Numaligarh Refinery Limited Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Instrumentation Thermocouple And Earthing Cables Lot 1
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_NRL_781178_2Bid Award Id
ViewTender No
TP/082176C/NRL/PQ/123Tender Authority
Numaligarh Refinery Limited ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PART_I_COMMERCIAL_BID_DOCUMENTS
Part_II_Technical_Bid_Documents
Part_II_Technical_Bid_Documents
BOQ Items
... More
6Px2.5 IS Blue Flame Retd. LS PVC Arm Ovl shld
Cable code:E5-0.6/1.1-TTCOCO(C)-2.5(6P)IB
Cable Type:TYPE S21
1260
-
-
... More
1Px4 IS Blue Flame Retd. LS PVC Arm Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(C)-4(1P)IB
Cable Type:TYPE S85
525
-
-
... More
2Px4 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(I/C)-4(2P)IB
Cable Type:TYPE S86
893
-
-
... More
6Px1.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(I/C)-1.5(6P)IB
Cable Type:TYPE S17
31238
-
-
... More
12Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(12P)IB
Cable Type:TYPE S93
25883
-
-
... More
2Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(2P)IB
Cable Type:TYPE S96
6405
-
-
... More
6Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(6P)IB
Cable Type:TYPE S97
9188
-
-
... More
1Px1.5 IS Blue Flame Retd. LS PVC Arm Ovl shld
Cable code:E5-0.6/1.1-TTCOCO(C)-1.5(1P)IB
Cable Type:TYPE S1
525
-
-
... More
12Px1.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld
Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(12P)IB
Cable Type:Type S27
525
-
-
... More
LOT-2 - FLAME RETARDANT ARMOURED SIGNAL CABLES - NIS
Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame Retardant Low Smoke, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Non-Intrinsic safe as per MR.
Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%)
NRL MSL Category - 6.210 INSTRUMENT SIGNAL CABLE
-
-
-
... More
1Px2.5 NIS Black Flame Retd. LS PVC Arm Ovl shld
Cable code:E5-0.6/1.1-TTCOCO(C)-2.5(1P)NK
Cable Type:TYPE S4
3780
-
-
... More
2Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld
Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(2P)NK
Cable Type:TYPE S11
6090
-
-
... More
6Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld
Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(6P)NK
Cable Type:TYPE S18
32550
-
-
... More
12Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld
Cable code:E5-0.6/1.1-TTCOCO(I/C)-2.5(12P)NK
Cable Type:TYPE S30
16590
-
-
... More
2Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(2P)NK
Cable Type:TYPE S14
37485
-
-
... More
6Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(6P)NK
Cable Type:TYPE S20
27510
-
-
... More
8Tx2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(8T)NK
Cable Type:TYPE S95
12180
-
-
... More
1Px1.5 NIS Black Flame Retd. LS PVC Arm Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(C)-1.5(1P)NK
Cable Type:TYPE S2
525
-
-
... More
12Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld
Cable Code:E5-0.6/1.1-TTCOCO(I/C)-1.5(12P)NK
Cable Type:TYPE S28
525
-
-
... More
LOT-3 - FIRE RESISTANT ARMOURED SIGNAL CABLES - IS
Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Intrinsic safe as per MR.
Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%)
NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
-
-
-
... More
1Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(C)-1.5(1P)IRB
Cable Type:TYPE S43
16275
-
-
... More
12Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(12P)IRB
Cable Type:TYPE S71
3990
-
-
... More
1Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(1P)IRB
Cable Type:TYPE S45
3990
-
-
... More
6Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(6P)IRB
Cable Type:TYPE S61
31185
-
-
... More
12Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(12P)IRB
Cable Type:TYPE S67
31395
-
-
... More
6Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6P)IRB
Cable Type:TYPE S57
60060
-
-
... More
12Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(12P)IRB
Cable Type:TYPE S94
1470
-
-
... More
2Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(2P)IRB
Cable Type:TYPE S55
17640
-
-
... More
LOT-4 - FIRE RESISTANT UNARMOURED SIGNAL CABLES - IS
Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Unarmoured, Intrinsic safe as per MR.
Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%)
NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
-
-
-
... More
1Px1.5 IS Red+Blue Strip Fire Rest. LSZH UArm Ovl shld
Cable Code:E4-0.6/1.1-TTCXX(C)-1.5(1P)IRB
Cable Type: TYPE S80
2940
-
-
... More
LOT-5 - FIRE RESISTANT ARMOURED SIGNAL CABLES - NIS
Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Non Intrinsic safe as per MR.
Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%)
NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
-
-
-
... More
1Px1.5 NIS Red Fire Rest. LSZH Arm Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(C)-1.5(1P)NR
Cable Type: TYPE S44
17325
-
-
... More
1Tx1.5 NIS Red Fire Rest. LSZH Arm Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(C)-1.5(1T)NR
Cable Type: TYPE S48
2730
-
-
... More
1Px2.5 NIS Red Fire Rest. LSZH Arm Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(1P)NR
Cable Type:TYPE S46
42000
-
-
... More
1Tx2.5 NIS Red Fire Rest. LSZH Arm Ovl shld
Cable Code: E4-0.6/1.1-TTCXCX(C)-2.5(1T)NR
Cable Type:TYPE S91
945
-
-
... More
1Px4 NIS Red Fire Rest. LSZH Arm Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(C)-4(1P)NR
Cable Type:TYPE S87
5460
-
-
... More
12Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(12P)NR
Cable Type:TYPE S68
57435
-
-
... More
2Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(2P)NR
Cable Type:TYPE S52
75075
-
-
... More
6Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6P)NR
Cable Type:TYPE S58
17325
-
-
... More
6Tx1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6T)NR
Cable Type:TYPE S64
18743
-
-
... More
8Tx1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(8T)NR
Cable Type:TYPE S74
14543
-
-
... More
12Px2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(12P)NR
Cable Type: TYPE S70
15645
-
-
... More
6Px2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(6P)NR
Cable Type:TYPE S60
3570
-
-
... More
6Tx2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(6T)NR
Cable Type:TYPE S98
2625
-
-
... More
12Px4 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-4(12P)NR
Cable Type:TYPE S90
8715
-
-
... More
8Tx2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(8T)NR
Cable Type:TYPE S99
525
-
-
... More
LOT-6 - FIRE RESISTANT UNARMOURED SIGNAL CABLES – NIS
Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Unarmoured, Non Intrinsic safe as per MR.
Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%)
NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
-
-
-
... More
1Px1.5 NIS Red Fire Rest. LSZH UArm Ovl shld
Cable Code:E4-0.6/1.1-TTCXX(C)-1.5(1P)NR
Cable Type:TYPE S81
525
-
-
... More
1Px2.5 NIS Red Fire Rest. LSZH UArm Ovl shld
Cable Code:E4-0.6/1.1-TTCXX(C)-2.5(1P)NR
Cable Type:TYPE S82
11340
-
-
... More
12Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(12P)NR
Cable Type:TYPE S83
1260
-
-
... More
2Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(2P)NR
Cable Type: TYPE S84
21630
-
-
... More
6Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld
Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(6P)NR
Cable Type:TYPE S79
2415
-
-
... More
LOT-7 - FLAME RETARDANT THERMOCUPLE CABLE (K-TYPE)
Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame retardant Low Smoke Low Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured as per MR.
Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%)
NRL MSL Category - 6.213 - INSTRUMENT THERMOCOUPLE CABLE
-
-
-
... More
1Px16AWG Yellow Flame Retd. LS PVC Arm Ovl shld T/C-K
Cable Code:X4-0.6/1.1-TTCOCO(C)-16(1P)Y
Cable Type: TYPE S37
1995
-
-
... More
LOT-8 - FLAME RETARDANT EARTHING CABLE
Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame retardant Low Smoke Low Halogen, ST2 PVC sheathed, Unarmoured as per MR.
Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%)
NRL MSL Category - 6.210 INSTRUMENT SIGNAL CABLE
-
-
-
... More
1Cx6 Green+Blue Strip Flame Retd. LS PVC Unarm
Cable Code:E5-0.6/1.1-SC-6(1C)GB
Cable Type:TYPE E1
525
-
-
... More
1Cx6 Green+ Yellow Strip Flame Retd. LS PVC Unarm
Cable Code:E5-0.6/1.1-SC-6(1C)GY
Cable Type:TYPE E2
525
-
-
... More
1Cx6 Green Flame Retd. LS PVC Unarm
Cable Code:E5-0.6/1.1-SC-6(1C)G
Cable Type:TYPE E3
525
-
-
... More
1Cx2.5 Green+ Yellow+ Green Strip Flame Retd. LS PVC Unarm
Cable Code:E5-0.6/1.1-SC-2.5(1C)GYG
Cable Type:TYPE E6
43995
-
-
... More
1Cx10 Green+ Yellow +Green Strip Flame Retd. LS PVC Unarm
Cable Code:E5-0.6/1.1-SC-10(1C)GYG
Cable Type:TYPE E7
525
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements