Public Health Engineering Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,35,440Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PHED_38405_1Bid Award Id
ViewTender No
SE (PHE) JOR/TB-190/2024-25/ 226 dated 08/08/2024Tender Authority
Public Health Engineering Department ViewPurchaser Address
-Website
http://assamtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BID DOCUMENT FOR THE WORKS OF NEW SUB-DIVISIONAL OFFICE BUILDING IN TITABOR (PHE) SUB-DIVISION UNDER THE PROGRAMME SOPD-G (NIT NO. 01 OF 2024-25(RE-TENDER))
SHORT E-PROCUREMENT NOTICE (RE-TENDER) AGAINST NIT NO. 01 OF 2024-25
BOQ FOR THE WORKS OF NEW SUB-DIVISIONAL OFFICE BUILDING IN TITABOR (PHE) SUB-DIVISION UNDER THE PROGRAMME SOPD-G (NIT NO. 01 OF 2024-25 (RE-TENDER))
BOQ Items
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
94.81
-
-
... More
CAST IN SITU
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
47.08
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
79.2
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
Lintels, beams, plinth beams, girders, bressumers and cantilevers Tie
91.18
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
Columns, Pillars, Piers, Abutments, Posts and Struts
121.44
-
-
... More
PLINTH FOR THE NEW BUILDING OF TITABOR PHE SUB-DIVISION OFFICE
-
-
-
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
241.14
-
-
... More
EXPOSED BRICK WALL
Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).
From ground level upto plinth level
12.92
-
-
... More
CAST IN SITU
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
15.93
-
-
... More
EXTERIOR FINISHING
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
For GL
81.6
-
-
... More
CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3
81.6
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
Lintels, beams, plinth beams, girders, bressumers and cantilevers Plinth Beam:
176.54
-
-
... More
DETAIL ESTIMATE OF FLOORING INCLUDING G+1 FOR THE NEW BUILDING OF TITABOR PHE SUB-DIVISION OFFICE
-
-
-
... More
TILE FLOORING: Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) :
Medium shade pigment using 50% white cement and 50% ordinary cement
205.8
-
-
... More
DAMP-PROOF COURSE
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
205.8
-
-
... More
WALL INCLUDING G+1 FOR THE NEW BUILDING OF TITABOR PHE SUB-DIVISION OFFICE
-
-
-
... More
BRICK WALL
Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).
Above plinth level upto floor V level(GL)
49.78
-
-
... More
EXTERIOR FINISHING Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
229.75
-
-
... More
INTERIOR FINISHING Colour washing such as green, blue or buff to give an even shade :New work (two or more coats) with a base coat of whiting
812
-
-
... More
CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand)(GL)
665.63
-
-
... More
RCC WORK BEAM, COLUM, SLAB, LINTEL WITH SUN SHADE INCLUDING G+1 FOR THE NEW BUILDING OF TITABOR PHE SUB-DIVISION OFFICE
-
-
-
... More
CAST IN SITU(Column)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above linth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
19.11
-
-
... More
CAST IN SITU(Lintel)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above linth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1.14
-
-
... More
CAST IN SITU(Sun Shade)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above linth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
3.65
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
Lintels, beams, plinth beams, girders, bressumers and cantilevers
24.32
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
Columns, Pillars, Piers, Abutments, Posts and Struts
195.36
-
-
... More
REINFORCEMENT IN FOOTING, BEAM, COLUM, SLAB, STAIRS, LINTEL WITH SUN SHADE
-
-
-
... More
Steel Reinforvement (Footing): Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
1597.73
-
-
... More
Steel Reinforvement (Column):Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
2245.58
-
-
... More
Steel Reinforvement (Tie Beam):Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
1644.43
-
-
... More
Steel Reinforvement (Column):Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
3343.56
-
-
... More
STEEL REINFORCEMENT (Lintel 4nos.10mm dia, Strriups 8mm@150mm c/c): Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
287.9
-
-
... More
STEEL REINFORCEMENT (Sun Shade 10mm dia @ 120 mm c/c short side 8mm @ 180mm c/c: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
554.71
-
-
... More
CEILING INCLUDING G+1 FOR THE NEW BUILDING OF TITABOR PHE SUB-DIVISION OFFICE
-
-
-
... More
CEILING
Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) :
Flame retardant face insulating board 12 mm thick
224
-
-
... More
ROOFING AND DRAINAGE INCLUDING G+1 FOR THE NEW BUILDING OF TITABOR PHE SUB- DIVISION OFFICE
-
-
-
... More
SHEET ROOFING
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
0.63 mm thick with zinc coating not less than 275 gm/ m²
282.24
-
-
... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
662.66
-
-
... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
250 mm dia. R.C.C. pipe
76.5
-
-
... More
DOOR, WINDOW & VENTILATOR FOR THE NEW BUILDING OF TITABOR PHE SUB-DIVISION OFFICE
-
-
-
... More
door shutter 150 x 250 cm
(shutter only). Area = 3.75 sq. m.
10
-
-
... More
door shutter 120 x 250 cm
(shutter only). Area = 3 sq. m.
5
-
-
... More
Window shutter 150 x 150 cm
(shutter only). Area = 2.25 sq. m.
12
-
-
... More
Ventilator shutter 75 x 75 cm
(shutter only). Area = 0.563 sq. m.
12
-
-
... More
SOUND INSULATION AND ALUMINIUM PANEL FOR THE NEW BUILDING OF TITABOR PHE SUB-DIVISION OFFICE
-
-
-
... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
71.52
-
-
... More
INTERNAL ELECTRIFICATION OF TITABOR PHE SUB-DIVISION OFFICE WITH A NEW BUILDING
-
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
-
-
-
... More
1. Group A
7
-
-
... More
2. Group B
5
-
-
... More
3. Group C
5
-
-
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator): 8 way , Double door
4
-
-
... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick
including accessories, and providing masonry enclosure with cover
1
-
-
... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as
required..
2
-
-
... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.: Qty = 20no.
10
-
-
... More
Supply, Installation, Testing and Commissioning of LED RGB/ RGBW flood lighting luminaire for façade lighting with Die-cast aluminum housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/ Ethernet based control. The be an angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 VAC, 50 Hz with power factor
0.9. Fixture shall be suitable to operate at an ambient temperature range of-10 °C to +50 °C and shall be IP 65 and IK 06 rated. Life time shall be at least L70: 50000 burning hours at 50 °C. Luminaire shall be conforming to BIS (IS10322) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.:30 W
4
-
-
... More
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/ VRF Cassette Type In door ceiling mounted unit equipped with synthetic washable media pre- filter, fan section with low noise fan/ dynamically balanced blower, multi speed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of in door unit will be at air inlet conditions of 27 Degree CD Band 19 Degree CWB temperature : 2 TR
4
-
-
... More
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
450 lpm at 35 m Head
1
-
-
... More
Skilled Labourers and Technician
5
-
-
... More
PLUMBING WORKS OF TITABOR PHE SUB-DIVISION OFFICE WITH A NEW BUILDING
-
-
-
... More
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :2. 20 mm dia nominal bore
35
-
-
... More
BRASS FITTINGS: Providing and fixing brass bib cock of approved quality :15 mm nominal bore
4
-
-
... More
Providing and fixing C.P. brass shower rose with 15 or 20
mm inlet :100 mm diameter
4
-
-
... More
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :
Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern
3
-
-
... More
Providing and fixing brass stop cock of approved quality :2. 20 mm nominal bore
8
-
-
... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
3
-
-
... More
Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:
White glazed fire clay kitchen sink of size 600x450x 250 mm
1
-
-
... More
External work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
80 mm nominal dia Pipes
20
-
-
... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid
3
-
-
... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1
-
-
... More
Boundary Wall
-
-
-
... More
Reinforcement in Tie Beam: Steel reinforcement for R.C.C. work including straightening, cutting, bending,
placing in position and binding all complete upto plinth level.:5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
188.8
-
-
... More
Reinforcement in Lintel Beam: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.: 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
188.8
-
-
... More
Reinforcement in Column: Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.: 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
377.6
-
-
... More
Brick Work: Brick work with common burnt clay selected F.P.S. (non modular) bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand)150mm thick brick wall; 6.26.2 Above plinth level upto floor V level
16.94
-
-
... More
Shuttering Work on Tie Beam: Centering and shuttering including strutting, propping etc. and removal of form; 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
57.38
-
-
... More
Shuttering Work on Lintel Beam: Centering and shuttering including strutting, propping etc. and removal of form; 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
38.25
-
-
... More
Shuttering Work on Column: Centering and shuttering including strutting, propping etc. and removal of form; 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
102
-
-
... More
CEMENT CONCRETE WORKS ON TIE BEAM: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All
work up to plinth level :5.1.2A 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) incuding manu factured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate (RCA)
upto 20%.
4.78
-
-
... More
CEMENT CONCRETE WORKS ON LINTEL BEAM: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All
work up to plinth level :5.1.2A 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) incuding manu factured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate (RCA)
upto 20%.
4.78
-
-
... More
CEMENT CONCRETE WORKS ON COLUMN: Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All
work up to plinth level : 5.1.2A 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) incuding manu factured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20 mm nominal size of Recycled Concrete Aggregate (RCA)
upto 20%.
5.46
-
-
... More
PAINTING WORKS(EXTERIOR FINISHING): Finishing walls with textured exterior paint of required shade :13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and
including priming coat of exterior primer applied @ 2.20kg/10 sqm
229.5
-
-
... More
EARTHWORK IN EXCAVATION: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge.: 2.7.1 Ordinary rock
4.08
-
-
... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
ENTRANCE GATE
250.98
-
-
... More
SITE DEVELOPMENT INCLUDING G+1 FOR THE NEW BUILDING OF TITABOR PHE SUB-DIVISION OFFICE
-
-
-
... More
Site Clearance: Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
400
-
-
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
249.6
-
-
... More
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse : 4 graded sand aggregate 20 mm nominal size), including finishing complete. Stone
8
-
-
... More
OFFICE FURNITURE
-
-
-
... More
Full Secretariet Table (Double Drawer)
Size 1690x900x760M
2
-
-
... More
Half Secretariet Table (Single Drawer)
Size 1230x620x760M
6
-
-
... More
Wooden Computer Table
4
-
-
... More
Executive Revolving Chair High Back
1
-
-
... More
Medium Back Revolving Chair
6
-
-
... More
Computer Revolving Chair
6
-
-
... More
Executive Visitors Chair
7
-
-
... More
Staff Visitors Chair
10
-
-
... More
Steel Almirah (Big) Size :1980x915x480 mm
3
-
-
... More
Steel Almirah (Small) Size :1270x760x430 mm
3
-
-
... More
Steel Book Reck
6
-
-
... More
Steel Slotted Angle Reck
4
-
-
... More
Plastic Chair with Handle
32
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements