Northeast Frontier Railway Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 5,21,200Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Provision Of Double Distant Signaling In Guwahati (ghy) -dharamtul (dml) Section Of Lumding Division
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
SNT-35-LMG-2024-25-LUMDING DIVISION-S AND T/N F RLYTender No
SNT-35-LMG-2024-25Tender Authority
Northeast Frontier Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Off set bracket for colour light signal Main unit, with fixing U clamps & nuts etc., as per RDSO Drg. No. SA 23080 (Adv.) or with latest amendments
30
1581
47444.4
Disconnect Terminal block for 4 (four) conductor (2 IN & 2 OUT) screw less with tin 5 plated knife edge type disconnect link as per RDSO Specification No. RDSO/SPN/189/2004 version 3.0, each conductor size up to 2.5 sq mm (with or without lug) 16 Amp rated current and each block shall be equipped with two markers on top and bottom, an end plate for each block, 2 end clamps & adequate length rails for fitting terminal blocks.
500
98
49230
Terminal block 1 Way made of PBT as per Specification No. IRS.S. 75/2006 (Rev.2) and drg.no. 23746 or with latest amendment/specification.
220
101
22242
FUSE BLOCK made of PBT/Polycarbonate as per IRS S 75/2006 (Rev.2) & Drg No SA- 23748 (Alt -4) or latest compatible to cylindrical end cap fuse link.
220
105
23306.8
16/0.2 mm size (0.5 sqmm) tinned flexible single core indoor wire IRS : S- 76/89 Amend. No. 3 or with latest amendment/specification, PVC coated in different colours as per technical specifications and to be supplied in coils of 100 meters.(a box=Coils of 100 mtrs)
80
729
58344.8
2.5 sqmm (36/0.30 mm dia ) PVC insulated unsheathed single core bright annealed bare copper conductor flexible cables for voltage grade upto 1100 v conforming to IS:694/1990 as per TS.(a box=Coils of 100 mtrs)
80
2432
194612.8
Supply of Apparatus Case (Large) as per RDSO Drg. No.RDSO/S-11500 or latest fitted with key lock (E-Type) with Key of ward No.11 . 12
12
17296
207557.88
Hylam sheet 1.22 m x 1.22 m as per TS.
30
3673
110205.6
AC Immune Plug-in-type QSPA1, DC slow to pick up, Neutral Line relay 24V DC, 8F-4B contacts, front and back contacts metal to carbon with plug board, retaining clip and connectors conforming to BRS:933A with interlocking pin code ABDEJ.
15
6102
91543.05
AC Immune Plug-in-type QNA1, DC Neutral Line relay 24V DC, 8F-8B contacts, front and back contacts metal to carbon with plug board, retaining clip and connectors conforming to BRS:931A with interlocking pin code ABDGH.
30
5286
158584.5
Supply of Relay, AC Immune, Plug in type style QNA1 DC neutral line, 24V, 12F-4B contacts. Front & back contacts metal to carbon, complete with plug board, retaining clip & connectors confirming to BRS 931A, IRS S 60, IRS S34, IRS S 23.
60
5286
317169
Under ground Railway Signalling cable 12 core x 1.5 sq. mm Copper Conductor PVC insulated Armoured Unscreened, Under Ground cable to spec. no. IRS:S-63/2014 (Rev.4) or latest
145
234820
34048900
LED signal lamps for main colour light signals "YELLOW" (Integrated type) for railway signalling, 110V AC, retrofitable in existing CLS housing and compatible with AC LED ECR as per RDSO specification No.RDSO/SPN/199/2010 Rev.1.0.
60
8968
538080
LED signal lamps for main colour light signals "GREEN" (Integrated type) for railway signalling, 110V AC, retrofitable in existing CLS housing and compatible with AC LED ECR as per RDSO specification No.RDSO/SPN/199/2010 Rev.1.0.
30
10207
306210
Universal Plug-in-type AC Lamp Proving Relay 110V AC, Metal to Carbon contact 4F.4B, style QECX as per specification No. BRS:941A & STS/E/Relays/AC Lit LED signal/09-2002 Amdt.1 or latest with plug board, retaining clip interlocking pin code ABDHK.
60
6490
389400
GI pipe Medium Grade (Class-B) 80 mm dia inside, wall thickness 4.0 mm as per IS: 1239 Part-I (2004) or latest.
1400
631
883750
Supply pad locks (NAV TAL) Godrej , 65 mm 7 levers - long shackle (2 keys) as per product code 3290, Bann code LKYLPN662 or latest all with common keys. 22
15
684
10266
MS Plate 35 x6 mm for perimetric earthing of Location Box
500
107
53950
Excavation of trench 1.2 mtr deep, 0.3 mtr wide at the bottom along railway track in 1 all type of soils (except rocky area), including clearing of bushes, trees, temporary obstruction, bailing out water from the trench etc. and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instruction of Engineer at site.
70000
70
4903500
Excavation of cable trench 1.0 Meter deep, 0.3 Mater wide on pucca platform / on 2 Road for road crossing and restoration of the platform/Road surface to original condition with contractor's material, after laying of DWC pipes and then re-filling the trench as per Technical Specifications.
3500
540
1892520
Excavation of trench 1.0 mtr deep, 0.3 mtr wide at the bottom along railway track in 3 rocky and ballast filled soil, including clearing of bushes, trees, temporary obstruction, bailing out water from the trench etc. and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instruction of Engineer at site. 4
1500
400
600390
Track Crossing as per TS
500
801
400575
Laying of Signalling / Quad / OFC Cables of various cores/pairs in trnch/GI /RCC /DWC HDPE pipes/trunking as per Technical specifications. 6
154000
4
736120
Execution of HDD boring as per TS
5000
1397
6989850
Excavation, ramming, Casting Cement Concrete foundation for Apparatus cases/Location boxes in the ratio of 1:3:6 Aggregate not exceeding 3 : 8 cm, as per Drg. No. CSTE's Drg. No. SK/12/00021 and technical specifications using standard size galvanized Anchor bolts & nuts 7 also referred to as foundation bolts conforming to IRS Drg No. SA-116 A/M for erection of apparatus case/location box , plastering with 1:4 cement sand mixture all the surface up to 75 mm below ground level complete with contractor's materials including cement , sand, stone, anchor bolts/nuts and curing of casted foundation, refilling and ramming of loose soil around foundation and disposal of digged soil from site.
-
-
138266.8
Installation of Apparatus cases/Location Boxes on CC foundation on grouted bolts, including filling the space enclosed below the location box with contractor's sand, as per technical specifications.
-
-
41480.04
Termination of cables including fixing of hylam sheet and supporting on string rod, with supply and providing identification tags/ferrules/tapes with letters on each cable conductor, as per technical specifications.
-
-
41480.04
Excavation, ramming, casting cement concrete foudation for colour light main signal post in the ratio of 1:3:6 aggregate not exceeding 3:8 cm, as per Drg. No. CSTE/CON/SK/05/99 and technical specifications using strandard size galvanized anchor bolts & nuts ( also referred to as 10 foundation bolts) conforming to IRS Drg. no. SA-116A/M, for erection of colour light signal post, plastering with 1:4 cement-sand mixture all the surfaces up to 75 mm below ground level, complete with contractor's materials including cement, sand aggregate anchor bolts and nuts and curing of casted foundation, refilling & ramming of loose siol around foundation and disposal of loose dugged soil from site.
28
11729
328429.08
Assembling, errection, installation, taking of cable inside unit through post, termination 11 and wiring of CLS complete with all accessories of CLS unit, post base, ladder, ladder guards, platform and MS supporting bracket in the middle of the ladder, hoods pinacles, offset brackets, Junction/stencil type route indicators (if any)-1 way to 6 way, etc including fixing & wiring of LED units lamps with contractor's wiring material.
-
-
256570.72
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6, aggregate not 12 exceeding 3 : 8 cm including excavation,raming, curing and plastering with 1 : 4 cement - sand mixture complete with contractor's material including cement, sand, aggregate and curing of casted foundation, refilling & ramming of loose soil around foundation and disposal of loose dugged soil from site.
10
3148
31480.4
Taking the all types of cables inside station relay rooms, location hut at both end and sealing of cable entry pit etc. as per Technical specifications, complete with contractors's material.
40
8118
324724.4
Termination of cables including fixing of hylam sheet and supporting on string rod, with supply and providing identification tags/ferrules/tapes with letters on each cable conductor, as per technical specifications.
40
1311
52440
Installation of earth electrode (pipe) as per technical specification. All required materials (3 meters long perforated G.I. pipe 50mm dia, charcoal, normal salt, earthing lead, nut & bolts etc. to be supplied by contractor).
28
1173
32856.88
Digital signal wiring of Data loggers between relay to intermediate tag block and intermediate tag block to Datalogger tag block in relay room and TLBI in ASM room including supply of flexible wire .
-
-
16
Validation, testing and networking of data loggers with additional inputs as per technical specification. 18
14
16987
237825
Supply and Installation of Signal number Plates as per Technical Specification.
14
825
11560.92
Design, preparation and supply of modified circuit/drawing like SIP, PD, RCC, CTR particulars etc as per TS.
14
250000
3500000
Modification in design of Electronic Interlocking system at station as per TS. 2
8
650000
5200000
Alteration in wiring, installation, testing and commissioning of EI at stations as per TS. 3
8
450000
3600000
Activity of FAT as per TS 4
8
230000
1840000
Supply of As Made document as per TS
8
75000
600000
Modification of existimg Domino panel (Deltron make) as per approved Front Plate Diagram along with supply of items as below including fitting, fixing & wirings.
-
-
208519.5
Modification of indoor wiring by Running of Indoor cables and carrying out jumpering as per approved circuit diagram at station including Fixing of relays & relay groups on relay racks & bases on anodised bar/relay base supporting strips, soldering in tag block terminals, relay bases 2 terminals and contacts clip, including supply of resin core solder of approved made for soldering, condensers, resistances, threads/self locking PVC clips & lugs, dressing, providing wires/cables on batons with clips/ladder for various functions & up to CT rack, terminal strip writing description of circuits on base plates, relays, power equipment, fuses, terminals etc. as wiring diagram with suitable colour paints as per standard practice and technical specifications with contractor's cements, sand, agregate etc wherever required.
6
186498
1118992.68
Testing and commisioning of complete signallig installtion at station/mid section 3 gate/hut, as per technical specifications and testing protocol including arranging simultation panel if required and testing indoor/outdoor gears through it, rack, lamps with holders, all instruments and apparatus as necessary for conducting such tests.
6
97875
587251.38
Complete indoor wiring at LC gate as per approved circuit diagram including installation of Gate Telephone, Hooter, EKT in glass fronted wooden box as per technical specification.
6
12716
76300.2
Design, preparation and supply of modified signalling Circuits of existing Route setting type as per the details given in the technical specifiction.
6
256152
1536914.82
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%