Pradhan Mantri Gram Sadak Yojana Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 5,79,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_CEASM_62034_71Bid Award Id
ViewTender No
CE/PMGSY/33/2017-18/15/Lot-2Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 (Manual should be use where machines can not be deployed due to site condition)
4040.87
-
79
Construction of Subgrade and Earthen Shoulders
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
(i) Private Land
2050.51
-
209
Surface Drains in Soil
Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307.
Manual Means
890
-
42
Granular Sub-base with Well Graded Material (Table 400.1)
By Mix in Place Method
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
(ii) For Grading II Material
1538.44
-
2902.86
WBM Grading 2
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.
(B) By Mechanical Means
854.68
-
3679.51
WBM Grading 3
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.
(B) By Mechanical Means
854.68
-
3731.51
Prime Coat :
Low porosity
Providing and applying primer coat with bitumen emulsion (CSS-1) on prepared surface of granular base/WBM/WMM including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
11395.85
-
41
Tack Coat
Providing and applying tack coat with Bitumen emulsion (CRS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
11395.85
-
13
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508.
Case - I By Manual Means
(iv) Crumb Rubber Modified Bitumen
11395.85
-
181.64
Seal Coat
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510
By Manual Means
Case - I : Type A
(iv) Crumb Rubber Modified Bitumen
11395.85
-
83.88
Providing and fixing 'Logo' of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
19714
Providing and Fixing Title information Board of PMGSY Project (RCC)
Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing including painting and lettering and fixing in ground 600mm x 600mm x 750mm CC including painting two course and lettering.
1
-
13332.98
Providing and Fixing Title information Board of PMGSY Project (RCC)
Providing and fixing of typical PMGSY Maintenance information sign board as per MORD specifications and drawing including painting and lettering and fixing in ground 600mm x 600mm x 750mm CC including painting two course and lettering.
1
-
15072.14
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703
(ii) Ordinary Kilometer stone (precast)
3
-
2058
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703
(iii) 200m Stone (precast)
12
-
546
Traffic Signs
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI Pipe 50mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and Technical Specification Clause 1701
(vi) 60 cm x 60 cm square
4
-
5373
Construction of Job pillars as per Technical Specification Clause 1602.4
12
-
482
Dismantling of existing structure
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.
Manual Means
(B) Cement Concrete
2.88
-
291
Dismantling of existing structure
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.
Manual Means
(C) Reinforced cement concrete
2.22
-
716
Dismantling Stone Masonry as per Technical Specification Clause 202.
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
(B) Rubble Stone Masonry in Cement Mortar
10.4
-
159
Excavation for Structures
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
195.42
-
71
Plain cement Concrete M10 (1:3:6 Nominal mix) in leveling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
8.84
-
5299
Type B (First Class) Bedding
Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105
14.36
-
969
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding (B) 1000 mm dia
30
-
6235
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
46.04
-
5917
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
52.44
-
6596
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
12.1
-
968
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6 [Hand Mixing]
5.04
-
5284
Providing concrete for plain / reinforced concrete in foundations complete as per drawings and technical specifications Clauses 802, 803, 1202 & 1203
PCC Grade M 20
Nominial mix (1:2:4) (Hand mixed)
13.14
-
6007
Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, & 1203
IV) R.C.C.grade M 20
18.89
-
6297
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204
PCC Grade M 20
Nominial mix (1:2:4)
9.41
-
6369
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
4
-
182
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. R.C.C grade M 20 RCC Grade M 20
Nominal Mix 1 : 2 : 4
4.97
-
7025
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
4
-
413
Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
0.77
-
65489
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
1.27
-
65583
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
0.02
-
66360
Providing bituminous wearing coat comprising of 20 mm thick premix carpet with 5 mm thick seal coat Type B for culverts as per drawing and technical specifications Clauses 1206.2 and 500.
12.75
-
319.52
Excavation for Structures
Earth work in excavation for foundation of structures as per drawings & technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material as per MORTH clause No.304.
i. In Ordinary Soil
ii. 3.00m to 6.00m depth
283.91
-
113
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications nd removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm)
258.4
-
11694
Pile load test on single vertical pile in accordance with IS:2911(Part-IV)
(a) Initial and routine load test
150
-
330
Leveling Course for Pile Cap
8.1
-
5776
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification
B RCC Grade M25
(I) Using Concrete Mixer
113.52
-
7514
Supplying, fitting and placing TMT bar reinforcement in foundation complete as per drawings and technical specifications
24.65
-
72065
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification
For height upto 5 m R.C.C. grade M 25
60.71
-
7982
Supplying, fitting and placing TMT bar reinforcement in substructrue complete as per drawings and technical specifications
4.29
-
72169
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) Section IX and clause 2005 MoRTH specification complete including all accessories as per drawings and technical specification
73785.6
-
1.15
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
B. RCC M-25
a. Height upto 5.0m
61.2
-
9014
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications
10.37
-
70685
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications
9.63
-
14137
Construction ofprecast R.C.C. railing of M 30 grade aggregate size not exceeding 12mm, true to line and grade, tolerance of vertical railing RCC post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm, leveling adequate spacing between vertical poss for expansion, complete as per drawing and technical specifications
48.24
-
2193
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement up to 70mm, compete as per approved drawings and standard specificatios to be installed by the manufacture/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation.
16.9
-
13139
Drainage spouts complete as per drawing and technical specifications
8
-
8615
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification
A) Granular material
189.49
-
1126
PCC M15 ordinary grade (1:2.5:5) in levelling course below approach slab complete as per drawing and technical specifications clause 800 and 1211
5.07
-
5083
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211
A. With Crushed stone
15.75
-
10840
Providing & laying of boulder apron laid in wire crates with 14mm dia GI wire conforming to IS : 280 in 100 mm x 100mm mesh (woven diagonally) including 10% extra for laps 7 joints laid with stone boulder weighing not less than 25 Kg each as per drawing
136.7
-
1910
Providing and laying Pitching on slopes laid over prepared Filter media asper drawing and technical specifications clause 1302 I. Stone Boulder
74.64
-
1166
Providing and laying Filter material underneath Pitching in slopes complete asper drawing and technical specifications clause 1302
37.32
-
1332