Northeast Frontier Railway Tender

... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Northeast Frontier Railway - NFR Tender

Works
Ireps
Kamrup - Assam
+6Sonitpur, AssamBiswanath, AssamBiswanath, AssamBiswanath, AssamSonitpur, AssamPapum Pare, Arunachal Pradesh
Opening Date20 Feb 2025
Closing Date21 Mar 2025
Tender Amount₹ 2,45,59,760.32 
Notes
Download

AI Insights

Bid Capacity
... View More
The bid capacity required in the given tender to bid having value and formulas is: Minimum average annual contractual turnover of V/N or "V" whichever is less, where V = Advertised value of the tender in crores of Rupees and N = Number of years prescribed for completion of work for which bids have been invited. Given the Advertised Value of the tender is 24559760.32 and the period of completion is 120 Days, we can calculate the bid capacity required as follows: V = Advertised value of the tender in crores of Rupees = 24559760.32 / 10000000 = 24.55976 N = Number of years prescribed for completion of work = 120 / 365 = 0.3288 (approximately) So, the minimum average annual contractual turnover required is: V/N = 24.55976 / 0.3288 ≈ 74.69 or "V" whichever is less, so the minimum average annual contractual turnover required is 24.55976. Therefore, the bid capacity required is: Minimum average annual contractual turnover of 24.55976 or 74.69 whichever is less. The formula for calculating the average annual contractual turnover is: Average Annual Contractual Turnover = (Total Contractual Payments in previous 3 years) / 3 Additionally, for composite works, the bid capacity required is: Costing not less than the amount equal to 60% of advertised value of each component of tender. The formula for this can be expressed as: Bid Capacity ≥ 0.6 * Advertised Value Where Bid Capacity is the minimum amount required to bid, and Advertised Value is the value of each component of the tender as advertised.
Technical Capacity
... View More
The required prior work experience for the bidder includes successfully completing specific categories of work within the last 07 years. The bidder must have completed: (i) Three similar works each costing not less than 30% of the advertised value of the tender, (ii) Two similar works each costing not less than 40% of the advertised value of the tender, or (iii) One similar work costing not less than 60% of the advertised value of the tender. In case of composite works, the bidder must have completed: (i) Three similar works each costing not less than 30% of the advertised value of each component of the tender, (ii) Two similar works each costing not less than 40% of the advertised value of each component of the tender, or (iii) One similar work each costing not less than 60% of the advertised value of each component of the tender. For subletting of work, the subcontractor must have successfully completed at least one work similar to the work proposed for subcontract, costing not less than 35% of the value of the work to be subletted, in the last 5 years. However, for subletting of work costing up to Rs 50 lakh, no previous work experience of the subcontractor is required. Additionally, the bidder should have a valid electrical contractor's license and a supervisory license issued by the State Government. The bidder should also have a qualified Graduate Engineer if the cost of the work is 200 lakhs or above, and a qualified Diploma Holder (Engineer) if the cost of the work is more than 25 lakhs but less than 200 lakhs. The bidder is required to submit a list of works completed in the last three financial years and a list of works on hand, indicating description of work, contract value, approximate value of balance work yet to be done, and date of award. The specific percentages and amounts of similar works completed are: - 30% of the advertised value of the tender for three similar works - 40% of the advertised value of the tender for two similar works - 60% of the advertised value of the tender for one similar work - 35% of the value of the work to be subletted for subletting of work - Rs 50 lakh for subletting of work with no previous work experience required - 200 lakhs for requiring a qualified Graduate Engineer - 25 lakhs for requiring a qualified Diploma Holder (Engineer)

Costs

Summary

At Rny Division - Provision Of Power Supply From Town Feeder Of Sebs In Lieu Of Rural Feeder To Railway Sub-stations At Ddni, Amga, Nmm, Tbh, Dbw, Gpz, Hml, Dkjr, Dql And Nhln Stations.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, fitting and fixing of G I. channel to be fixed on pole with suitable size GI clamp 04 made of 50X5 mm, GI flat with 50X16 mm bolts, nuts and washers etc. The channel to be painted by 2-coats of red oxide as primer and 2 coats of Aluminium paint as final coat of size - 75x40x40 x 5.0 mm, 2.5 mtr long as per direction of EIC at site.

150

966

144976.5

... More
Supply, fitting and fixing of G I. channel to be fixed on pole with suitable size GI clamp 05 made of 50X5 mm, GI flat with 50X16 mm bolts, nuts and washers etc. The channel to be painted by 2-coats of red oxide as primer and 2 coats of Aluminium paint as final coat of size - 75x40x40x 5 mm ,1.2 mtr long as per direction of EIC at site.

75

463

34787.25

... More
Supply, fitting and fixing of G I. channel to be fixed on pole with suitable size GI clamp 06 made of 50X5 mm, GI flat with 50X16 mm bolts, nuts and washers etc. The channel to be painted by 2-coats of red oxide as primer and 2 coats of Aluminium paint as final coat of size - 75x40x40x 5 mm, 6 mtr long as per direction of EIC at site.

70

2319

162350.3

... More
Supply, fitting and fixing of G I. channel to be fixed on pole with suitable size GI clamp 07 made of 50X5 mm, GI flat with 50X16 mm bolts, nuts and washers etc. The channel to be painted by 2-coats of red oxide as primer and 2 coats of Aluminium paint as final coat of size - 75x40x40x 5 mm, 3 mtr long as per direction of EIC at site.

60

1159

69579

... More
Supply, fitting and fixing of GI angle to be fixed on pole with suitable size GI clamp 08 made of 50X5 mm, GI flat with 50X16 mm bolts, nuts and washers etc. The channel to be painted by 2-coats of red oxide as primer and 2 coats of Aluminium paint as final coat of size -50x50x5 mm, 1.6 mtr long as per direction of EIC at site.

370

479

177307.7

... More
Supply, fitting and fixing of GI angle to be fixed on pole with suitable size GI clamp 09 made of 50X5 mm, GI flat with 50X16 mm bolts, nuts and washers etc. The channel to be painted by 2-coats of red oxide as primer and 2 coats of Aluminium paint as final coat of size -50x50x5 mm, 2.3 mtr long as per direction of EIC at site.

80

603

48276.8

... More
Supply, fitting and fixing of GI angle to be fixed on pole with suitable size GI clamp 10 made of 50X5 mm, GI flat with 50X16 mm bolts, nuts and washers etc. The channel to be painted by 2-coats of red oxide as primer and 2 coats of Aluminium paint as final coat of size -50x50x5 mm, 3.3 mtr long as per direction of EIC at site.

92

1254

115422.28

... More
Supply, fitting and fixing of GI angle to be fixed on pole with suitable size GI clamp 11 made of 50X5 mm, GI flat with 50X16 mm bolts, nuts and washers etc. The channel to be painted by 2-coats of red oxide as primer and 2 coats of Aluminium paint as final coat of size - 50x50x5 mm, 1.2 mtr long as per direction of EIC at site.

70

365

25577.3

... More
Supply, fitting and fixing of GI angle to be fixed on pole with suitable size GI clamp 12 made of 50X5 mm, GI flat with 50X16 mm bolts, nuts and washers etc. The channel to be painted by 2-coats of red oxide as primer and 2 coats of Aluminium paint as final coat of size - 50x50x5 mm, 2.5 mtr long as per direction of EIC at site.

92

777

71571.4

... More
Supply and erection of 3 nos zinc oxide line type distribution classI lightening arrestor 13 with rated voltage 9 KV (RMS) with normal discharge current rating of 5 KA and complete with galvanized clamping arrangement, GI bolts, nuts, washer as required confirming to IS: 4004 of 1985 suitable for 3-wire 11 KV line (3 nos in a set) as per direction of EIC at site.

22

1732

38112.58

... More
Supply, installation, commissioning and replacement of HT 11 KV GO switch 200 amps, triple pole and each pole consist of galvanized steel base, HT insulator for replacement of the existing G.O. for the feeders as per direction of EIC at site.

23

4700

108120.7

... More
Supply, installation, commissioning and replacement of HT 11 KV DO fuse (channel type) complete with all accessories for replacement of the existing G.O. for the feeders as per direction of EIC at site.

23

7534

173285.3

... More
Supply and handing over of 3 nos zinc oxide line type distribution classI lightening 16 arrestor with rated voltage 9 KV (RMS) with normal discharge current rating of 5 KA and complete with galvanized clamping arrangement, GI bolts, nuts, washer as required confirming to IS: 4004 of 1985 suitable for 3-wire 11 KV line (3 nos in a set) as per direction of EIC at site.

10

1400

14000

... More
Supply and handing overof HT 11 KV GO switch 200 amps, triple pole and each pole consist of galvanized steel base, HT insulator for replacement of the existing G.O. for the feeders as per direction of EIC at site.

10

3700

37000

... More
Supply and handing over of HT 11 KV DO fuse (channel type) complete with all accessories for replacement of the existing G.O. for the feeders as per direction of EIC at site as per direction of EIC at site.

10

6000

60000

... More
Supply and erection of galvanised stay set for 11 KV OH line complete with 20 mm dia, 1.8 mtrs long stay rod, anchor plate of size 23 cm x 23 cm x 6 mm thick, 16 mm dia turn buckle, thimble, stay clamp, 7/10 mm SWG GI stay wire & Strain insulator etc. in CC foundation with 1:3:6 ratio including excavation and refilling as per direction of EIC at site.

-

-

19

... More
Supply, installation and commissioning of 11 KV HT Polymeric pin insulator size 20 146mm, minimum failing load 5KN, Wet power freq 1 min, withstand voltage 35KV(RMS), Dry lighting impulse withstand voltage 75Kvp(+ve), including all accessories for fixing on the bracket with nuts, bolts & washers etc. as per IEC 1109, ISO 9001 : 2000. as per direction of EIC at site.

1660

288

478976.4

... More
Supply, installation and commissioning of 11 KV Polymeric Composite disc insulator 21 minimum creepage distance 450mm, section length 430mm, rated mechanical tensile load 70KN, Wet power freq 1 min, withstand voltage 48KV, Dry lighting impulse withstand voltage 100KV including all accessories for fixing on the bracket with strain clamps, nuts, bolts & washers etc. as per IEC 1109, ISO 9001 : 2000. (2 nos in a set) as per direction of EIC at site.

438

942

413006.26

... More
Supply and handing over of 11 KV HT Polymeric pin insulator size 146mm, minimum 22 failing load 5KN, Wet power freq 1 min, withstand voltage 35KV(RMS), Dry lighting impulse withstand voltage 75Kvp(+ve), including all accessories for fixing on the bracket with nuts, bolts & washers etc. as per IEC 1109, ISO 9001 : 2000. as per direction of EIC at site.

200

230

46000

... More
Supply and handing over of 11 KV Polymeric Composite disc insulator minimum 23 creepage distance 450mm, section length 430mm, rated mechanical tensile load 70KN, Wet power freq 1 min, withstand voltage 48KV, Dry lighting impulse withstand voltage 100KV including all accessories for fixing on the bracket with strain clamps, nuts, bolts & washers etc. as per IEC 1109, ISO 9001 : 2000. (2 nos in a set) as per direction of EIC at site.

100

750

75000

... More
Supply and erection of 50 mm dia 3 mtr long GI pipe for earthing thickness not less 24 than 3.6 mm including construction of earth pit, RCC earth cover slab 1/2" thick and earth continuity by G I strip (50x6)mm with GI nut bolts, earth resistance flag made of MS sheet of size 6''x4'' (with black back-ground & white readings on it ) etc as per direction of Engineer - in - charge at site. Drg ref no PCEE/ELG/DRG/2024/1 dated 30.09.2024.

245

1415

346822

... More
Supply and stringing of A.C.S.R (Weasel) of size 6/1/2.59 mm as per direction of EIC at site. [Confirming to IS:398:1996 (Reaffirmed 1997)]

50000

32

1605000

... More
Supply and stringing of guard wires by 8 SWG GI wire longitudinal and cross lacing at an interval of 1.5 mtr by 10 SWG GI wire as per direction of EIC at site - 8 SWG GI wire for longitudinal.

28500

6

179835

... More
Supply and stringing of guard wires by 8 SWG GI wire longitudinal and cross lacing at an interval of 1.5 mtr by 10 SWG GI wire as per direction of EIC at site - 10 SWG GI wire for cross lacing

24000

4

107760

... More
Laying of LT XLPE insulated armoured aluminium cables with suitable arrangements as per drawing no. PCEE/ELG/DRG/2024/2 Date: 04.10.2024.

1600

12

20656

... More
Excavation of trench of size 60 Cm width x 90 Cm depth for laying of G I pipe/HDPE Pipe/ cable with sand as required and filling of earth / ramming as required as per direction of EIC at site.

1600

13

22208

... More
Horizontal machine borring under National Highway at a depth of 2.0 mtr below GL including with required HDPE pipe (size of borring hole & HDPE pipe as per EIC) observing all necessary safety for human life and others movement as per direction of engineer at site.

200

5414

1082800

... More
Supply and fixing of outdoor type heat shrink type cable kit for 11000 volt grade, 120 sq mm single core Aluminium HT Cables (Similar to Model - EPKT 1560 of Raychem or Similar of M S Seal/Dension/3MT) as per EIC at site.

20

11550

231000

... More
Supply and handing over of outdoor type heat shrink type cable kit for 11000 volt grade, 120 sq mm single core Aluminium HT Cables (Similar to Model - EPKT 1560 of Raychem or Similar of M S Seal/Dension/3MT) as per EIC at site.

12

9240

110880

... More
Suply and fixing of outdoor type heat shrink type cable kit for 11000 volt grade, 240 sq mm single core Aluminium HT Cables (Similar to Model - EPKT 1560 of Raychem or Similar of M S Seal/Dension/3MT) as per EIC at site.

9

31550

283950

... More
Supply and fixing of HDPE pipe of outside dia 90 mm, 6 Kgf/cm2, 6 mtr each length confirming to IS:4984 / 1995,clamped with bracket by 50x5 mm MS flat clamp with nuts and bolts MS of size 50x12 mm for supporting of cable along pole as per direction of EIC at site.

700

371

259952

... More
Supply and erection of barbed wire upto height 1.5 mtr to be fixed on pole with 2 nos of clamps of suitable size and as per direction of EIC at site.

400

115

46057.33

... More
Supply and erection of danger board size 8"x 6" on MS clamp made of 20x3 mm for 11 KV showing the voltage grade, skull symbol etc as per direction of EIC at site.

375

31

11726.25

... More
Dismantling of existing 11kV LT OH line and handing over the materials such as railpole/tublar pole, ACSR, angles, channels and insulators etc with proper documents to EIC at site. (1 job = 1 span OH line ie Approx 40 mtr OH line)

115

1303

149948.5

... More
Supply and spreading of 40 mm pebbles with proper dressing in the switch yard as per instruction of site incharge of Railway. 39

30

1028

30864.19

... More
Supply & spreading of river sand (Earth filling) as per direction of EIC at site.

60

1008

60480.6

... More
Supply testing and handing over of hand driven Generator type four terminal alalog earth resistenace tester(range:0-10-100 ohm).Make should be of CIE 222M or equivalent in WACO/RISHAB/FLUKE/MECO/MOTWANE/METRAVI.

2

8212

16425.6

... More
Supply, testing and handing over of 2500V megger Insulation tester,insulation resistance range 0-10000 Mohm,metal body,hand driven Generator type with protection cover as per IS:2992 1987.Make should be of WACO/RISHAB/FLUKE/MECO/MOTWANE/METRAV only.

2

9201

18403.28

... More
Supply, testing and handing over of 500V megger Insulation tester,insulation resistance range 0-500 Mohm,metal body,hand driven Generator type with protection cover as per IS:2992 1987.Make should be of WACO/RISHAB/FLUKE/MECO/MOTWANE/METRAV only.

2

3115

6230.4

... More
Supply testing and handing over of 3.5 digit LCD hand held true RMS Clamp meter,measurung upto 1000 V AC/DC,100 A AC/DC, Make- WACO/RISHAB/FLUKE/MECO/MOTWANE/METRAV.

4

2975

11900

... More
Supply, testing & commissioning of AAAC MVCC covered conductor of size 50 sq. mm of voltage rating 11 KV AAAC MVCC covered conductor for overhead condutor as per direction of EIC at site. Make - KEI/Havell's/Apaar Industries

24000

148

3552000

... More
Supply ,installation & commssioning of Tension insulator for 11Kv single core 50 sq mm AAAC covered conductor as per direction of EIC at site.

100

1420

142000

... More
Supply installation & commissioning of Tension Hardware for 11Kv single core 50 sq mm AAAC covered conductor as per direction of EIC at site.

100

2360

236000

... More
Supply installation & commissioning of cable tie for 11Kv single core 50 sq mm AAAC covered conductor as per direction of EIC at site.

100

760

76000

... More
Supply installation & commissioning of Mid span jointing kit for 11 KV 1Cx50 sq mm AAAC covered conductor as per direction of EIC at site

40

2100

84000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.