Pradhan Mantri Gram Sadak Yojana Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 8,41,400Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_CEASM_62405_1Bid Award Id
ViewTender No
CE/PMGSY/33/2017-18/15/Lot-3Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Removing all types of Hume pipes and stacking within a lead of 1000 m including earthwork and dismantling of masonry works as per Technical specification Clause 202.
(B) Above 600 mm to 900 mm dia Hume Pipe
15
-
147
... More
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
(i) Private Land
16828.69
-
155
... More
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
(i) Private Land
2367.37
-
209
... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
(A) By Mix in Place Method
ii) For Grading II Material
2403.62
-
2338.44
... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.
3) Grading –III (A) By Manual Means.
840.23
-
3423.66
... More
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502.
(i) Low Porosity
11203.09
-
41
... More
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
11203.09
-
11
... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.2 OGPC (Cold mix)
11203.09
-
184.06
... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510
By Mechanical Means. Case - III : Type C. Bitumen (S-90).
11203.09
-
82.69
... More
Reinforced cement concrete M 15 grade kilometer stone / local stone of standard design as per IRC: 8 and fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703.
ii) Ordinary Kilometer Stone (Precast)
3
-
2058
... More
Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801
vi) 60cm x 60cm square
1
-
9007
... More
Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801
ii) 60cm equilateral triangle
34
-
3897
... More
Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801
iii) 60cm circular
13
-
5167
... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1701.1.
1
-
19714
... More
Providing and fixing of typical Citizens Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
23890
... More
Provision of Rumble stripes covered with premix carpet 15.2mm high and 250mm wide placed at 1m centre to centre at approved location to control speed, marked with white stripes of road marking paint a. Premix carpeting
144
-
184.06
... More
Provision of Rumble stripes covered with premix carpet 15.2mm high and 250mm wide placed at 1m centre to centre at approved location to control speed, marked with white stripes of road marking paint b. Painting
144
-
55
... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
140.23
-
71
... More
Providing concrete for Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204
A. With Crushed Stone
I. PCC Grade M10, Nominal mix 1:3:6
24.42
-
5284
... More
Providing concrete for Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204
A. With Crushed Stone
III. PCC Grade M20, Nominal mix 1:2:4
107.52
-
6007
... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.
II. In 1:3 cement mortar
24.89
-
3606
... More
Providing concrete for Plain/Reinforced cement concrete, in substructure complete as per drawing and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204
A. With Crushed Stone
III. PCC Grade M20, Nominal mix 1:2:4
74.96
-
6354
... More
Stone masonry work in cement mortar in substructure complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.
II. In 1:3 cement mortar
15.95
-
3512
... More
Providing Weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing force complete as per Clauses 614, 709, 1204.3.7
57.6
-
182
... More
Backfilling behind abutment, wing wall and return wall complete as per drawing and Technical Specification Clause 1204.3.8 (i) Granular materials
35.05
-
1010
... More
Providing and laying filter media with granular crushed aggregates as oer specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8
36.49
-
1452
... More
Providing and laying Reinforced cement concrete in superstructure complete as per drawing and technical specification Clauses 800, 1205.4, 1205.5
A. With Crushed Stone
IV. RCC M-25, up to height of 5m
19.98
-
7869
... More
Supplying, fitting and placing TMT bar reinforcement (Fe-500) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 & 1202
1.49
-
66360
... More
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specification clause 1301
2.01
-
1166
... More
Bedding for pipe
(i) Type A(Concrete cradle) Beddingwith M15 grade cement as per clause 1105 (i)
2.48
-
5286
... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
6.31
-
5284
... More
Stone masonry work in cement mortar in foundation of head walls complete as per drawing and technical specifications Clauses 1109
12.76
-
3413
... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
(B) 1000 mm dia
7.5
-
6235
... More
Plastering with cement mortar (1:3), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
21.82
-
126.6
... More
Reinforced cement concrete M- 15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and technical specification Clause 1704
184
-
505
... More
Labour for dismantling all members of the timber bridge (except piles) and stacking them at sutiable places as directed (all members will be under custody of the contractor till taken over by the department )
49.6
-
850
... More
Labour for taking out old piles of the bridge and stacking them at suitable place as directed.
49
-
1052
... More
Earth work in excavation for foundation of structures as per drawings and technical specification clause 305.1, including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal up to a lead of 50m, dressing of sides and bottom and back filling in trenches with excavated suitable material. I.Ordinary soil (i) up to 3m depth
432.22
-
113
... More
Providing and construction of temporary island to accommodate pile rig and other assessories including casting of pile cap, all complete. Iii)Assuming depth of water 3.0m to 4.0m
2
-
41153
... More
Providing and construction of one span service road to reach island location from one pier location to another pier location
24.8
-
2258
... More
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specification and removal of excavated earth with all lifts and lead upto 1000m.(Pile diameter-1000mm)
492.8
-
15399
... More
Pile load test on single vertical pile in accordance with IS:2911 (Part-IV) a) Initial and routine load test
210
-
330
... More
Providing and laying of PCC M15 levelling course 100mm thick below the pile cap as per drawing and technical specification of MORTH Section
25.74
-
5776
... More
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification of MORTH Section 1100 & 1500 including steel shuttering formwork. B.RCC Grade M25 (i)Using concrete mixer
232.56
-
8450
... More
Supplying , fitting and placing TMT bar reinforcement in foundation complete as per drawing and Technical Specifications clause 1000 & 1202.
48.49
-
72065
... More
Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications Clauses 802,804,805,806,807,1202 and 1204. A.With crushed stone IV) RCC Grade M25 i)for height upto 5m.
135.47
-
7094
... More
Supplying , fitting and placing TMT bar reinforcement in substructure complete as per drawing and Technical Specifications clause 1000 & 1202.
15.91
-
72169
... More
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83(pt.II) section IX complete including all accessories as per drawing and Technical Specification clause 1207.1.
131040
-
1.15
... More
Providing and laying Reinforced cement concrete in superstructure as per drawing and Technical Specifications Clauses 800, 1205.4 and 1205.5 A with crushed stone. ii. RCC Grade M-25 Grade
Case I Using concrete mixer (ii) For T-Beam and Slab (i) Height upto 5m.
225.62
-
7885
... More
Supplying, fitting and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications clauses 1002,1010 & 1202.
38.87
-
70685
... More
Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications clauses 800 and 1206.3. (A) With natural aggregate.
29.79
-
14137
... More
Construction of precast RCC railing of M30 Grade aggregate size not exceeding 12mm, true to line and grade, tolerance of vertical Railing post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000mm leaving adequate space between vertical post foe expansion complete as per approved drawing and technical specifications
119.32
-
2140
... More
Providing and laying a burried expansion joint, covered with 12mm thick, 200mm wide galvanised weldable structural steel plate as per IS:2062, placed symmetrical to centre line of the joint, resting freely over the top surface of the deck concrete, welding of 8mm dia. 100mm long galvanised nails spaced 300mm c/c along the center line of the plate, as per technical specification clauses 1207.2.3
25.35
-
1492
... More
Providing and fixing in position 20mm thick pre moulded joint for fixed ends of simply supported spans not exceeding 10 m to cater for the horizontal movement up to 20 mm, covered with sealant complete as per drawing & Technical Specification
25.35
-
312
... More
Drainage spouts complete as per drawings and technical specification clause.
14
-
8615
... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. A. With granular material
184.06
-
1126
... More
P.C.C. M15 ordinary grade (1:2.5:5) levelling course below approach slab complate as per drawing and Technical Specifications
6.98
-
5893
... More
Reinforced Cement Concrete approach slab including reinforcement and formwork complate as per drawing and Technical Specifications with other ISI marked TMT grade rebar
13.95
-
13261
... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302. I.Stone/Boulder
169.86
-
2234.84
... More
Providing and l;aying filter material underneath pitching in slopes complete as per drawing and technical specifications
84.93
-
1332
... More
Boulder apron laid in wire crates (Providing and laying boulder apron laid in wire crates made with 4mm dia GI wire conforming to IS:280 & IS 4826 in 100 mm x 100 mm mesh (Weaved diagonally) including 10% extra for laps and joints.
247.03
-
2978.84
Evaluation Notes How It Works ?
Potential Partner