Northeast Frontier Railway Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Northeast Frontier Railway - NFR Tender

Works
Civil And Construction
Excavation
Agriculture or Forestry Works
Ireps
Barpeta - Assam
+2Bongaigaon, AssamWest Garo Hills, Meghalaya
Opening Date24 Sep 2024
Closing Date21 Oct 2024
Tender Amount₹ 66,33,683.34 
Notes
Download

Costs

Summary

Restoration & Maintenance Of Telecomm Gears In Bg-i Section (dtx-pbl) And Bg-ii Section (nbq-rgji) Including Branch Line Ddni-mndp And Almg-bcmr Of Rangiya Division.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cable crossing of Railway track as per technical specs. by boring hole at a depth of 4 1.2 meter (nominal) by using 96/76mm dia HDPE pipe with accessories and restoring ballast to original condition. The work must be executed under the supervision of P.Way staff of the Railway, The work shall be executed as per technical specification detailed in Chapter III.

1000

275

275110

... More
Careful Digging of Trench of depth 0.5 mtr & width 0.3 mtr along the side of wall of ROB (Parallel to Track under ROB) without damaging the ROB wall or foundation.

1000

41

41820

... More
Protection of underground cable under ROB by provision of concrete 7 layer in the ratio 1:2:4 having minimum thickness 100 mm and minimum width of 200mm.

500

269

134860

... More
Laying PLB HDPE pipe size 33/40 mm, alongwith 6 Quad cable as per technical specification (Normal trenching)

3000

2

6270

... More
Fixing of Gl pipes (80 mm dia medium grade) including sockets/couplers MS angle MS flat Nuts, bolts etc on tunnel wall, bridges/culverts or other places for cable protection and concreting at ends with brick masonry at both ends with contractors own material as per technical specifications.

1000

340

340860

... More
Execution of galvanized iron trunking with cover of same materials as per DRG No.SGW/MGS/C7/9.Fitting of support at an interval of 1 Mtr, including laying of cables inside the trough and other materials as required for the work shall be supplied by the contractor

500

295

147675

... More
Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring for placing of 63 mm dia HDPE PIPE for crossing of 6 Quad and 33/40 mm dia HDPE PIPE for crossing of OFC cable together in one or more shot of suitable bore 10 size at bridges/ culverts / track/ pucca road crossing. Boring trench shall be minimum 3 (three) meter below the river bed and 1 (one) meter below the track / road/ pucca road crossing area. This includes supply of accessories for pulling HDPE pipes if any, cost of fuel and all other items which will be required for laying of cable through it. Supply of HDPE pipe is covered in schedule .The work shall be executed as per technical specification. Boring up to the length of 150 Mtrs

3000

812

2438880

... More
Pulling of Quad cable with Nylon rope through 63 mm HDPE pipes & backfilling of boring pit

1000

4

4210

... More
Pulling of OFC with Nylon rope through HDPE pipes of size 33/40 mm dia for 24 fibre armored OFC cable as per technical specification.

3000

3

10530

... More
Installation of Thermoshrink Jointing kit for 6 quad cable as per DOT/TEC specification with RDSO modification for straight through joints as per technical specification & site condition. Straight through thermoshrink jointing kit to be supplied by Railways.

100

869

86921

... More
Installation of O.F Cable joint enclosure and splicing of optical fibre cable as per direction of site supervisor.

100

418

41822

... More
Installation of earth electrode pipe as per technical specification. All required materials (3 meter long perforated G.I pipe size,50 mm dia, charcoal, normal salt, earthing lead,nut & bolts etc to be supplied by contractor.

100

1356

135682

... More
Digging of cable trench in normal soil including cutting & clearing of bushes and roots 16 of trees etc. up to a depth of 1 meter & width of 0.3 34 meter at the bottom for 20 pair PIJF cable in the section, and back Filling & ramming of soil in trenches to original level. The work shouid be done as per strict supervision of sectional site enginner.

1000

19

19590

... More
Installation of derivation joints at approx. every Kilometer for emergency sockets and LC Gates, from 6-quad cable, using PlJF cable, with the help of 2T Thermoshrink jointing kit and 2T VF transformer as per schedule.

100

1223

122366

... More
Installation of straight through jointing kit for 20 pair PlJF cable 0.5 mm dia. as per 18 RDSO code of practice for PIJF jointing using thermoshrink joints. Supply of Jointing Kit is covered in schedule. (However for any additional joint due to damage/theft of the cable during execution of Work thermoshrink jointing kit from RDSO approved sources will be Supplied by the contractor and installed free of cost)

50

599

29963

... More
Supply of permanently lubricated HDPE Pipe of size 33/40 mm 8(Nominal) along with sockets, as per RDSO Spec. No: RDSO/SPN/TC/45/2013 Rev 2.0 Amdt 2 or latest suitable for HDD.

3

29614

88843.98

... More
Supply of Gl pipes (80 mm dia medium grade as per IS-1239 or latest) including sockets/couplers MS angle,MS flat Nuts.bolts etc

1000

469

469030

... More
Supply of galvanized iron trunking with cover of same materials as per DRG No.SGW/MGS/C7/91 including supply of channel,angle iron,brackets unit,nuts and bolts of proper size.

500

762

381265

... More
Supply of permanently lubricated HDPE pipe of size 63mm dia (Outer Dia) as per specification no Spec.No:GR/CDS-08/02,Nov 2004 from the TEC approved firms suitable for HDD

1

129169

129169.25

... More
Supply of concrete Emergency socket posts, transportation to site, digging of pit and erection of emergency post complete with socket and socket boxes as per specification and drawings, 25 wiring, testing and commissioning of the emergency socket alongside the Railway track at locations indicated by site Engineer. The work shall be carried out as per Technical Specifications. Supply of Emergency socket box FRP type as per RDSO Drg.No.RDSO/SPN/TC/44/2002 Ver-2, Amd,2 will be supplied by Railways. 26

50

1615

80767.5

... More
Supply of Thermo shrink Jointing Kit for 6 - QUAD jelly filled cable as per spec. no. IRS:TC-77-2012 (Amendt -3 ) or latest for derivation 2-T joints. Items to be supplied in phases as per direction of SSE in charge.

100

1296

129630

... More
Supply of One QUAD' 2T VF transformer, impedance ratio 1120:470 as per specification No. IRS: TC - 22/76.Items to be supplied in phases as per direction of SSE in charge.

100

546

54669

... More
Supply of Straight through jointing kit (TSF-1) for 20 pair armored PIJF cable, 0.5 mm dia as per spec. No. RDSO/SPN/TO/57/2006 (Rev.0) Amdt- 1.

100

411

41122

... More
Supply and Installation of Maintenance Free Earth as per RDSO spec No:RDSO/SPN/197 Rev 1.0 as per TS.

5

35966

179831.85

... More
Supply of Monitoring Console Unit for configuration and updating of necessary data/information as per TS.

2

50042

100085.64



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.