Northeast Frontier Railway Tender
... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
AI Insights
Technical
Technical
Additional Eligibility
Bid Capacity
... View More
The formula for bid capacity is: Minimum average annual contractual turnover of V/N or "V" whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited.
Technical Capacity
... View More
The required prior work experience for the bidder includes contracting experience for the type of job for which tender is invited. The bidder should provide a list of works carried out in the past, along with testimonials. Additionally, certificates such as an attested Certificate from the client, Audited Balance Sheet duly certified by the Chartered Accountant, etc., regarding contractual payments received in the past, should be provided. The bidder must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender. (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender. (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender. The similar nature of work includes Smoke and Fire Detection and Alarm System for signaling installations at RRI/EI/PI stations or for Telecom installations in Indian Railways or in any other Govt./PSU Organizations.
Costs
EMD
₹ 2,75,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Safety Enhancement Of S&t Gears By Provision Of Automatic Fire Alarm System At 09 Stations Of Tinsukia Division
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
N-2024-25-TSK-T-26-TINSUKIA DIVISION-S AND T/N F RLYTender No
N-2024-25-TSK-T-26Tender Authority
Northeast Frontier Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
SITC Addressable input/output module with inbuilt isolator and shall have the LED indication for Normal, Fault test activation. The module shall have the option for configuration as fail safe operation and duly approved and as per RDSO/SPN/217/2021 Ver 3.0 or latest
40
12105
484200
... More
SITC of networkable 2 loops, microprocessor based, 2 wire fault tolerant module each 5 loop shall have the capability of connecting adequate number of devices- fire alarm control panel shall have built in degrade mode function- panel shall have in-built TCP/IP communication for panel program and remote monitoring option through LAN or WAN communication- panel shall have GSM interface for SMS generation- panel shall be able to give location of all fire and fire/fault and isolation condition of addressable units via the address code - panel shall have the capacity of storing upto 2000events. Panel must be able to automatically switch ON/OFF reapective control module whenever any alarm is tiggered- panel shall have a LCD/LED display and alphanumeric key board and analogue output external/in-built printer to log all fire or fault events complete in all respects panel shall have protection category of IP30 - panel shall have the option to operate in manned and unmanned mode- panel shall have a built in power supply and battery charger along with maintenance free of 24V battery capable of running for a minimum of 24 hours with battery charger- complete, as required and as per RDSO specification and duly approved and as per RDSO/SPN/217/2021 Ver 3.0 or latest.
10
250278
2502780
... More
SITC of Intelligent Addressable Aspiration type Smoke Detector - covers area up to 50 sq. meters with a programmable sensitivity range of 0.5 - 2% obs/m and duly approved as per RDSO specification No. RDSO/SPN/217/2021 Version No: 3.0 or latest - for Relay Room with A/C -includes SITC of following items: 1. Capillary Sampling Connector for capillary tubes, 2. Capillary tube 5.2mm 6 dia ID 8mm OD per meter, 3. Sampling point for capillary tube end, 4. sampling point label RED, 5. Trunk adaptor for capillary tubes, 6. Xtrails inline filter (grey) (external filter), 7. 25mm dia pipe for VESDA system NOTE: 1. Procurement of Automatic Fire Alarm System to be done from RDSO Approved Sources. 2. Scope of work includes provision of remote monitoring of Automatic Fire Alarm system at locations as per instruction of Engineer-in charge, issuance of OEM certificate, issuance of pre-commissioning check list (jointly signed with division) and impart of training (of duration as per instruction of Engineer-in charge)
52
224542
11676184
... More
Supply of industrial grade PC with operator VDU (42 inch) for networking as per technical specification 8
5
553896
2769480
... More
Supply & installation of fire extinguisher 4.5Kg capacity as per technical specification.
100
12037
1203700
... More
Supply and installation of LHS interface module as per RDSO/SPN/217/2021 Ver 3.0 or latest 10
15
69630
1044450
... More
Supply and laying of 2C X 1.5 sq mm LHS Cable, 1000V rated twisted 11
3000
254
762000
... More
Supply and installation of LHS cable as per RDSO/SPN/217/2021 Ver 3.0 or latest. 12
1000
1500
1500000
... More
Supply and laying of 25 mm dia GI conduit
2000
93
186000
... More
Installation, commissioning and testing of above Fire detection and alarm system at station
9
67152
604368
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%