BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Northeast Frontier Railway - NFR Tender

Works
Electrical and Electronics
Ireps
Opening Date20 Dec 2024
Closing Date13 Jan 2025
Tender Amount₹ 52,13,176.78 
Notes
Download

Costs

Summary

Modernisation Of Signalling Arrangement By Provision Of Electronic Interlocking At 3 Station (sarupathar, Barpathar & Bhilgaon) In Lmg-fkg Section Of Lumding Division (electrical Portion).

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of materials and wiring of 16 amps Modular type plug point through concealed wiring by 4 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire 4 through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 16 amps controlling switch(with indicator type) and 3 modular 16 Amps 6 Pin universal socket to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface.

60

374

22470

... More
Concealed wiring of modular type exhaust fan point/ Cal Bell pont in heavy gauge PVC 5 conduit pipe as per IS 9537 with PVC insulated single core 1.5 sqmm multistrand copper conductor wire in voltage grade 1100 volt as per IS 694 with ECC of 1/18 SWG Copper wire. controlling through flush type 10 Amp. switch to be fitted with frame and Tress Plate , as per the direction of engineer in charge at site.

30

390

11727.9

... More
Supply, erection, testing & commissioning of 300 mm sweep ventilating type air flow 6 exhaust fan suitable for single phase 230 volt AC supply including fixing arrangement by allied engineering works as per direction at site Engineer.. All consumables regarding fixing arrangement will be supplied by the contractor as per the direction of engineer in charge at site.

30

1269

38073

... More
Supply, fitting, fixing, connection & commissioning of 18/20 watt LED indoor fitting complete set with LED tube and other accessories. The fitting shall be connected by 1.5 sq mm flexible copper wire through pvc pipes/casing as required at site.

180

322

58111.2

... More
Supply, fabrication, erection of dust & vermin proof, rodent proof, chemically treated, 8 dry powder coated cubical Double-door panel board (for SZR,BXP,BHGN) made of 16SWG CR/MS sheet with electrolytic grade 4 pole 250A copper bus on suitable size MS angle frame complete with cable alleys, metering module with allinternal connection to be done by suitable size copper wire/strip connection .

3

105550

316650

... More
Supply and installation of MCCB 250 Amps 4pole 36KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IEC 60947-2 for item no 8.

6

34100

204600

... More
Supply and installation of MCCB 160 Amps 4pole 36KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IEC 60947-2 for item no 8.

6

20870

125220

... More
Supply & erection of MCCB 100 A, 4-pole, 25KA, Ics=100% Icu, conforming to IEC 60947-2 for item no 8.

6

12600

75600

... More
Supply & erection of MCCB 63 A, 4-pole, 25KA, Ics=100% Icu, conforming to IEC 60947-2 for item no 8.

12

12600

151200

... More
Laying, commissioning of LT/HT cable XLPE insulated power cables with armoured 13 aluminum conductors of different sizes (4 core 120 & 16 sqmm)partly along the pole and partly through ground in cable trench. Loading, unloading & carrying of cable to actual work site by contractor own arrangement as per instruction of Engineer in charge at site. (Cable will be supplied by Railway.)

6000

30

182700

... More
Supply, fitting, fixing and laying of 90 mm Dia HDPE pipe along with all the 14 accessories like socket, bend, couplers etc. of working pressure of 6 Kgf per sq cm Conforming to IS 4984/1995,clamped with bracket wall thickness 7.6mm and threaded to match with GI pipe of Tee, Elbow, Union & Socket etc for laying of Welding line cable protection.

500

204

102050

... More
Supply and laying of CI Pipe, (Class B),100 mm dia conforming to IS:1536/2001 with amendment No 1&3.

90

796

71647.2

... More
Excavation of cable trench below the GL with laying of armoured cable and refilling the same by supply of Brick, Sand and riddled Soil after digging the earth as per direction of Engineer 16 at site & connection of armoured Cable by supply and fixing of crimping lugs etc. As per attached CEGE/NFR DRG NO: PCEE/ELG/DRG/2024/2 dated04.10.2024 & as per Technical circular no. EL/PS/2024/2 (Standardization of Drawing for power cable laying direct underground)( for 4 core 120 & 16 sqmm cable.)

6000

50

300300

... More
Supply, Installation, Testing and Commissioning of of 63 mm of HDPE pipes of Grade PE-100, PN 6 (6Kg/Cm2 Capacity) with accessories as per IS 4984 - 1995

-

-

17

... More
"Supply, fitting, fixing, connection & commissioning of 3 KVA Sine wave digital inverter 18 with trolley, MOSFET-PWM technology, Input Single Phase sinewave(120v to 260V) Output Single Phase sine wave 230V Inverter EOciency (%)>/=87%, IP 21, conforming to IS:13314 or latestalong with valid BIS CRS certifications and 1 year warranty certificate. "

3

12395

37185.81

... More
Supply and testing of 150 AH , 12 V SMF Battery conforming to JISC: 8702/1998 (Part 1,2 & 3) with latest amendments having warranty of one years. All consumables regarding fixing arrangement will be supplied by the contractor as per the direction of engineer in charge at site.

18

14779

266022

... More
Supply, fitting, fixing, testing, installation & commissioning of 3 KVA online UPS of 20 technology IGBT-PWM(Sine wave). All consumables regarding fixing arrangement will be supplied by the contractor as per the direction of engineer in charge at site.conforming to IS:13314 or latestalong with valid BIS CRS certifications and 1 year warranty certificate. "

3

30000

90000

... More
Supply fitting fixing of 100Ah 12V Valve Regulated Lead -Acid Batteries for UPS (SMF) conforming to JISC: 8702/1998 (Part 1,2 & 3) with latest amendments

18

9500

171000

... More
Supply and erection of earthing by made of B class GI pipe of 3000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip ( should be welded with the earth pipe. The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring water during dry season to have an effective earth value.The connecting conductor from earth electrode to the distribution panel board 22 should not be thinner than 8 SWG GI wire to carry the fault current. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC and The values of earth resistance measured should be painted on the Earth pit cover/lid along with the date of measurement. As per Drg. No. DRG NO: PCEE/ELG/DRG/2024/1 dated 30.09.2024 & as per Technical circular no. EL/PS/2024/1 (EARTHING SYSTEM).

12

1581

18974.4

... More
Supply, testing, installation and commissioning of 1.5 ton, 5 star rating, split inverter type Air Conditioner complete system i.e. split unit, compressor,100 % copper condenser, copper tube, insulation material etc. Split Air Conditioner (Inverter Type, Variable Speed),Environmentally friendly refrigerant (R32, R410A, or equivalent),Evaporator Coil: Copper coil for better heat exchange 23 and corrosion resistance, Air Filter: Anti-bacterial filter, dust filter, and activated carbon filter,Noise Level: 40 dB (Indoor unit noise level),Condenser Coil: Copper coil with anti-corrosion coating, Compressor: High-efficiency rotary compressor, Surge Protection: High surge current protection on compressor startup, Overload Protection: Built-in thermal overload protection for compressor, Warranty: Minimum 1-year comprehensive warranty on the entire AC unit.Firm will be responsible for alllabour work including oneyears warranty of theequipment with 10 yearwarranty on compressor andtroubleshooting if any.(3 Nos AC for SM'S room (SZR,BXP,BHGN) 3 Nos spare AC.

12

35852

430231.56

... More
Supply and installation of 4/5 KVA, single phase, wall mounted voltage stabilizer for 1.5 ton split RAC. All consumables for fixing arrangement to be provided and executed by the firm as per the direction of Engineer in charge at site.

12

2510

30120

... More
"Design, supply, fitting, fixing, testing and commissioning of 25 A AC starteris to be fixed a Suitable Wall Mounted Electrical Switching Box, which will be fixed outside the Relay Room for the purpose of operating all ACs, from outside the Relay Room,Connection is to be drawn by single 25 core stranded FRLSH insulate 4sqmm, 1100volt grade copper cable confirming to IS- 694 through alkathene pipe of suitable size to be fixed inside wall by having final plastering with necessary coupler elbow /Tee /4way etc.The point to be terminated by modular type 25A AC starter onsuitable size modular G.I. box & platinum white plate at one endand by 25A DP MCB on MCB Distribution Boards with 1sqmmsingle core IS : 694 multistranded FRLSH copper wire as earth continuity at the other endas per direction of RailwayEngineer. "

6

622

3734.94

... More
Supply, fitting, fixing,connection, commissioning andwiring of AC point by goodquality accessories with properconnection complete with 16amps MCB and plug pointwiring by 6 sq mm single corePVC insulated flexible industrialunsheathed FRLSH copper wirethrough surface wiring 26 conduitpipe with earth continuity by 1sq mm single core PVCinsulated unsheathed flexiblecopper wire to be provided ongood quality modular plate andframe of suitable sizes andmounting box of proper sizes.(i.e thickness of mountingboxes of 3 mm and insidewidth of box should be 50mm). All other necessaryaccessories i.e PVC Tee, Bendetc will be supplied bycontractor.

6

532

3195.66

... More
Supply, Design, fabrication, fixing, testing & commissioning ofthermoplastic edge lit 27 LED lighting utility signage in by 10 mmacrylic sheet by engraving on a CNC laser cutting machine. 5 mmLamp LED's of adequate wattage to be used for edge lighting. Thepower supply should be backed up by battery supply of sealedLead battery of suitable capacity. Housing for power supply andbattery shall be made of profiled Aluminium duly anodized to giveweather protection. Degree of protection should be IP 65. (Size-2X2 Ft.= 4X30nos=120 Sq.Ft)

120

654

78500.4

... More
Dismantling of existing CLS panel and other accessories without damaging from the work site and Reinstallation as per instruction of site Engineer

3

876

2628.51

... More
Supply, Installation, Testing and Commissioning of of 63 mm of HDPE pipes of Grade PE-100, PN 6 (6Kg/Cm2 Capacity) with accessories as per IS 4984 - 1995.(For AT to CLS Panel Cable at SZR,BXP & BHGN)

3000

86

260220

... More
Excavation of cable trench below the GL with laying of armoured cable and refilling the same by supply of Brick, Sand and riddled Soil after digging the earth as per direction of Engineer 30 at site & connection of armoured Cable by supply and fixing of crimping lugs etc. As per attached CEGE/NFR DRG NO: PCEE/ELG/DRG/2024/2 dated04.10.2024 & as per Technical circular no. EL/PS/2024/2 (Standardization of Drawing for power cable laying direct underground)(For AT to CLS Panel Cable at SZR,BXP & BHGN)

3000

50

150150

... More
Design, manufacturing, supply,installation, testing andcommissioning of LED basedname boards in Hindi & English & Local language as per instruction of site incharge (Specification for LED basedname board). The board shall be as per enclosed specification.Note:- 01. 31 LED name boards fixing arrangement shall be included in the scope of workwith suitable size of M.S angle,nuts & bolts and foundation with 20 mm size stone aggregatewith cement & coarse sand etc.as required and LED based nameboards will be fixed along with wire mesh cage for protection of board from monkeys as perdirection of engineer in-chargeat site. 02. Name boards shouldbe in Hindi, English & Local languages. Board Size - 6 F x 4F = 24 Sq Ft.(Total approx 3 name board = 72 sq.ft.for (SZR,BXP,BHGN Rly Station,) The size andnomenclature of name board may change as per instruction of site incharge.

72

1231

88670.88

... More
Supply, erection, testing & commissioning of 3 phase, 11/0.433 KV, 100 KVA (Outdoor type Transformer), Dyn11 copper wound transformer with first filling of insulating oil( Conforming to IS 2026 or IS 1180 (Part 1) or IS 335 or other applicable standards.) complete set with all fittings and accessories including reconnection of all associated cables, ACSR conductor, etc & loading on 32 foundation pad for successful commissioning of Transformer. The transformer neutral connections are to be connected with two nos. copper strip of size (50x6) mm of adequate length and shall be connected by suitable Size/types of nut/bolts to the earth system. Body earthing of transformer shall also be done with two nos GI strip of size (40x6) mm & connected by suitable size/types of nut/bolts to the earth system. (All necessary materials required for successful commissioning of transformer on the pad shall be provided by the contractor).The entire work to be executed as per direction of Engineer in charge at site.OEM Test & warranty certificate shall be furnished.

3

170904

512713.29

... More
Fabrication, design, supply, erection and commissioning of CC foundation pad for transformer of size 2.5 mtrX3 Mtr and height 1.5 Mtr above GL and depth 0.75 mtr below GL with CC 33 in proportion 1:2:4 with stone chips of maximum aggregate size 20 mm and less including cement, sand etc. The entire work to be executed as per direction of Engineer in charge at site. If any other items have been omitted but required it would be responsibility of contractor to supply and provide such items. However the quoted rate shall be inclusive of those items

3

60709

182129.43

... More
Supply, instalation, testing and commissoning of dust and vermin proof, rodent proof, weather proof, chemically treated & dry powder coated LT outdoor rain shedded type floor mounted cubical panel board of made of CRCA sheet steel of 2 mm thick on suitable size MS channel/angle 34 frame with 400A, 4 pole, electrolytic grade copper bus bar complete with cable alleys and all internal connection to be done by suitable size copper bus strip/cable, cable alleys, metering module and The busbar chamber shall have three phase & neutral copper busbar of same ratings. The drawing of panel board should be approved by the competent authority before fabrication and commissioning. The panel shall be painted with two coats of primer & two coats of exterior coating by spray painting .

3

71000

213000

... More
Supply and installation of MCCB 400 Amps 4pole 50KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IEC 60947-2 for item no 34.

6

45600

273600

... More
Supply and installation of MCCB 250 Amps 4pole 36KA Ics=100%Icu with adjustable thermal magnetic setting confirming to IEC 60947-2 for item no 34

-

-

36



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.