Northeast Frontier Railway Tender

... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Northeast Frontier Railway - NFR Tender

Works
Civil And Construction
Construction Material
Electrical and Electronics
Consultancy Services
Civil And Architectural Services
Ireps
Opening Date28 Mar 2025
Closing Date21 Apr 2025
Tender Amount₹ 1,99,36,198.86 
Notes
Download

Costs

Summary

Augmentation And Replacement Of Electrical Asset Of Substation,railway Colony,coaching Depot ,power House Under The Jurisdiction Of Sse/p/scl & Sse/p/lmg.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply & fixing of GI angle of size 50X50x6mm clamped by GI flat 50x5mm with 50x16mm bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting .(2200 mm long bracket)

50

664

33248.5

... More
Supply & fixing of GI angle of size 50X50x6mm clamped by GI flat 50x5mm with 50x16mm bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting .(1500 mm long bracket)

-

-

5

... More
Supply & erection of 2P composite polymer 11 KV ball & socket type Disc insulator with minimum creepage distance 320mm & sectional length 300mm made of one piece injection 6 molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting

50

707

35384

... More
Supply & erection of 2P composite polymer 11 KV Pin insulator with minimum 7 creepage distance 340mm & sectional length 235mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting

90

512

46129.5

... More
Supply, stringing & binding of ACSR conductor, Weasel of size 6/1/2.59mm conforming to IS : 398-Pt.II-1976

4400

16

73700

... More
Supply & erection of Galvanised stay set for HT OH line comprising of 20 mm dia with 9 1.8 mtr long stay rod, anchor plate of size 30x30cmx6mm/45x45x7.5mm, turn buckle ( 20mmx600 mm), 20mm thimble , stay clamp, 7/10 mm dia GI stay wire, Guy strain insulator of size 85 x 140 mm for 11KV as per ref. IS 5300/1969, and cc foundation with ratio 1:3:6 including excavation, refilling etc.

35

939

32888.8

... More
Supply and drawing of guard wire by 8 SWG GI wire and cross lacing by 10 SWG GI wire. Cross lacing shall be provided not more than 1 meter interval.

1750

7

12390

... More
Supply & erection of 11 KV Air Break Gang operating switch 200amps. with 3 insulators rocking type double stack & handle including 25mm dia 3.25mm thickness GI pipe for linking 12

12

7343

88119.72

... More
Supply and erection of 11 KV DO fuse unit 200 Amps. channel type

12

4629

55554.6

... More
Supply and erection of 3 Nos Zinc oxide station Class-I Lightning arrestor with rated 13 voltage 30 KV ( RMS) with anormal discharge current rating of 10 KA and complete with galvanised clamping arrangement,GI bolts, nuts, washer as required conforming to IS : 3070-III-1993 suitable for 3 wire 33 KV line.

5

20522

102610.5

... More
Supply and erection of earthing by made of B class GI pipe of 3000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an 14 effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than 8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. As per Drg. No. DRG NO: PCEE/ELG/DRG/2024/1 dated 30.09.2024 & as per Technical circular no. EL/PS/2024/1 (EARTHING SYSTEM).

40

1581

63248

... More
Supply, installation, testing and commissioning of 2 nos., 800 Amp 4 pole off load change over with metal encloser

2

56915

113830

... More
Excavation of cable trench below the GL with laying of armoured cable and refilling 16 the same by supply of Brick, Sand and riddled Soil after digging the earth as per direction of Engineer at site & connection of armoured Cable by supply and fixing of crimping lugs etc. As per attached CEGE/NFR DRG NO: PCEE/ELG/DRG/2024/2 dated04.10.2024 & as per Technical circular no. EL/PS/2024/2 (Standardization of Drawing for power cable laying direct underground)

400

50

20020

... More
Supply and fixing of HDPE pipe of out side dia 110mm, 6kgf/cm2, 6.0 mtr each length and threaded to match with Tee, Elbow, Union and Socket etc conforming to IS 4984/1995 clamped with pole/truss/bracket made of galvanised flat of size 50x6mm with galvanised nuts & bolts of size 17 50x12mm as per direction of Engineer In Charge at site.

380

344

130815

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 18 aluminum conductors of different sizes (4 core 120 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site.

380

30

11571

... More
Complete dismantling and Uprooting (retrieving) of existing Rail pole /steel tubular/RSJ @40<47K47Z47s41@ lbs with its CC foundation by earth digging and filling the ditch after uprooting & finishing of surface as per direction of Engineer in charge at site

60

876

52569

... More
Supply & construction of fencing for substation of height 3.0 mtr above GL by 21 65x65x5mm MS angle MS. flatand 6swg GI wire mesh (4"x4"box) with making of gate by angle/flat with necessary welding of gate and fencing, painting of gate and fencing by one coat red oxide primer and two coat aluminum paint.(for five sub station total RM=50*5=250)

150

546

81931.5

... More
Supply,Installation,testing,and commissioning of floor mounted outdooe LT panel board consisting of 100 amp, 4 pole MCCB -2 nos.,100 amp change over switch -01 no. with 4 no. copper bus bar, ammeter, voltmeter, indicator, lamp etc.-----complete 1 set.

5

119915

599575

... More
Excavation of cable trench below the GL with laying of armoured cable and refilling 23 the same by supply of Brick, Sand and riddled Soil after digging the earth as per direction of Engineer at site & connection of armoured Cable by supply and fixing of crimping lugs etc. As per attached CEGE/NFR DRG NO: PCEE/ELG/DRG/2024/2 dated04.10.2024 & as per Technical circular no. EL/PS/2024/2 (Standardization of Drawing for power cable laying direct underground)

2300

50

115115

... More
Supply and fixing of HDPE pipe of out side dia 110mm, 6kgf/cm2, 6.0 mtr each length 24 and threaded to match with Tee, Elbow, Union and Socket etc conforming to IS 4984/1995 clamped with pole/truss/bracket made of galvanised flat of size 50x6mm with galvanised nuts & bolts of size 50x12mm as per direction of Engineer In Charge at site.

2300

344

791775

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 25 aluminum conductors of different sizes partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site.

4000

30

121800

... More
Complete dismantling and Uprooting (retrieving) of existing Rail pole /steel tubular/RSJ @40<47K47Z47s41@ lbs with its CC foundation by earth digging and filling the ditch after uprooting & finishing of surface as per direction of Engineer in charge at site

100

876

87615

... More
Supply,erection, installation & commissioning of 6 Mtr long Octagonal pole hot dip 28 galvanized minimum 65 micron zinc coating with sectional dia 70 mm (top),130 mm (bottom).overall sectional thickness 3 mm complete with base plate of size (220x220x12)mm, 4 nos 600 mm long foundation bolt of suitable dia along with pipe cap type pole bracket 1000 mm long double arm made with suitable cap pipe 48.3 mm,3.25 mm thick arms.Junction plate made of 6 mm thick Bakelite sheet with 4/6 amps SP MCB b curve & 4 nos end terminals to be mounted inside the base compartment of Octagonal pole. The work will also include supply and erection of PCC/RCC works for foundation of size 55 cm x 55 cm and depth 1 Mtr below GL and height 20 cm above GL in proportion 1:2:4 with stone chips of maximum aggregate size 20 mm and less including cement,sand & provision of 75 mm dia pvc pipe for cable entry with excavation of earth for foundation of all depth and all places,nature and condition of soil including de-watering,shoring, shuttering, batchning,mixing,placing,leveling,carrying,etc and refilling the pit after completion of foundation work from excavated earth or borrowed pit by contractors own arrangement for octagonal pole. (considering SBC of soil is 10 Ton/sq.Mtr)

40

6432

257298.4

... More
Supply, fitting, fixing, testing, installation & commissioning of 45 Watt outdoor type LED street light fitting made up of pressure die cast aluminum housing with high power LED as 29 lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. The street light must be conforms to the technical specification i.e. attached in the tender document. The whole work shall be executed as per direction of Engineer in charge at site. 30

70

3995

279659.1

... More
SITC of 100A busbar chamber capacities with 4 way Aluminium bus bar

90

11610

1044900

... More
supply, laying of heavy duty 1 inch(25mm) dia PVC pipe for drawing service connection.

1750

35

62125

... More
Supply and erection of earthing with earth pit by made of B class GI pipe of 3000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an 32 effective earth value.The connecting conductor from earth electrode to the distribution panel board should not be thinner than 8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. As per Drg. No. DRG NO: PCEE/ELG/DRG/2024/1 dated 30.09.2024 & as per Technical circular no. EL/PS/2024/1 (EARTHING SYSTEM).

10

1581

15812

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 33 aluminum conductors of different sizes (4 core 95 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site. (Cable will be supplied by Railway.)

290

30

8830.5

... More
" Supply, installation, testing & commissioning of 3 phase 0.433 KV/11 KV , 500 KVA 34 step up transformer copper wound with all associate accessories including construction of CC foundation and first filling of transformer oil etc. as per enclosed specification No.SDEE/GH/SPN/49 dtd. 04-12- 2006, IS 1180-2014 , BIS-level2 & the make of Transformer should be as per specification. "

1

721076

721076.64

... More
Supply, installation, testing and commissioning of 11 kV, 630 A, 26.3KA for 3 sec with spring charging motor rated for 230V AC, tripping coil and closing coil at 24 V DC with 630 A Aluminium Bus Bar - 1 NO., with potential transfromer of rating 11kV/R3/110 V/R3, CL 1/3P,50 VA - 3 nos. , & Current transformer 400-200/5-5A, CL 1/5P 10 10VA for each core - 3 nos. & Relays consisting of Numerical Protection Relay(50, 51, 50N, 51N)- 1 no., Master Trip Relay (86) - 1no., Trip Circuit 35 Spervision Relay(95) - 1 no., Auxiliary Relay fir transformer Protection (VA33)(63X) - 2 nos. & Meters of rating MFM wit RS 485 Port - 1 nos., Voltmeter + Ammeter(Digital Type) - 1+1 no.and Miscellaneous items like Fuse, MCB as per site requirement, 6 window Annuciator with Common hooter- 1 no., Plug & Socket - 1 no., L/R switch & TNC Switch - 1 no., Panel space heater assembly - 1 no., Indication lamp - 8 nos., Power pack(230 V AC TO 24 V DC) with 10 Min Back up - 1 no., Emergency Push Button - 1 no. The whole work shall be executed as per direction of Engineer incharge at site.

1

887500

887500

... More
Supply, and laying of 10 core 2.5 sqmm Flame Retardant XLPE insulated, Cores Laid Up, PVC Innersheathed, Armoured industrial grade multistrand copper conductor(Extruded PVC Type ST2 sheathed) flexible cable voltage grade upto1100 Volt.(Conforming to IS 694:2010)

90

990

89100

... More
Supply & erection of 11 KV Air Break Gang operating switch 200amps. with 3 insulators rocking type double stack & handle including 25mm dia 3.25mm thickness GI pipe for linking

3

7343

22029.93

... More
Supply & fixing of GI channel of size 75x40x40x6mm bracket of following size clamped with above pole made by GI flat 50x5mm with 50x16mm bolts, nuts for holding insulators, lightning arrester with necessary hole by drill including painting .(2200 mm long )

2

856

1713.52

... More
HDD boring Machine for horizontal boring in outside of the Road/Railway Track 39 Embankment at a minimumdistance of 6mtr from the enbankment GL and depth of 2.0 mtr below from GL with preparation of site for boring by placing of pipes for electric cable protection through contractors own arrangement. 40

230

6122

1408060

... More
Supply and laying of CI pipe 150 mm dia

230

4680

1076400

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 41 aluminum conductors of different sizes partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site. (Cable will be supplied by Railway.) 42

480

30

14616

... More
Supply,fitting,fixing of 11 KV HT termination kit for 3 core 120 sqmm cable

4

30050

120200

... More
Supply installation testing and commissioning of CPRI compliant 33 KV indoor type relay control panel suitable for Vacuum Circuit breaker of rated voltage 36 KV and rated current 1250A as per enclosed specification No. 3/SPEC/2005-06.

1

217763

217763.4

... More
Supply,Installation,Testing & commissioning of out door type structure mounted 44 ,porcelein clad,3 phase, 33 KV Vacuum Circuit Breaker of rated voltage 36 KV , continuous rated current 1250 A & short time current rating of 25 KA for 3 sec. complete with structure as per specification No. 2/SPEC/2005-06 conforming to IS : 13118 as well as instruction of Engineer incharge at site.

2

326645

653290.2

... More
Supply installation testing and commissioning of CPRI compliant indoor type relay control panel suitable for Vacuum Circuit breaker of rated voltage 12 KV and rated current 400A complete with supporting structure as per enclosed specification No. 7/SPEC/2005-06.

2

205452

410905.96

... More
Supply,Installation,Testing & commissioning of out door type Vacuum Circuit Breaker 46 of rated voltage 12KV, continuous current rating of 400A & rated short circuit breaking current 12.5 KA complete with provision of interlocking arrangement with supporting structure as per enclosed specification No. 6/SPEC/2005-06 including structure for mounting conforming to IS : 13118 (latest)

2

256816

513632.04

... More
Supply, installation, testing & commissioning of Horizontal mounting, 3Pole Double 47 Break Turn Twist Outdoor type isolator of rated voltage 36KV and continuous current of 1250A, ratecshourt circuit withstand current of 16KA on foundation as per enclosed specification No. 4/SPEC/2005-06 conforming to IS : 9921 (latest).

4

51642

206571.04

... More
Supply and erection of 3 Nos Zinc oxide station Class-I Lightning arrestor with rated 48 voltage 30 KV ( RMS) with anormal discharge current rating of 10 KA and complete with galvanised clamping arrangement,GI bolts, nuts, washer as required conforming to IS : 3070-III-1993 suitable for 3 wire 33 KV line.

3

20522

61566.3

... More
Supply and spreading of stone chips of size 20 mm and 100 mm thickness. The entire work to be executed as per direction of Engineer in charge at site.as per instruction of Site incharge.The whole work should be completed as per full satisfaction of Site incharge. The whole work shall be executed as per direction of Engineer in charge at site.

-

-

49

... More
Supply, fitting, fixing, testing & commissioning of 11 KV 400 amps GO-DO set with 50 operating handle and fixing of the same with pole by 2200 mm long MS channel ( 75x40x40x5) mm with ( 50x5) clamp with necessary nut/bolts.etc. The whole work shall be executed as per direction of Engineer in charge at site.

9

7200

64800.54

... More
Supply & erection of 11 KV Air Break Gang operating switch 200amps. with 3 insulators rocking type double stack & handle including 25mm dia 3.25mm thickness GI pipe for linking

18

7343

132179.58

... More
Supply and erection of 80 mm dia thickness not less than 4.0 mm, 4 mtr. long G.I.pipe 52 earthing including connection to transformer with G.I.Flats size 25x5mm including construction of earth pit, RCC earth cover slab 1/2" thick and earth continuity as per CEE/MLG's diagram CEE/STD/1.The whole work should be executed as per EIC at site

20

3153

63063.4

... More
Supply, installation, testing & commissioning of out door type structure mounted oil immersed, porcelain clad, 11KV Current Transformer two core (for both measuring & protection) of insulation level 32KV/75KVP, short circuit withstand current for 3 sec., 12.5KA of ratio 150- 75/5-5A, 53 protection secondary accuracy class -5P15 and measurement of secondary accuracy class -0.5 ( 1 set comprising of 3 Nos. CT) conforming to IS : 2705 (latest) along with supporting structure and first filling of required quantity and recomanded grade insulating oil and as per instruction of Engineer Incharge at site. (Note ; Tenderer shall decide burden of instrument transformer based on designed secondary load ( in VA) + 50% margin) .

2

141666

283332.94

... More
Supply installation testing and commissioning of 11 KV Potential Transformer outdoor 54 type, insulation level 32KV/75KVP, 11KV/O3/110V/O3/110V/O3, secondary winding accuracy class- 3P ( 1 set comprising of 3 Nos. PT) conforming to IS : 3156 ( latest) including first filling of required quantity and recomanded grade insulating oil along with supporting structure. (Note ; Tenderer shall decide burden of instrument transformer based on designed secondary load ( in VA) + 50% margin).

2

140115

280230.84

... More
Supply, installation, testing & commissioning of out door type structure mounted oil immersed, porcelain clad,33KV Current Transformer two core (for both measuring & protection) with 55 insulation level 70KV/170KVP, short circuit withstand current for 3 sec., 16KA, 50-25/5-5A, protection secondary accuracy class -5P15 and measurement of secondary accuracy class -0.5 ( 1 set comprising of 3 Nos. CT) conforming to IS : 2705 (latest) along with supporting structure including first filling of required quantity and recomanded grade insulating oil and as per instruction of Engineer Incharge at site .

2

130658

261316.74

... More
Supply installation testing and commissioning of 33 KV Potential Transformer outdoor 56 type, insulation level 70KV/170KVP, 33KV/O3/110V/O3/110V/O3. First secondary winding accuracy class - 0.5 and secondary winding accuracy class- 3P ( 1 set comprising of 3 Nos. PT) conforming to IS : 3156 ( latest) including first filling of required quantity and recomanded grade insulating oil along with supporting structure.

2

125781

251563.22

... More
Re-strengthening, supply, drawing and stringing of ACSR reccon conductor including binding and jumpering.

1500

28

42615

... More
Fabrication, design, supply, carrying and erection of 12 mtr height swaged type (410- SP-66) G.I. Tubular pole (including supply and fixing of base plate and pole cap) by earth digging to a depth of 1/6th of the pole height with CC foundation in ratio 1:2:4 by cement ,sand and stone of nominal size 20 mm & the size of the CC block will be 30 cm dia with height upto the pole depth below GL and 30 cm above GL for muffing. The pole shall be hot dip galvanized with an average 58 coating thickness of 70 microns conforming to IS:2629/IS:2633/IS:4759. The pole swaging, welding and base plate welding to be done as per IS:2713. The material construction(pipe) shall confirm to IS:1161/IS:1239 and shall be able to withstand maximum wind speed conforming to IS:875. Anti- climbing device by barbed wire upto 2.5 mtr height with necessary GI clamp/nut/bolts, etc has to be provided.Danger Board of size 8"X6" fixed with suitable GI clamp has to be provided showing the voltage grade,skull etc. The whole work shall be executed as per direction of Engineer in charge at site

18

27971

503493.12

... More
Supply & erection of 2P composite polymer 11 KV ball & socket type Disc insulatorwith minimum creepage distance 320mm & sectional length 300mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting

24

707

16984.32

... More
Supply & erection of 2P composite polymer 11 KV Pin insulator with minimum 60 creepage distance 340mm & sectional length 235mm made of one piece injection molded directly to high quality, corrosion resistant, fibre glass discharge rod and sealed to the hot dipped galvanised carbon steel end fittings by bead of silicon rubber complete with all accessories conforming to IEC : 1109 standard or as per IS : 731 (1971) & 2488 (Pt-II) 1974 complete with hardware fitting

25

512

12813.75

... More
Supply & erection of Galvanised stay set for HT OH line comprising of 20 mm dia with 61 1.8 mtr long stay rod, anchor plate of size 30x30cmx6mm/45x45x7.5mm, turn buckle ( 20mmx600 mm), 20mm thimble , stay clamp, 7/10 mm dia GI stay wire, Guy strain insulator of size 85 x 140 mm for 11KV as per ref. IS 5300/1969, and cc foundation with ratio 1:3:6 including excavation, refilling etc.

20

939

18793.6

... More
Painting of rail/tubular Pole with one coat of red oxide as Premier and finished with 62 two coats of Aluminum and black/red paint including angle iron, bracket, cross arm, clamps, nut-bolts etc complete in all respect as required with supply of Paint . The whole work shall be executed as per direction of Engineer in charge at site.

200

204

40862

... More
Supply & erection of danger board size 8"x6" on MS clamp made of 20x3mm for 33 KV showing the voltage grade,skull symbol etc.

50

48

2411.5

... More
Construction of CCwork(1:1.5:3) for concreteflooring inside 11KV Substationof thickness 100 mm of area 1500 sqft Theentire work to be executed asper direction of Engineer incharge at site. If any otheritems have been omitted butrequired it would beresponsibility of contractor tosupply and provide such items.However the quoted rate shallbe inclusive of those items.

1300

3235

4205513

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 65 aluminum conductors of different sizes (4 core 95 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site. (Cable will be supplied by Railway.)

891

30

27130.95

... More
Supply, fitting, fixing, testing, installation & commissioning of 45 Watt outdoor type LED street light fitting made up of pressure die cast aluminum housing with high power LED as 66 lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07. The street light must be conforms to the technical specification i.e. attached in the tender document. The whole work shall be executed as per direction of Engineer in charge at site.

55

3995

219732.15

... More
Supply, fitting, fixing and commissioning of 12 way vertical DB box having cut out fuse 32 amps x 12 nos.,Conforms to IS 8623-1&3, IEC 61439-1&3.

15

8655

129825

... More
Supply, fitting, fixing and laying of 90 mm Dia HDPE pipe along with all the 68 accessories like socket, bend, couplers etc. of working pressure of 6 Kgf per sq cm Conforming to IS 4984/1995,clamped with bracket wall thickness 7.6mm and threaded to match with GI pipe of Tee, Elbow, Union & Socket etc for laying of Welding line cable protection.

847

204

172872.7

... More
Supply,erection, installation & commissioning of 6 Mtr long Octagonal pole hot dip galvanized minimum 65 micron zinc coating with sectional dia 70 mm (top),130 mm (bottom).overall sectional thickness 3 mm complete with base plate of size (220x220x12)mm, 4 nos 600 mm long foundation bolt of suitable dia along with pipe cap type pole bracket 1000 mm long double arm made with suitable cap pipe 48.3 mm,3.25 mm thick arms.Junction plate made of 6 mm thick Bakelite sheet with 10 amps SP MCB c curve & 4 nos end terminals to be mounted inside the base compartment of Octagonal pole.The work will also include supply and erection of PCC/RCC works for foundation of size 55 cm x 55 cm and depth 1 Mtr below GL and height 20 cm above GL in proportion 1:2:4 with stone chips of maximum aggregate size 20 mm and less including cement,sand & provision of 75 mm dia pvc pipe for cable entry with excavation of earth for foundation of all depth and all places,nature and condition of soil including de-watering,shoring, shuttering, batchning,mixing,placing,leveling,carrying,etc and refilling the pit after completion of foundation work from excavated earth or borrowed pit by contractors own arrangement for octagonal pole. (considering SBC of soil is 10 Ton/sq.Mtr)

-

-

69

... More
Complete dismantling and Uprooting (retrieving) of existing Rail pole /steel tubular/RSJ @40<47K47Z47s41@ lbs with its CC foundation by earth digging and filling the ditch after uprooting & finishing of surface as per direction of Engineer in charge at site

40

876

35046

... More
Dismantling of unusable corroded ACSR conductor, Guard wire, brackets etc. and the same released materials in full quantity have to be deposited to the concerned Supervisor under challan after proper accounted bared on the CA

42

125

5262.6

... More
"Supply & erection of 33 KV Gang Operated Air break off load disconnecting isolator switch - 200/400Amp 3 pole rocking type each pole consist of galvanised steel base, HT insulators as 72 per BSS/ISS non ferrous knife and spring loaded contacts, arching horns of adequate sections to break magnetising current of the transformer horizontal Gi pipe of adequate length for phase separation and 25mm dia, 3.65mm thickness GI pipe of adequate length for operation from ground level and operating handle complete in both On & OFF positions."

3

31309

93928.56



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.