7 DI DOUBLE SOCKET TAPER (REDUCER)
(a) Up to 500x450 mm
780
-
-
... More
APHE 6.4.8 DI FLANGED SPIGOT (Adoptor)
(a) Up to 500 mm
1050
-
-
... More
APHE 6.4.9 DI DOUBLE SOCKET DUCK FOOT BEND 90
(a) Up to 300 mm
1040
-
-
... More
6.4.12 -DI ALL FLANGE CROSS
(a) Up to 300x300 mm
1674
-
-
... More
6.4.13-DI DOUBLE FLANGE REDUCER
a) Up to 500x450 mm
700
-
-
... More
6.4.14-DI BLANK FLANGE
(a) Up to 500 mm
544
-
-
... More
6.4.15-DI MECHANICAL JOINT
(a) Up to 300 mm
1800
-
-
... More
6.4.16 DI DOUBLE SOCKET BEND 900
(a) Up to 500 mm
736
-
-
... More
6.4.16 DI DOUBLE SOCKET BEND 450
(a) Up to 500 mm
576
-
-
... More
6.4.16 DI DOUBLE SOCKET BEND 22.50
(a) Up to 500 mm
465
-
-
... More
6.4.16 DI DOUBLE SOCKET BEND 11.250
(a) Up to 500 mm
392
-
-
... More
6.4.17-DI DOUBLE FLANGE BEND
(a) Up to 500 mm
882
-
-
... More
6.4.18-RUBBER GASKET FOR DI PIPE CONFORMING TO BIS :5832/85 (d) 150mm dia
28
-
-
... More
6.4.18-RUBBER GASKET FOR DI PIPE CONFORMING TO BIS :5832/85 (c) 125mm dia
22
-
-
... More
6.4.18-RUBBER GASKET FOR DI PIPE CONFORMING TO BIS :5832/85 (b) 100 mm dia
32
-
-
... More
2.8-Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m 2.8.1-All kinds of soil.
4.36
-
-
... More
16.12-Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :
16.12.1-With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
13.72
-
-
... More
4.20A-Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within the permissible utilization, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.
4.20A.1 All works upto plinth level
0.64
-
-
... More
5.22-Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
5.22.4-Hot rolled deformed bars
12 mm dia TS Rod
221.38
-
-
... More
5.22-Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
5.22.1 Mild steel and Medium Tensile steel bars
69.82
-
-
... More
5.9-Centering and shuttering including strutting, propping etc. and removal of form for
5.9.1-Foundations, footings, bases of columns, etc. for mass concrete
8.8
-
-
... More
5.9-Centering and shuttering including strutting, propping etc. and removal of form for
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
11.04
-
-
... More
5.9-Centering and shuttering including strutting, propping etc. and removal of form for
5.9.5-Lintels, beams, plinth beams, girders, bressumers and cantilevers
10.58
-
-
... More
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
0.58
-
-
... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
1.37
-
-
... More
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
3.14
-
-
... More
6.8 Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five
level.
13.72
-
-
... More
10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
314.92
-
-
... More
12.1Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
7.5
-
-
... More
12.4 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m²
14.4
-
-
... More
12.13 Providing and fixing fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing accessories in all colours with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers or with self drilling fastener and EPDM washer etc. complete:
12.13.5 Barge boards
10
-
-
... More
2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
2.34
-
-
... More
21.1 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
5.2
-
-
... More
11.41 A Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
11.41A 2.1 Glazed vitrified floor tiles polished finish of size
7.19
-
-
... More
11.38 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
6.4
-
-
... More
9.3 Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
9.3.1 Sal wood
0.11
-
-
... More
26.25 Providing and fixing 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991,in true horizontal level on the existing frame work consisting of T-sections and Lsections suitably fixed according to tile size as per direction of Engineer-in-charge.
4
-
-
... More
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
9.1.2 Sal wood
0.09
-
-
... More
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required
size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:-
Butt hinges and necessary screws shall be paid separately)
9.5.1 Second class teak wood
9.5.1.1 35 mm thick shutters
1.48
-
-
... More
9.7 Providing and fixing panelling or panelling and glazing in panelled or
panelled and glazed shutters for doors, windows and clerestory windows
(Area of opening for panel inserts excluding portion inside grooves or
rebates to be measured). Panelling for panelled or panelled and glazed
shutters 25 mm to 40 mm thick :
9.7.1 Second class teak wood
0.79
-
-
... More
13.2 -15 mm cement plaster on the rough side of single or half brick wall of mix :
13.2.1 1:4 (1 cement: 4 fine sand)
13.72
-
-
... More
13.31 Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand):
13.31.1 Flush / Ruled/ Struck or weathered pointing
17.26
-
-
... More
9.48Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
9.48.2-Fixed to openings /wooden frames with rawl plugs screws etc.
12.15
-
-
... More
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :
13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
17.26
-
-
... More
13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
13.43.1 Water thinnable cement primer
13.72
-
-
... More
13.50 Applying priming coat:
13.50.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
9.14
-
-
... More
9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
9.96.1 300x16 mm
2
-
-
... More
9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
9.97.4 150x10 mm
8
-
-
... More
9.100Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
9.100.1 125 mm (Door)
4
-
-
... More
1.1-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
1.1.1 Group A
2
-
-
... More
1.1-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
1.1.2 Group B
1
-
-
... More
1.1-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.1.3 Group C
1
-
-
... More
1.2-Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
1
-
-
... More
1.3-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.3.1-Group A
2
-
-
... More
1.3-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.3.2-Group B
1
-
-
... More
1.54-Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.54.1-Group A
3
-
-
... More
1.54-Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.54.2-Group B
2
-
-
... More
1.54-Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.54.3-Group C
2
-
-
... More
7.1-Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
7.1.1-Upto 35 sq. mm
10
-
-
... More
7.1-Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
7.1.2-Above 35 sq. mm and upto 95 sq. mm
6
-
-
... More
1.6-Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
10
-
-
... More
1.35-Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
1
-
-
... More
1.41-Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
2
-
-
... More
19.1-Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
1
-
-
... More
5.3-Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
1
-
-
... More
15.4-Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
15.4.3-3 output (1output per phase) and suitable for three phase supply
1
-
-
... More
N.S.-Provisional estimate for power connection from ASEB pole to Box system Panel Board including providing necessary accessories such as cable, starter, D.B. Box, cable etc. all complete as directed by the ASEB personal for Water Supply Arrangement at Kamarkuchi Village under Sonapur Operating complex
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%