Numaligarh Refinery Limited Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Numaligarh Refinery Limited - NRL Tender

Works
Energy, Oil and Gas
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Jul 2024
Closing Date23 Aug 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and install of Earth electrode using 100 mm dia, Medium duty, 5 meter long, minimum galvanization thickness shall be average 100 micron and minimum mass shall be 720 gm/sq.m. earth pipe with GI cover cap, earth strip with bolts, nut & washer, including preparation of concrete chamber as inspection chamber ,excavation of earth pit, supply and filling of salt/ coke/ charcoal layer, supply of civil material, back filling and covering with GI cover cap. 500 x 500 mm, 6mm THK, removable cast iron cover for earth pit. Typical STC E01Earth electrode using 100 mm dia, Medium duty, 5 meter long, earth pipe with GI cover cap, earth strip with bolts, nut & washer. 500 x 500 mm, 6mm THK, removable cast iron cover for earth pit.Typical STC E01 with 5m long electrode

143

-

-

... More
Supply and install of Earth electrode using 100 mm dia, Medium duty, 3 meter long, minimum galvanization thickness shall be average 100 micron and minimum mass shall be 720 gm/sq.m. earth pipe with GI cover cap, earth strip with bolts, nut & washer, excavation of earth pit, supply and filling of salt/ coke/ charcoal layer, supply of civil material, back filling and covering with GI cover cap. 500 x 500 mm, 6mm THK, removable cast iron cover for earth pit. Typical STC E01Earth electrode using 100 mm dia, Medium duty, 3 meter long, earth pipe with GI cover cap, earth strip with bolts, nut & washer without concrete chamber as inspection chamber.

40

-

-

... More
SUPPLY OF MANDATORY SPARE FOR EARTH ELECTRODE

-

-

-

... More
Supply of Earth electrode using 100 mm dia, Medium duty, 3 meter long, minimum galvanization thickness shall be average 100 micron and minimum mass shall be 720 gm/sq.m. earth pipe with GI cover cap, earth strip with bolts, nut & washer, 500 x 500 mm, 6mm THK removable cast iron cover for earth pit.

40

-

-

... More
Supply of Earth electrode using 100 mm dia, Medium duty, 5 meter long, minimum galvanization thickness shall be average 100 micron and minimum mass shall be 720 gm/sq.m. earth pipe with GI cover cap, earth strip with bolts, nut & washer, 500 x 500 mm, 6mm THK removable cast iron cover for earth pit.

20

-

-

... More
EARTHING SYSTEM CONDUCTORS: Earthing conductors to be supplied and suitably cut, bent, formed, layed and fixed, buried in ground or embedded in concrete, clamped to structure / equipment foundations, racks, walls, roofs, trenches etc. as required including excavation and filling of earth, chipping and remaking of concrete surface. The contractor shall supply the required materials to complete the earthing installation, the material such as welding of earthing conductor joints, GI clamps, GI fastners, Lugs at earth plate & at equipment end wherever required, supply & applying of bitumin paint & hessian tape on underground joints & cold zinc spray on aboveground joints and necessary hardware for connecting, etc.,

-

-

-

... More
75 X 12 MM Hot Dip Galvanised GI Flat

21788

-

-

... More
75 X 10 MM Hot Dip Galvanised GI Flat

1800

-

-

... More
65 X 10 MM Hot Dip Galvanised GI Flat

100

-

-

... More
50 X 6 MM Hot Dip Galvanised GI Flat

57537

-

-

... More
40 X 5 MM Hot Dip Galvanised GI Flat

687

-

-

... More
25 X 6 MM Hot Dip Galvanised GI Flat

1070

-

-

... More
16 mm Dia Hot Dip Galvanised GI Wire Rope

34016

-

-

... More
10 mm Dia Hot Dip GalvanisedGI Wire Rope

1355

-

-

... More
8 SWG Solid GI Hot Dip Galvanised Wire Rope

469

-

-

... More
1C X 25 sqmm FRLS, PVC insulated copper Green coloured outer sheath earthing cable

2200

-

-

... More
1C X 25 sqmm FRLS, PVC insulated copper Green + Blue stripe coloured outer sheath earthing cable

1500

-

-

... More
1C X 25 sqmm FRLS, PVC insulated copper Green+ Yellow stripe coloured outer sheath earthing cable

2200

-

-

... More
1C X 25 sqmm FRLS, PVC insulated copper Green+ Yellow+ Green coloured outer sheath earthing cable

250

-

-

... More
1C X 25 sqmm FRLS, PVC insulated coppe Green+ Red stripecoloured outer sheath earthing cable

2000

-

-

... More
SUPPLY OF MANDATORY SPARE FOR EARTHING SYSTEM CONDUCTORS

-

-

-

... More
75 X 12 MM Hot Dip Galvanised GI Flat

400

-

-

... More
75 X 10 MM Hot Dip Galvanised GI Flat

200

-

-

... More
65 X 10 MM Hot Dip Galvanised GI Flat

50

-

-

... More
50 X 6 MM Hot Dip Galvanised GI Flat

500

-

-

... More
40 X 5 MM Hot Dip Galvanised GI Flat

100

-

-

... More
25 X 6 MM Hot Dip Galvanised GI Flat

100

-

-

... More
16 mm Dia Hot Dip Galvanised GI Wire Rope

500

-

-

... More
10 mm Dia Hot Dip GalvanisedGI Wire Rope

500

-

-

... More
8 SWG Solid GI Hot Dip Galvanised Wire Rope

200

-

-

... More
1C X 25 sqmm FRLS, PVC insulated copper Green coloured outer sheath earthing cable

50

-

-

... More
1C X 25 sqmm FRLS, PVC insulated copper Green + Blue stripe coloured outer sheath earthing cable

50

-

-

... More
1C X 25 sqmm FRLS, PVC insulated copper Green+ Yellow stripe coloured outer sheath earthing cable

50

-

-

... More
1C X 25 sqmm FRLS, PVC insulated copper Green+ Yellow+ Green coloured outer sheath earthing cable

50

-

-

... More
1C X 25 sqmm FRLS, PVC insulated coppe Green+ Red stripecoloured outer sheath earthing cable

50

-

-

... More
EARTHING BAR / PLATE: Supply and Installation on wall / column and connection of GI earth plates as per installation std drawing, (supply of anchor bolts as required shall also be supplied by the Contractor)

-

-

-

... More
GI Earthing Plate 75(W) x 10(Thk.) x 400(L) mm including all fixing accessories. Typical of STC E02

803

-

-

... More
GI Earth Plate, 50(W) x 10(Thk.) x 100(L) mm, Typical to Detail -1 of STC E18

594

-

-

... More
Tinned copper Earth Plate 112.5(W) x 10(Thk.) x 750(L) with insulator and all fixing accessories.Typical as Annexure-1

259

-

-

... More
Tinned copper Earth Plate 75(W) x 10(Thk.) x 500(L) with insulator and all fixing accessories.Typical as Annexure-1

40

-

-

... More
SUPPLY OF MANDATORY SPARE FOR EARTHING BAR / PLATE

-

-

-

... More
GI Earthing Plate 75(W) x 10(Thk.) x 400(L) mm including all fixing accessories., Typical of STC E02

40

-

-

... More
GI Earth Plate, 50(W) x 10(Thk.) x 100(L) mm, Typical to Detail -1 of STC E18

40

-

-

... More
Tinned copper Earth Plate 112.5(W) x 10(Thk.) x 750(L) with insulator and all fixing accessories.Typical as Annexure-1

30

-

-

... More
Tinned copper Earth Plate 75(W) x 10(Thk.) x 500(L) with insulator and all fixing accessories.Typical as Annexure-1

10

-

-

... More
LIGHTNING PROTECTION SYSTEM MATERIAL: Supply and fixing of below lightning rod, together with supporting arrangement inclusive of hardware and associated work as per installation drawings. This lightning rod shall be connected with main lightning grid/pit including supply of fixing fastners/ material.

-

-

-

... More
1000mm Long,16mm Dia CU lightning arrestor rod with base plate with required SS accessories

300

-

-

... More
Supply of 25 X 6 MM Hot Dip Galvanised GI Flat and the GI Flat to be suitably cut, bent, formed, layed and fixed, buried in ground or embedded in concrete, clamped to steel structure ,concrete, walls,roofs,trenches etc. as required including excavation and filling of earth, chipping and remaking of concrete surface, including fixing of test links and lightning counters.

7939

-

-

... More
Fixing Clamp / Insulator with required accessories like bolts nut & washer, suitable for GI for 25 x 6 MM GI flat, fixing to the structure of the lightning protection system (for mesh and down conductors)

11878

-

-

... More
Supply of Lightning counter, Outdoor, wall mounted

40

-

-

... More
Supply GI Test link, Wall mounted, suitable for 25 x 6 mm GI flat

110

-

-

... More
SUPPLY OF MANDATORY SPARE FOR LIGHTNING PROTECTION SYSTEM MATERIAL

-

-

-

... More
1000mm Long,16mm Dia CU lightning arrestor rod with base plate with required SS accessories

30

-

-

... More
Supply of 25 X 6 MM Hot Dip Galvanised GI Flat

300

-

-

... More
ACCESSORIES (H.D.G)

-

-

-

... More
8mm Dia 40 Long Bolt, Nut & Plain and spring washers.

500

-

-

... More
10mm Dia 40 Long Bolt, Nut & Plain and spring washers.

100

-

-

... More
12mm Dia 50 Long Bolt, Nut & Plain and spring washers.

100

-

-

... More
CABLING SYSTEM- SUPPLY OF MATERIALS & TERMINATION

-

-

-

... More
SUPPLY OF HV TERMINATION KITS INCLUDING LUGS AND HV CABLE END TERMINATIONS: Supply of Heat shrinkable HV Cable termination kit and termination of XLPE insulated HV cables of following sizes of cables as per specification no. NR-0ZZZZ-EL-SPE-0023 , including cutting and stripping of cable insulation, fixing compression type lugs and crimping the lugs onto the conductor, executing termination using Heat Shrinkable Termination Kit , restoration of the insulation,including drilling of suitable holes in equipment for fixing purpose, connection of leads, clamping, including anti tracking compound, installation and supply of ferrules, single core cable fixing clamps, cable ties, cable Aluminium tags. clamping of cores and earthing of armour, including all labour and materials complete as per approved drawings, specification of this tender and direction of Engineer-in-charge. This will also include provision of additional supports if required, for proper dressing and support of cable. The contractor to also arrange suitable Stop Plugs for unused entry, if required. The cost for supply of suitable crimping type, heavy duty, long barrel type Alluminium / Copper lugs and bimetallic strip (if required) shall be included in termination, no separate payment shall be made for cable lugs & bimetallic strips. All supplied lugs shall be of heavy duty long barrel type. NOTE: Exact OD of cables will be shared during detail engineering. Selection of correct size of termination kit as per cable data provided during detail engineering is contractor's responsiblity. Any incorrect selection of termination kit shall be replaced by contractor at no cost and time implication to purchaser. XLPE insulated, Unearthed Power Cables, Stranded aluminium conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed, conductor and insulation screened for following size & location ( Indoor / Outdoor type)

-

-

-

... More
33/33 KV, 1C X 500 Sqmm (OD approx.: 62 +/- 2.0 mm)- INDOOR

36

-

-

... More
33/33 KV, 1C X 630 Sqmm (OD approx.: 65.5 +/- 2.0 mm)- INDOOR

60

-

-

... More
11/11kV , 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 53.5 +/- 2.0 mm)-INDOOR

132

-

-

... More
11/11kV ,3C X 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 81 +/- 2.0 mm)-INDOOR

4

-

-

... More
11/6.35kV, 3C 185 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 81 +/- 2.0 mm)-INDOOR

10

-

-

... More
11/11kV , 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 53.5 +/- 2.0 mm)--OUTDOOR

6

-

-

... More
11/11kV ,3C X 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 81 +/- 2.0 mm)-OUTDOOR

4

-

-

... More
6.6/6.6 KV, 1C X 400 Sqmm (OD approx.: 41.5 +/- 2.0 mm)- INDOOR

45

-

-

... More
6.6/6.6 KV, 1C X 500 Sqmm (OD approx.: 44.5 +/- 2.0 mm)- INDOOR

291

-

-

... More
6.6/6.6 KV, 1C X 630 Sqmm (OD approx.: 48 +/- 2.0 mm)- INDOOR

123

-

-

... More
6.6/6.6 KV, 3C X 240 Sqmm (OD approx.: 76 +/- 2.0 mm)- INDOOR

24

-

-

... More
6.6/6.6 KV, 3C X 300 Sqmm (OD approx.: 81 +/- 2.0 mm)- INDOOR

20

-

-

... More
6.6/6.6 KV, 1C X 400 Sqmm (OD approx.: 41.5 +/- 2.0 mm)- OUTDOOR

6

-

-

... More
6.6/6.6 KV, 1C X 500 Sqmm (OD approx.: 44.5 +/- 2.0 mm)- OUTDOOR

6

-

-

... More
6.6/6.6 KV, 1C X 630 Sqmm (OD approx.: 48 +/- 2.0 mm)- OUTDOOR

18

-

-

... More
6.6/6.6 KV, 3C X 240 Sqmm (OD approx.: 76 +/- 2.0 mm)- OUTDOOR

18

-

-

... More
6.6/6.6 KV, 3C X 300 Sqmm (OD approx.: 81 +/- 2.0 mm)- OUTDOOR

4

-

-

... More
SUPPLY OF MANDATORY SPARE FOR HV TERMINATION KITS INCLUDING LUGS AND HV CABLE END TERMINATIONS

-

-

-

... More
33/33 KV, 1C X 500 Sqmm (OD approx.: 62 +/- 2.0 mm)- INDOOR

5

-

-

... More
33/33 KV, 1C X 630 Sqmm (OD approx.: 65.5 +/- 2.0 mm)- INDOOR

5

-

-

... More
11/11kV , 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 53.5 +/- 2.0 mm)-INDOOR

5

-

-

... More
6.6/6.6 KV, 1C X 400 Sqmm (OD approx.: 41.5 +/- 2.0 mm)- INDOOR

5

-

-

... More
6.6/6.6 KV, 1C X 500 Sqmm (OD approx.: 44.5 +/- 2.0 mm)- INDOOR

10

-

-

... More
6.6/6.6 KV, 1C X 630 Sqmm (OD approx.: 48 +/- 2.0 mm)- INDOOR

5

-

-

... More
6.6/6.6 KV, 3C X 240 Sqmm (OD approx.: 76 +/- 2.0 mm)- INDOOR

3

-

-

... More
6.6/6.6 KV, 3C X 300 Sqmm (OD approx.: 81 +/- 2.0 mm)- INDOOR

3

-

-

... More
6.6/6.6 KV, 1C X 630 Sqmm (OD approx.: 48 +/- 2.0 mm)- OUTDOOR

3

-

-

... More
6.6/6.6 KV, 3C X 240 Sqmm (OD approx.: 76 +/- 2.0 mm)- OUTDOOR

3

-

-

... More
SUPPLY OF CABLE GLANDS INCLUDING LUGS AND CABLE END TERMINATIONS: Supply of double compression Nickel plated brass cable gland and termination of XLPE insulated MV/LV cables, Flame /Weather proof glands including cutting and stripping of cable insulation, fixing compression type lugs and crimping the lugs onto the conductor, restoration of the insulation, fixing of cable glands (including drilling of suitable holes in equipment for fixing purpose), connection of leads, clamping,including anti tracking compound, installation and supply of ferrules, single core cable fixing clamps, cable ties, cable Aluminium tags, clamping of cores and earthing of armour & gland, supply & installation of PVC shrouds and PVC Hoods of required size for outdoor terminations including all labour and materials complete as per approved drawings, specification of this tender and direction of Engineer-in-charge. The contractor to also arrange suitable Stop Plugs for unused entry, if required. The cable glands shall have valid statutory approvals (from PESO) as applicable for the specified location. The cost for supply of suitable crimping type, heavy duty, long barrel type Alluminium / Copper lugs and bimetallic strip (if required) shall be included in termination, no separate payment shall be made for cable lugs & bimetallic strips. All supplied lugs shall be of heavy duty long barrel type.

-

-

-

... More
CABLE GLANDS- FLAME PROOF TYPE: Double compression Nickel plated brass cable gland suitable for outdoor, with soft sealing nylon washer, locknut, shrouded & earth tag, Flame proof Ex'd , Zone-1/Zone 2, Gas group IIA, IIB, IIC , IP65, for 1.1KV Grade, XLPE insulated, Aluminium / Copper Armoured cable for following size as per specification no. NR-0ZZZZ-EL-SPE-0023 , approved drawings and directions of Engineer-in-Charge. The cable glands shall have valid statutory approvals (from PESO) as applicable for the specified location. NOTE: Exact OD of cables will be shared during detail engineering. Selection of correct size of cable gland with suitable thread (Metric) shall be selected as per site condition (cable gland entry) for the cable data provided during detail engineering is contractor's responsiblity. Any incorrect selection of cable gland shall be replaced by contractor at no cost and time implication to purchaser.

-

-

-

... More
6.6/6.6 KV, 3C X 240 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 76 +/- 2.0 mm)

18

-

-

... More
6.6/6.6 KV, 3C X 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 81 +/- 2.0 mm)

10

-

-

... More
6.6/6.6 KV, 1C X 400 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 41.5 +/- 2.0 mm)

10

-

-

... More
6.6/6.6 KV, 1C X 500 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 44.5 +/- 2.0 mm)

10

-

-

... More
6.6/6.6 KV, 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 48 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 3C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 14.5 +/- 2.0 mm)

90

-

-

... More
1.1 KV, 3C x 4 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 16.1 +/- 2.0 mm)

100

-

-

... More
1.1 KV, 7C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 15.9 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 12C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 21.5 +/- 2.0 mm)

100

-

-

... More
1.1 KV, 8T x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 21.5 +/- 2.0 mm)

20

-

-

... More
1.1KV, 1C x 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 43 +/- 2.0 mm)

20

-

-

... More
1.1KV, 1C x 500 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 39.5 +/- 2.0 mm)

10

-

-

... More
1.1KV, 3C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 32 +/- 2.0 mm)

20

-

-

... More
1.1KV, 3C x 95 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 37.5 +/- 2.0 mm)

10

-

-

... More
1.1KV, 3C x 150 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 43.5 +/- 2.0 mm)

10

-

-

... More
1.1KV, 3C x 185 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 48.5 +/- 2.0 mm)

20

-

-

... More
1.1KV, 3C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 53 +/- 2.0 mm)

10

-

-

... More
1.1KV, 3C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 57.5+/- 2.0 mm)

35

-

-

... More
1.1KV, 4C x 35 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 26.5 +/- 2.0 mm)

40

-

-

... More
1.1KV, 4C x 50 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 29.5 +/- 2.0 mm)

25

-

-

... More
1.1KV, 4C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 34 +/- 2.0 mm)

13

-

-

... More
1.1KV, 4C x 95 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 38 +/- 2.0 mm)

15

-

-

... More
1.1KV, 4C x 120 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 42 +/- 2.0 mm)

10

-

-

... More
1.1KV, 4C x 150 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 47 +/- 2.0 mm)

10

-

-

... More
1.1KV, 4C x 185 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 52 +/- 2.0 mm)

10

-

-

... More
1.1KV, 4C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 57.5 +/- 2.0 mm)

10

-

-

... More
1.1KV, 4C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 64.5 +/- 2.0 mm)

10

-

-

... More
SUPPLY OF MANDATORY SPARE FOR CABLE GLANDS- FLAME PROOF TYPE

-

-

-

... More
6.6/6.6 KV, 3C X 240 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 76 +/- 2.0 mm)

6

-

-

... More
1.1 KV, 3C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 14.5 +/- 2.0 mm)

50

-

-

... More
1.1 KV, 3C x 4 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 16.1 +/- 2.0 mm)

50

-

-

... More
1.1 KV, 7C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 15.9 +/- 2.0 mm)

6

-

-

... More
1.1 KV, 12C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 21.5 +/- 2.0 mm)

50

-

-

... More
1.1 KV, 8T x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 21.5 +/- 2.0 mm)

6

-

-

... More
1.1KV, 1C x 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 43 +/- 2.0 mm)

6

-

-

... More
1.1KV, 1C x 500 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 39.5 +/- 2.0 mm)

4

-

-

... More
1.1KV, 3C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 32 +/- 2.0 mm)

4

-

-

... More
1.1KV, 3C x 95 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 37.5 +/- 2.0 mm)

4

-

-

... More
1.1KV, 3C x 150 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 43.5 +/- 2.0 mm)

4

-

-

... More
1.1KV, 3C x 185 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 48.5 +/- 2.0 mm)

4

-

-

... More
1.1KV, 3C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 53 +/- 2.0 mm)

4

-

-

... More
1.1KV, 3C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 57.5+/- 2.0 mm)

4

-

-

... More
1.1KV, 4C x 35 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 26.5 +/- 2.0 mm)

10

-

-

... More
CABLE GLANDS- INDUSTRIAL TYPE: Double compression Nickel plated brass cable gland suitable for outdoor, with soft sealing nylon washer, locknut, shrouded & earth tag, Weather proof, IP65, for Aluminium / Copper Armoured cable for following size, as per specification no. NR-0ZZZZ-EL-SPE-0023 , approved drawings and directions of Engineer-in-Charge. NOTE: Exact OD of cables will be shared during detail engineering. Selection of correct size of cable gland with suitable thread (Metric) shall be selected as per site condition (cable gland entry) for the cable data provided during detail engineering is contractor's responsiblity. Any incorrect selection of cable gland shall be replaced by contractor at no cost and time implication to purchaser.

-

-

-

... More
33/33 KV, 1C X 500 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 62 +/- 2.0 mm)

6

-

-

... More
33/33 KV, 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 65.5 +/- 2.0 mm)

6

-

-

... More
11/11kV , 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 48 +/- 2.0 mm)

6

-

-

... More
6.6/6.6 KV, 3C X 240 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 76 +/- 2.0 mm)

4

-

-

... More
6.6/6.6 KV, 3C X 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 81 +/- 2.0 mm)

4

-

-

... More
6.6/6.6 KV, 1C X 400 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 41.5 +/- 2.0 mm)

6

-

-

... More
6.6/6.6 KV, 1C X 500 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 44.5 +/- 2.0 mm)

6

-

-

... More
6.6/6.6 KV, 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 48 +/- 2.0 mm)

6

-

-

... More
1.1KV, 1C x 400 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 35.5 +/- 2.0 mm)

70

-

-

... More
1.1KV, 1C x 500 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 39.5 +/- 2.0 mm)

600

-

-

... More
1.1KV, 1C x 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 43 +/- 2.0 mm)

270

-

-

... More
1.1 KV, 3C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 14 +/- 2.0 mm)

360

-

-

... More
1.1 KV, 3C x 4 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 16 +/- 2.0 mm)

600

-

-

... More
1.1 KV, 3C x 6 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 17 +/- 2.0 mm)

200

-

-

... More
1.1 KV, 3C x 10 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 19 +/- 2.0 mm)

200

-

-

... More
1.1 KV, 3C x 16 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 18.8 +/- 2.0 mm)

290

-

-

... More
1.1 KV, 3C x 25 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 21.7 +/- 2.0 mm)

100

-

-

... More
1.1KV, 3C x 35 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 23.6 +/- 2.0 mm)

30

-

-

... More
1.1KV, 3C x 50 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 26.8 +/- 2.0 mm)

30

-

-

... More
1.1KV, 3C x 70 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 30.9 +/- 2.0 mm)

35

-

-

... More
1.1KV, 3C x 95 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 33.7 +/- 2.0 mm)

35

-

-

... More
1.1KV, 3C x 120 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 37 +/- 2.0 mm)

30

-

-

... More
1.1KV, 3C x 150 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 41.1 +/- 2.0 mm)

50

-

-

... More
1.1KV, 3C x 185 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 46 +/- 2.0 mm)

30

-

-

... More
1.1KV, 3C x 240 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 50.9 +/- 2.0 mm)

80

-

-

... More
1.1KV, 3C x 300 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 55.45 +/- 2.0 mm)

80

-

-

... More
1.1 KV, 4C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 14 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 4C x 4 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 16 +/- 2.0 mm)

80

-

-

... More
1.1 KV, 4C x 6 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 17.3 +/- 2.0 mm)

50

-

-

... More
1.1 KV, 4C x 10 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 19.8 +/- 2.0 mm)

70

-

-

... More
1.1 KV, 4C x 16 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 21 +/- 2.0 mm)

80

-

-

... More
1.1 KV, 4C x 25 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 25 +/- 2.0 mm)

60

-

-

... More
1.1KV, 4C x 50 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 29.5 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 3C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 14 +/- 2.0 mm)

10

-

-

... More
1.1KV, 3C x 25 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 21.7 +/- 2.0 mm)

10

-

-

... More
1.1KV, 3C x 35 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 23.6 +/- 2.0 mm)

50

-

-

... More
1.1KV, 3C x 50 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 26.8 +/- 2.0 mm)

70

-

-

... More
1.1KV, 3C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 30.9 +/- 2.0 mm)

60

-

-

... More
1.1KV, 3C x 95 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 33.7 +/- 2.0 mm)

60

-

-

... More
1.1KV, 3C x 120 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 37 +/- 2.0 mm)

40

-

-

... More
1.1KV, 3C x 150 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 41.1 +/- 2.0 mm)

70

-

-

... More
1.1KV, 3C x 185 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 46 +/- 2.0 mm)

70

-

-

... More
1.1KV, 3C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 50.9 +/- 2.0 mm)

95

-

-

... More
1.1KV, 3C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 55.45 +/- 2.0 mm)

120

-

-

... More
1.1KV, 4C x 25 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 25 +/- 2.0 mm)

10

-

-

... More
1.1KV, 4C x 35 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 26.5 +/- 2.0 mm)

180

-

-

... More
1.1KV, 4C x 50 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 29.5 +/- 2.0 mm)

50

-

-

... More
1.1KV, 4C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 34 +/- 2.0 mm)

30

-

-

... More
1.1KV, 4C x 95 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 38 +/- 2.0 mm)

60

-

-

... More
1.1KV, 4C x 120 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 42 +/- 2.0 mm)

110

-

-

... More
1.1KV, 4C x 150 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 47 +/- 2.0 mm)

50

-

-

... More
1.1KV, 4C x 185 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 52 +/- 2.0 mm)

50

-

-

... More
1.1KV, 4C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 57.5 +/- 2.0 mm)

110

-

-

... More
1.1KV, 4C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 64.5 +/- 2.0 mm)

140

-

-

... More
1.1 KV, 5C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 14.9 +/- 2.0 mm)

300

-

-

... More
1.1 KV, 7C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 15.9 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 9C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 18.5 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 12C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 20.1 +/- 2.0 mm)

450

-

-

... More
1.1 KV, 19C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 22.8 +/- 2.0 mm)

160

-

-

... More
1.1 KV, 2P x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 18.4 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 6P x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 25.5 +/- 2.0 mm)

320

-

-

... More
1.1 KV, 12P x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 32.5 +/- 2.0 mm)

75

-

-

... More
1.1 KV, 8T x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 25.1 +/- 2.0 mm)

25

-

-

... More
12 Fibres, Multi tube, Single mode 9/125 µm, Fire resistant, Armoured Fibre Optic Cable as per ITU-T-G652D recommendations. (OD approx.: 11 +/- 2.0 mm)

150

-

-

... More
8 Fibres, Multi loose tube, Multi mode 9/125 µm, Fire resistant, Armoured Fibre Optic Cable as per ITU-T-G652D recommendations. (OD approx.: 10 +/- 2.0 mm)

300

-

-

... More
6 Fibres, Multi loose tube, Single mode 9/125 µm, Fire resistant, Armoured Fibre Optic Cable as per ITU-T-G652D recommendations. (OD approx.: 14 +/- 2.0 mm)

30

-

-

... More
02 Pairs, 24 AWG, Individual and Collective shield, Fire resistant, Galvanised Steel wired Armoured, RS 485 Cable (OD approx.: 8 +/- 2.0 mm)

150

-

-

... More
04 Pairs, 23 AWG, U/STP, Fire Resistance, Galvanised steel wire armoured cable, CAT6 Cable (OD approx.: 10 +/- 2.0 mm)

100

-

-

... More
SUPPLY OF MANDATORY SPARE FOR CABLE GLANDS- INDUSTRIAL TYPE

-

-

-

... More
1.1KV, 1C x 400 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 35.5 +/- 2.0 mm)

6

-

-

... More
1.1KV, 1C x 500 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 39.5 +/- 2.0 mm)

10

-

-

... More
1.1KV, 1C x 630 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 43 +/- 2.0 mm)

6

-

-

... More
1.1 KV, 3C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 14 +/- 2.0 mm)

100

-

-

... More
1.1 KV, 3C x 4 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 16 +/- 2.0 mm)

100

-

-

... More
1.1 KV, 3C x 6 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 17 +/- 2.0 mm)

50

-

-

... More
1.1 KV, 3C x 10 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 19 +/- 2.0 mm)

50

-

-

... More
1.1 KV, 3C x 16 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 18.8 +/- 2.0 mm)

50

-

-

... More
1.1 KV, 3C x 25 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 21.7 +/- 2.0 mm)

50

-

-

... More
1.1KV, 3C x 240 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 50.9 +/- 2.0 mm)

6

-

-

... More
1.1KV, 3C x 300 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 55.45 +/- 2.0 mm)

6

-

-

... More
1.1 KV, 4C x 4 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 16 +/- 2.0 mm)

6

-

-

... More
1.1 KV, 4C x 6 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 17.3 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 4C x 10 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 19.8 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 4C x 16 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 21 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 4C x 25 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 25 +/- 2.0 mm)

10

-

-

... More
1.1KV, 3C x 35 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 23.6 +/- 2.0 mm)

6

-

-

... More
1.1KV, 3C x 50 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 26.8 +/- 2.0 mm)

6

-

-

... More
1.1KV, 3C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 30.9 +/- 2.0 mm)

6

-

-

... More
1.1KV, 3C x 95 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 33.7 +/- 2.0 mm)

6

-

-

... More
1.1KV, 3C x 120 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 37 +/- 2.0 mm)

6

-

-

... More
1.1KV, 3C x 150 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 41.1 +/- 2.0 mm)

6

-

-

... More
1.1KV, 3C x 185 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 46 +/- 2.0 mm)

6

-

-

... More
1.1KV, 3C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 50.9 +/- 2.0 mm)

6

-

-

... More
1.1KV, 3C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 55.45 +/- 2.0 mm)

6

-

-

... More
1.1KV, 4C x 35 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 26.5 +/- 2.0 mm)

50

-

-

... More
1.1KV, 4C x 50 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 29.5 +/- 2.0 mm)

6

-

-

... More
1.1KV, 4C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 34 +/- 2.0 mm)

6

-

-

... More
1.1KV, 4C x 95 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 38 +/- 2.0 mm)

6

-

-

... More
1.1KV, 4C x 120 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 42 +/- 2.0 mm)

6

-

-

... More
1.1KV, 4C x 150 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 47 +/- 2.0 mm)

6

-

-

... More
1.1KV, 4C x 185 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 52 +/- 2.0 mm)

6

-

-

... More
1.1KV, 4C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 57.5 +/- 2.0 mm)

6

-

-

... More
1.1KV, 4C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS (OD approx.: 64.5 +/- 2.0 mm)

6

-

-

... More
1.1 KV, 5C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 14.9 +/- 2.0 mm)

50

-

-

... More
1.1 KV, 12C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 20.1 +/- 2.0 mm)

50

-

-

... More
1.1 KV, 19C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 22.8 +/- 2.0 mm)

30

-

-

... More
1.1 KV, 6P x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 25.5 +/- 2.0 mm)

50

-

-

... More
1.1 KV, 12P x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 32.5 +/- 2.0 mm)

10

-

-

... More
1.1 KV, 8T x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS (OD approx.: 25.1 +/- 2.0 mm)

6

-

-

... More
12 Fibres, Multi tube, Single mode 9/125 µm, Fire resistant, Armoured Fibre Optic Cable as per ITU-T-G652D recommendations.(OD approx.: 11 +/- 2.0 mm)

30

-

-

... More
8 Fibres, Multi loose tube, Multi mode 9/125 µm, Fire resistant, Armoured Fibre Optic Cable as per ITU-T-G652D recommendations. (OD approx.: 10 +/- 2.0 mm)

30

-

-

... More
02 Pairs, 24 AWG, Individual and Collective shield, Fire resistant, Galvanised Steel wired Armoured, RS 485 Cable (OD approx.: 8 +/- 2.0 mm)

30

-

-

... More
04 Pairs, 23 AWG, U/STP, Fire Resistance, Galvanised steel wire armoured cable, CAT6 Cable (OD approx.: 10 +/- 2.0 mm)

30

-

-

... More
SUPPLY AND MAKING OF STRAIGHT THROUGH JOINTING KIT FOR HV CABLES: Supply and making of heat shrinkable type straight through jointing kits outdoor and accessories for Unearthed grade H.V. cables including supply of all accessories required and cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, including all labour and materials, of the following sizes, as per specification no. NR-0ZZZZ-EL-SPE-0023 , approved drawings and directions of Engineer-in-Charge.

-

-

-

... More
33KV/33KV, 1C X 500 Sqmm, AL, XLPE, Armoured, PVC FRLS

6

-

-

... More
33KV/33KV, 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

240

-

-

... More
11KV/11KV, 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

3

-

-

... More
11kV/6.35kV, 3C X 185 Sqmm, AL, XLPE, Armoured, PVC FRLS

6

-

-

... More
6.6KV/6.6KV, 1C X 400 Sqmm, AL, XLPE, Armoured, PVC FRLS

3

-

-

... More
6.6KV/6.6KV, 1C X 500 Sqmm, AL, XLPE, Armoured, PVC FRLS

12

-

-

... More
6.6KV/6.6KV, 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

72

-

-

... More
6.6KV/6.6KV, 3C X 240 Sqmm, AL, XLPE, Armoured, PVC FRLS

2

-

-

... More
6.6KV/6.6KV, 3C X 300 Sqmm, AL, XLPE, Armoured, PVC FRLS

2

-

-

... More
SUPPLY OF MANDATORY SPARE FOR STRAIGHT THROUGH JOINTING KIT FOR HV CABLES

-

-

-

... More
33KV/33KV, 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

10

-

-

... More
6.6KV/6.6KV, 1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

6

-

-

... More
STRAIGHT THROUGH JOINTING FOR MV CABLES: Supply and making of heat shrinkable type straight through jointing kits outdoor and accessories for MV/LV cables including supply of all accessories required, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, including all labour and materials,of the following sizes, as per specification no. NR-0ZZZZ-EL-SPE-0023 , approved drawings and directions of Engineer-in-Charge.

-

-

-

... More
MEDIUM VOLTAGE POWER CABLES- ALUMINIUM

-

-

-

... More
1.1KV, 1C x 400 Sqmm, AL, XLPE, Armoured, PVC FRLS

3

-

-

... More
1.1KV, 1C x 500 Sqmm, AL, XLPE, Armoured, PVC FRLS

3

-

-

... More
1.1KV, 1C x 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

3

-

-

... More
1.1KV, 3C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS

38

-

-

... More
1.1KV, 3C x 95 Sqmm, AL, XLPE, Armoured, PVC FRLS

38

-

-

... More
1.1KV, 3C x 120 Sqmm, AL, XLPE, Armoured, PVC FRLS

2

-

-

... More
1.1KV, 3C x 150 Sqmm, AL, XLPE, Armoured, PVC FRLS

4

-

-

... More
1.1KV, 3C x 185 Sqmm, AL, XLPE, Armoured, PVC FRLS

14

-

-

... More
1.1KV, 3C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS

2

-

-

... More
1.1KV, 3C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS

26

-

-

... More
1.1KV, 4C X 25 Sqmm, AL, XLPE, Armoured, PVC FRLS

2

-

-

... More
1.1KV, 4C X 35 Sqmm, AL, XLPE, Armoured, PVC FRLS

5

-

-

... More
1.1KV, 4C X 50 Sqmm, AL, XLPE, Armoured, PVC FRLS

4

-

-

... More
1.1KV, 4C X 70 Sqmm, AL, XLPE, Armoured, PVC FRLS

4

-

-

... More
1.1KV, 4C X 95 Sqmm, AL, XLPE, Armoured, PVC FRLS

12

-

-

... More
1.1KV, 4C X 120 Sqmm, AL, XLPE, Armoured, PVC FRLS

2

-

-

... More
1.1KV, 4C x 150 Sqmm, AL, XLPE, Armoured, PVC FRLS

3

-

-

... More
1.1KV, 4C X 185 Sqmm, AL, XLPE, Armoured, PVC FRLS

2

-

-

... More
1.1KV, 4C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS

2

-

-

... More
1.1KV, 4C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS

2

-

-

... More
Supply & Installation of Fibre optical cable jointer ( outdoor joint enclosure)

-

-

-

... More
12 Fibres, Multi tube, Single mode 9/125 µm, Fire resistant, Armoured Fibre Optic Cable Jointer ( with outdoor joint enclosure)

10

-

-

... More
8 Fibres, Multi loose tube, Multi mode 9/125 µm, Fire resistant, Armoured Fibre Optic Cable ( with outdoor joint enclosure)

10

-

-

... More
6 Fibres, Multi loose tube, Single mode 9/125 µm, Fire resistant, Armoured Fibre Optic Cable ( with outdoor joint enclosure)

2

-

-

... More
SUPPLY & INSTALLATION OF PVC GLANDS FOR MEDIUM VOLTAGE POWER CABLES

-

-

-

... More
M12 X 1.5 mm

100

-

-

... More
M16 X 1.5 mm

100

-

-

... More
M20 X 1.5 mm

200

-

-

... More
M25 X 1.5 mm

200

-

-

... More
M32 X 1.5 mm

40

-

-

... More
M40 X 1.5 mm

40

-

-

... More
M50 X 1.5 mm

30

-

-

... More
M63 X 1.5 mm

30

-

-

... More
SUPPLY OF MANDATORY SPARE FOR MEDIUM VOLTAGE POWER CABLES- ALUMINIUM

-

-

-

... More
1.1KV, 3C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS

4

-

-

... More
1.1KV, 3C x 95 Sqmm, AL, XLPE, Armoured, PVC FRLS

4

-

-

... More
CABLE MARKERS

-

-

-

... More
Supply and installation of cable markers for buried HV/MV cable at the interval of 30M, at every bend & at every cable joint location and associated materials including engraving "BURIED ELECTRIC CABLES HT/LT" along with complete support and foundation and painting as per approved drawing, specification of this tender,TP-1ZZZA-EL-STC-0002- Typical Power Installation Standards For Construction and directions of Engineer-in-charge.

30

-

-

... More
ADAPTORS/REDUCERS-WEATHER PROOF: Supply and fixng of weatherproof, nickel-plated brass adaptors/reducers for cable termination to equipments if required,

-

-

-

... More
ADAPTORS

-

-

-

... More
M20 to M32

20

-

-

... More
M25 to M32

20

-

-

... More
M25 to M40

20

-

-

... More
M32 to M40

20

-

-

... More
M40 to M50

20

-

-

... More
M40 to M63

20

-

-

... More
M40 to M75

20

-

-

... More
REDUCER

-

-

-

... More
M32 to M25

20

-

-

... More
M40 to M25

20

-

-

... More
M50 to M40

20

-

-

... More
M63 to M40

20

-

-

... More
ADAPTORS/REDUCERS-FLAME PROOF: Supply of FLP(IIA/IIB & IIC) nickel-plated brass adaptors/reducers for cable termination to equipments if required,

-

-

-

... More
ADAPTORS (Metric thread)

-

-

-

... More
M20 to M32

20

-

-

... More
M25 to M32

20

-

-

... More
M25 to M40

20

-

-

... More
M32 to M40

20

-

-

... More
M40 to M50

20

-

-

... More
M40 to M63

20

-

-

... More
M40 to M75

20

-

-

... More
REDUCER (Metric thread)

-

-

-

... More
M32 to M25

20

-

-

... More
M40 to M25

20

-

-

... More
M50 to M40

20

-

-

... More
M63 to M40

20

-

-

... More
CABLING SYSTEM- INSTALLATION, TESTING & COMMISSIONING: The Contractor scope includes, laying of cables (using cable pulling by motorized winch with torque limits),installation,testing & commissioning of different voltage grade and types of the following cables in ready trays/trenches/racks/underground/buried/ cable duct bank / road crossing / supported on structure/pull through pipes,clamping to column wall or structure using GI spacers and saddles (at an interval of 300 mm), Installation & supply of anodise Aluminium / Stainless steel tags for overhead & buried cables respectively. Installation & supply of G.I saddles & G.I Clamps, cable tie, clamping of cables on trays & necessary hardwares. Cables laid in trays shall be dressed and clamped using GI Clamps at every 750 mm. Scope shall include opening the RCC slabs/Covers from Cable Trenches before laying and replacing them after laying. including supply and fixing of stainless steel/aluminium/lead strip number tags, cable ferrules, certified trefoil clamps of non-magnetic material for 1C cables, cable tie, etc., fixing of RFID tags for underground cables.The cable shall be installed as per Doc. No.: NR-0ZZZZ-EL-SPE-0031 Specification for Electrical Cable Installation. The cable laying work shall include transportation of cable drums from owner's issue point to the place of installation by contractor's own lifting & transportation arrangement, unpacking, cable cutting as per actual length measurement & cable schedule/cable drum schedule, return of unused cable/drums to the owner's store & removal of empty drum to Owner's Scrap Yard, including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-charge. Contractor shall provide necessary assistance for CEA approval, if required. NOTE: Cables shall be supplied to the CONTRACTOR as free issue material at Site store/yard

-

-

-

... More
HIGH VOLTAGE POWER CABLES- ALUMINIUM

-

-

-

... More
33KV/33KV Unearthed Power Cables, Stranded aluminium conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed, conductor and insulation screened

-

-

-

... More
1C X 500 Sqmm, AL, XLPE, Armoured, PVC FRLS

10000

-

-

... More
1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

150000

-

-

... More
6.6KV/6.6KV Unearthed Power Cables, Stranded aluminium conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed, conductor and insulation screened

-

-

-

... More
1C X 400 Sqmm, AL, XLPE, Armoured, PVC FRLS

6700

-

-

... More
1C X 500 Sqmm, AL, XLPE, Armoured, PVC FRLS

22700

-

-

... More
1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

65700

-

-

... More
3C X 50 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
3C X 150 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
3C X 185 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
3C X 240 Sqmm, AL, XLPE, Armoured, PVC FRLS

15000

-

-

... More
3C X 300 Sqmm, AL, XLPE, Armoured, PVC FRLS

1000

-

-

... More
11KV/11KV Unearthed Power Cables, Stranded aluminium conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed, conductor and insulation screened

-

-

-

... More
1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

10000

-

-

... More
3C X 185 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
3C X 240 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
3C X 300 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
11KV/11KV Unearthed Power Cables, Stranded copper conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed, conductor and insulation screened

-

-

-

... More
1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
MEDIUM VOLTAGE POWER CABLES- ALUMINIUM: 1.1KV Grade Power Cable, Stranded Aluminium conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed

-

-

-

... More
1C X 400 Sqmm, AL, XLPE, Armoured, PVC FRLS

3300

-

-

... More
1C X 500 Sqmm, AL, XLPE, Armoured, PVC FRLS

25200

-

-

... More
1C X 630 Sqmm, AL, XLPE, Armoured, PVC FRLS

17100

-

-

... More
3C x 25 Sqmm, AL, XLPE, Armoured, PVC FRLS

8400

-

-

... More
3C x 35 Sqmm, AL, XLPE, Armoured, PVC FRLS

19500

-

-

... More
3C X 50 Sqmm, AL, XLPE, Armoured, PVC FRLS

5300

-

-

... More
3C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS

1700

-

-

... More
3C x 95 Sqmm, AL, XLPE, Armoured, PVC FRLS

10900

-

-

... More
3C x 120 Sqmm, AL, XLPE, Armoured, PVC FRLS

10800

-

-

... More
3C X 150 Sqmm, AL, XLPE, Armoured, PVC FRLS

11800

-

-

... More
3C X 185 Sqmm, AL, XLPE, Armoured, PVC FRLS

27700

-

-

... More
3C X 240 Sqmm, AL, XLPE, Armoured, PVC FRLS

19000

-

-

... More
3C X 300 Sqmm, AL, XLPE, Armoured, PVC FRLS

42700

-

-

... More
4C x 25 Sqmm, AL, XLPE, Armoured, PVC FRLS

21200

-

-

... More
4C x 35 Sqmm, AL, XLPE, Armoured, PVC FRLS

20000

-

-

... More
4C x 50 Sqmm, AL, XLPE, Armoured, PVC FRLS

25400

-

-

... More
4C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS

17900

-

-

... More
4C X 95 Sqmm, AL, XLPE, Armoured, PVC FRLS

18600

-

-

... More
4C X 120 Sqmm, AL, XLPE, Armoured, PVC FRLS

19400

-

-

... More
4C x 150 Sqmm, AL, XLPE, Armoured, PVC FRLS

5600

-

-

... More
4C X 185 Sqmm, AL, XLPE, Armoured, PVC FRLS

3600

-

-

... More
4C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS

34500

-

-

... More
4C x 300 Sqmm, AL, XLPE, Armoured, PVC FRLS

20900

-

-

... More
2C x 240 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
3.5C x 50 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
3.5C x 70 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
3.5C X 240 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
3.5C X 300 Sqmm, AL, XLPE, Armoured, PVC FRLS

50

-

-

... More
MEDIUM VOLTAGE POWER CABLES- COPPER: 1.1 KV Grade Power Cable, Stranded Copper conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed

-

-

-

... More
2C x 6 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 10 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 16 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 25 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 35 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 50 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 70 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 95 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 120 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C X 150 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 185 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 240 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
2C x 300 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
3C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS

40000

-

-

... More
3C x 4 Sqmm, CU, XLPE, Armoured, PVC FRLS

90400

-

-

... More
3C x 6 Sqmm, CU, XLPE, Armoured, PVC FRLS

14000

-

-

... More
3C x 10 Sqmm, CU, XLPE, Armoured, PVC FRLS

19000

-

-

... More
3C x 16 Sqmm, CU, XLPE, Armoured, PVC FRLS

12000

-

-

... More
3C x 25 Sqmm, CU, XLPE, Armoured, PVC FRLS

3000

-

-

... More
3C x 35 Sqmm, CU, XLPE, Armoured, PVC FRLS

1200

-

-

... More
3C x 50 Sqmm, CU, XLPE, Armoured, PVC FRLS

2100

-

-

... More
3C x 70 Sqmm, CU, XLPE, Armoured, PVC FRLS

1600

-

-

... More
3C x 95 Sqmm, CU, XLPE, Armoured, PVC FRLS

1200

-

-

... More
3C x 120 Sqmm, CU, XLPE, Armoured, PVC FRLS

1100

-

-

... More
3C X 150 Sqmm, CU, XLPE, Armoured, PVC FRLS

2600

-

-

... More
3C x 185 Sqmm, CU, XLPE, Armoured, PVC FRLS

2400

-

-

... More
3C x 240 Sqmm, CU, XLPE, Armoured, PVC FRLS

2200

-

-

... More
3C x 300 Sqmm, CU, XLPE, Armoured, PVC FRLS

1900

-

-

... More
4C x 4 Sqmm, CU, XLPE, Armoured, PVC FRLS

3200

-

-

... More
4C x 6 Sqmm, CU, XLPE, Armoured, PVC FRLS

4500

-

-

... More
4C x 10 Sqmm, CU, XLPE, Armoured, PVC FRLS

9200

-

-

... More
4C x 16 Sqmm, CU, XLPE, Armoured, PVC FRLS

3600

-

-

... More
4C x 25 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
4C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS

500

-

-

... More
3.5C x 50 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
CONTROL CABLES- COPPER: 1.1KV Grade Control Cable, Stranded Copper conductor, XLPE insulated, extruded PVC inner sheathed, armoured & extruded FRLS PVC outer sheathed

-

-

-

... More
3C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS

80000

-

-

... More
3C x 4 Sqmm, CU, XLPE, Armoured, PVC FRLS

10000

-

-

... More
5C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS

14300

-

-

... More
7C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
9C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
12C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS

119300

-

-

... More
19C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS

7000

-

-

... More
10C x 2.5 Sqmm, CU, XLPE, Armoured, PVC FRLS

50

-

-

... More
PAIRED SCREENCABLES

-

-

-

... More
2 Paired, 2.5sq.mm, Copper, each pair & overall shielded, PVC/FRLS Low halogen sheath, primary XLPE conductor insulation, Steel wire Armoured, Non intrinsically safe cables.

1000

-

-

... More
4 Paired, 2.5sq.mm, Copper, each pair & overall shielded, PVC/FRLS Low halogen sheath, primary XLPE conductor insulation, Steel wire Armoured, Non intrinsically safe cables.

50

-

-

... More
6 Paired, 2.5sq.mm, Copper, each pair & overall shielded, PVC/FRLS Low halogen sheath, primary XLPE conductor insulation, Steel wire Armoured., Non intrinsically safe cables.

18000

-

-

... More
8 Paired, 2.5sq.mm, Copper, each pair & overall shielded, PVC/FRLS Low halogen sheath, primary XLPE conductor insulation, Steel wire Armoured, Non intrinsically safe cables.

50

-

-

... More
10 Paired, 2.5sq.mm, Copper, each pair & overall shielded, PVC/FRLS Low halogen sheath, primary XLPE conductor insulation, Steel wire Armoured, Non intrinsically safe cables.

50

-

-

... More
12 Paired, 2.5sq.mm, Copper, each pair & overall shielded, PVC/FRLS Low halogen sheath, primary XLPE conductor insulation, Steel wire Armoured, Non intrinsically safe cables.

8000

-

-

... More
3 Paired, 2.5sq.mm, Copper, each pair & overall shielded, PVC/FRLS Low halogen sheath, primary XLPE conductor insulation, Steel wire Armoured, Non intrinsically safe cables.

50

-

-

... More
14 Paired, 2.5sq.mm, Copper, each pair & overall shielded, PVC/FRLS Low halogen sheath, primary XLPE conductor insulation, Steel wire Armoured, Non intrinsically safe cables.

50

-

-

... More
TRIAD CABLES

-

-

-

... More
1 Triad, 2.5sq.mm, Copper, overall shield. XLPE, Fire Resistant Low Smoke zero halogen Sheath, Steel wire outdoor Armoured, Non intrinsically safe cables.

50

-

-

... More
8 Triad, Copper, 2.5sq.mm overall shield. XLPE, Fire Resistant Low Smoke zero halogen Sheath, Steel wire outdoor Armoured, Non intrinsically safe cables.

13000

-

-

... More
FIBRE OPTICS CABLES

-

-

-

... More
12 Fibres, Multi loose tube, Single mode 9/125 µm, Fire resistant, Armoured Fibre Optic Cable as per ITU-T-G652D recommendations.

65000

-

-

... More
8 Fibres, Multi loose tube, Single mode 9/125 µm, Fire resistant, Armoured Fibre Optic Cable as per ITU-T-G652D recommendations.

27000

-

-

... More
MODBUS CABLES AND ETHERNET CABLE

-

-

-

... More
02 Pairs, 24 AWG, Individual and Collective shield, Fire resistant, Galvanised Steel wired Armoured, RS 485 Cable

5200

-

-

... More
04 Pairs, 23 AWG, U/STP, Fire Resistance, Galvanised steel wire armoured cable, CAT6 Cable

5200

-

-

... More
CABLE TRAY SYSTEM- INSTALLATION: Installation of the cable trays including transportation from store/yard to site at the place of installation, unpacking,cable trays, fittings, covers,.etc. complete with necessary splice plates,Cable Tray Hold Down Clamps, with required bolt, nut & washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. NOTE: The following items shall be supplied to the Contractor as free issue material’s site-store / yard

-

-

-

... More
STRAIGHT RUN CABLE LADDER- Hot Dip galvanized GI

-

-

-

... More
750(W) X 100(H) mm Straight Run Cable Ladder, each at 3m Long.

6500

-

-

... More
600(W) X 100(H) mm Straight Run Cable Ladder, each at 3m Long.

122000

-

-

... More
300(W) X 100(H) mm Straight Run Cable Ladder, each at 3m Long.

1500

-

-

... More
150(W) X 100(H) mm Straight Run Cable Ladder, each at 3m Long.

810

-

-

... More
STRAIGHT RUN PERFORATED CABLE TRAY- Hot Dip galvanized GI

-

-

-

... More
100(W) X 50(H) mm Straight Run Perforated Cable tray, each at 3m Long.

1200

-

-

... More
50(W) X 50(H) mm Straight Run Perforated Cable tray, each at 3m Long.

1200

-

-

... More
CABLE TRAY COVERS- 1.6 mm Hot Dip Galvanised sheet

-

-

-

... More
750 mm Wide Straight Run Cable Ladder Cover

1600

-

-

... More
600 mm Wide Straight Run Cable Ladder Cover

42000

-

-

... More
300 mm Wide Straight Run Cable Ladder Cover

762

-

-

... More
150 mm Wide Straight Run Cable Ladder Cover

542

-

-

... More
100 mm Wide Straight Run Perforated Cable tray Cover

540

-

-

... More
50 mm Wide Straight Run Perforated Cable tray Cover

540

-

-

... More
30 DEGREE HORIZONTAL ELBOW- HDGI

-

-

-

... More
30 Deg Horizontal Bend, Ladder, 300mm Radius, 300(W) X 100(H) mm

20

-

-

... More
30 Deg Horizontal Bend, Ladder, 300mm Radius, 750(W) X 100(H) mm

40

-

-

... More
30 Deg Horizontal Bend, Ladder, 600mm Radius, 150(W) X 100(H) mm

20

-

-

... More
30 Deg Horizontal Bend, Ladder, 600mm Radius, 600(W) X 100(H) mm

20

-

-

... More
30 Deg Horizontal Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

50

-

-

... More
30 Deg Horizontal Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

350

-

-

... More
30 Deg Horizontal Bend, Ladder, 1200mm Radius, 750(W) X 100(H) mm

24

-

-

... More
30 Deg Horizontal Bend, 300 Rad, 300 W, Cover

20

-

-

... More
30 Deg Horizontal Bend, 300 Rad, 750 W, Cover

20

-

-

... More
30 Deg Horizontal Bend, 600 Rad, 150 W, Cover

20

-

-

... More
30 Deg Horizontal Bend, 600 Rad, 600 W, Cover

20

-

-

... More
30 Deg Horizontal Bend, 900 Rad, 600 W, Cover

30

-

-

... More
30 Deg Horizontal Bend, 1200 Rad, 600 W, Cover

200

-

-

... More
30 Deg Horizontal Bend, 1200 Rad, 750 W, Cover

20

-

-

... More
45 DEGREE HORIZONTAL ELBOW- HDGI

-

-

-

... More
45 Deg Horizontal Bend, Ladder, 300mm Radius, 150(W) X 100(H) mm

20

-

-

... More
45 Deg Horizontal Bend, Ladder, 300mm Radius, 600(W) X 100(H) mm

30

-

-

... More
45 Deg Horizontal Bend, Ladder, 600mm Radius, 150(W) X 100(H) mm

20

-

-

... More
45 Deg Horizontal Bend, Ladder, 600mm Radius, 600(W) X 100(H) mm

20

-

-

... More
45 Deg Horizontal Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

25

-

-

... More
45 Deg Horizontal Bend, Ladder, 900mm Radius, 750(W) X 100(H) mm

35

-

-

... More
45 Deg Horizontal Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

450

-

-

... More
45 Deg Horizontal Bend, Ladder, 1200mm Radius, 750(W) X 100(H) mm

60

-

-

... More
45 Deg Horizontal Bend, 300 Rad, 150 W, Cover

20

-

-

... More
45 Deg Horizontal Bend, 300 Rad, 600 W, Cover

20

-

-

... More
45 Deg Horizontal Bend, 600 Rad, 150 W, Cover

20

-

-

... More
45 Deg Horizontal Bend, 600 Rad, 600 W, Cover

20

-

-

... More
45 Deg Horizontal Bend, 900 Rad, 600 W, Cover

25

-

-

... More
45 Deg Horizontal Bend, 900 Rad, 750 W, Cover

20

-

-

... More
45 Deg Horizontal Bend, 1200 Rad, 600 W, Cover

200

-

-

... More
45 Deg Horizontal Bend, 1200 Rad, 750 W, Cover

35

-

-

... More
60 DEGREE HORIZONTAL ELBOW- HDGI

-

-

-

... More
60 Deg Horizontal Bend, Ladder, 600mm Radius, 150(W) X 100(H) mm

20

-

-

... More
60 Deg Horizontal Bend, Ladder, 600mm Radius, 300(W) X 100(H) mm

20

-

-

... More
60 Deg Horizontal Bend, Ladder, 900mm Radius, 750(W) X 100(H) mm

25

-

-

... More
60 Deg Horizontal Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

20

-

-

... More
60 Deg Horizontal Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

100

-

-

... More
60 Deg Horizontal Bend, 600 Rad, 150 W, Cover

20

-

-

... More
60 Deg Horizontal Bend, 600 Rad, 300 W, Cover

20

-

-

... More
60 Deg Horizontal Bend, 900 Rad, 600 W, Cover

20

-

-

... More
60 Deg Horizontal Bend, 900 Rad, 750 W, Cover

20

-

-

... More
60 Deg Horizontal Bend, 1200 Rad, 600 W, Cover

50

-

-

... More
90 DEGREE HORIZONTAL ELBOW- HDGI

-

-

-

... More
90 Deg Horizontal Bend, Ladder, 300mm Radius, 150(W) X 100(H) mm

20

-

-

... More
90 Deg Horizontal Bend, Ladder, 600mm Radius, 150(W) X 100(H) mm

20

-

-

... More
90 Deg Horizontal Bend, Ladder, 600mm Radius, 300(W) X 100(H) mm

50

-

-

... More
90 Deg Horizontal Bend, Ladder, 900mm Radius, 300(W) X 100(H) mm

20

-

-

... More
90 Deg Horizontal Bend, Ladder, 600mm Radius, 600(W) X 100(H) mm

50

-

-

... More
90 Deg Horizontal Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

200

-

-

... More
90 Deg Horizontal Bend, Ladder, 900mm Radius, 750(W) X 100(H) mm

20

-

-

... More
90 Deg Horizontal Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

1700

-

-

... More
90 Deg Horizontal Bend, Ladder, 1200mm Radius, 750(W) X 100(H) mm

100

-

-

... More
90 Deg Horizontal Bend, 300 Rad, 150 W, Cover

20

-

-

... More
90 Deg Horizontal Bend, 600 Rad, 150 W, Cover

20

-

-

... More
90 Deg Horizontal Bend, 600 Rad, 300 W, Cover

40

-

-

... More
90 Deg Horizontal Bend, 600 Rad, 600 W, Cover

40

-

-

... More
90 Deg Horizontal Bend, 900 Rad, 300 W, Cover

20

-

-

... More
90 Deg Horizontal Bend, 900 Rad, 600 W, Cover

150

-

-

... More
90 Deg Horizontal Bend, 900 Rad, 750 W, Cover

20

-

-

... More
90 Deg Horizontal Bend, 1200 Rad, 600 W, Cover

1000

-

-

... More
90 Deg Horizontal Bend, 1200 Rad, 750 W, Cover

40

-

-

... More
HORIZONTAL EQUAL TEE- HDGI

-

-

-

... More
Horizontal Tee, Ladder, 300mm Radius, 300(W) X 100(H) mm - 300-300-300mm

20

-

-

... More
Horizontal Tee, Ladder, 900mm Radius, 600(W) X 100(H) mm - 600-600-600mm

40

-

-

... More
Horizontal Tee, Ladder, 1200mm Radius, 600(W) X 100(H) mm - 600-600-600mm

350

-

-

... More
Horizontal Tee, Ladder, 1200mm Radius, 750(W) X 100(H) mm - 750-750-750mm

100

-

-

... More
Horizontal Tee, 600 Radius, 300 W, Cover

20

-

-

... More
Horizontal Tee, 900 Radius, 600 W, Cover

50

-

-

... More
Horizontal Tee, 1200 Radius, 600 W, Cover

200

-

-

... More
Horizontal Tee, 1200 Radius, 750 W, Cover

50

-

-

... More
HORIZONTAL CROSS- HDGI

-

-

-

... More
Horizontal Cross, Ladder, 1200mm Radius, 600(W) X 100(H) mm

250

-

-

... More
Horizontal Cross, Ladder, 1200mm Radius, 750(W) X 100(H) mm

75

-

-

... More
Horizontal Cross, 1200 Radius, 600 W, Cover

150

-

-

... More
Horizontal Cross, 1200 Radius, 750 W, Cover

50

-

-

... More
30 DEGREE INSIDE VERTICAL ELBOW- HDGI

-

-

-

... More
30 Deg Vertical Inside Bend, Ladder, 300mm Radius, 300(W) X 100(H) mm

20

-

-

... More
30 Deg Vertical Inside Bend, Ladder, 600mm Radius, 150(W) X 100(H) mm

20

-

-

... More
30 Deg Vertical Inside Bend, Ladder, 300mm Radius, 600(W) X 100(H) mm

50

-

-

... More
30 Deg Vertical Inside Bend, Ladder, 600mm Radius, 600(W) X 100(H) mm

20

-

-

... More
30 Deg Vertical Inside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

120

-

-

... More
30 Deg Vertical Inside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

200

-

-

... More
30 Deg Vertical Inside Bend, Ladder, 1200mm Radius, 750(W) X 100(H) mm

20

-

-

... More
30 Deg Vertical Inside Bend, 300 Rad, 300 W, Cover

20

-

-

... More
30 Deg Vertical Inside Bend, 300 Rad, 600 W, Cover

20

-

-

... More
30 Deg Vertical Inside Bend, 600 Rad, 150 W, Cover

20

-

-

... More
30 Deg Vertical Inside Bend, 600 Rad, 600 W, Cover

20

-

-

... More
30 Deg Vertical Inside Bend, 900 Rad, 600 W, Cover

60

-

-

... More
30 Deg Vertical Inside Bend, 1200 Rad, 600 W, Cover

150

-

-

... More
30 Deg Vertical Inside Bend, 1200 Rad, 750 W, Cover

20

-

-

... More
45 DEGREE INSIDE VERTICAL ELBOW- HDGI

-

-

-

... More
45 Deg Vertical Inside Bend, Ladder, 300mm Radius, 150(W) X 100(H) mm

20

-

-

... More
45 Deg Vertical Inside Bend, Ladder, 600mm Radius, 600(W) X 100(H) mm

20

-

-

... More
45 Deg Vertical Inside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

75

-

-

... More
45 Deg Vertical Inside Bend, Ladder, 1200mm Radius, 300(W) X 100(H) mm

20

-

-

... More
45 Deg Vertical Inside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

750

-

-

... More
45 Deg Vertical Inside Bend, Ladder, 1200mm Radius, 750(W) X 100(H) mm

150

-

-

... More
45 Deg Vertical Inside Bend, 300 Rad, 150 W, Cover

20

-

-

... More
45 Deg Vertical Inside Bend, 600 Rad, 600 W, Cover

20

-

-

... More
45 Deg Vertical Inside Bend, 900 Rad, 600 W, Cover

40

-

-

... More
45 Deg Vertical Inside Bend, 1200 Rad, 300 W, Cover

20

-

-

... More
45 Deg Vertical Inside Bend, 1200 Rad, 600 W, Cover

400

-

-

... More
45 Deg Vertical Inside Bend, 1200 Rad, 750 W, Cover

60

-

-

... More
60 DEGREE INSIDE VERTICAL ELBOW- HDGI

-

-

-

... More
60 Deg Vertical Inside Bend, Ladder, 600mm Radius, 300(W) X 100(H) mm

20

-

-

... More
60 Deg Vertical Inside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

20

-

-

... More
60 Deg Vertical Inside Bend, Ladder, 900mm Radius, 750(W) X 100(H) mm

20

-

-

... More
60 Deg Vertical Inside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

150

-

-

... More
60 Deg Vertical Inside Bend, Ladder, 1200mm Radius, 750(W) X 100(H) mm

20

-

-

... More
60 Deg Vertical Inside Bend, 600 Rad, 300 W, Cover

20

-

-

... More
60 Deg Vertical Inside Bend, 900 Rad, 600 W, Cover

20

-

-

... More
60 Deg Vertical Inside Bend, 900 Rad, 750 W, Cover

20

-

-

... More
60 Deg Vertical Inside Bend, 1200 Rad, 600 W, Cover

100

-

-

... More
60 Deg Vertical Inside Bend, 1200 Rad, 750 W, Cover

20

-

-

... More
90 DEGREE INSIDE VERTICAL ELBOW- HDGI

-

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 300mm Radius, 150(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 300mm Radius, 300(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 300mm Radius, 600(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 600mm Radius, 150(W) X 100(H) mm

25

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 600mm Radius, 300(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 600mm Radius, 600(W) X 100(H) mm

70

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 900mm Radius, 300(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

350

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

1750

-

-

... More
90 Deg Vertical Inside Bend, 300 Rad, 150 W, Cover

20

-

-

... More
90 Deg Vertical Inside Bend, 300 Rad, 300 W, Cover

20

-

-

... More
90 Deg Vertical Inside Bend, 300 Rad, 600 W, Cover

20

-

-

... More
90 Deg Vertical Inside Bend, 600 Rad, 150 W, Cover

20

-

-

... More
90 Deg Vertical Inside Bend, 600 Rad, 300 W, Cover

20

-

-

... More
90 Deg Vertical Inside Bend, 600 Rad, 600 W, Cover

40

-

-

... More
90 Deg Vertical Inside Bend, 900 Rad, 300 W, Cover

20

-

-

... More
90 Deg Vertical Inside Bend, 900 Rad, 600 W, Cover

200

-

-

... More
90 Deg Vertical Inside Bend, 1200 Rad, 600 W, Cover

1000

-

-

... More
30 DEGREE OUTSIDE VERTICAL ELBOW- HDGI

-

-

-

... More
30 Deg Vertical Outside Bend, Ladder, 300mm Radius, 600(W) X 100(H) mm

50

-

-

... More
30 Deg Vertical Outside Bend, Ladder, 600mm Radius, 150(W) X 100(H) mm

20

-

-

... More
30 Deg Vertical Outside Bend, Ladder, 600mm Radius, 300(W) X 100(H) mm

20

-

-

... More
30 Deg Vertical Outside Bend, Ladder, 600mm Radius, 600(W) X 100(H) mm

20

-

-

... More
30 Deg Vertical Outside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

120

-

-

... More
30 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

220

-

-

... More
30 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 750(W) X 100(H) mm

20

-

-

... More
30 Deg Vertical Outside Bend, 300 Rad, 600 W, Cover

40

-

-

... More
30 Deg Vertical Outside Bend, 600 Rad, 150 W, Cover

20

-

-

... More
30 Deg Vertical Outside Bend, 600 Rad, 300 W, Cover

20

-

-

... More
30 Deg Vertical Outside Bend, 600 Rad, 600 W, Cover

20

-

-

... More
30 Deg Vertical Outside Bend, 900 Rad, 600 W, Cover

60

-

-

... More
30 Deg Vertical Outside Bend, 1200 Rad, 600 W, Cover

150

-

-

... More
30 Deg Vertical Outside Bend, 1200 Rad, 750 W, Cover

20

-

-

... More
45 DEGREE OUTSIDE VERTICAL ELBOW- HDGI

-

-

-

... More
45 Deg Vertical Outside Bend, Ladder, 300mm Radius, 150(W) X 100(H) mm

20

-

-

... More
45 Deg Vertical Outside Bend, Ladder, 300mm Radius, 600(W) X 100(H) mm

20

-

-

... More
45 Deg Vertical Outside Bend, Ladder, 600mm Radius, 600(W) X 100(H) mm

20

-

-

... More
45 Deg Vertical Outside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

75

-

-

... More
45 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 300(W) X 100(H) mm

20

-

-

... More
45 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

600

-

-

... More
45 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 750(W) X 100(H) mm

150

-

-

... More
45 Deg Vertical Outside Bend, 300 Rad, 150 W, Cover

20

-

-

... More
45 Deg Vertical Outside Bend, 300 Rad, 600 W, Cover

20

-

-

... More
45 Deg Vertical Outside Bend, 600 Rad, 600 W, Cover

20

-

-

... More
45 Deg Vertical Outside Bend, 900 Rad, 600 W, Cover

40

-

-

... More
45 Deg Vertical Outside Bend, 1200 Rad, 300 W, Cover

20

-

-

... More
45 Deg Vertical Outside Bend, 1200 Rad, 600 W, Cover

350

-

-

... More
45 Deg Vertical Outside Bend, 1200 Rad, 750 W, Cover

80

-

-

... More
60 DEGREE OUTSIDE VERTICAL ELBOW- HDGI

-

-

-

... More
60 Deg Vertical Outside Bend, Ladder, 600mm Radius, 300(W) X 100(H) mm

20

-

-

... More
60 Deg Vertical Outside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

20

-

-

... More
60 Deg Vertical Outside Bend, Ladder, 900mm Radius, 750(W) X 100(H) mm

40

-

-

... More
60 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

130

-

-

... More
60 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 750(W) X 100(H) mm

20

-

-

... More
60 Deg Vertical Outside Bend, 600 Rad, 300 W, Cover

20

-

-

... More
60 Deg Vertical Outside Bend, 900 Rad, 600 W, Cover

20

-

-

... More
60 Deg Vertical Outside Bend, 900 Rad, 750 W, Cover

20

-

-

... More
60 Deg Vertical Outside Bend, 1200 Rad, 600 W, Cover

100

-

-

... More
60 Deg Vertical Outside Bend, 1200 Rad, 750 W, Cover

20

-

-

... More
90 DEGREE OUTSIDE VERTICAL ELBOW- HDGI

-

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 300mm Radius, 150(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 300mm Radius, 300(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 300mm Radius, 600(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 600mm Radius, 150(W) X 100(H) mm

40

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 600mm Radius, 300(W) X 100(H) mm

80

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 600mm Radius, 600(W) X 100(H) mm

80

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 900mm Radius, 300(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

350

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

2000

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 750(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Outside Bend, 300 Rad, 150 W, Cover

20

-

-

... More
90 Deg Vertical Outside Bend, 300 Rad, 300 W, Cover

20

-

-

... More
90 Deg Vertical Outside Bend, 300 Rad, 600 W, Cover

20

-

-

... More
90 Deg Vertical Outside Bend, 600 Rad, 150 W, Cover

20

-

-

... More
90 Deg Vertical Outside Bend, 600 Rad, 300 W, Cover

40

-

-

... More
90 Deg Vertical Outside Bend, 600 Rad, 600 W, Cover

40

-

-

... More
90 Deg Vertical Outside Bend, 900 Rad, 300 W, Cover

20

-

-

... More
90 Deg Vertical Outside Bend, 900 Rad, 600 W, Cover

250

-

-

... More
90 Deg Vertical Outside Bend, 1200 Rad, 600 W, Cover

1000

-

-

... More
90 Deg Vertical Outside Bend, 1200 Rad, 750 W, Cover

20

-

-

... More
ADJUSTABLE BENDS- HDGI

-

-

-

... More
Vertical Bends (in pair) for 750mm tray

500

-

-

... More
Horizontal Bends (in pair) for 750mm tray

500

-

-

... More
Vertical Bends (in pair) for 600mm tray

750

-

-

... More
Horizontal Bends (in pair) for 600mm tray

750

-

-

... More
Vertical Bends (in pair) for 300mm tray

300

-

-

... More
Horizontal Bends (in pair) for 300mm tray

300

-

-

... More
Vertical Bends (in pair) for 150mm tray

250

-

-

... More
Horizontal Bends (in pair) for 150mm tray

250

-

-

... More
REDUCERS- HDGI

-

-

-

... More
750mm - 300mm Right Hand Reducer including cover

75

-

-

... More
750mm - 300mm Left Hand Reducer including cover

75

-

-

... More
750mm - 300mm Centre Reducer including cover

75

-

-

... More
600mm - 300mm Right Hand Reducer including cover

100

-

-

... More
600mm - 300mm Left Hand Reducer including cover

100

-

-

... More
600mm - 300mm Centre Reducer including cover

100

-

-

... More
300mm - 150mm Right Hand Reducer including cover

75

-

-

... More
300mm - 150mm Left Hand Reducer including cover

75

-

-

... More
300mm - 150mm Centre Reducer including cover

75

-

-

... More
CABLE TRAY SEPERATOR- HDGI

-

-

-

... More
100mm Height Seperator

4000

-

-

... More
SUPPLY & INSTALLATION OF CONDUITS (For Electrical Cabling)

-

-

-

... More
Supply & Laying of following sizes of G.I (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, including supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. NOTE: Selection of correct size of conduit as per cable data provided during detail engineering is contractor's responsiblity. Any incorrect selection of conduit shall be replaced by contractor at no cost and time implication to purchaser. Also the exact quantity of conduit requirement shall be worked out by contractor only.

-

-

-

... More
GI Conduit of size 1"

4000

-

-

... More
GI Conduit of size 1-1/2"

300

-

-

... More
GI Conduit of size 2"

200

-

-

... More
GI Conduit of size 4"

100

-

-

... More
GI Conduit of size 6"

100

-

-

... More
HDPE conduit of size 2" for laying FO cable

30000

-

-

... More
SUPPLY OF MANDATORY SPARE FOR CONDUITS

-

-

-

... More
GI Conduit of size 1"

300

-

-

... More
GI Conduit of size 1-1/2"

100

-

-

... More
GI Conduit of size 2"

100

-

-

... More
HDPE conduit of size 2" for laying FO cable

300

-

-

... More
LIGHTING SYSTEM- SUPPLY , INSTALLATION, TESTING AND COMMISSIONING

-

-

-

... More
LIGHTING FIXTURES- INDUSTRIAL TYPE (SAFE AREA): Supply,Installation, testing and commissioning of following lighting fixtures complete with lamps, with loop in-loop out connection with min.cable size of 2.5/4/6 sq.mm Cu cable, necessary control gear,constant current driver and electronic components in pre wired condition with all accessories along with supply of cable glands with selected cable gland entry, lugs as per approved drawings, data sheet for lighting fixture schedule, installation standards, specification NR-0ZZZZ-EL-SPE-0023 of this tender. This includes cable termination and connection, fixing of cable glands, lugs for different type of installation( Ceiling /Wall / bracket or pole mounting ,etc. and other accessories.including supply of all necessary hardware and consumables required for the complete installation as per specifications of this tender,installation standards TP-1ZZZA-EL-STC-0002 and TP-1ZZZA-EL-STC-0003 and directions of Engineer-in-Charge. This shall include transportation from storage area to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly of luminaries, drilling etc. as required, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications required to be carried out on the mounting bracket to suit mounting of lighting fixtures & any other modifications, if required, for proper commissioning of fixtures. No separate cost is envisaged for control gear box of lighting fixtures, same shall be included in this item only. Paint shade shall be as below :Grey (for Normal lighting)-RAL 7035; Yellow (for Emergency lighting)-RAL 1012; Red (for critical lighting)-RAL-3573

-

-

-

... More
150W LED Flood light fixture, 240VAC, 50Hz, Outdoor industrial type, Handrail / Pole mounting, IP56(min) Paint shade: Grey (for Normal lighting)

32

-

-

... More
150W LED Flood light fixture, 240VAC, 50Hz, Outdoor industrial type, Handrail / Pole mounting, IP56(min) Paint shade: Yellow (for Emergency lighting)

14

-

-

... More
150W LED Flood Light Fixture, 240VAC, 50Hz, Outdoor industrial type, Bracket mounted, IP56(min) Paint shade: Grey (for Normal lighting)

25

-

-

... More
150W LED Flood Light Fixture, 240VAC, 50Hz, Outdoor industrial type, Bracket mounted, IP56(min) Paint shade: Yellow (for Emergency lighting)

21

-

-

... More
2 x 20W, 240VAC, 50Hz, Industrial, Indoor, LED tubular type surface or suspended mounting type IP56 (Min.) Paint shade: Grey (for Normal lighting)

69

-

-

... More
2 x 20W, 240VAC, 50Hz, Industrial, Indoor, LED tubular type surface or suspended mounting type IP56 (Min.) Paint shade: Yellow (for Emergency lighting)

23

-

-

... More
45W LED Lamp, 240VAC, 50Hz, Industrial, Outdoor, Wellglass, Handrail / Pole mounting, IP56(min.) Paint shade: Grey (for Normal lighting)

287

-

-

... More
45W LED Lamp, 240VAC, 50Hz, Industrial, Outdoor, Wellglass, Handrail / Pole mounting, IP56(min.) Paint shade: Yellow (for Emergency lighting)

100

-

-

... More
45W LED Lamp, 240VAC, 50Hz, Outdoor industrial type, Wellglass, Bracket mounted, IP56(min) Paint shade: Grey (for Normal lighting)

264

-

-

... More
45W LED Lamp, 240VAC, 50Hz, Outdoor industrial type, Wellglass, Bracket mounted, IP56(min) Paint shade: Yellow (for Emergency lighting)

88

-

-

... More
90W LED Lamp, 240VAC, 50Hz, Industrial, Outdoor, Medium bay, surface or pendent mounting type, IP56(min.) Paint shade: Grey (for Normal lighting)

31

-

-

... More
90W LED Lamp, 240VAC, 50Hz, Industrial, Outdoor, Medium bay, surface or pendent mounting type, IP56(min.) Paint shade: Yellow (for Emergency lighting)

11

-

-

... More
120W LED street light fixture, 240VAC, 50Hz, Outdoor industrial type, Pole mounting, IP56(min)

43

-

-

... More
18W LED Fixture suitable for 110V DC , Industrial, outdoor, complete with driver,surface mounted , IP56(min) Paint shade: Red (for critical lighting)

21

-

-

... More
Colour coded stickers for lighting fixture and JB service identification; - Grey (for Normal lighting)

2206

-

-

... More
Colour coded stickers for lighting fixture and JB service identification; - Yellow (for Emergency lighting)

736

-

-

... More
Colour coded stickers for lighting fixture and JB service identification; - Red (for critical lighting)

962

-

-

... More
SUPPLY OF MANDATORY SPARE FOR LIGHTING FIXTURES- INDUSTRIAL TYPE (SAFE AREA)

-

-

-

... More
150W LED Flood light fixture, 240VAC, 50Hz, Outdoor industrial type,Handrail / Pole mounting/Bracket mounted, IP56(min) Paint shade: Grey -10Nos., Yellow -10Nos.

20

-

-

... More
2 x 20W, 240VAC, 50Hz, Industrial, Indoor, LED tubular type surface or suspended mounting type IP56 (Min.) Paint shade: Grey -15Nos., Yellow -10Nos.

25

-

-

... More
45W LED Lamp, 240VAC, 50Hz, Industrial, Outdoor, Wellglass, Handrail / Pole mounting/ Bracket mounted, IP56(min.) Paint shade: Grey -60Nos., Yellow -40Nos.

100

-

-

... More
90W LED Lamp, 240VAC, 50Hz, Industrial, Outdoor, Medium bay, surface or pendent mounting type, IP56(min.) Paint shade: Grey -10Nos., Yellow -10Nos.

20

-

-

... More
120W LED street light fixture, 240VAC, 50Hz, Outdoor industrial type, Pole mounting, IP56(min)

15

-

-

... More
18W LED Fixture suitable for 110V DC , Industrial, outdoor, complete with driver,surface mounted , IP56(min) Paint shade: Red (for critical lighting)

10

-

-

... More
Supply of Mandatary spares for Light fixtures as per section-H-1.1-TP-1ZZZA-PQ-PRC-0005_P2-SPARE PARTS, SPECIAL TOOLS AND CONSUMABLES PHILOSOPHY

1

-

-

... More
INDOOR INDUSTRIAL TYPE LIGHTING DISTRIBUTION PANELS: Supply,Installation, testing and commissioning of following Power Panels, Lighting Panels & Critical Lighting Panels including supply of all necessary hardware as per specification TP-1ZZZA-EL-SPE-0011 of this tender. The panels shall be supplied along with requisite number of suitable cable glands with selected cable gland entry required for incoming and outgoing cables and plug for plugging unused entry. This includes cable termination and connection, fixing of cable glands, lugs for different type of installation( Ceiling /Wall / bracket or pole mounting ,etc.) and other accessories, including supply of all necessary hardware and consumables required for the complete installation as per specifications of this tender,installation standards TP-1ZZZA-EL-STC-0002 and TP-1ZZZA-EL-STC-0003 and directions of Engineer-in-Charge. This shall include transportation from storage area to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly , drilling etc. as required, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications if required, for proper commissioning . The cable data will be shared during detail engineering for correct selection of cable gland.The cost of cable glands shall be included and no separate payment for cable gland is envisaged.

-

-

-

... More
Normal Lighting Panel : Wall mounted type, IP-42, Short Ckt Rating 10kA for 1 Sec : 1) Incoming - 415V, 3 phase,63A 4P MCB (type C MCB) 2) Outgoing - (12 Nos): 240V AC, 16A DP MCB with 30mA ELCB (type C MCB) Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx70 Sqmm

1

-

-

... More
Emergency Lighting Panel : Wall mounted type, IP-42, Short Ckt Rating 10kA for 1 Sec : 1) Incoming - 415V, 3 phase,63A 4P MCB (type C MCB) 2) Outgoing - (12 Nos): 240V AC, 16A DP MCB with 30mA ELCB (type C MCB) Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx70 Sqmm

1

-

-

... More
Power Distribution Board : Wall mounted type, IP-42, Short Ckt Rating 10kA for 1 Sec : 1) Incoming - 415V, 3 phase,63A 4P MCB 2) Outgoing - (12 Nos): 240V AC, 20A DP MCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx95 Sqmm

24

-

-

... More
Power Distribution Board : Wall mounted type, IP-42, Short Ckt Rating 10kA for 1 Sec : 1) Incoming - 415V, 3 phase,63A 4P MCB 2) Outgoing - (9 Nos): 240V AC, 20A DP MCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx95 Sqmm

2

-

-

... More
Supply of Mandatary spares for Lighting and Smal power panels as per section-H-1.1-TP-1ZZZA-PQ-PRC-0005_P2-SPARE PARTS, SPECIAL TOOLS AND CONSUMABLES PHILOSOPHY

1

-

-

... More
Power Distribution Board : Wall mounted type, IP-42, Short Ckt Rating 15kA for 1 Sec : 1) Incoming - 415V, 3 phase,400A 4P MCCB 2) Outgoing - (3 Nos): 240V AC, 125A DP MCB Outgoing Cable Size - 3C x 50 Sqmm Incoming Cable Size - 4Cx150 Sqmm

3

-

-

... More
Power Distribution Board : Wall mounted type, IP-42, Short Ckt Rating 10kA for 1 Sec : 1) Incoming - 415V, 3 phase,200A 4P MCCB 2) Outgoing - (3 Nos): 240V AC, 63A DP MCB Outgoing Cable Size - 3C x 25 Sqmm Incoming Cable Size - 4Cx150 Sqmm

1

-

-

... More
Power Distribution Board : Wall mounted type, IP-42, Short Ckt Rating 10kA for 1 Sec : 1) Incoming - 415V, 3 phase,100A 4P MCCB 2) Outgoing - (3 Nos): 240V AC, 25A DP MCB Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx150 Sqmm

1

-

-

... More
Power Distribution Board : Wall mounted type, IP-42, Short Ckt Rating 10kA for 1 Sec : 1) Incoming - 415V, 3 phase,125A 4P MCCB 2) Outgoing - (3 Nos): 240V AC, 40A DP MCB Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx150 Sqmm

1

-

-

... More
OUTDOOR INDUSTRIAL TYPE DISTRIBUTION PANEL: Supply,Installation, testing and commissioning of following Power Panels, Lighting Panels & Critical Lighting Panels including supply of all necessary hardware as per specification TP-1ZZZA-EL-SPE-0011 of this tender. The panels shall be supplied along with requisite number of suitable cable glands with selected cable gland entry required for incoming and outgoing cables and plug for plugging unused entry. This includes cable termination and connection, fixing of cable glands, lugs for different type of installation( Ceiling /Wall / bracket or pole mounting ,etc.) and other accessories, including supply of all necessary hardware and consumables required for the complete installation as per specifications of this tender,installation standards TP-1ZZZA-EL-STC-0002 and TP-1ZZZA-EL-STC-0003 and directions of Engineer-in-Charge. This shall include transportation from storage area to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly , drilling etc. as required, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications if required, for proper commissioning . The cable data will be shared during detail engineering for correct selection of cable gland.The cost of cable glands shall be included and no separate payment for cable gland is envisaged.

-

-

-

... More
Normal Lighting Panel : Column mounted type, weather proof type, Min. IP-56 with canopy, Short Ckt Rating 10kA for 1 Sec 1) Incoming - 415V, 3 phase,63A 4P MCB 2) Outgoing - (12 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx95 Sqmm

10

-

-

... More
Normal Lighting Panel : Column mounted type, weather proof type, Min. IP-56 with canopy, Short Ckt Rating 10kA for 1 Sec 1) Incoming - 415V, 3 phase,63A 4P MCB 2) Outgoing - (12 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx300Sqmm

9

-

-

... More
Normal Lighting Panel : Column mounted type, weather proof type, Min. IP-56 with canopy, Short Ckt Rating 10kA for 1 Sec 1) Incoming - 415V, 3 phase,63A 4P MCB 2) Outgoing - (6 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size - 4Cx95 Sqmm

1

-

-

... More
Emergency Lighting Panel : Coloumn mounted type, weather proof type, Min. IP-56 with canopy, Short Ckt Rating 10kA for 1 Sec 1) Incoming - 415V, 3 phase,63A 4P MCB 2) Outgoing - (9 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx95 Sqmm

11

-

-

... More
Emergency Lighting Panel : Coloumn mounted type, weather proof type, Min. IP-56 with canopy, Short Ckt Rating 10kA for 1 Sec 1) Incoming - 415V, 3 phase,63A 4P MCB 2) Outgoing - (9 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx300Sqmm

6

-

-

... More
Emergency Lighting Panel : Coloumn mounted type, weather proof type, Min. IP-56 with canopy, Short Ckt Rating 10kA for 1 Sec 1) Incoming - 415V, 3 phase,63A 4P MCB 2) Outgoing - (6 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx95 Sqmm

1

-

-

... More
DC Critical Lighting Panel : Coloumn mounted type,, weather proof type, Min. IP-56 with canopy, Short Ckt Rating 10kA for 1 Sec 1) Incoming - 110V DC, 63A, 2P MCB 2) Outgoing - 12 Nos: 110V DC, 10A DP MCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size - 2Cx95 Sqmm

4

-

-

... More
SUPPLY OF MANDATORY SPARE FOR OUTDOOR INDUSTRIAL TYPE DISTRIBUTION PANEL

-

-

-

... More
Lighting Panel : Column mounted type, weather proof type, Min. IP-56 with canopy, Short Ckt Rating 10kA for 1 Sec 1) Incoming - 415V, 3 phase,63A 4P MCB 2) Outgoing - (12 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx95 Sqmm

3

-

-

... More
Lighting Panel : Column mounted type, weather proof type, Min. IP-56 with canopy, Short Ckt Rating 10kA for 1 Sec 1) Incoming - 415V, 3 phase,63A 4P MCB 2) Outgoing - (6 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size -4Cx95 Sqmm

2

-

-

... More
DC Critical Lighting Panel : Coloumn mounted type,, weather proof type, Min. IP-56 with canopy, Short Ckt Rating 10kA for 1 Sec 1) Incoming - 110V DC, 63A, 2P MCB 2) Outgoing - 12 Nos: 110V DC, 10A DP MCB Outgoing Cable Size - 3C x 2.5 / 4 / 6 Sqmm Incoming Cable Size - 2Cx95 Sqmm

2

-

-

... More
Supply of Mandatary spares for Lighting and Smal power panels as per section-H-1.1-TP-1ZZZA-PQ-PRC-0005_P2-SPARE PARTS, SPECIAL TOOLS AND CONSUMABLES PHILOSOPHY

1

-

-

... More
INDUSTRIAL LIGHTING JUNCTION BOX (OUTDOOR): Supply ,Installation, testing and commissioning of following industrial outdoor,suitable for high corrosive areas, weather proof lighting junction boxes with complete accessories as per approved drawings, specification NR-0ZZZZ-EL-SPE-0023 of this tender. The lighting junction box shall be supplied along with suitable cable glands with selected cable gland entry and plug (for plugging unused entry) required for incoming and outgoing cables. The cable data will be shared during detail engineering for correct selection of cable gland.The cost of cable glands shall be included and no separate payment for cable gland is envisaged. This includes cable termination and connection, fixing of cable glands, lugs for different type of installation( Ceiling /Wall / bracket or pole mounting ,etc.) and other accessories.including supply of all necessary hardware and consumables required for the complete installation as per specifications of this tender,installation standards TP-1ZZZA-EL-STC-0002 and TP-1ZZZA-EL-STC-0003 and directions of Engineer-in-Charge. This shall include transportation from storage area to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly of luminaries, drilling etc. as required, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications required to be carried out on the mounting bracket to suit mounting of JBs & any other modifications, if required, for proper commissioning. Paint shade shall be as below :Grey (for Normal lighting)-RAL 7035; Yellow (for Emergency lighting)-RAL 1012; Red (for critical lighting)-RAL-3573

-

-

-

... More
240V AC with 20A X 4 way weather proof Lighting Junction Box with Diecast Aluminium enclosure material, suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade shall be of Grey- Normal Lighting

240

-

-

... More
Junction Box suitable for pole mounted with bottom cable entry, 240V AC with 20A X 4 way weather proof Lighting Junction Box with Diecast Aluminium enclosure material, suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade shall be of Grey- Normal Lighting

555

-

-

... More
240V AC with 20A X 4 way weather proof Lighting Junction Box with Diecast Aluminium enclosure material, suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade shall be of Yellow-Emergency Lighting

85

-

-

... More
Junction Box suitable for pole mounted with bottom cable entry, 240V AC with 20A X 4 way weather proof Lighting Junction Box with Diecast Aluminium enclosure material, suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade shall be of Yellow-Emergency Lighting

175

-

-

... More
240V AC with 20A X 4 way weather proof Lighting Junction Box with Diecast Aluminium enclosure material, junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade shall be of Red- Critical Lighting

12

-

-

... More
240V AC with 20A X 4 way FRP junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade shall be of Grey- Normal Lighting

7

-

-

... More
240V AC with 20A X 4 way FRP junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade shall be of Yellow-Emergency Lighting

4

-

-

... More
240V AC with 20A X 4 way weather proof Lighting Junction Box with Diecast Aluminium enclosure material, suitable for terminating 10 / 16 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade shall be of Grey- Normal Lighting

5

-

-

... More
240V AC with 20A X 4 way weather proof Lighting Junction Box with Diecast Aluminium enclosure material, suitable for terminating 10 / 16 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade shall be of Yellow-Emergency Lighting

5

-

-

... More
240V AC with 20A X 4 way weather proof Lighting Junction Box with Diecast Aluminium enclosure material, suitable for terminating 10 / 16 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade shall be of Red- Critical Lighting

5

-

-

... More
SUPPLY OF MANDATORY SPARE FOR INDUSTRIAL LIGHTING JUNCTION BOX

-

-

-

... More
240V AC with 20A X 4 way weather proof Lighting Junction Box with Diecast Aluminium enclosure material, suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade -Grey- 40Nos. Yellow-30Nos.

70

-

-

... More
240V AC with 20A X 4 way FRP junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. Degree of protection shall be IP-56(min). JB Colour Shade -Grey- 10Nos. Yellow-10Nos.

20

-

-

... More
POWER OUTLET- INDUSTRIAL TYPE: Supply ,Installation, testing and commissioning of following weather proof metal clad industrial type socket and plug with interlocking switch, including supply of double compresion brass nickel plated cable glands with selected cable gland entry, tinned copper lugs, including all accessories as per approved drawings, specification NR-0ZZZZ-EL-SPE-0023 of this tender and directions of Engineer-in-charge. This includes cable termination and connection, fixing of cable glands, lugs for different type of installation( Ceiling /Wall / bracket or pole mounting ,etc.) and other accessories, including supply of all necessary hardware and consumables required for the complete installation as per specifications of this tender,installation standards TP-1ZZZA-EL-STC-0002 and TP-1ZZZA-EL-STC-0003 and directions of Engineer-in-Charge. This shall include transportation from storage area to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly , drilling etc. as required, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications if required, for proper commissioning . The cable data will be shared during detail engineering for correct selection of cable gland.The cost of cable glands shall be included and no separate payment for cable gland is envisaged.

-

-

-

... More
160 Amps, 415 VAC, 5 Pin, industrial socket with plug top with 4 poles MCCB housed in enclosure with canopy. It shall be outdoor, weatherproof type, Min. IP56 and suitable for termination of 4C x 120-240sq.mm . Socket shall have the necessary mechanical interlocks and earthing facilities.

49

-

-

... More
SUPPLY OF MANDATORY SPARE FOR POWER OUTLET- INDUSTRIAL TYPE

-

-

-

... More
160 Amps, 415 VAC, 5 Pin, industrial socket with plug top with 4 poles MCCB housed in enclosure with canopy. It shall be outdoor, weatherproof type, Min. IP56 and suitable for termination of 4C x 120-240sq.mm . Socket shall have the necessary mechanical interlocks and earthing facilities.

10

-

-

... More
LIGHTING FIXTURES- FLAME PROOF: Supply,Installation, testing and commissioning of following lighting fixtures complete with lamps, with loop in-loop out connection with min.cable size of 2.5/4/6 sq.mm Cu cable, with selected cable gland entry, necessary control gear,constant current driver and , electronic components in pre wired condition with all accessories along with supply of cable glands, lugs as per approved drawings, data sheet for lighting fixture schedule, installation standards, specifications NR-0ZZZZ-EL-SPE-0023 of this tender and directions of Engineer-in-Charge. This includes cable termination and connection, fixing of cable glands, lugs for different type of installation( Ceiling /Wall / bracket or pole mounting ,etc. and other accessories.including supply of all necessary hardware and consumables required for the complete installation as per specifications of this tender,installation standards TP-1ZZZA-EL-STC-0002 and TP-1ZZZA-EL-STC-0003 and directions of Engineer-in-Charge. This shall include transportation from storage area to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly of luminaries, drilling etc. as required, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications required to be carried out on the mounting bracket to suit mounting of lighting fixtures & any other modifications, if required, for proper commissioning of fixtures. No separate cost is envisaged for control gear box of lighting fixtures, same shall be included in this item only. Paint shade shall be as below :Grey (for Normal lighting)-RAL 7035; Yellow (for Emergency lighting)-RAL 1012; Red (for critical lighting)-RAL-3573

-

-

-

... More
150 W LED Flood light fixture, 240V, 50Hz AC, Flameproof (Ex d) suitable for hazardous area Zone 1& 2, IIA/IIB/IIC T3, outdoor, IP-65 min, Integral bracket mounted Paint shade: Grey (for Normal lighting)

59

-

-

... More
150 W LED Flood light fixture, 240V, 50Hz AC, Flameproof (Ex d) suitable for hazardous Zone1& 2, IIA/IIB/IIC T3, outdoor, IP-65 min, Integral bracket mounted Paint shade: Yellow (for Emergency lighting)

28

-

-

... More
225 W LED Flood light fixture, 240V, 50Hz AC, Flameproof (Ex d) suitable for hazardous Zone1& 2, IIA/IIB/IIC,T3, outdoor, IP-65 min, Integral bracket mounted Paint shade: Grey (for Normal Lighting)

15

-

-

... More
225 W LED Flood light fixture, 240V, 50Hz AC, Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, Integral bracket mounted Paint shade: Yellow (for Emergency lighting)

10

-

-

... More
90W,LED Wellglass light fixture, 240V, 50Hz AC,Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, surface or pendent mounted Paint shade: Grey (for Normal Lighting)

1

-

-

... More
90W,LED Wellglass light fixture, 240V, 50Hz AC,Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, surface or pendent mounted Paint shade: Yellow (for Emergency Lighting)

1

-

-

... More
45W,LED Wellglass light fixture, 240V, 50Hz AC,Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, handrail/pole mounted Paint shade: Grey (for Normal Lighting)

589

-

-

... More
45W,LED Wellglass light fixture, 240V, 50Hz AC,Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, handrail/pole mounted Paint shade: Yellow (for Emergency lighting)

204

-

-

... More
45W,LED Wellglass light fixture, 240V, 50Hz AC,Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min,bracket mounted Paint shade: Grey (for Normal Lighting)

280

-

-

... More
45W,LED Wellglass light fixture, 240V, 50Hz AC,Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min,bracket mounted Paint shade: Yellow (for Emergency lighting)

96

-

-

... More
45W,LED Wellglass light fixture, 240V, 50Hz AC,Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, ceiling mounted Paint shade: Grey (for Normal Lighting)

118

-

-

... More
45W,LED Wellglass light fixture, 240V, 50Hz AC,Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, ceiling mounted Paint shade: Yellow (for Emergency lighting)

42

-

-

... More
26W,LED Wellglass light fixture, 110V DC, Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, handrail / pole mounted Paint shade: Red (for critical lighting)

31

-

-

... More
26W,LED Wellglass light fixture, 110V DC, Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, bracket mounted. Paint shade: Red (for critical lighting)

19

-

-

... More
26W,LED Wellglass light fixture, 110V DC, Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, ceiling mounted. Paint shade: Red (for critical lighting)

7

-

-

... More
Flame proof (Ex'd'), IIA/IIB/IIC, T3, Double Obstruction Aviation Lighting fixture

2

-

-

... More
240V / 240V AC power converter for aviation lighting with built-in battery back-up suitable for 200W output power and 30 minutes back-up time including all labour and materials, specifications of this tender and directions of Engineer-in-charge. The enclosure of the complete system shall be flame proof type suitable for gas group IIA/IIB/IIC & Temp. T3

2

-

-

... More
300 W LED Flood light fixture, 240V, 50Hz AC, Flameproof (Ex d) suitable for hazardous Zone1& 2, IIA/IIB/IIC,T3, outdoor, IP-65 min, Integral bracket mounted Paint shade: Grey (for Normal Lighting)

81

-

-

... More
300 W LED Flood light fixture, 240V, 50Hz AC, Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, Integral bracket mounted Paint shade: Yellow (for Emergency lighting)

64

-

-

... More
SUPPLY OF MANDATORY SPARE FOR POWER OUTLET- LIGHTING FIXTURES- FLAME PROOF

-

-

-

... More
150 W LED Flood light fixture, 240V, 50Hz AC, Flameproof (Ex d) suitable for hazardous area Zone 1& 2, IIA/IIB/IIC T3, outdoor, IP-65 min, Integral bracket mounted Paint shade: Grey -10Nos. , Yellow-10Nos.

20

-

-

... More
225 W LED Flood light fixture, 240V, 50Hz AC, Flameproof (Ex d) suitable for hazardous Zone1& 2, IIA/IIB/IIC,T3, outdoor, IP-65 min, Integral bracket mounted Paint shade: Grey -10Nos. , Yellow-10Nos.

20

-

-

... More
90W,LED Wellglass light fixture, 240V, 50Hz AC,Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, surface or pendent mounted Paint shade: Grey -10Nos. , Yellow-10Nos.

20

-

-

... More
45W,LED Wellglass light fixture, 240V, 50Hz AC,Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, handrail/pole mounted

180

-

-

... More
26W,LED Wellglass light fixture, 110V DC, Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, handrail / pole mounted

20

-

-

... More
Supply of Mandatary spares for Light fixtures as per section-H-1.1-TP-1ZZZA-PQ-PRC-0005_P2-SPARE PARTS, SPECIAL TOOLS AND CONSUMABLES PHILOSOPHY

1

-

-

... More
300 W LED Flood light fixture, 240V, 50Hz AC, Flameproof (Ex d) suitable for hazardous Zone1& 2, IIA/IIB/IIC,T3, outdoor, IP-65 min, Integral bracket mounted Paint shade: Grey (for Normal Lighting)

20

-

-

... More
300 W LED Flood light fixture, 240V, 50Hz AC, Flameproof (Ex d) suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor, IP-65 min, Integral bracket mounted Paint shade: Yellow (for Emergency lighting)

20

-

-

... More
FLAME PROOF LIGHTING DISTRIBUTION BOARD: Supply,Installation, testing and commissioning of following Power Panels, Lighting Panels & Critical Lighting Panels, Power Distribution boards and Feeder Pillars including supply of all necessary hardware as per specification TP-1ZZZA-EL-SPE-0010 of this tender. The panels shall be supplied along with requisite number of suitable cable glands with selected cable gland entry required for incoming and outgoing cables and plug for plugging unused entry. This includes cable termination and connection, fixing of cable glands, lugs for different type of installation( Ceiling /Wall / bracket or pole mounting ,etc.) and other accessories, including supply of all necessary hardware and consumables required for the complete installation as per specifications of this tender,installation standards TP-1ZZZA-EL-STC-0002 and TP-1ZZZA-EL-STC-0003 and directions of Engineer-in-Charge. This shall include transportation from storage area to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly , drilling etc. as required, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications if required, for proper commissioning . The cable data will be shared during detail engineering for correct selection of cable gland.The cost of cable glands shall be included and no separate payment for cable gland is envisaged.

-

-

-

... More
Normal Lighting Panel : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415V, 3 phase,63A 4P MCB (type C MCB) 2) Outgoing - (12 Nos): 240V AC, 16A DP MCB with 30mA ELCB (type C MCB) Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx95 Sqmm

26

-

-

... More
Normal Lighting Panel : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415V, 3 phase,63A 4P MCB (type C MCB) 2) Outgoing - (12 Nos): 240V AC, 16A DP MCB with 30mA ELCB (type C MCB) Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx(120- 300)Sqmm

9

-

-

... More
Normal Lighting Panel : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415V, 3 phase,63A 4P MCB (type C MCB) 2) Outgoing - (6 Nos): 240V AC, 16A DP MCB with 30mA ELCB (type C MCB) Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx95 Sqmm

10

-

-

... More
Emergency Lighting Distribuation Board : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415V, 3 phase,63A 4P MCB (type C MCB) 2) Outgoing - (9 Nos): 240V AC, 16A DP MCB with 30mA ELCB (type C MCB) Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx95 Sqmm

14

-

-

... More
Emergency Lighting Distribuation Board : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415V, 3 phase,63A 4P MCB (type C MCB) 2) Outgoing - (9 Nos): 240V AC, 16A DP MCB with 30mA ELCB (type C MCB) Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx(120- 300)Sqmm

4

-

-

... More
Emergency Lighting Distribuation Board : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415V, 3 phase,63A 4P MCB (type C MCB) 2) Outgoing - (6 Nos): 240V AC, 16A DP MCB with 30mA ELCB (type C MCB) Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx95 Sqmm

11

-

-

... More
Critical Lighting Distribuation Board : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 110V DC, 25A, DP MCB (type C MCB) 2) Outgoing - 9 Nos: 110V DC, 10A DP MCB (type C MCB) Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx95 Sqmm

5

-

-

... More
SUPPLY OF MANDATORY SPARE FOR FLAME PROOF LIGHTING DISTRIBUATION BOARD

-

-

-

... More
Lighting Panel : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415V, 3 phase,63A 4P MCB (type C MCB) 2) Outgoing - (12 Nos): 240V AC, 16A DP MCB with 30mA ELCB (type C MCB) Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx95 Sqmm

5

-

-

... More
Critical Lighting Distribuation Board : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 110V DC, 25A, DP MCB (type C MCB) 2) Outgoing - 9 Nos: 110V DC, 10A DP MCB (type C MCB) Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx95 Sqmm

2

-

-

... More
Supply of Mandatary spares for Lighting and Smal power panels as per section-H-1.1-TP-1ZZZA-PQ-PRC-0005_P2-SPARE PARTS, SPECIAL TOOLS AND CONSUMABLES PHILOSOPHY

1

-

-

... More
POWER DISTRIBUTION BOARD FLAME PROOF

-

-

-

... More
Power Receptacle Power DB : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415V, 3 phase, 63A 4P MCB 2) Outgoing - (9 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx95 Sqmm

2

-

-

... More
Power Receptacle Power DB : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415V, 3 phase, 63A 4P MCB 2) Outgoing - (6 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx95 Sqmm

1

-

-

... More
MOV Power Distribuation Board : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415VAC, 25A, TP MCCB 2) Outgoing - 16 Nos: 415VAC, 1.6-2.5A TP MCB Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 3Cx120 Sqmm

7

-

-

... More
Feeder pillars with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, Outdoor installation. Feeder pillars should be Modular / combinable, Floor Mounting according to IEC 60529.All MCCBs with O/C, S/C, E/F release (Microprocessor Based) and shunt trip for earth leakage protection.Short Ckt Rating 25kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010 1) Incoming - 415VAC, 400A, 4P MCCB 2) Outgoing - 415v, 2 Nos. 250A 4P MCCB, 1 No. 125A 4P MCCB, 1 No. 63A 4P MCCB outgoing feeders

2

-

-

... More
SUPPLY OF MANDATORY SPARE FOR POWER DISTRIBUATION BOARD FLAME PROOF

-

-

-

... More
Power Receptacle Power DB : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415V, 3 phase, 63A 4P MCB 2) Outgoing - (9 Nos): 240V AC, 16A DP MCB with 30mA ELCB Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 4Cx95 Sqmm

4

-

-

... More
MOV Power Distribuation Board : Column mounted type with canopy , Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC T3, outdoor,Short Ckt Rating 10kA for 1 Sec, as per approved drawing and specification TP-1ZZZA-EL-SPE-0010. 1) Incoming - 415VAC, 25A, TP MCCB 2) Outgoing - 16 Nos: 415VAC, 1.6-2.5A TP MCB Outgoing Cable Size - 3C x 16 Sqmm Incoming Cable Size - 3Cx120 Sqmm

2

-

-

... More
Supply of Mandatary spares for Lighting and Smal power panels as per section-H-1.1-TP-1ZZZA-PQ-PRC-0005_P2-SPARE PARTS, SPECIAL TOOLS AND CONSUMABLES PHILOSOPHY

1

-

-

... More
LIGHTNG AND SMALL POWER JUNCTION BOX- FLAME PROOF: Supply,Installation, testing and commissioning of industrial outdoor, Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, lighting/power junction boxes with complete accessories as per approved drawings, specification NR-0ZZZZ-EL-SPE-0023 of this tender. The lighting/power junction box shall be supplied along with suitable cable glands and plug (for plugging unused entry) required for incoming and outgoing cables. The cable data will be shared during detail engineering for correct selection of cable gland.The cost of cable glands shall be included and no separate payment for cable gland is envisaged. Paint shade shall be as below :Grey (for Normal lighting)-RAL 7035; Yellow (for Emergency lighting)-RAL 1012; Red (for critical lighting)-RAL-3573

-

-

-

... More
LIGHTNG JUNCTION BOX- FLAME PROOF

-

-

-

... More
240V AC with 20A X 4 way junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. JB Colour Shade shall be of Grey- Normal Lighting

155

-

-

... More
240V AC with 20A X 4 way junction box suitable for terminating 10/16 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. JB Colour Shade shall be of Grey- Normal Lighting

20

-

-

... More
Junction Box suitable for pole mounted with bottom cable entry, 240V AC with 20A X 4 way junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. JB Colour Shade shall be of Grey- Normal Lighting

650

-

-

... More
240V AC with 20A X 4 way junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. JB Colour Shade shall be of Yellow-Emergency Lighting

60

-

-

... More
240V AC with 20A X 4 way junction box suitable for terminating 10/16 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. JB Colour Shade shall be of Yellow-Emergency Lighting

10

-

-

... More
Junction Box suitable for pole mounted with bottom cable entry, 240V AC with 20A X 4 way junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. JB Colour Shade shall be of Yellow-Emergency Lighting

240

-

-

... More
240V AC with 20A X 4 way junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes. JB Colour Shade shall be of Red- Critical Lighting

31

-

-

... More
240V AC with 20A X 4 way junction box suitable for terminating 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes.

10

-

-

... More
SUPPLY OF MANDATORY SPARE FOR LIGHTNG JUNCTION BOX- FLAME PROOF

-

-

-

... More
240V AC with 20A X 4 way junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes.

75

-

-

... More
240V AC with 20A X 4 way junction box suitable for terminating 10/16 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes.

30

-

-

... More
Junction Box suitable for pole mounted with bottom cable entry, 240V AC with 20A X 4 way junction box suitable for terminating 2.5 / 4 / 6 SQ.MM. Copper armoured and With 4 Nos of cable entry. 3 Nos of Double compression heavy duty Cable glands shall be provided & 1No. of Blanking plug & PVC shrouds shall be provided for given cable sizes.

50

-

-

... More
POWER JUNCTION BOX- FLAME PROOF: Supply,Installation, testing and commissioning of industrial outdoor, Flame proof (Exd), IP-65, suitable for hazardous Zone 1 & 2 IIA/IIB/IIC, T3, power junction boxes with terminals suitable for 415V AC, complete accessories as per approved drawings, specification NR-0ZZZZ-EL-SPE-0023 of this tender. The power junction box shall be supplied along with suitable cable glands and plug (for plugging unused entry) required for incoming and outgoing cables. The cable data will be shared during detail engineering for correct selection of cable gland.The cost of cable glands shall be included and no separate payment for cable gland is envisaged.

-

-

-

... More
Type-1 : Power Junction Box . INCOMING CABLE SIZE: 2 RUNS OF 3C x 300 SQ.MM OUTGOING CABLE SIZE: 2 RUNS OF 3C x 120 SQ.MM Mounting : wall / concrete / steel structure

10

-

-

... More
Type-2 : Power Junction Box . INCOMING CABLE SIZE: 2 RUNS OF 3C X 300 SQ.MM OUTGOING CABLE SIZE: 2 RUNS OF 3C X 50 SQ.MM Mounting : wall / concrete / steel structure

12

-

-

... More
Type-3 : Power Junction Box . INCOMING CABLE SIZE: 3 RUNS OF 3Cx300 SQ.MM OUTGOING CABLE SIZE: 2 RUNS OF 3Cx120 SQ.MM Mounting : wall / concrete / steel structure

11

-

-

... More
Type-4 : Power Junction Box . INCOMING CABLE SIZE: 5 RUNS OF 3C X 300 SQ.MM OUTGOING CABLE SIZE: 1 RUN OF 3C X 240 SQ.MM Mounting : wall / concrete / steel structure

10

-

-

... More
Type-5 : Power Junction Box . INCOMING CABLE SIZE: 7 RUNS OF 3C X 300 SQ.MM OUTGOING CABLE SIZE: 2 RUN OF 3C X 300 SQ.MM Mounting : wall / concrete / steel structure

1

-

-

... More
Type-6 : Power Junction Box . INCOMING CABLE SIZE: 2 RUNS 3C X 120 SQMM OUTGOING CABLE SIZE: 1 RUN. 3C X 25 SQMM Mounting : wall / concrete / steel structure

5

-

-

... More
Type-7 : Power Junction Box. INCOMING CABLE SIZE: 1 RUNS 3C X 300 SQMM OUTGOING CABLE SIZE: 2 RUNS. 3C X 50 SQMM Mounting : wall / concrete / steel structure

6

-

-

... More
Type-8 : Power Junction Box. INCOMING CABLE SIZE: 1 RUNS 4C X 150 SQMM OUTGOING CABLE SIZE: 1 RUN 4C (35-50) SQMM Mounting : wall / concrete / steel structure

15

-

-

... More
Type-9 : Power Junction Box. INCOMING CABLE SIZE: 1 RUNS 4C X 240 SQMM OUTGOING CABLE SIZE: 1 RUN 4C X 50 SQMM Mounting : wall / concrete / steel structure

12

-

-

... More
Type-10 : Power Junction Box. INCOMING CABLE SIZE: 7 RUNS OF 4C X 300 SQ.MM OUTGOING CABLE SIZE: 3 RUN OF 4C X 240 SQ.MM Mounting : wall / concrete / steel structure

1

-

-

... More
POWER OUTLET: Supply,Installation, testing and commissioning of metal clad industrial type socket and plug with interlocking switch, with loop in-loop out, including supply of double compresion brass nickel plated cable glands, tinned copper lugs, including all accessories as per approved drawings, specification NR-0ZZZZ-EL-SPE-0023 of this tender and directions of Engineer-in-charge.

-

-

-

... More
63A, 415 VAC, 5 Pin, Flameproof (Ex d) suitable for hazardous area Zone 1& 2, IIA/IIB/IIC, T3, outdoor, IP-65 min, with necessary mechanical interlocks and earthing facilities.

35

-

-

... More
63A, 415 VAC, 5 Pin, Suitable for corrosive area,weather proof, outdoor, IP-65 min, with necessary mechanical interlocks and earthing facilities.

10

-

-

... More
SUPPLY OF MANDATORY SPARE FOR POWER OUTLET

-

-

-

... More
63A, 415 VAC, 5 Pin, Flameproof (Ex d) suitable for hazardous area Zone 1& 2, IIA/IIB/IIC, T3, outdoor, IP-65 min, with necessary mechanical interlocks and earthing facilities.

20

-

-

... More
CONVENIENCE OUTLET: Supply,Installation, testing and commissioning of flame proof metal clad industrial type socket and plug with interlocking switch, with loop in-loop out, including supply of double compresion brass nickel plated cable glands, tinned copper lugs, including all accessories as per approved drawings, specification NR-0ZZZZ-EL-SPE-0023 of this tender and directions of Engineer-in-charge.

-

-

-

... More
16A , 240V, 1Ph, 3Pin, Flameproof (Ex d) suitable for hazardous area Zone 1& 2, IIA/IIB/IIC, T3, outdoor, IP-65 min, with necessary mechanical interlocks and earthing facilities.

15

-

-

... More
6A ,24V, 1Ph, 3Pin,Flameproof (Ex d) suitable for hazardous area Zone 1& 2, IIA/IIB/IIC, T3, outdoor, IP-65 min, Socket Outlet with integral 240V/24VAC/DC Transformer

5

-

-

... More
Portable Flameproof Hand lamp,24V, 10W with driver and accessories, flame proof plug, suitable for hazardous area Zone 1& 2, IIA/IIB/IIC, T3, outdoor, IP-65 min, used for tank and vessel lighitng for confined space entry, and suitable for above line item. It shall be supplied complete with 20 meter length of 3Cx2.5 Sq. mm copper conductor, PVC insulated, metal braided flexible cable, duly terminated in the hand lamp at one end and having 24V plug on the other end.

5

-

-

... More
SUPPLY OF MANDATORY SPARE FOR ONVENIENCE OUTLET

-

-

-

... More
16A , 240V, 1Ph, 3Pin, Flameproof (Ex d) suitable for hazardous area Zone 1& 2, IIA/IIB/IIC, T3, outdoor, IP-65 min, with necessary mechanical interlocks and earthing facilities.

20

-

-

... More
LIGHTING POLE: Supply,Installation, testing and commissioning of lighting poles for floor/handrail mounting as per approved drawings,installation standards-TP-1ZZZA-EL-STC-0003, specifications NR-0ZZZZ-EL-SPE-0023 of this tender, below description and directions of Engineer-in-Charge and as per approved drawing along with fixing hardware like U clamp & bolt. Including welding, structural works, paint and all sundry materials as required. This shall include all labour and materials complete as per approved drawings, specification of this tender and directions of Engineer-in-charge. This shall include local transportation to storage area and from storage area to actual place of installation by contractor's own lifting & transporting arrangement.The installation of Lighting pole will be carried out as per IFC drawing & suit to site conditions to avoid fouling with other Piping, Structure & access ways

-

-

-

... More
Lighting pole as per STC L01A, for street lighting , 9 Meter Height Hot dip Galvanised Tubular / Ooctagonal Street Lighting Pole as per IS 2713 of Single ARM,complete with two earthing lugs at the bottom, cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including four nos. foundation Anchor bolts, nuts & washers to fix the base plate to foundation, etc. and accessories. The lighting pole shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity, including supply of weather proof junction box and other accessories suitable for outdoor installation as per drawings, specification of this tender and directions of Engineer-in-charge. Site Conditions as specified in the SOW in addition to the below points to be considered for design and installation of 9 meter height Single ARM Tubular Street Lighting Pole: ● Wind speed : 50 meter / sec The Lighting Pole shall comply to the tender specification including the below points : ● Poles shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity. ● The pole shaft shall be made from sheet steel . ● The pole shaft shall have tubular / octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. ● GI Base Plate of minium 500 X 500 X 10 mm. ● Suitable for mounting / installation 120 Watt LED based street lighting fixture.

39

-

-

... More
Lighting pole as per STC L02, for flood lighting , 9 Meter Height Hot dip Galvanised Tubular / Ooctagonal Flood Lighting Pole as per IS 2713 provision at the top for installing 2 Nos. of flood light fixtures,complete with two earthing lugs at the bottom, cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including four nos. foundation Anchor bolts, nuts & washers to fix the base plate to foundation, etc. and accessories. The lighting pole shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity, including supply of flame proof Exd junction box and other accessories suitable for outdoor installation as per drawings, specification of this tender and directions of Engineer-in-charge. Site Conditions as specified in the SOW in addition to the below points to be considered for design and installation of 9 meter height Flood Lighting Pole: ● Wind speed : 50 meter / sec The Lighting Pole shall comply to the tender specification including the below points : ● Poles shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity. ● The pole shaft shall be made from sheet steel . ● The pole shaft shall have tubular / octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. ● GI Base Plate of minium 500 X 500 X 10 mm. ● Suitable for mounting / installation 225 & 400 Watt LED based flood ighting fixture.

100

-

-

... More
Lighting pole as per STC L02, for flood lighting , 9 Meter Height FRP Flood Lighting Pole as per IS 2713 provision at the top for installing 2 Nos. of flood light fixtures,complete with two earthing lugs at the bottom, cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including four nos. foundation Anchor bolts, nuts & washers to fix the base plate to foundation, etc. and accessories. The lighting pole shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity, including supply of weather proof FRP junction box and other accessories suitable for outdoor installation as per drawings, specification of this tender and directions of Engineer-in-charge. Site Conditions as specified in the SOW in addition to the below points to be considered for design and installation of 9 meter height Single Flood Lighting Pole: ● Wind speed : 50 meter / sec The Lighting Pole shall comply to the tender specification including the below points : ● Poles shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity. ● The pole shaft shall be made from sheet steel . ● The pole shaft shall have tubular / octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. ● GI Base Plate of minium 500 X 500 X 10 mm. ● Suitable for mounting / installation 225 & 400 Watt LED based flood ighting fixture.

20

-

-

... More
Lighting pole as per STC L04, 3.5 meter height,hot dip galvanized GI , heavy duty, round shaped or tapered, one or two piece construction, with base plate, including provision at the top for installing one well glass light fixture,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including foundation bolts, nuts & washers to fix the base plate to foundation, etc.

150

-

-

... More
Lighting pole as per STC L05, 2.5 meter height ,hot dip galvanized GI , heavy duty, round shaped or tapered, one or two piece construction, with base plate, including provision at the top for installing one well glass light fixture,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including fixing bolts, nuts & washers etc. .

920

-

-

... More
FRP Lighting pole as per STC L04, 3.5 meter height, heavy duty, round shaped or tapered, one or two piece construction, with base plate, including provision at the top for installing one well glass light fixture,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including foundation bolts, nuts & washers to fix the base plate to foundation, etc. .

10

-

-

... More
FRP Lighting pole as per STC L05, 2.5 meter height, heavy duty, round shaped or tapered, one or two piece construction, with base plate, including provision at the top for installing one well glass light fixture,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including fixing bolts, nuts & washers etc. .

10

-

-

... More
Light Mount Bracket Arm as per STC L06, for wall/Column mounted lighting,hot dip galvanized GI ,heavy duty, round shaped, single ARM of 1.1 mtrs including accessories,including provision at the top for installing one street light fixture,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including fixing bolts, nuts & washers, etc. . .

11

-

-

... More
Socket outlet pole as per STC L15D, for Handrail mounting, 1.5 meter height,,hot dip galvanized GI ,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including fixing bolts, nuts & washers etc. .

15

-

-

... More
Socket outlet pole as per STC L15D, for Handrail mounting, 1.5 meter height,,FRP ,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including fixing bolts, nuts & washers etc. .

10

-

-

... More
SUPPLY OF MANDATORY SPARE FOR LIGHTING POLES

-

-

-

... More
Lighting pole as per STC L01A, for street lighting , 9 Meter Height Hot dip Galvanised Tubular / Ooctagonal Street Lighting Pole as per IS 2713 of Single ARM,complete with two earthing lugs at the bottom, cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including four nos. foundation Anchor bolts, nuts & washers to fix the base plate to foundation, etc. and accessories. The lighting pole shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity, including supply of weather proof junction box and other accessories suitable for outdoor installation as per drawings, specification of this tender and directions of Engineer-in-charge. Site Conditions as specified in the SOW in addition to the below points to be considered for design and installation of 9 meter height Single ARM Tubular Street Lighting Pole: ● Wind speed : 50 meter / sec The Lighting Pole shall comply to the tender specification including the below points : ● Poles shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity. ● The pole shaft shall be made from sheet steel . ● The pole shaft shall have tubular / octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. ● GI Base Plate of minium 500 X 500 X 10 mm. ● Suitable for mounting / installation 120 Watt LED based street lighting fixture.

4

-

-

... More
Lighting pole as per STC L02, for flood lighting , 9 Meter Height Hot dip Galvanised Tubular / Ooctagonal Flood Lighting Pole as per IS 2713 provision at the top for installing 2 Nos. of flood light fixtures,complete with two earthing lugs at the bottom, cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including four nos. foundation Anchor bolts, nuts & washers to fix the base plate to foundation, etc. and accessories. The lighting pole shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity, including supply of flame proof Exd junction box and other accessories suitable for outdoor installation as per drawings, specification of this tender and directions of Engineer-in-charge. Site Conditions as specified in the SOW in addition to the below points to be considered for design and installation of 9 meter height Lighting Pole: ● Wind speed : 50 meter / sec The Lighting Pole shall comply to the tender specification including the below points : ● Poles shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity. ● The pole shaft shall be made from sheet steel . ● The pole shaft shall have tubular / octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. ● GI Base Plate of minium 500 X 500 X 10 mm. ● Suitable for mounting / installation 120 Watt LED based flood ighting fixture.

8

-

-

... More
Lighting pole as per STC L02, for flood lighting , 9 Meter Height FRP Flood Lighting Pole as per IS 2713 provision at the top for installing 2 Nos. of flood light fixtures,complete with two earthing lugs at the bottom, cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including four nos. foundation Anchor bolts, nuts & washers to fix the base plate to foundation, etc. and accessories. The lighting pole shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity, including supply of weather proof FRP junction box and other accessories suitable for outdoor installation as per drawings, specification of this tender and directions of Engineer-in-charge. Site Conditions as specified in the SOW in addition to the below points to be considered for design and installation of 9 meter height Lighting Pole: ● Wind speed : 50 meter / sec The Lighting Pole shall comply to the tender specification including the below points : ● Poles shall be bolted on a pre-cast foundation with a set of four Foundation bolts for greater rigidity. ● The pole shaft shall be made from sheet steel . ● The pole shaft shall have tubular / octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. ● GI Base Plate of minium 500 X 500 X 10 mm. ● Suitable for mounting / installation 120 Watt LED based flood ighting fixture.

4

-

-

... More
Lighting pole as per STC L04, 3.5 meter height,hot dip galvanized GI , heavy duty, round shaped or tapered, one or two piece construction, with base plate, including provision at the top for installing one well glass light fixture,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including foundation bolts, nuts & washers to fix the base plate to foundation, etc.

20

-

-

... More
Lighting pole as per STC L05, 2.5 meter height ,hot dip galvanized GI , heavy duty, round shaped or tapered, one or two piece construction, with base plate, including provision at the top for installing one well glass light fixture,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including fixing bolts, nuts & washers etc. .

30

-

-

... More
FRP Lighting pole as per STC L04, 3.5 meter height, heavy duty, round shaped or tapered, one or two piece construction, with base plate, including provision at the top for installing one well glass light fixture,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including foundation bolts, nuts & washers to fix the base plate to foundation, etc. .

10

-

-

... More
FRP Lighting pole as per STC L05, 2.5 meter height, heavy duty, round shaped or tapered, one or two piece construction, with base plate, including provision at the top for installing one well glass light fixture,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including fixing bolts, nuts & washers etc. .

10

-

-

... More
Light Mount Bracket Arm as per STC L06, for wall/Column mounted lighting,hot dip galvanized GI , heavy duty, round shaped, single ARM of 1.1 mtrs including accessories,including provision at the top for installing one street light fixture,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including fixing bolts, nuts & washers, etc. . .

10

-

-

... More
Socket outlet pole as per STC L15D, for Handrail mounting, 1.5 meter height,,hot dip galvanized GI ,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including fixing bolts, nuts & washers etc. .

10

-

-

... More
Socket outlet pole as per STC L15D, for Handrail mounting, 1.5 meter height,,FRP ,complete with earthing lugs at the bottom, adaptor/reducer cable entry holes with blanking rubber gromments, provision to mount the cable junction box at the bottom, including fixing bolts, nuts & washers etc. .

10

-

-

... More
POINT WIRING: Point wiring in concealed/ surface conduit including supply and erection of GI/PVC conduits with complete accessories, copper wires, recessed GI boxes housing switches/sockets of 5A/ 15A rating,lighting fixture box including chipping and remaking of chases for walls/ ceilings for embedding conduits, cutting and sealing of wall for installing boxes etc.

-

-

-

... More
LIGHT/SOCKET POINT CONTROLLED BY ONE WAY SWITCH

-

-

-

... More
Supply and wiring of light point with 2.5 sq.mm PVC insulated , FR, copper conductor wire in surface/ recessed 25 mm dia GI/PVC/ metsec conduit including all accessories on surface or in recess, including supply and fixing of 5A one way switch/ GI box including circuit wiring, earthing of light fixture with 2.5 sqmm PVC insulated FR, copper wire etc. as required. The above scope includes cutting, chasing of wall and filling the chases with mortar and making good finish as required. Wire and switch shall also form part of point wiring and will not be paid separately.

40

-

-

... More
Supply and wiring of light point with 4 sq.mm PVC insulated , FR, copper conductor wire in surface/ recessed 25 mm dia GI/PVC/ metsec conduit including all accessories on surface or in recess, including supply and fixing of 5A one way switch/ GI box including circuit wiring, earthing of light fixture with 2.5 sqmm PVC insulated FR, copper wire etc. as required. The above scope includes cutting, chasing of wall and filling the chases with mortar and making good finish as required. Wire and switch shall also form part of point wiring and will not be paid separately.

20

-

-

... More
LIGHT/SOCKET POINT CONTROLLED BY MCB IN LIGHTING PANEL

-

-

-

... More
Supply and wiring of light point controlled by MCB in LDB with 2.5 sq.mm PVC insulated, FR, copper conductor wire in surface/ recessed 25 mm dia GI/PVC conduit / metsec channel including all accessories on surface or in recess, including earthing of light fixture with 2.5 sqmm PVC insulated, FR, copper conductor wire etc. as required. The above scope includes cutting, chasing of wall and filling the chases with mortar and making good finish as required. Wire shall also form part of point wiring and will not be paid separately.

20

-

-

... More
Supply and wiring of light point controlled by MCB in LDB with 4 sq.mm PVC insulated, FR, copper conductor wire in surface/ recessed 25 mm dia GI/PVC conduit / metsec channel including all accessories on surface or in recess, including earthing of light fixture with 2.5 sqmm PVC insulated, FR, copper conductor wire etc. as required. The above scope includes cutting, chasing of wall and filling the chases with mortar and making good finish as required. Wire shall also form part of point wiring and will not be paid separately.

20

-

-

... More
LIGHT/SOCKET POINT

-

-

-

... More
Supply and wiring of light point with 2.5 sq.mm PVC insulated , FR, copper conductor wire in surface/ recessed 25 mm dia GI/PVC/ metsec conduit including all accessories on surface or in recess,earthing of light fixture with 2.5 sqmm PVC insulated FR, copper wire etc. as required. The above scope includes cutting, chasing of wall and filling the chases with mortar and making good finish as required. Wire shall also form part of point wiring and will not be paid separately.

20

-

-

... More
Supply and wiring of light point with 4 sq.mm PVC insulated , FR, copper conductor wire in surface/ recessed 25 mm dia GI/PVC/ metsec conduit including all accessories on surface or in recess,earthing of light fixture with 2.5 sqmm PVC insulated FR, copper wire etc. as required. The above scope includes cutting, chasing of wall and filling the chases with mortar and making good finish as required. Wire shall also form part of point wiring and will not be paid separately.

20

-

-

... More
MOUNTING BRACKET-SUPPLY & INSTALLATION: Supply (as per the details provided in installation standard for lighting-TP-1ZZZA-EL-STC-0003) and Installation of lighting fixture mounting bracket by welding / fixing with anchor fastners as per typical installation detail , including welding, supply of fixing fastners and all accessories on concrete/steel, sealing of mounting bracket/ pipe & supply of sealing compound/material, supply and painting with one coat of red oxide and two coats of final finish paint and installation of suitable junction box as per the Lighing block diagram as per STC L08

-

-

-

... More
Mounting bracket for LED fixtures well glass bracket mounted lighting fixtures as per STC L07

1028

-

-

... More
Mounting bracket for LED Pendant mounted tubular lighting fixtures as per STC L09A

782

-

-

... More
Mounting bracket for LED Ceiling Mounted / Wall Mounted tubular lighting fixtures as per STC L09B & L09C

167

-

-

... More
Mounting bracket for handrail mounted flood lighting fixtures as per STC L11

10

-

-

... More
Mounting bracket for steel structure mounted flood lighting fixtures as per STC L12

162

-

-

... More
Mounting bracket for LED Pendant mounted High / Medium / Low Bay Light Fixtures as per STC L13

10

-

-

... More
Mounting bracket for Aviation Warning Light as per STC L14

10

-

-

... More
Mounting bracket for steel structure mounted socket outlet as per STC L15A,15C

10

-

-

... More
Mounting bracket for ceiling/wall mounted socket outlet as per STC L15B

10

-

-

... More
SUPPLY OF MANDATORY SPARE FOR MOUNTING BRACKET

-

-

-

... More
Mounting bracket for LED fixtures well glass bracket mounted lighting fixtures as per STC L07

100

-

-

... More
Mounting bracket for LED Pendant mounted tubular lighting fixtures as per STC L09A

50

-

-

... More
Mounting bracket for LED Ceiling Mounted / Wall Mounted tubular lighting fixtures as per STC L09B & L09C

50

-

-

... More
Mounting bracket for handrail mounted flood lighting fixtures as per STC L11

10

-

-

... More
Mounting bracket for steel structure mounted flood lighting fixtures as per STC L12

50

-

-

... More
Mounting bracket for LED Pendant mounted High / Medium / Low Bay Light Fixtures as per STC L13

10

-

-

... More
Mounting bracket for Aviation Warning Light as per STC L14

10

-

-

... More
Mounting bracket for steel structure mounted socket outlet as per STC L15A,15C

10

-

-

... More
Mounting bracket for ceiling/wall mounted socket outlet as per STC L15B

10

-

-

... More
HIGH MAST LIGHTING: Supply, Installation, earthing, glanding, termination of incoming and outgoing cables/ wires at luminaire , testing and commissioning of lighting luminaires and other accessories suitable for outdoor installation. This shall include transportation from owner's issue point to actual place of installation by contractor's own lifting & transporting arrangement, unpacking, assembly of luminaries, drilling etc. as required, all labour and material complete as per drawings, specification of this tender and directions of Engineer-in-charge. This will include any modifications required to be carried out on the mounting bracket to suit mounting of lighting fixtures & any modifications required for proper commissioning of fixture. Following Site Conditions in addition to the site condition mentioned in the Elec SOW of this tender will be considered for design and installation of 30 meter heigh High Mast : ● Wind speed : 50 meter / sec The High Mast shall be comply the flowing codes and standards as minimum, but not limited to the following : ●. PLG 7 High Masts for Lighting and CCTV ●. SANS 10225:2012 High Mast natural frequency calculation ●. IS 875 Part – 3 Wind Loading ●. IS 2062/ BS EN 10025 High Tensile Steel Sheets ●. IS 2062 Mild Steel ●. BS EN ISO 1461 Galvanization ●. IS 3459 / 2266 Stainless steel Wire rope ●. IS 9968 Part – 1 Trailing Cable ●. IS 12615 Motor ●. IP66, IK08, wind tunnel test on a specimen to establish the force coefficients of the 20-side polygon and the value received from the wind tunnel test is to be taken in design, The winches are to be type tested through reputed institutions like IIT as consultants.30 Meter High Mast with 12x400W LED Lighting fixtures comprising of the following as a minimum :

-

-

-

... More
● 30 Meter High Mast shaft in three sections suitable for required wind speed with raising / lowering system comprising of frame for luminaries carriage suitable to install 12 nos luminaries in symmetrical arrangement, SS Wire rope, trailing cable, motor, manual handle, junction box, lightning protections including lighting finile and all other accessories required for the complete installation of the High Mast. ● MS anchor Foundation bolts as per Civil drawing no : TP-1ZZZA-CV-COD-0007.01 along with nuts, washers, anchor plates and templates ● Non-integral flood light luminaries of 400W LED Fixtures with control gear boxes ● Two nos. aviation obstruction lights with 9W LED Lamps ● Outdoor stand mounted flameproof MCB DB/ flameproof Feeder pillar distribution box with Incomer / outgoing MCB, ELCB, timers suitable for Zone 2 gas group IIA/IIB, Temp. Class T3. ● Trailing cables, wires as required (except the incoming power cables to Feeder Pillar Box / MCB Distribution Box). ● Supply shall include commissioning spares as required (List shall be provided by bidder)

1

-

-

... More
EQUIPMENT- SUPPLY

-

-

-

... More
LOCAL CONTROL STATION

-

-

-

... More
FLAMEPROOF TYPE: Supply Installation, Testing & Commissioning of flameproof type Exd local control station (LCS), the LCS shall be made of aluminium alloy (LM6) and shall be free from frictional sparking hazard. The magnesium content in the alloy shall be as per IS / IEC 60079-0.with IP-65 protection suitable for Zone 1/ Zone 2, IIA/IIB/IIC, T3 as per specification No. -NR-0ZZZZ-EL-SPE-0023 and TP-1ZZZA-EL-BOD-0001 and Annexure-2, as per approved drawings, standard specification, mandatary spares,etc.as detailed in the SOW of this tender. The local control station shall be supplied along with requisite number of flameproof double compression cable glands required for incoming and outgoing cables and 40% plug (for plugging unused entry) . The cable data will be shared during detail engineering for correct selection of cable gland.The cost of cable glands shall be included and no separate payment for cable gland is envisaged. The local control station shall be provided with GI canopy. This also includes supply of necessary hardware, cement, sand , touch up painting, stenciling if required, Including Lifting & Transportation from Owner's issue point to the place of installation with contractor's own lifting and transportation arrangement, unpacking, assembly, including all labour and materials complete as per approved drawings, specification of this tender and directions of Engineer-in-charge.

-

-

-

... More
Start & Stop Push Button

19

-

-

... More
Start & Stop Push Button, Local/Remote Switch

2

-

-

... More
Start & Stop Push Button, Ammeter

19

-

-

... More
Start & Stop Push Button, Ammeter, Local/Remote Switch

34

-

-

... More
TNC Switch, Ammeter

1

-

-

... More
TNC Switch, Local/Remote Switch

1

-

-

... More
TNC Switch, Ammeter, Local/Remote Switch

1

-

-

... More
Emergency Stop Pust Button

1

-

-

... More
SUPPLY OF MANDATORY SPARE FOR FLAMEPROOF TYPE

-

-

-

... More
Start & Stop Push Button

2

-

-

... More
Start & Stop Push Button, Ammeter

2

-

-

... More
Start & Stop Push Button, Ammeter, Local/Remote Switch

2

-

-

... More
Supply of Mandatary spares for Local Control Station as per section-H-1.1-TP-1ZZZA-PQ-PRC-0005_P2-SPARE PARTS, SPECIAL TOOLS AND CONSUMABLES PHILOSOPHY

1

-

-

... More
WEATHERPROOF INDUSTRIAL TYPE: Supply Installation, Testing & Commissioning of Industrial type weather proof local control station (LCS), the LCS shall be made of sheet steel or cast light metal alloy of min thickness 2mm with IP-56 protection. The LCS shall be supplied as per specification No. -NR-0ZZZZ-EL-SPE-0023 and TP-1ZZZA-EL-BOD-0001 and Annexure-2, as per approved drawings, standard specification, mandatary spares,etc.as detailed in the SOW of this tender.. The local control station shall be supplied along with requisite number of double compression suitable cable glands required for incoming and outgoing cables and 40% plug (for plugging unused entry) . The cable data will be shared during detail engineering for correct selection of cable gland.The cost of cable glands shall be included and no separate payment for cable gland is envisaged. The local control station shall be provided with GI canopy. This also includes supply of necessary hardware, cement, sand , touch up painting, stenciling if required, Including Lifting & Transportation from Owner's issue point to the place of installation with contractor's own lifting and transportation arrangement, unpacking, assembly, including all labour and materials complete as per approved drawings, specification of this tender and directions of Engineer-in-charge.

-

-

-

... More
Emergency stop push button

50

-

-

... More
NEUTRAL EARTHING RESISTOR (NER): Supply Installation, Testing & Commissioning of following rating of outdoor type neutral grounding resistor, as per standard specification , approved drawings, specifications NR-0ZZZZ-EL-SPE-0011 and data sheet TP-1ZZZA-EL-DAT-0006 and ITP-TP-1ZZZA-EL-ITP-0036 of this tender. This shall include connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Rating : 400 A for 30 sec, 6.6/√3 kV, with Vacuum Contactor for Switching with Local / remote switch, suitable for outdoor installation

8

-

-

... More
Supply of Mandatary spares for NER as per section-H-1.1-TP-1ZZZA-PQ-PRC-0005_P2-SPARE PARTS, SPECIAL TOOLS AND CONSUMABLES PHILOSOPHY

1

-

-

... More
EQUIPMENT - INSTALLATION , TESTING & COMMISSIONING: Installation, Testing and commissioning of transformers of below mentioned ratings Outdoor / Indoor transformers excluding the construction of foundation, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, placing on foundation, replacement of silica gel, connection of primary & secondary sides, phase checking, meggering, HV test, touch up painting including connection of auxiliary circuits, including fixing of nuts and bolts etc. filling/topping up of oil, providing stoppers for wheels etc.,including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Lifting & Transportation from Owner's issue point to the place of installation with contractor's own lifting and transportation arrangement is in contractor scope. Also any assitance required to Client for CEA approval shall be in Contractor's scope. Before performing any activity (e.g. testing/ commisiong/ oil filteration etc) Contractor must / shall submit the procedure to Engineer-in-charge for his review. Also any other activities required to complete the job & not specifically mentioned here shall also be in contractor's scope. Any assistance as required by MANUFACTURER's supervisor at Site during the above activities is also included in the scope.

-

-

-

... More
GRID TRANSFORMERS (OIL FILLED)

-

-

-

... More
220/33KV, 80/100/120MVA, ONAN/ONAF/OFAF , outdoor installation with OLTC for Substation-21. Approx. dimension (13000mm x 7000mmx 8000mm) and weight 100000 Kg

4

-

-

... More
POWER & DISTRIBUTION TRANSFORMERS (OIL FILLED)

-

-

-

... More
16/20MVA Rating , 33 kV/6.9kV, ONAN/ONAF, outdoor installation with OCTC for Substation-10. Approx. dimension 6500(L) X 5300(W) X 4900(H) MM and weight 41700 Kg.

2

-

-

... More
25/31.5MVA Rating , 33 kV/6.9kV, ONAN/ONAF, outdoor installation with OCTC for Substation-13 . Approx. dimension 7000(L) X 5600(W) X 5100(H) MM and weight 41700 Kg.

2

-

-

... More
20/25MVA Rating , 33 kV/6.9kV, ONAN/ONAF, outdoor installation with OCTC for Substation-14 . Approx. dimension 6700(L) X 5500(W) X 5000(H) MM and weight 41700 Kg.

2

-

-

... More
12.5/16MVA Rating , 33 kV/6.9kV, ONAN/ONAF, outdoor installation with OCTC for Substation-18 . Approx. dimension 6400(L) X 5300(W) X 4800(H) MM and weight 41700 Kg.

2

-

-

... More
2 MVA Rating , 6.6 kV/0.433 kV, ONAN, outdoor installation with OCTC for Substation-10, 13, 14, 17, 18 & 30 . Approx. dimension 3600(L) X 2400(W) X 3000(H) MM and weight 7520 Kg.

28

-

-

... More
2.5 MVA Rating , 6.6 kV/0.433 kV, ONAN, outdoor installation with OCTC for Substation- 18. Approx. dimension 3600(L) X 2400(W) X 3000(H) MM and weight 8000 Kg.

4

-

-

... More
0.8 MVA Rating , 6.6 kV/0.433 kV, ONAN, outdoor installation with OCTC for Substation-21 . Approx. dimension 2500(L) X 2000(W) X 2000(H) MM and weight 6520 Kg.

2

-

-

... More
1.25 MVA Rating , 6.6 kV/0.433 kV, ONAN, outdoor installation with OCTC for Substation-MCR#2 Approx. dimension 3600(L) X 2400(W) X 3000(H) MM and weight 7520 Kg.

2

-

-

... More
Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. (Excluding the supply of oil). - Filtration of transformer oil with dissolved gas analysis test.

100000

-

-

... More
DRY TYPE TRANSFORMER: Installation, Testing and commissioning of transformers of below mentioned ratings Indoor transformers excluding the construction of foundation, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, placing on foundation, replacement of silica gel, connection of primary & secondary sides, phase checking, meggering, HV test, touch up painting including connection of auxiliary circuits, providing stoppers for wheels etc.,including fixing of nuts and bolts etc.and all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Lifting & Transportation from Owner's issue point to the place of installation with contractor's own lifting and transportation arrangement is in contractor scope. Also any assitance required to Client for CEA approval shall be in Contractor's scope. Before performing any activity (e.g. testing/ commisiong etc) Contractor must / shall submit the procedure to Engineer-in-charge for his review. Also any other activities required to complete the job & not specifically mentioned here shall also be in contractor's scope. Any assistance as required by MANUFACTURER's supervisor at Site during the above activities is also included in the scope.

-

-

-

... More
315 KVA Rating , 415/433V, Dry type, suitable for Indoor installation

2

-

-

... More
250 KVA Rating , 415/433V, Dry type, suitable for Indoor installation

2

-

-

... More
160 KVA Rating , 415/433V, Dry type, suitable for Indoor installation

4

-

-

... More
100 KVA Rating , 415/433V, Dry type, suitable for Indoor installation

7

-

-

... More
75 KVA Rating , 415/433V, Dry type, suitable for Indoor installation

6

-

-

... More
30 KVA Rating , 415/433V, Dry type, suitable for Indoor installation

4

-

-

... More
DIESEL GENERATOR SET: Installation, Testing,Operational and Functional checking, Relay settings, calibration of relays/meters (if any) and commissioning of Diesel Generator including the control panels of the following ratings including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, placing on foundation, meggering, touch up painting including connection of auxiliary circuits, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Construction of foundation is excluded here. Any assistance as required by MANUFACTURER's supervisor at Site during the above activities is also included in the scope. Also any assitance required to Client for CEA approval shall be in Contractor's scope. Diesel topup in the Diesel day tank for testing & commissioning / trial run shall be in electrical contractor scope,however diesel will be provided by NRL / Client

-

-

-

... More
Installation, Testing,Operational and Functional checking, Relay settings, calibration of relays/meters (if any) and commissioning of Diesel Generator including the control panels of the following ratings including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, placing on foundation, meggering, touch up painting including connection of auxiliary circuits, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Construction of foundation is excluded here. Any assistance as required by MANUFACTURER's supervisor at Site during the above activities is also included in the scope. 2250KVA, 6.6kV, 0.8 pf, Diesel Generator Set including fuel oil tank, exhaust stack and all associated accessories. Approx. dimension 9000(L) X 2600(W) X 3210(H) MM and weight 15000kg Also any assitance required to Client for CEA approval shall be in Contractor's scope.

5

-

-

... More
1500KVA, 415V, 0.8 pf, Diesel Generator Set including ACB Operated Control / Protection Panel (with AMF facility), fuel oil tank, exhaust ducts (if any) and all associated accessories. Approx. dimension 9000(L) X 2600(W) X 3210(H) MM and weight 15000kg

1

-

-

... More
Dismantling of EDG including ACB Operated Control / Protection Panel (with AMF facility), fuel oil tank, exhaust ducts and all associated accessories from the exiting location.

-

-

-

... More
910 KVA, 415V, Approx. dimension 8000(L) X 2600(W) X 3000(H) MM and weight 13000kg

4

-

-

... More
510 KVA, 415V, Approx. dimension 6000(L) X 2000(W) X 2500(H) MM and weight 8500kg

1

-

-

... More
Relocating of existing EDG including ACB Operated Control / Protection Panel (with AMF facility), fuel oil tank, exhaust ducts and all associated accessories from the existing location to the location of installation and re-installation of the same in the proposed location as per the layout and the instructions of the Engineer-in-charge.

-

-

-

... More
910 KVA, 415V, Approx. dimension 8000(L) X 2600(W) X 3000(H) MM and weight 13000kg

3

-

-

... More
510 KVA, 415V, Approx. dimension 6000(L) X 2000(W) X 2500(H) MM and weight 8500kg

1

-

-

... More
HV/MV BUSDUCTS: Installation, Earthing, Testing & Commissioning of bus duct of following ratings between transformer and the switchgear incomer panel,fixing of structural supports (Structural supports will be free issued by MPMC/OWNER) including connection at transformer and panel ends of HV/LV bus duct. Including Lifting & Transportation from Owner's issue point to the place of installation with contractor's own lifting and transportation arrangement, unpacking, assembly, making connections and installation of bends, breaking of walls and making good of the same etc., finishing and sealing of holes in brick/ stone/concrete wall , installation of Wall frame assembly for bus duct entry to panel room, installation of rain Protection canopy for busduct ( for out door protection) etc. including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-charge. Any assistance as required by MANUFACTURER's supervisor at Site during the above activities is also included in the scope. Also any assitance required to Client for CEA approval shall be in Contractor's scope. (The rate mentioned here shall include installation of straight lengths bends, turns, adaptor boxes, phase crossovers,supports and other accesories as applicable as per the preliminay Busduct layout Annexure-3 for different Substations(qty includes all Substations busduct current rating wise), attached part of this tender. Cost will be paid on the total length installed including straight lengths bends, turns, adaptor boxes, phase crossovers,supports and other accesories )

-

-

-

... More
6.6kV, 3PH, 3W, 50HZ, 3150A,40KA for 1sec

50

-

-

... More
6.6kV, 3PH, 3W, 50HZ, 2500A,40KA for 1sec

30

-

-

... More
6.6kV, 3PH, 3W, 50HZ, 2000A,40KA for 1sec

60

-

-

... More
415V, 3PH, 3W, 50HZ, 3150A,50KA for 1sec

500

-

-

... More
415V, 3PH, 3W, 50HZ, 4000A,50KA for 1sec

500

-

-

... More
HV / LV SWITCHBOARDS / HV / LV VFD PANELS /RTCC PANELS/ UPS PANELS / BATTERY CHARGER PANELS / CAPACITOR BANKS/ HV PFIC CONTROL PANELS /SOFT STARTERS/ ANNUNCIATION PANELS / CONTROL PANELS / THYRISTORISED HEATER CONTROL PANELS / ECS & APM PANELS / DISTRIBUTION BOARDS/ OTHER MISC. PANELS (FLOOR / WALL MOUNTED) SUPPLIED BY OTHERS Installation, testing ,Operational and Functioal checking, Setting of relays, calibration of relays/meters (if any) and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VFD panels,soft starter panels, misc .electrical panels etc.,supplied by OTHERS including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring material & copper lugs for wiring, drilling of gland plates for cable gland fixing, plugging of unused cable entries etc.,installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, etc.,including minor civil work like chipping, cutting, refilling and sealing of pockets in wall/floor etc. including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Any modification/alteration to be carried out in individual shipping section for proper alignment & matching with other sections etc, Supply of grouting materials, foundation bolts if not supplied with equipment, pluges for unused cable entries, hardware materials, touch up painting as required. Complete with labour & materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. Any assistance as required by MANUFACTURER's supervisor at Site during the above activities is also included in the scope. Also any assitance required to Client for CEA approval shall be in Contractor's scope.

-

-

-

... More
Shipping section / Unit weight from 101 kgs to 500kgs

10

-

-

... More
Shipping section / Unit weight from 501 kgs to 1000kgs

100

-

-

... More
Shipping section / Unit weight from 1001 kgs to 1500kgs

672

-

-

... More
Shipping section / Unit weight from 1501 kgs to 3000kgs

80

-

-

... More
MISCELLANEOUS PANELS SUPPLIED BY OTHERS: Installation, Testing & Commissioning of Industrial / flameproof local control stations (LCS) / motor starters / communication equipment / junction boxes / misc. panels etc, supplied by OWNER/MPMC.This also includes supply of necessary hardware, cement, sand , touch up painting, stenciling if required, Including Lifting & Transportation from Owner's issue point to the place of installation with contractor's own lifting and transportation arrangement, unpacking, assembly, including all labour and materials complete as per approved drawings, specification of this tender and directions of Engineer-in-charge.

-

-

-

... More
Weight of the unit upto 5 kg.

47

-

-

... More
Weight of the unit above 5 kg but upto 10kg.

74

-

-

... More
Weight of the unit above 10 kg but upto 15kg.

5

-

-

... More
Weight of the unit above 15 kg but upto 25kg.

5

-

-

... More
Weight of the unit above 25 kg but upto 100kg.

5

-

-

... More
BATTERY BANK INSTALLATION: Installation, Testing & Commissioning of Nickle-cadmium battery banks of following ratings on wooden/PVC coated steel stand / or as applicable, in single/double tier, single/double row formation including lifting & transportation from Owner's issue point to the place of installation with contractor's own lifting and transportation arrangement, filling/topping up with electrolyte, assembling, alignment, levelling, grouting, assembly of battery rack/stand, fixing of inter-cells connections, interconnection between battery bank & UPS/ Battery Charger/equipment, fixing of all loose accessories, supply of foundation bolts (if required), civil material etc. including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-charge. Any assistance as required by MANUFACTURER's supervisor at Site during the above activities is also included in the scope. Also any assitance required to Client for CEA approval shall be in Contractor's scope.

-

-

-

... More
Nickel-cadmium battery banks ,110 V DC , range from 800-1000Ah capacity.

6

-

-

... More
Nickel-cadmium battery banks, 110 V DC , range from 401-600Ah capacity.

8

-

-

... More
Nickel-cadmium battery banks , 110 V DC , range from 301-400Ah capacity.

8

-

-

... More
Nickel-cadmium battery banks , 110 V DC , range from 201-300Ah capacity.

2

-

-

... More
Nickel-cadmium battery banks , 110 V DC , range from 101-200Ah capacity.

4

-

-

... More
Nickel-cadmium battery banks , 110 V DC , range from 50-100Ah capacity.

6

-

-

... More
INDUCTION MOTORS: Testing, commissioning and checking of all interface connections of following ratings of motors installed by others. change of grease, wherever required including supply of approved type of grease, no load / full load running of motors, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-charge. Motor shall be tested for insulation value, winding resistance etc. If the insulation value is found to be low, it shall be improved by heating by means of external heater or by low voltage injection locked rotor method. Motors shall be run on no load for eight hours and hourly readings of current, temperature etc. to be recorded. After no load run test motor shall be run on load under specific instruction of the Engineer-in-charge. Ensuring direction of rotation of motor in line with requirement of driven equipment is contractor's responsibility. Load run parameters to be recorded. All tools, instruments required for the job are to be provided by the contractor. Also any assitance required to Client for CEA approval shall be in Contractor's scope.

-

-

-

... More
MV (415V) MOTORS

-

-

-

... More
Upto & including 3.7 kW

1

-

-

... More
3.7 kW to 15 kW

11

-

-

... More
18.5 kW to 37.0 kW

25

-

-

... More
45.0 kW to 90 kW

24

-

-

... More
110 kW to 160 kW

14

-

-

... More
MV Motors: During no load/full load running of MV motor, if the bearings are found defective, replacement of bearings including overhauling, removal of motor end shields, fans, removal of defective bearing, installation of new bearing, fixing back all the items removed from the motor, including supply of approved make bearings. If the motor is shifted from the site for the above job, then the contractor shall bring back the motor to site after bearing replacement, if the IR values are low, overhauling of motor, improvement of IR value using approved methods, boxing up the items removed from the motor, including any supply. If the motor is shifted from the site for the above job, then the contractor shall bring back the motor to site after IR value improvement, if motor flashover, winding failure, lead failure takes place, overhauling of motor, repair / rewinding of the motor as per the approved methods including all supply. If the motor is shifted from the site for the above job, then the contractor shall bring back the motor to site after repair/rewinding. The repair/rewinding shall done by motor OEM/authorised rewinders, including all labour and material, as per approved drawing, specification of this tender and direction of Engineer-in-Charge

1

-

-

... More
HV (6.6kV) MOTORS

-

-

-

... More
160 kW to 280 kW

7

-

-

... More
315 kW to 500 kW

7

-

-

... More
575 kW to 800 kW

3

-

-

... More
Above 1200 kW upto & including 2000 kW

1

-

-

... More
Above 2000 kW upto & including 3500 kW

1

-

-

... More
Above 3500 kW

1

-

-

... More
During no load/full load running of HV motor, if the bearings are found defective, replacement of bearings including overhauling, removal of motor end shields, fans, removal of defective bearing, installation of new bearing, fixing back all the items removed from the motor, including supply of approved make bearings. If the motor is shifted from the site for the above job, then the contractor shall bring back the motor to site after bearing replacement, if the IR values are low, overhauling of motor, improvement of IR value using approved methods, boxing up the items removed from the motor, including any supply. If the motor is shifted from the site for the above job, then the contractor shall bring back the motor to site after IR value improvement, and if motor flashover, winding failure, lead failure takes place, overhauling of motor, repair / rewinding of the motor as per the approved methods including all supply. If the motor is shifted from the site for the above job, then the contractor shall bring back the motor to site after repair/rewinding. The repair/rewinding shall done by motor OEM/authorized rewinders, including all labour and material, as per approved drawing, specification of this tender and direction of Engineer-in-Charge.

1

-

-

... More
FRP Canopies: Supply, Fabrication and installation of FRP Canopies for outdoor electrical motors of following ratings to render them weather proof, including supply of necessary hardware for fixing and clamping with the motor foundations /equipment, incuding all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-in-charge.

-

-

-

... More
Upto & including 3.7 kW

10

-

-

... More
Above 3.7 kW but upto & including 15 kW

10

-

-

... More
Above 15 kW but upto & including 37 kW

10

-

-

... More
Above 37 kW but upto & including 75 kW

10

-

-

... More
Above 75 kW but upto & including 125 kW

10

-

-

... More
Above 125 kW but upto & including 160 kW

10

-

-

... More
Above 160 kW upto & including 400 kW

10

-

-

... More
Above 400 kW upto & including 800 kW

10

-

-

... More
Above 800 kW upto & including 1200 kW

10

-

-

... More
Above 1200 kW upto & including 2000 kW

10

-

-

... More
Above 2000 kW upto & including 3500 kW

10

-

-

... More
Above 3500 kW

10

-

-

... More
Supply, Fabrication and installation of FRP Canopies for outdoor electrical miscellaneous equipment such as lighting / power panels, distribution boards, junction boxes, local panels, push button stations etc. to render them weather proof, including supply of necessary hardware for fixing and clamping with the equipment, incuding all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-in-charge (Note : The below items is for MPMC supplied Equipment and For the Contractor supplied items the canopy shall be part of the Equipment itself, no separate cost will be provided)

-

-

-

... More
Lighting / Power panels

1

-

-

... More
Junction box

1

-

-

... More
Push button station

1

-

-

... More
Local Panel

1

-

-

... More
Communication equipment

1

-

-

... More
Local Control Stations

1

-

-

... More
ANCHOR FASTENERS: Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, incuding all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-in-charge.

-

-

-

... More
Anchor fastner 16 mm x 100 mm

1000

-

-

... More
Anchor fastner 12 mm x 100 mm

1000

-

-

... More
Anchor fastner 10 mm x 100 mm

400

-

-

... More
Anchor fastner 16 mm x 125 mm

1000

-

-

... More
Anchor fastner 12 mm x 125 mm

1000

-

-

... More
Anchor fastner 10 mm x 125 mm

400

-

-

... More
MISCELLANEOUS ITEMS SUPPLY AND INSTALLATION

-

-

-

... More
SAFETY EQUIPMENT: Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. -

-

-

-

... More
SHOCK HAZARD CHART

-

-

-

... More
Supply and installation of framed & laminated shock hazard chart as per IE Rules 1956 (Clause-44) complete with aluminium frame and glass including necessary clamps, bolts, rawl plugs, etc. breachking and making good the wall if required, in three (3) language ie. English, Hindi & Assamese. Name, address and telephone number of nearest doctor shall be mentioned in it. All complete with labour and materials.

30

-

-

... More
RUBBER MAT: Supply and laying of 1000 mm wide safety synthetic insulating mat (pastable type) complying to IS-15652 latest edition, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines

-

-

-

... More
Rubber Mat 33 kV

3200

-

-

... More
RUBBER HAND GLOVES: Supply of following items as per applicable Indian standards/CEA Guidelines. Supply of the items and all the associated accessories of reputed make. Make shall be approved by Owner / Consultant.

-

-

-

... More
Rubber hand Gloves (33 kV) seamless Handgloves with Test certificate as per IS 13774 latest edition and type test shall be submitted

30

-

-

... More
CAUTION BOARD

-

-

-

... More
Supply and installation of "Caution Boards" 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required, with three (3) language ie. English, Hindi & Assamese.to be installed in electrical rooms such as transformer bay, switchgear room etc.at sub-stations as per IS2551/upto date including supply of necessary clamps, nuts, bolts and other hardware. All complete with labour and materials as per the direction of the Engineer-in-Charge

75

-

-

... More
INSULATION COATING: Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge . Dielectric flooring ,Standard shall be as per IS 15652 Latest edition and Break down voltage test should be approved by ERDA / CPRI and Electric stength as per IS :2584 latest edition. (Method Statement for ensuring thickness of coating to meet the required BDV criteria to be provided for approval.)

-

-

-

... More
For system voltage of 33 kV

4000

-

-

... More
GENERAL ITEMS Supply & installation of following items and all the associated accessories of reputed make. Make shall be approved by Owner / Consultant, all supplied material shall be industrial grade, ISI certified.

-

-

-

... More
Single Line Diagram's (SLD) for Substations shall have flex printing of size 10ft x 8 ft with metallic frame installed on the standing metallic supports.

30

-

-

... More
Face shield

20

-

-

... More
Arc Suite (PPE) 40 CAL / cm2 Make: THORNE & DERRICK & Honeywell The offered equipment shall be equivalent or better than Model no. INSK40L 33kV voltage grade of M/s. Honeywell make.

5

-

-

... More
First aid information chart (for electrical hazards such as Shock treatment)

30

-

-

... More
Discharge rod with earthing facility (upto 33 kV grade)

10

-

-

... More
First Aid boxes as per the Assam Factories Rules to be fixed on the wall using suitable wall mounting brackets

30

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Digital Multimeter Make : FLUKE / MEGGER / KYORITSU Industrial Grade / True RMS Meter 1. 1000V AC/DC; 10A AC/DC (with test leads and current jacks); resistance to 50 MΩ; capacitance to 10,000 μF, frequency to 100 kHz; temperature from -40 ℃ to 400 ℃ 2. Manual and automatic measurement ranging, Display Hold, Auto Hold, and Min/Max- Average recording. 3. Backlit digital display Model Ref : Fluke 179 Digital Multimeter (or) higher model

6

-

-

... More
Digital clamp on meter (AC/DC) Make : Fluke / Kyoritsu Digital Clamp Meter shall be suitable to measure Current range upto 1000A DC & 2500A AC and shall be supplied with flexible current probe. Shall also have provision for measuring voltage upto 1000V AC & DC, frequency of upto 500Hz, resistance upto 60kΩ, 50mV dc measurement and 1000μF capacitance measurement. Instrument shall be supplied with standard leads and case. The offered testing equipment shall be equivalent or better than Model no : Fluke 376 of M/s. Fluke make.

6

-

-

... More
Digital Insulation tester 500V – 10kV with provision for PI Make : Megger / Fluke Insulation tester shall be suitable for conducting insulation test on high-voltage equipment including switchgear, motors, generators and cables. Testing voltage shall be selected in steps from 500V to 10kV. Insulation tester shall be supplied with Standard leads & Case. Following features has to be considered as minimum : 1. Large digital/analog LCD for easy viewing. 2. Capacitance and leakage current measurement 3. Resistance measurements up to 10TΩ. 4. PI, DAR, DD, SV and ramp test. 5. Time/Date stamp. CATIV 600 V safety rating on all terminals. The offered testing equipment shall be equivalent or better than Model no : S1-1068 of M/s. Megger make.

2

-

-

... More
Earth Resistance Testers with all accessories Make : Megger / Fluke The offered equipment shall be equivalent or better than Model no. DET2/3 of M/s. Meggar make.

2

-

-

... More
HT line tester for voltage upto 33kV & HV Tapes Make : Megger / Kyoritsu / Fluke The offered equipment shall be equivalent or better than Model no. CC-363-K of M/s. CATU make.

6

-

-

... More
Tong tester (30mA-60mA) Make : Fluke / Kyoritsu The offered equipment shall be equivalent or better than Model no. 376 of M/s. Fluke make and shall be AC / DC

6

-

-

... More
Implementation of LOTO system during precommissioning & commissioning stage .

1

-

-

... More
Self contained portable hand lamp, complete with rechargeable battery.

6

-

-

... More
Portable battery operated emergency light.

6

-

-

... More
Battery impedance tester Make: Megger / Fluke The offered equipment shall be equivalent or better than Model no. BITE 2P of M/s. Meggar mak

2

-

-

... More
Insulated step ladder (FRP) of reputed make (suitable for indoor work in switchgear rooms)

6

-

-

... More
Lux Level Meters for illumination check Make: Fluke The offered equipment shall be equivalent or better than Model no. 941 of M/s. Fluke make.

3

-

-

... More
Tachometers (Non-Contact type) Make: Megger / Fluke The offered equipment shall be equivalent or better than Model no. 931 of M/s. Fluke make.

6

-

-

... More
Phase Sequence Meters Make: Megger / Fluke The offered equipment shall be equivalent or better than Model no. PSI410 of M/s. Meggar make.

6

-

-

... More
Allen keys Make: Taparia

6

-

-

... More
Electrical Tool Kit including Spanners / Torque Wrenches / Screw Drivers / Pliers / Cutters / Knives, Crimping Tools for Cable Lugs

6

-

-

... More
ARTIFICIAL RESPIRATION SYSTEM

6

-

-

... More
Tarpaulin (for weather protection of stored electrical equipment)

1000

-

-

... More
Transformer Oil Filtration Plant / Machine with Online PPM, Trolley mounted complete with all accessories. Capcity : 6000 LPH (Liter / Hour) MAKE : CEE DEE VACUUM EQUIPMENT PVT LTD

2

-

-

... More
Discharge Rod for 220KV Voltage (Maximum system voltage 245KV).The material used of sticks shall be type tested and BDV & other test shall be performed in Govt Approved Test House like CPRI ERDA, NPL etc as per IS 16622 latest edition.Material shall be supplied along with type test certificate Make : Agni / Kusam-Meco

10

-

-

... More
Supply of ferrule sleeves of 4.5mm and 3.2mm + label printing machines.

4

-

-

... More
Cable crimping machine ( upto 1000 sq.mm cable size)

4

-

-

... More
Knockout Punch Set includes six different size knockout punches and dies, two draw studs and ratcheting box end wrench

4

-

-

... More
Letter punching sets for cable tagging

6

-

-

... More
Fire buckets with stand containing 3 buckets per stand with lid and canopy

60

-

-

... More
4-20 MA Current Source / 4-20 MA Current Simulator With LED Display, For Industrial application

4

-

-

... More
RFID Marker Locator, 8000 Marker records, Built in GPS Module, 1.5m Depth Range 4 X 20 Digit LCD Display for 134kHz Power Markers. RFID Marker locator provided complete with Marker Database software and cloud data storage service facility (unlimited data storage) Make : Komplex(Stanlay)/ 3M

4

-

-

... More
RFID based Electronic Cable/ Pipe Marker 220mm +/-10mm Dia, 1.5m Depth Range, 10 Digits Hexadecimal 1D Code, 134.0KHZ Frequency Make : Komplex(Stanlay)/ 3M

200

-

-

... More
Secondary Injection test kit Make : Omicron Model :CMC 356

1

-

-

... More
Supply of Industrial type Laptop compatability to protection relays software configuration.Windows 10 operating system, Intel i9 processor, RAM 32 GB, Internal drive 500GB SSD, Integrated: Intel® UHD Graphics, Interfaces with 1 Ethernet port,2 USB ports, Built in WIFI,15.0 inch diagonal, Battery charger, Carry case, Integrated Audio with Inbuilt speakers, External USB DVD Drive, Power supply 230v AC

4

-

-

... More
LETTERING AND STENCILING

-

-

-

... More
Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, tray segment etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Each alphabet/character upto 2 inch in height/length - with fluorescent paint

1500

-

-

... More
Each alphabet/character above 2 inch and Upto 4 inch in height/length - with fluorescent paint

1000

-

-

... More
Each alphabet/character above 4 inch and Upto 8 inch in height/length - with fluorescent paint

600

-

-

... More
Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz. light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors, field call stations, loud speakers, tray segment, etc. including supply of enamel paint, all hardware as required, supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge.

-

-

-

... More
Each alphabet/character upto 2 inch in height/length

1600

-

-

... More
Each alphabet/character above 2 inch and Upto 4 inch in height/length

300

-

-

... More
Each alphabet/character above 4 inch and Upto 8 inch in height/length

200

-

-

... More
Supply & Installation of 3 ply Lamicoid tag plates of appropriate size for various equipment, with White letters on Black background, as per the site requirement

50

-

-

... More
SEALING COMPOUND

-

-

-

... More
Supply of sealing compound (Bituminous tar or approved equivalent) heating and pouring of compound in the cable stuffing box of flameproof motors and providing effective cable sealing, including all labour and materials, specifications of this tender and directions of Engineer-in-charge (measurement of weight shall be made for sealing compound supplied)

30

-

-

... More
Supply and installation of water proof / fire proof material with minimum 3 hours rating for sealing cable entries inside the switchgear buildings, outside electrical equpment / panel termination (Like : motor termination, DG termination, Substation building, field terminations, etc.) of reputed make and as per Site engineer recommendation

75

-

-

... More
Making cut-outs in RCC slab/ wall upto a thickness of 400mm (taking all necessary safety precautions) by vibration-less spark-free mechanical means like core-cutting, wet cutting by diamond wall saw system at all depths & heights including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, disposal of unserviceable material, plastering & finishing the cut surfaces, all complete as specified and directed by the Engineer-in- Charge (Measurement on Plan/ Elevation Area basis).

15

-

-

... More
Fire proofing of cables, to meet OISD requirement (for 3 mtr. length near terminations), for indoor and outdoor equipment cable termination, including supply of all fire proofing paint, including all labour and materials, specifications of this tender and directions of Engineer-in-charge (Actual area of surface painted shall be measured).

700

-

-

... More
MANPOWER RATE: Providing technical assistance during pre-commissioning / commissioning of unit (excluding items where precommissioning / commissioning in the scope of contractors) phase by deploying different categories of manpower as listed below after getting necessary aproval from EIC/MPMC/NRL.The quoted manmonths rates shall be inclusive of all wages, overtime for working beyond normal hours including holidays / weekly off, travel / accommodation expenses, including PPE’s, all tools & tackles etc and other costs which the bidder shall be entitled to claim by way of Man-Month Rates for the services. Prior to deployment of personnel at site, Contractor shall submit the detailed CVs of such persons proposed to be posted at site to Owner for concurrence & approval. The Owner and Contractor shall jointly maintain a record of all such personnel chargeable at Man-Month Rates deployed each day which shall be used as the basis for calculating payments due to the Contractor for the services covering assistance during pre-commissioning & commissioning phase. For deployment covering part of the month, payment shall be made on pro-rata basis considering 30 days in a month. Should the performance of any of Contractor’s personnel be found unsatisfactory by Owner, the replacement of such personnel shall be carried out by Contractor immediately

-

-

-

... More
Electrical Engineer

18

-

-

... More
Electrical Supervisor

18

-

-

... More
Technician/ Electrician

18

-

-

... More
Helper

18

-

-

... More
CEA/ STATUTORY APPROVAL SERVICES

-

-

-

... More
CEA and any other Statutory approvals for the Entire Electrical installation of Contractor SOW is under Contractor scope. Job includes arranging visit of officials, inspection. Preparation of drawings if any,liquidation of punch points by Inspectors, arranging Certificate & approvals all complete. The Base drawings as available with Owner shall be provided..(The prescribed fees for approvals & inspection if paid by Contractor shall be reimbursed by Owner against submission of Documentary Evidence).

1

-

-

... More
STRUCTURAL STEEL WORK

-

-

-

... More
ELECTRICAL SUPPLY & INSTALLTION WORKS: Supply, Fabrication, galvanising and installation of various sizes steel for supports, brackets for miscellaneous electrical equipment, base frames, support for switchgear, hangers, risers, clamps etc. for miscellaneous electrical equipment / items, cable and cable tray supports with rolled MS sections, pipes, plates, strip etc., including Blasting,supply of Paints & Painting including consumables,welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required, including supply of all G.I hardware materials, including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineer-In-charge. (Any item weighing up to 1 kg or less shall neither be measured nor paid.) structure,/ RCC structure/ platform / grade as the case may be. b) Supports shall be either welded or bolted to the permanent structures, for fixing supports on concrete structure HILTI Anchor's bolts shall be used. Minor civil work involved in the installation of the supports shall be also done the contactor including supply of cement, bricks,concrete, anchor bolts etc. c) If required during erection making of temporary supports / scafolding etc. is in contractors scope. d) Scope of work includes cutting, welding, threading, cleaning and other similar works involved in the fabrication of mounting stands and installation of junction boxes and its frame as per Installation standard. INSTRUMENT SUPPLY & INSTALLATION WORKS: Supply, Fabrication & installation of supports required for mounting IDF.The activity includes following works: Supply, fabrication and Installation of supports for the IDF ( Telephone Junctio box) or Junction Box. These supports shall be welded or bolted to the structures. Supports shall be made of Heavy duty galvanised mild steel (with 2 primer coatings & 1 epoxy coatings). Supply, Fabrication & installation of supports required for mounting junction boxes . The activity includes following works: a) Supports shall be suitable for installation on the plant permanent e) Design, Specification and Material shall be as per Installation standard TP-1ZZZA-IC-STD-0001. f) Supply of Structural Steel jointing fittings g) Support shall be painted (1 no. Primer & two coats of the paint & epoxy shall be applied). h) Scope of work includes supply of structural steel (i.e plates, flats, channels, angles, Tubular Structures etc of and other consumables i.e. welding electrodes, gas, primer, final paint. Erection contractor scope also includes welding, cutting, threading,cleaning, surface preparation for welding and painting and other similar works. i) When items requires tig welding qulaified person shall be employed to carryout described work providing required finish meeting all quality requirements i) Any other work not specified above but required for fabrication of structural steel is also in contractor's scope of work.

250.6

-

-

... More
Supply, fabrication and installation of 6mm thick M.S. chequered plates for covering / sealing floor cut-outs / cable trenches etc. including Blasting,supply of paints & Painting,cutting, grinding, fixing Lifting hooks in Chequered plates etc., including all labour and materials, complete as per approved drawings, specification of this tender and directions of Engineerin-in-charge.

3000

-

-

... More
Installation of Free issue Fabricated Steel support inside substations on Floor cut out for panel installation and in Cable vault for cable tray installation. Fabricated steel support installation at floor , brick, concrete wall , Celing etc. This may required minor modification of cutting, welding, blasting,painting of steel for proper installation.

10

-

-

... More
CIVIL WORKS

-

-

-

... More
Excavation and back filling of trenches for directlly burried cables and earth conductor in all type of soil except rock, for a max. depth of 1.5 M shoring, shuttering and dewatering / deoiling using pneumatic pump (if necessary) including consolidation and disposal of surplus earth outside refinery or as per direction of Engineering-in-charge, including all labour and materials complete as per approved drawings, specification of this tender and directions of Engineerin-in-charge. Trenches shall be duly rammed and levelled. (excavated trench dimensions shall be measured)

700

-

-

... More
Supply and filling /spreading of approved fine river sand in burried cable trenches and in RCC cable trenches including removal of RCC trench covers/slab, refixing of RCC trench Covers/Slabs after filling/spreading the sand, including all labour and materials complete as per approved drawings, specification of this tender and directions of Engineerin-in-charge.

300

-

-

... More
Supply and spreading / laying of concrete tiles of 75 mm thickness in buried cable trenches (for cable protection) including all labour and materials complete as per approved drawings, specification of this tender and directions of Engineerin-in-charge (actual area of laid brick surfaces shall be measured).

500

-

-

... More
Supply and spreading / laying of second class bricks of 75 mm thickness in RCC cable trenches (for cable protection) including removal of RCC trench covers/slab from RCC trench, refixing of RCC trench covers/Slab after laying of bricks, if required, including all labour and materials complete as per approved drawings, specification of this tender and directions of Engineerin-in-charge (actual area of laid brick surfaces shall be measured).

700

-

-

... More
Supply and laying of 40 mm size gravel in one layer of 100 / 150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge ( aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes).

400

-

-

... More
Supply and laying plain cement concrete for all depths below and up to plinth level in foundations including tamping, ramming, vibrating, cutting, shuttering etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed, including supply of all materials and all complete for concrete of M-15 grade with 20 mm and down size graded crushed stone aggregates, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge.

100

-

-

... More
CIVIL WORKS FOR FOUNDATIONS

-

-

-

... More
CONCRETE - R.C.C

-

-

-

... More
Supply and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE (Ready Mix Concrete with design mixes) with 20mm and down size graded crushed stone Aggregates / Gravel in SUB-STRUCTURE, using Ordinary Portland Cement/Portland Pozzolona Cement. E.g. Foundations,. pedestals, trenches, culverts, and other similar UG items etc.,including single pour concreting as specified on the drawing, applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating. tamping, curing and rendering if required to give a smooth and even surface etc.for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. For details refer specification for Plain and Reinforced concrete (NR-0ZZZZ-CV-SPE-0002). ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR

10

-

-

... More
SHUTTERING

-

-

-

... More
Supply and fixing CENTERING AND SHUTTERING in foundations, footings, raft, beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting. bracing, propping etc., keeping the same in position during Concreting and removal of the same after specific period etc. for Straight / Inclined Shuttering, keeping necessary provisions for Inserts, Projecting Dowels, Anchor Bolts or any other Fixture, tools, equipments and labour necessary for the work,etc., all complete and as specified and directed.

300

-

-

... More
REINFORCEMENT

-

-

-

... More
Supply and fixing in position TMT corrossion resistant reinforcement bars Fe500D conforming to IS-1786 (FY=500 MPa) for RCC work including the cost of steel and cost of binding wire, carting the same to site of work, straightening, cleaning, cutting, binding with 18 SWG black soft annealed binding wire, and placing with proper cover blocks, supports, chairs, spacers, complete for all heights and depths complete as per drawing & specification. Materials to be supplied as per approved vendor lists attached with special conditions of contract. For payment reinforcement including authorized weight for spacer bars, laps, chairs etc shall be measured separately for diameter wise length actually used. Wastages & unauthorized laps shall not be considered for payment.

2

-

-

... More
GROUTING: Providing and Application of Grouting for pocket, foundation / anchor bolts, sleeves, anchors of any shape, size, for any member, including roughening, cleaning & curing, etc. complete as directed by EIC.

-

-

-

... More
In CM 1:1 with addition of grit and as directed. (Cement Grout).

1

-

-

... More
With readymix anti-shrink grout as per manufacturer's specifications having strength 450kg/cm2

1

-

-

... More
With Epoxy grout as per manufacturer's specifications.

1

-

-

... More
RELOCATION / SHIFTING / RE-INSTALLATION

-

-

-

... More
Relocation / Shifting / Re-Installation of Existing High Mast including the existing LED fixtures(around 12LED fixtures), Feeder Pillar / MCB distribution box with earthing, lighting protections, glanding, termination of Incoming and outgoing Cables/ wires at luminaire and control gear box.

1

-

-

... More
Relocation and ReInstallation of Existing Street Lighting Pole, accessories and replacement of existing light fixture with 120W LED based street light fixture.

5

-

-

... More
Relocation / Shifting / Re-Installation of Existing HV/LV switch-boards, Electrical panels , Electrical Equipment, etc

-

-

-

... More
Shipping section / Unit weight from 101 kgs to 500kgs

5

-

-

... More
Shipping section / Unit weight from 501 kgs to 1000kgs

5

-

-

... More
Shipping section / Unit weight from 1001 kgs to 1500kgs

5

-

-

... More
Shipping section / Unit weight from 1501 kgs to 3000kgs

5

-

-

... More
Shipping section / Unit weight less than 100kgs

5

-

-

... More
DEMOLITION

-

-

-

... More
Demolition of existing High mast including the removal of Feeder Pillar / MCB distribution box, earthing, glanding, cables including associated foundations / structures, termination of Incoming and outgoing Cables/ wires at luminaire and control gear box and other accessories. This shall include shifting & storing of demolished high mast and the accessories to owner's provided place by contractor's own lifting & transporting arrangement, etc. as required, all labour and material complete and as per the directions of Engineer-in-charge.

1

-

-

... More
Demolition of Existing Street Lighting Pole including the removal of Feeder Pillar / MCB distribution box, earthing, glanding, cables including associated foundations / structures, termination of Incoming and outgoing Cables/ wires at luminaire and control gear box and other accessories. This shall include shifting & storing of demolished high mast and the accessories to owner's provided place by contractor's own lifting & transporting arrangement, etc. as required, all labour and material complete and as per the directions of Engineer-in-charge.

5

-

-

... More
Demolition of Existing HV/LV switch-boards, Electrical panels , Electrical Equipment, etc as below including the removal of earthing, glanding, cables including associated foundations / structures. This shall include shifting & storing of demolished items and the accessories to owner's provided place by contractor's own lifting & transporting arrangement, etc. as required, all labour and material complete and as per the directions of Engineer-in-charge.

-

-

-

... More
Shipping section / Unit weight from 101 kgs to 500kgs

5

-

-

... More
Shipping section / Unit weight from 501 kgs to 1000kgs

5

-

-

... More
Shipping section / Unit weight from 1001 kgs to 1500kgs

5

-

-

... More
Shipping section / Unit weight from 1501 kgs to 3000kgs

5

-

-

... More
Shipping section / Unit weight less than 100kgs

5

-

-

... More
REMOVAL / DISMANTLING ACTIVITIES OF EXISTING CABLES: Removal / Dismantling of existing cables in buried trenches of following sizes and shifting it to lay down area within plant as provided by the owner premises as per instructions from engineer in charge. Supply of consumables tools and Contractor shall use suitable vehicles for transportation, loading/ unloading. The activities may contain minor civil works like excavation, chipping, removal & handling of structural steels used for electrical items

-

-

-

... More
Removal of existing Cable of 11kV UE grade, Al Conductor, Armoured cable of following sizes

-

-

-

... More
1C x 630 Sqmm

300

-

-

... More
3C x 185 Sqmm

300

-

-

... More
3C x 300 Sqmm

300

-

-

... More
Removal of existing Cable of 11kV UE grade, Cu Conductor, Armoured cable of following sizes

-

-

-

... More
1C x 630 Sqmm

100

-

-

... More
Removal of existing Cable of 6.6kV UE grade, Al Conductor, Armoured cable of following sizes

-

-

-

... More
1C x 630 Sqmm

200

-

-

... More
3C x 120 Sqmm

200

-

-

... More
Removal of existing Cable of 1.1kV UE grade, Al Conductor, Armoured cable of following sizes

-

-

-

... More
3.5C x 50 Sqmm

300

-

-

... More
3.5C x 70 Sqmm

300

-

-

... More
3.5C x 95 Sqmm

300

-

-

... More
3.5C x 120 Sqmm

300

-

-

... More
3.5C x 150 Sqmm

300

-

-

... More
3.5C x 185 Sqmm

300

-

-

... More
3.5C x 300 Sqmm

300

-

-

... More
3C x 300 Sqmm

300

-

-

... More
Removal of existing Cable of 1.1kV UE grade, Cu Conductor, Armoured cable of following sizes

-

-

-

... More
2C x 2.5 Sqmm

300

-

-

... More
2C x 10 Sqmm

300

-

-

... More
3C x 2.5 Sqmm

300

-

-

... More
5C x 2.5 Sqmm

300

-

-

... More
7C x 2.5 Sqmm

300

-

-

... More
10C x 2.5 Sqmm

300

-

-

... More
Removal of existing Cable of 1.1kV UE grade, Annealed Tinned Copper Conductor, Armoured cable of following Annealed Tinned Copper conductor, PVC Insulated, Individual pair & Overall screened, PVC inner sheathed, Galanised Steel Flat Strip Armoured & Overall FRLS PVC outer sheathed Signal cable.

-

-

-

... More
3P2.5 Sqmm

200

-

-

... More
4P2.5 Sqmm

200

-

-

... More
6P2.5 Sqmm

200

-

-

... More
10P2.5 Sqmm

200

-

-

... More
12P2.5 Sqmm

200

-

-

... More
14P2.5 Sqmm

200

-

-

... More
REMOVAL / DISMANTLING ACTIVITIES OF EXISTING CABLE TERMINATIONS: Removal / Dismantling of existing cable terminations of following sizes. This shall include shifting & storing of demolished materials at owner's provided place (within plant premises) as per the directions of Engineer-in-charge.

-

-

-

... More
Removal of existing Cable termination of 11kV UE grade, Al Conductor, Armoured cable of following sizes

-

-

-

... More
1C x 630 Sqmm

20

-

-

... More
3C x 185 Sqmm

20

-

-

... More
Removal of existing Cable termination of 11kV UE grade, Cu Conductor, Armoured cable of following sizes

-

-

-

... More
1C x 630 Sqmm

20

-

-

... More
Removal of existing Cable termination of 6.6kV UE grade, Al Conductor, Armoured cable of following sizes

-

-

-

... More
1C x 630 Sqmm

20

-

-

... More
3C x 120 Sqmm

20

-

-

... More
Removal of existing Cable termination of 1.1kV UE grade, Al Conductor, Armoured cable of following sizes

-

-

-

... More
3.5C x 50 Sqmm

20

-

-

... More
3.5C x 95 Sqmm

20

-

-

... More
3.5C x 150 Sqmm

20

-

-

... More
3.5C x 185 Sqmm

20

-

-

... More
3.5C x 300 Sqmm

20

-

-

... More
Removal of existing Cable termination of 1.1kV UE grade, Cu Conductor, Armoured cable of following sizes

-

-

-

... More
2C x 10 Sqmm

20

-

-

... More
3C x 2.5 Sqmm

20

-

-

... More
5C x 2.5 Sqmm

20

-

-

... More
7C x 2.5 Sqmm

20

-

-

... More
10C x 2.5 Sqmm

20

-

-

... More
Removal of existing Cable termination of 1.1kV UE grade, Annealed Tinned Copper Conductor, Armoured cable of following Annealed Tinned Copper conductor, PVC Insulated, Individual pair & Overall screened, PVC inner sheathed, Galanised Steel Flat Strip Armoured & Overall FRLS PVC outer sheathed Signal cable.

-

-

-

... More
3P2.5 Sqmm

20

-

-

... More
4P2.5 Sqmm

20

-

-

... More
6P2.5 Sqmm

20

-

-

... More
10P2.5 Sqmm

20

-

-

... More
12P2.5 Sqmm

20

-

-

... More
14P2.5 Sqmm

20

-

-

... More
SUPPLY AND INSTALLATION OF FRP CABLE TRAY AND ACCESSORIES: Supply of FRP cable trays and accessories including transportation from manufacturer store/yard to NRL PROJECT site and unpacking, unloading at Owner's storage. Cable trays along with fittings, covers,.etc. complete with necessary splice plates, Cable Tray Hold Down Clamps, with required bolt, nut & washers as per standard drawings, specifications

-

-

-

... More
STRAIGHT RUN CABLE LADDER- FRP CABLE TRAY

-

-

-

... More
600(W) X 100(H) mm Straight Run Cable Ladder, each at 3m Long.

300

-

-

... More
300(W) X 100(H) mm Straight Run Cable Ladder, each at 3m Long.

75

-

-

... More
150(W) X 100(H) mm Straight Run Cable Ladder, each at 3m Long.

75

-

-

... More
STRAIGHT RUN PERFORATED CABLE TRAY- FRP CABLE TRAY

-

-

-

... More
100(W) X 50(H) mm Straight Run Perforated Cable tray, each at 3m Long.

75

-

-

... More
50(W) X 50(H) mm Straight Run Perforated Cable tray, each at 3m Long.

75

-

-

... More
CABLE TRAY COVERS - FRP including cover fixing clamp, nut bolt etc

-

-

-

... More
600 mm Wide Straight Run Cable Ladder Cover, each at 3m Long.

300

-

-

... More
300 mm Wide Straight Run Cable Ladder Cover, each at 3m Long.

70

-

-

... More
150 mm Wide Straight Run Cable Ladder Cover, each at 3m Long.

50

-

-

... More
100 mm Wide Straight Run Perforated Cable tray Cover, each at 3m Long.

50

-

-

... More
50 mm Wide Straight Run Perforated Cable tray Cover, each at 3m Long.

50

-

-

... More
90 DEGREE HORIZONTAL ELBOW - FRP CABLE TRAY

-

-

-

... More
90 Deg Horizontal Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

20

-

-

... More
90 Deg Horizontal Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

20

-

-

... More
90 Deg Horizontal Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm- Cover

20

-

-

... More
90 Deg Horizontal Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm- Cover

20

-

-

... More
90 DEGREE INSIDE VERTICAL ELBOW - FRP CABLE TRAY

-

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm, Cover

20

-

-

... More
90 Deg Vertical Inside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm, Cover

20

-

-

... More
90 DEGREE OUTSIDE VERTICAL ELBOW - FRP CABLE TRAY

-

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm

20

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 900mm Radius, 600(W) X 100(H) mm, Cover

20

-

-

... More
90 Deg Vertical Outside Bend, Ladder, 1200mm Radius, 600(W) X 100(H) mm, Cover

20

-

-

... More
CABLE TRAY SEPERATOR - FRP CABLE TRAY (3 mm thick)

-

-

-

... More
100mm Height Seperator

300

-

-

... More
INTRUMENTATION WORKS

-

-

-

... More
Scope of work includes installation after taking delivery from warehouse or from the places of storage, on site transportation, handling, storage, unpacking etc. The installation activity includes following operations: a) Contractor shall study the IDF or Junction Box location for possible interferences. b) IDF or Junction Box shall be installed on the basis of layout drawings provided by MPMC. Installation of Telephone IDF on the supports & all associated accessories ,Equipment erection, alignment and fixing shall be by contractor. Fabrication, installation and Touch up of all supports required & Masonry Works including Nuts/ Bolts etc. c) Minor civil work involved in the installation of the IDF or Junction Box support shall be also done by the contactor including supply of cement, bricks,concrete, anchor bolts etc. d) Signal and Power Cables installation for connection of devices up to the IDF or junction box and IDF or Junction box to cabinet including Gland installation. e) Spare cable entries of the IDF or Junction Box shall be plugged. Cable Termination coming /going out of IDF or Junction Box is in the scope of Contractor within the quoted price of this item. f) IDF or Junction Box body shall be grounded through external bolt provided on the Junction Box, single core PVC insulated copper wire shall be used for grounding (lugs & ferrules shall be supplied by the contractor). Grounding shall as per Project drawing. g) If required during Installation of IDF or Junction Box, making temporary supports / scafolding etc is in contractors scope of work. h) Adequate protection for IDF or junction boxes during installation and connection activities. i) After commissioning, all IDF or JB’s shall be covered with Aluminium tapes at its periphery to prevent water ingress. Supply of Aluminum tapes by Subcontractor. j) Supply, stenciling and Installation of Tag plate for IDF or Junction box as per Installation standard TP-1ZZZA-IC-STD-0001 k) Any other work not specified above but required for installation of IDF or Junction Box are also in contractor's scope of work. l) If required during installation of devices, making temporary supports / scaffolding etc. is in contractors scope of work. m) Any other work not specified above but required for installation of devices is also in contractor's scope of work n) Free Issue Item : Supply of IDF or Junction boxes , cable glands & plugs for spare cable entry.

-

-

-

... More
Installation of Ex-d Telephone IDF in field - 50P

5

-

-

... More
Installation of Building Indoor type Telephone IDF - 50P

5

-

-

... More
Installation of Ex-d Telephone IDF in field - 20P

4

-

-

... More
Installation of Building Indoor type Telephone IDF - 20P

2

-

-

... More
Installation of Ex-d JB at field analog phone end

61

-

-

... More
Installation of JB at Building analog phone end

23

-

-

... More
Supply & Installation of canopies for IDF in field: Canopies shall be of adequate size to protect the IDF from the sunlight and rain. Canopy shall be fabricated from 2 mm thick FRP sheet suitable for a design surface temp. of 65 C, Fire retardant to BS 476 parts 7. Anti- static to BS 5501 Part1. Contractor shall furnish drawing of the canopy along with offer. Fabrication of canopy shall be as per Installation standard "TP-1ZZZA-IC-STD-0001".Mounting accessories suitable for 2" pipe shall be supplied along with the canopy. Necessary SS 304 nuts & Bolts shall be supplied with bracket. Before starting the fabrication, contractor shall obtain the approval from Client/MPMC. Scope Includes but not limited to:-Supply, Fabrication & Installation of canopies of 2 mm thick FRP sheet on 2"/4" mounting stanchions for IDF.

9

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.