North Eastern Regional Institute Of Water And Land Management Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 16,100Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_NERIW_829135_1Tender No
NRWM/ELECT/14/2024-25/780Tender Authority
North Eastern Regional Institute Of Water And Land Management ViewPurchaser Address
-Website
http://http://neriwalm.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and laying 6 SWG G.I wire at 0.50 meter below ground level for conductor earth electrode, including connection/termination with GI thimble etc as required
80
-
-
Providing, laying and fixing following dia GI pipe (medium class) om ground complete with GI fittings including trenching (75 cm deep) and re-filling etc as required (i) 100 mm dia
12
-
-
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) (i)100 mm Dia
(ii) Class-I
2
-
-
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) (i) 100 mm Dia
(ii) Class-II
1
-
-
Cutting holes up to 30x30 cm in walls including making good the same:
(i) With common burnt clay F.P.S. (non modular) bricks
2
-
-
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
1
-
-
Supplying of following size of 1.1 KV grade multicore alluminium condutor PVC sheathed armoured cable as per IE 1554 (i) 3.5 Core 120 Sqmm XLPE Al Ar Cable
240
-
-
Supplying of following size of 1.1 KV grade multicore alluminium condutor PVC sheathed armoured cable as per IE 1554 (i) 3.5 Core 70 Sqmm XLPE Al Ar Cable
120
-
-
Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes direct in ground including excavation sand cushioning protection covering and filling the trench etc as required, (i) Size exceeding 35 Sqmm but not exceeding 95 Sqmm
120
-
-
Laying of one number XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following sizes direct in ground including excavation sand cushioning protection covering and filling the trench etc as required, (i) Size exceeding 95 Sqmm but not exceeding 185 Sqmm
240
-
-
Supplying and making end termination with brass comperession gland and alluminium lugs for following size of PVC insulated and PVC sheathed/XLPE alluminium conductor cable of 1.1 KV gland as required, (i) 3.50 Core x 70 Sqmm
18
-
-
Supplying and making end termination with brass comperession gland and alluminium lugs for following size of PVC insulated and PVC sheathed/XLPE alluminium conductor cable of 1.1 KV gland as required, (i) 3.50 Core x 120 Sqmm
18
-
-
Supplying and fixing cable route marker with 10cm x 10 cm x 5mm thick GI Plate with inscription there onb, bolted/welded to 35mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required
30
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
0.86
-
-
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (i) 80 mm dia
18
-
-
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (i) 65 mm dia
6
-
-
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (i) 50 to 80 mm nominal bore
1
-
-
Providing and fixing gun metal non- return valve of approved quality (screwed end) : (i) 80 mm nominal bore (Vertical type )
1
-
-
Providing and fixing of lightning conductor finial,made of 25mm dia 300 mm long, GI tube, having single prong at top, with 85 mm dia 6 mm thickG.I base plate including holes etc. complete as required.
2
-
-
Fixing the lighting conductor finial (single prong) with the base plate including holes etc. complete as required
2
-
-
Jointing copper/GI tape (with another copper /GI tap,base of the finial or any other metallic object) by roveting/nut bolting/sweating and soldering etc as required.
2
-
-
Providing and fixing GI tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
40
-
-
Providing and fixing G.I tape 20mm x 3mm thick on parapet or surface of wall for lightning conductor complete as required (For vertical run)
40
-
-
Earthing with G.I earth plate 600mm x 600 mm x6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long atc with charcoal or coke and salt as required.
1
-
-
Supplying and laying 32mm x 6mm G.I strip at 0.50 meter below ground as strip electrode, including connecion/terminating with G.I Nut-Boltspring, washer etc as required.(jointing shall be done by overlapping abd with 2 sets of GI nut bolt & spring washer spaced at 50mm)
Admin Block (1 No.), Lab Building (1 Nos), Auditorium (1 No)
20
-
-
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 liters capacity at all heights with coconut brushes, dusters etc., removal of silt,rubbish from the tank and cleaning the tank with fresh water disinfecting wqith bleaching powder@ 0.5 gm per liter capacity of tank including marking the date of cleaning on the side of the tank body with the help of stencil and paint and disposing of malba all complete as perdirection of Engineer-in-charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
80000
-
-
Cleaning of under ground sump, Over Head R.C.C. Tank (independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:-(i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits.(ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.(iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.(v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
267.84
-
-
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Medium shade pigment using 50% white cement 50% Grey cement
4.32
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:4 (1 cement: 4 fine sand)
12
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
0.47
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements