North Eastern Electric Power Corporation Limited Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

North Eastern Electric Power Corporation Limited - NEEPCO Tender

Works
Civil And Construction
Eprocure
Opening Date30 Sep 2020
Closing Date7 Dec 2020
Tender Amount₹ 64,75,84,114 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.1.2 Dewatering of Underground Construction Sites including all labour, plant, materials, installation, operation, power supply, maintenance and removal of pumping equipments from site

5000

-

-

... More
2. Dismantling

-

-

-

... More
2.1 Dismantling of Designated Portion of existing Anchor Blocks with Core Cutting including dismantling of RCC alongwith cutting of Reinforcement & dismantling of PCC covering all labour, materials, equipments and services for successful completion of the works as shown in the construction drawings, as per the technical specification or as directed by the Engineer-in-Charge

4650

-

-

... More
2.2 Dismantling of Structures (excluding Dismantling of designated portions of Anchor Blocks with Core Cutting): Dismantling & Demolishing of existing structures including stacking of steel re-bars and disposal of unserviceable materials within 50m lead as per the direction of the Engineer-in-Charge By Manual Means/ Mechanical Means

-

-

-

... More
2.2.1 Demolishing Brick Work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materials within 50m lead as per directioin of Engineer-in-Charge In Cement Mortar

50

-

-

... More
2.2.2 Reinforced Cement Concrete

1700

-

-

... More
2.2.3 Dismantling Tile Works on Floors & walls laid in cement Mortar including stacking material within 50m lead as per the director of the Engineer-in-Charge

-

-

-

... More
2.2.3.1 For Thickness of Tiles 10mm to 25mm

600

-

-

... More
2.2.3.2 For Thickness of Tiles above 25mm and upto 40mm

1500

-

-

... More
2.3 Cost of haulage excluding loading & unloading for removal of dismantled concrete pieces: Katcha Track beyond the initial lead of 50m (Lead = 2.0 km)

3250

-

-

... More
2.4 Chipping of concrete: Chipping of concrete and removal of all loose and friable materials followed by proper cleaning and removal of foreign materials, complete in all respect with all materials, labours, tools & plants, etc. as per the technical specification or as directed by the Engineer-in-Charge

6000

-

-

... More
3. Clearing of Debris

-

-

-

... More
3.1 Clearing of Debris along the Penstock Alignment: Clearing of Debris including Loading and unloading by mechanical means, transportation & disposal upto the initial lead of 1.0km

7500

-

-

... More
3.2 Cost of haulage excluding loading & unloading for removal of debris along penstock alignment: Katcha Track beyond the initial lead of 1.0km (Lead = 2.0 km)

7500

-

-

... More
3.3 Clearing of Debris in HRT: Clearing of Debris including Loading and unloading by mechanical means, transportation & disposal upto the initial lead of 1.0km

500

-

-

... More
3.4 Cost of haulage excluding loading & unloading for removal of debris in HRT: Katcha Track beyond the initial lead of 1.0km (Lead = 2.0 km)

500

-

-

... More
3.5 Clearing of Debris in Power House: Clearing of Debris including loading & unloading by mechanical means, transportation & disposal upto initial lead of 1.0km

200

-

-

... More
3.6 Cost of haulage excluding loading & unloading for removal of debris along penstock alignment:Katcha Track beyond the initial lead of 1.0km (Lead = 2.0 km

200

-

-

... More
4. Surface Excavation

-

-

-

... More
4.1 Excavation using manual means: Excavation using manual means including loading and carrying of excavated material to disposal areas with all lifts & leads upto 1000m

2500

-

-

... More
4.2 Excavation using mechanical means: Excavation using mechanical means including cutting, loading and carrying of excavated material to disposal areas with all lifts & leads upto 1000m

5500

-

-

... More
4.3 Cost of haulage excluding loading & unloading for removal of excavated muck: Katcha Track beyond the initial lead of 1.0km

16000

-

-

... More
4.4 Earth/ Sand Filling Earth/ sand Filling in Plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, orest royalty, sales tax and other duties and taxes as may be necessary. With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m

150

-

-

... More
4.5 Random Backfilling: Backfilling behind complete as per drawings & technical Specification. Complete in all respect with all materials, labours, tools & plants, etc. as per the technical specification or as directed by the Engineer-in-Charge

1500

-

-

... More
5. Concreting Works

-

-

-

... More
5.1 Plain Cement Concrete

-

-

-

... More
5.1.1 Plain Cement Concrete in Anchor Blocks: Plain Cement Concrete in open foundation complete as per drawings & Technical Specification including steel shuttering formwors Without Plasticiser PCC Grade M15

25

-

-

... More
5.1.2 Plain Cement Concrete along Penstock Alignment: Plain Cement Concrete in open foundation complete as per drawings & Technical Specification including steel shuttering formwors Without Plasticiser PCC Grade M15

28500

-

-

... More
5.1.3 Plain Cement Concrete in HRT: Plain Cement Concrete complete as per drawings & Technical Specification including steel shuttering formwors Without Plasticiser PCC Grade M20

1000

-

-

... More
5.1.4 Plain Cement Concrete in Power House

-

-

-

... More
5.1.4.1 Plain Cement Concrete: Plain Cement Concrete in open foundation complete as per drawings & Technical Specification including steel shuttering formwors Without Plasticiser PCC Grade M15

50

-

-

... More
5.1.4.2 Plain Cement Concrete: Plain Cement Concrete complete as per drawings & Technical Specification including steel shuttering formwors Without Plasticiser PCC Grade M20

125

-

-

... More
5.2 Reinforced Cement Concrete

-

-

-

... More
5.2.1 Reinfored Cement Concrete in Anchor Blocks: Reinforced Cement Concrete as per drawing and Technical Specification including Steel Shuttering Formwork Without Plasticiser RCC Grade M20 Using Concrete Mixer

4000

-

-

... More
5.2.2 Reinforced Cement Concrete in Saddle Supports: Reinforced Cement Concrete as per drawing and Technical Specification including Steel Shuttering Formwork Without Plasticiser RCC Grade M20 Using Concrete Mixer

2100

-

-

... More
5.2.3 2nd Stage Reinforced Cement Concrete in Saddle Supports: Reinforced Cement Concrete as per drawing and Technical Specification including Steel Shuttering Formwork Without Plasticiser RCC Grade M25 Using Concrete Mixer

105

-

-

... More
5.2.4 Reinforced Cement Concrete in Power House

-

-

-

... More
5.2.4.1 Reinfored Cement Concrete in Substructure: Reinforced Cement Concrete as per drawing and Technical Specification including Steel Shuttering Formwork Without Plasticiser RCC Grade M20 Using Concrete Mixer

70

-

-

... More
5.2.4.2 Reinfored Cement Concrete in Superstructure: Reinforced Cement Concrete as per drawing and Technical Specification including Steel Shuttering Formwork Without Plasticiser RCC Grade M20 Using Concrete Mixer

200

-

-

... More
5.2.4.3 2nd Stage Reinforced Cement Concrete in Grooves/Block Outs: Reinforced Cement Concrete as per drawing and Technical Specification including Steel Shuttering Formwork Without Plasticiser RCC Grade M25 Using Concrete Mixer

100

-

-

... More
6. Steel for Reinforcement

-

-

-

... More
6.1 Reinforcement in Anchor Blocks: Supplying, fitting and placing TMT conforming to IS: 1786 Fe 500D reinforcement including splicing complete as per drawing and technical specifications TMT- IS 1786 (Fe 500D)

180

-

-

... More
6.2 Steel Re-bar as Dowels in Anchor Blocks: Supplying, fitting and placing TMT conforming to IS: 1786 Fe 500D reinforcement including splicing complete as per drawing and technical specifications TMT- IS 1786 (Fe 500D)

95

-

-

... More
6.3 Reinforcement in Saddle Supports: Supplying, fitting and placing TMT conforming to IS: 1786 Fe 500D reinforcement including splicing complete as per drawing and technical specifications TMT- IS 1786 (Fe 500D)

40

-

-

... More
6.4 Reinforcement in Power House: Supplying, fitting and placing TMT conforming to IS: 1786 Fe 500D reinforcement including splicing complete as per drawing and technical specifications TMT- IS 1786 (Fe 500D)

40

-

-

... More
7. Drilling & Grouting

-

-

-

... More
7.1 Drilling: Percussion drilling at designated areas as shown in the construction drawings or as directed by the Engineer-in-Charge including casing, driving and permeability tests progressively complete in all respect with all labours, materials, plant, equipments, etc. as per technical specification given, drawing and as directed by the Engineer-in-Charge. Dilling of holes upto 48mm dia

6000

-

-

... More
7.2 Cement Grouting: Cement Grouting including supply of all materials like cement, sand, admixture, etc.) which are not specifically mentioned but required to complete the job), water testing of holes including supply of all required apparatus complete, labours, plants and equipments, etc. in all respect as per technical specification and as directed by the Engineer-in-Charge

12000

-

-

... More
7.3 Sand required for Grouting

30

-

-

... More
8. Drilling & Fixing of Steel Rebars as Dowels

-

-

-

... More
8.1 Providing, Placing and fixing in position Chemical rebar fastners including drilling of holes of specified size and depths upto 250mm into the old concrete, cleaning holes, placing chemicals inside the holes and fixing reinforcement bars all complete as per specification or as directed by the Engineer-in-Charge in locations indicated in the Construction Drawings

-

-

-

... More
8.1.1 20mm dia re-bar fastners

30000

-

-

... More
9. Non- Shrink Grouting

-

-

-

... More
9.1 Non- Shrink Grouting: Providing & injecting approved grout in proportion recommended by the manufacturer at location as directed by the Engineer-in-Charge by suitable gun/pump at required pressure including cutting of nipples after curing, etc. complete as per the technical specification or as directed by the Engineer-in-Charge

-

-

-

... More
9.1.1 Stirred mixed non shrink cementitious grout of approved make

1700000

-

-

... More
10. Concrete Waterproofing

-

-

-

... More
10.1 Providing, applying "XYPEX" Concrete Water Proofing & Durability Enhancement by Crystallization to be supported by at least two International Test Reports showing clear Scanning Electron Microscopic (SEM) Photographs of desified and mature crystals forming to plug all the capilary tracks and pores of the concrete permanently and permeability test as per IS: 720 conducted by CBRI. The concrete should not absord water more than 0.5 grams and not more than 1mm from the concrete surface. The product to be listed in ICC-ES-EVALUATION REPORT INDEX January 2009. The treatment to be carried out on the concrete surfaces as per manufacturer's specification and as directed by the Engineer-in-Charge. The treatment to be carried out on the concrete surfaces including cleaning of all RCC surfaces as per manufacturer's specification/ datasheet. The application to be carried out in two coats with coverage rate of 0.8kg per coat

2000

-

-

... More
11. Epoxy based Bonding Agent

-

-

-

... More
11.1 Supplying, mixing and applying a Epoxy resin based bonding agent of reputed make for proper bond of old to new concrete

3000

-

-

... More
12. Masonry and Allied Works

-

-

-

... More
12.1 Stone Work Stone Masonry Works in Cement Mortar 1:3 complete in all respect as per construction drawings and technical specification

-

-

-

... More
12.1.1. Random Rubble Masonry

500

-

-

... More
12.2 Brick Work

-

-

-

... More
12.2.1 230mm thick Brick Wall in cement mortar with 1st class brick including racking out joints and curing complete as directed in structure

-

-

-

... More
12.2.1.1 In Substructure upto plinth level including dewatering , if necessary

-

-

-

... More
a) In Proportion 1:4

200

-

-

... More
12.2.2 1st Class Brick Nogged Wall in cement mortar including racking out joints and curing complete as per technical specification and as directed by the Engineer-in-Charge

-

-

-

... More
12.2.2.1 112mm Thick Brick Wall

-

-

-

... More
a) In cement mortar in proportion 1:4 (1 cement: 4 sand)

600

-

-

... More
12.3 Providing and laying 25mm thick Damp Proof Course with cement concrete in prop 1:1.5:3 with graded stone aggregate of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing, etc. complete in all respect as per the technical specifiucation and as directed by the Engineer-in-Charge

75

-

-

... More
12.4 Plinth Protection Works

-

-

-

... More
12.4.1 Providing Plinth Protection with Bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish

150

-

-

... More
12.4.2 Providing drain with Cement Concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling sides after completion of work etc. as specified. 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm

500

-

-

... More
13. Plastering Works

-

-

-

... More
13.1 Cement Plaster in Fine Sand: Cement Plaster in Single Coat including arises or rounded angles not exceeding 80mmgirth and finished even and amooth including curing complete as per technical specification and as directed by the Engineer-in-Charge

-

-

-

... More
13.1.1 12 mm Thick Cement Plaster of Mix 1:4 (1 Cement: 4 Fine Sand)

1800

-

-

... More
13.1.2 15 mm Thick Cement plaster on the rough side of single or half brick wall of mix 1:4 (1 Cement: 4 Fine Sand)

350

-

-

... More
13.1.3 6mm Thick Plaster of Mix 1:3 (1 Cement: 3 Fine Sand)

200

-

-

... More
13.1.4 Cement Plaster with a Floating Coat of Neat Cement

-

-

-

... More
13.1.4.1 15 mm Thick Cement Plaster finished with a floating coat of neat cement of mix: 1:3 (1 Cement : 3 Fine Sand)

100

-

-

... More
14. Finishing Works

-

-

-

... More
14.1 Brick Soling: Providing Soling in Foundation and under floor with stone/ best quality picked Jhama Brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete in all respect as per the technical specification and as directed by the Engineer-in-Charge. Brick on Flat Soling

200

-

-

... More
14.2 Floor Finishing Works

-

-

-

... More
14.2.1 Vitrified Tiles

-

-

-

... More
14.2.1.1 On Floor: Providing Vitrified Floor Tiles of approved quality of specified size, shape and thickness not less than 18mm on floors over 15mm thick base of cement mortar in prop 1:3 (1 cement: 2 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile/ White Cement Slurry mixed with approved pigment to match the shade of the tiles, complete at all levels as specified in the technical specification and as directed by the Engineer-in-Charge Deluxe Range: Of Size 1200mm x 1600mm and above

200

-

-

... More
14.2.1.2 On Skirting: Providing Vitrified Floor Tiles of approved quality of specified size, shape and thickness not less than 18mm on skirting over 15mm thick base of cement mortar in prop 1:3 (1 cement: 2 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile/ White Cement Slurry mixed with approved pigment to match the shade of the tiles, complete at all levels as psecified in the technical specification and as directed by the Engineer-in-Charge Deluxe Range: Of Size 1200mm x 1600mm and above

100

-

-

... More
14.2.2 Ceramic Tiles

-

-

-

... More
14.2.2.1 On Walls: Providing polished Ceramic Wall Tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop. 1:3 (1 cement: 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-a-Tile/ White Cement Slurry mixed with approved pigment to match the shade of tiles complete as all levels as specified in the technical specification and as directed by the Engineer-in-Charge Deluxe Range: Of Size 300mm x 450mm and above

590.62

-

-

... More
14.2.3 Anti- Skid Tiles

-

-

-

... More
14.2.3.1 On Floor: Providing Anti Skid Tiles of approved quality size, shape and thickness not less than 8mm on floor over a cement mortar bed of 15mm thick in prop 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-a_Tile/ White Cement complete at all level as specified in the technical specification and as directed by the Engineer-in-Charge Vitrified: Executive Range- 2 (Size 600mm x 600mm and above)

200

-

-

... More
14.2.3.2 On Skirting: Providing Anti Skid Tiles of approved quality size, shape and thickness not less than 8mm on floor over a cement mortar bed of 15mm thick in prop 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-a_Tile/ White Cement complete at all level as specified in the technical specification and as directed by the Engineer-in-Charge Vitrified: Executive Range- 2 (Size 600mm x 600mm and above)

50

-

-

... More
14.2.4 Granite Flooring

-

-

-

... More
14.2.4.1 Providing Polished Granite Tiles of approved quality, size shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15mm thick base of cement mortar in prop 1:3 (1 cement: 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-a-Tile/ White Cement Slurry mixed with approved pigment to match the shade of tiles complete at all levels as specified in teh technical specification and as directed by the Engineer-in-Charge

-

-

-

... More
a) With Fix-a-Tile

250

-

-

... More
b) With Whire Cement

250

-

-

... More
14.2.5 Metallic Hardner/ Ironite Flooring

-

-

-

... More
14.2.5.1 Providing & laying 65mm thick CC Floor with metallic concrete hardner topping under layer of 50mm thick cement concrete 1:2:4 (1 Cement: Coarse Sand: 4 Coarse Aggregate of 20mm & down) and top layer of 15mm thick of metallic cement hardner consisting of mix 1:2 (1 cement hardner mix: 2 stone aggregate 6mm and down) by volume with which metallic hardening compound of approved quality is mixed in the ratio of 4:1 (4 parts of cement: 1 part of metallic floor hardening compound of approved quality by weight) including finishing with curing complete as directed

400

-

-

... More
14.2.6 Acid/ Alkali Resistant Tiles

-

-

-

... More
14.2.6.1 Providing and fixing 10mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resistant mortar bedding and joints filled with acid and/or alkali resistant cement as per IS: 4457, complete as per the direction of the Engineer-in-Charge

-

-

-

... More
a) In flooring on a bed of 10mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand) Acid and Alkali Resistant Tiles

300

-

-

... More
b) In dado/ Skirting on 12mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand) Acid and Alkali Resistant Tiles

300

-

-

... More
14.2.7 Epoxy Flooring

-

-

-

... More
14.2.7.1 Providing and applying normal setting, self levelling epoxy modified cementitious floor topping Sikafloor 81 EpoCem of Sika (India) Ltd. or equivalent using trowel followed by applying self smoothing epoxy floor coating Sikafloor 261(S) of Sika (India) Ltd./ Dr. Sealkit EPU Floor Self L (Asian Chemicals)/ MASTERTOP 542 ECC of BASF or equivalent using serrated trowel and rolled with a spiked nylon roller after proper surface preparation and application of a priming coat of Sikafloor 80 Primer or equivalent as specified and directed by the Engineer-in-Charge

1250

-

-

... More
14.3 Door, Windows & Ventilator

-

-

-

... More
14.3.1 Aluminium Doors

-

-

-

... More
14.3.1.1 Providing, fitting and fixing anodised aluminium framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section of approved brand with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm, lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock angles, cleat, etc. complete as specified and directed by the Engineer-in-Charge at all levels including cost of Glass & Glazing

-

-

-

... More
a) 6mm Clear Glass

50

-

-

... More
b) 5mm Frosted Glass

50

-

-

... More
14.3.1.2 Providing and fixing anodised aluminium frame double leaf doors of approved brand with styles size 45mm x 48mm x 3.2mm, top rails 50mm x 45mm x 2.5mm, lock rails 48mm x 45mm x 2.5mm, bottom rails 100mm x 45mm x 2.5mm fitted with tapper clips of size 20mm x 15mm x 1.2mm complete with automatic floor mounted door closure, butterfly type handles, special cylindrical lock, concealed type aluminium tower bolt, neoprene dryset rubber gasket, door felt gasket, etc. complete in all respect as directed by the Engineer-in-Charge at all levels including cost of Glass & Glazing

-

-

-

... More
a) Double Leaf Doors

-

-

-

... More
i. 5mm thick plain forsted glass

100

-

-

... More
ii. 6mm thick clear glass

100

-

-

... More
14.3.1.3 Providing and fixing anodised aluminium framed single leaf door of approved brand with styles 45mm x 48mm x 3.2mm, top rails 50mm x 45mm x 2.5mm, lock rails 48mm x 45mm x 2.5mm, bottom rails 100mm x 45mm x 2.5mm fitted with tapper clips of size 20mm x 15mm x 1.2mm complete with automatic hydraulic mounted door closure, butterfly type handles, special cylindrical locks, concealed type tower bolt, neoprene dryset, rubber gasket, etc. complete as directed by the Engineer-in-Charge as all levels including cots of Glass & Glazing

-

-

-

... More
a) 6mm clear glass

100

-

-

... More
b) 5mm plain frosted glass

100

-

-

... More
14.3.2 Aluminium Windows & Ventilators

-

-

-

... More
14.3.2.1 Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC Blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, fristion stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels including cost of Glass & Glazing

-

-

-

... More
a) Side Hung and Top Hung Wndows and Ventilators

-

-

-

... More
i. 6mm clear glass

800

-

-

... More
ii. 5mm frosted glass

30

-

-

... More
b) Fixed windows and ventilators

-

-

-

... More
i. 6mm clear glass

35

-

-

... More
ii. 5mm frosted Glass

25

-

-

... More
14.3.3 Steel Doors

-

-

-

... More
14.3.3.1 Providing and fixing 1mm thick MS Sheet door with frame of 40x40x6mm angle iron and 3mm MS Gusset Plates at the junctions and corners, all necessary fittings complete including applying a priming coat of approved steel primer

-

-

-

... More
a) Using MS Angles for 40x40x6mm for diagonal bracings

10

-

-

... More
14.3.4 PVC, FRP Doors & Door Frames

-

-

-

... More
14.3.4.1 Providing, fitting and fixing Syntex PVC Door frame made out of extruded PVC section in an overall size of 50mm x 60mm having multi chamber cross section with maximum wall thickness of mm, +0.3mm with special polymeric reinforcement having an overall size of 30mm x 25mm width, 150mm length at hardware location. The corner joints shall be either mitre cut and welded or joined by means on concealed cleats with necessary screws fittings

20

-

-

... More
14.3.4.2 FRP Frame: Providing & Fixing of factory made FRP Door Frame having three legged of cross section 90mm x 45mm having single rebet of 32mm x 15mm to receive shutter of 30mm thickness. The laminate door frame moulded with fire retardant grade unsaturated polyster resin and chopped mat. Door Frame Laminate and shall be filled with suitable wooden block in all the three legs the frame shall be coverde with covered glass from all sides. MS Stay shall be provided at the bottom to steady the frame

40

-

-

... More
14.3.4.3 Providing, fitting and fixing PVC Door Shutters of 37mm (Single Panel Seamless Finish) of Syntex make, at all levels made o extruded sections in the configuration of "A". The overall dimension is 37mm x 90mm, with usual provess variation having a wall thickness of 2mm with a variation of +0.03mm provided with all plastic reinforcement to avoid rusting. The shutter frame is mitred and joined at the corners by means of stainless steel screws. The corners of the frame are being reinforced by polymeric reinforcement to the size 125mm x 250mm and the lock rail is reinforced by 45 x 18 x 255 size reinforcement

20

-

-

... More
14.3.4.4 FRP Flush Door: Supplying & fixing of factory made 30mm thick FRP Panelled Door shutter of required colour made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles, with wooden frame & suitable blocks of seasoned wood inside at required places for fixing, cast monolithically with 5mm thick FRP laminates for panel and conforming to IS: 14856- 2000 including fixing to frames complete as per the direction of the Engineer-in-Charge

40

-

-

... More
14.3.5 Door & Window Fittings

-

-

-

... More
14.3.5.1 Providing aqnd fixing mild steel round holding down bolts with nuts and washer plates complete

100

-

-

... More
14.3.5.2 Providing and fixing bolts including nuts & washers complete

200

-

-

... More
14.3.5.3 Providing and Fixing MS Rivets of sizes in position

200

-

-

... More
14.3.6 Electro Coloured Iron Fittings Supplying, itting, fixing electro coloured irom fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes including necessary screws etc. complete

-

-

-

... More
14.3.6.1 Sliding Door Bolts

-

-

-

... More
a) 300mm x 16mm

30

-

-

... More
b) 250mm x 16mm

20

-

-

... More
14.3.6.2 Tower Bolts

-

-

-

... More
a) 300mm x 10mm

15

-

-

... More
b) 250mm x 10mm

10

-

-

... More
14.3.6.3 MS Door handles

-

-

-

... More
a) 100mm

10

-

-

... More
b) 150mm

10

-

-

... More
14.3.6.4 MS Butt Hinge Heavy Type

-

-

-

... More
a) 50mm x 40mm x 2.5mm

20

-

-

... More
b) 75mm x 60mm x 3.15mm

20

-

-

... More
14.3.6.5 MS Double Acting Spring Hinge

-

-

-

... More
a) 125mm

10

-

-

... More
b) 150mm

10

-

-

... More
14.3.6.6 Mortice Lock Vertical Type Aldrop within Built Lock- 6 Lever

50

-

-

... More
14.3.6.7 Door Closure & Floor Spring Providing, fitting and fixing Door Closer of various type UL listed and fire rated good quality depending on the door specification and as directed by the Engineer-in-Charge

-

-

-

... More
a) Heavy Duty Door Closer (Size 180mm x 65mm x 64mm)

20

-

-

... More
b) Concealed Door Closer (230mm x 76.5mm x 30.5mm)

20

-

-

... More
14.3.6.8 Providing, fitting and fixing Floor Spring of various weight & type UL listed and fire rated good quality depending on the floor specification and as directed by the Engineer-in-Charge

-

-

-

... More
a) Heavy Duty Floor Spring D100 (Size 274mm x 97mm x 40mm)

10

-

-

... More
b) Fire rated Floor Spring B803/ B804 (Size 307mm x 109mm x 40mm/ 307mm x 109mm x 40mm)

20

-

-

... More
14.3.7 Brass Fittings Supplying, itting, fixing brass irom fittings of approved make, reasonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes including necessary screws etc. complete

-

-

-

... More
14.3.7.1 Sliding Door Bolts

-

-

-

... More
a) 300mm x 16mm

30

-

-

... More
b) 250mm x 16mm

20

-

-

... More
14.3.7.2 Tower Bolts

-

-

-

... More
a) 300mm x 10mm

15

-

-

... More
b) 250mm x 10mm

10

-

-

... More
14.3.7.3 Door Handles

-

-

-

... More
a) 100mm

10

-

-

... More
b) 150mm

10

-

-

... More
14.3.7.4 Butt Hinge

-

-

-

... More
a) 125mm x 50mm x 4mm

20

-

-

... More
b) 100mm x 50mm x 4mm

20

-

-

... More
14.3.7.5 Spring Hinge

-

-

-

... More
a) 125mm

10

-

-

... More
b) 150mm

10

-

-

... More
14.3.7.6 Morticed Lock Vertical Type 75mm

30

-

-

... More
14.3.8 Rolling Shutter Supplying and fixing rolling shutters of approved make, made of required size MS Laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shafts with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454- Part 1 and MS Top Cover of required thickness for rolling shutters

-

-

-

... More
14.3.8.1 80 x 1.25mm MS Laths with 1.25mm thick top cover

100

-

-

... More
14.3.8.2 Providing & Fixing Ball Bearing for Rolling Shutter

20

-

-

... More
14.3.8.3 Extra for providing mechanical device chain and crank operation for operating rolling shutters Exceeding 10 Sqm in area

80

-

-

... More
14.4 Painting Works

-

-

-

... More
14.4.1 Construction of chamber for 100mm sluices valveProviding two coats of JK wall Putty (White Cement based putty for Concrete/ Mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the Engineer-in-Charge (total thickness of two coats is maximum 1.5mm)

16500

-

-

... More
14.4.2 Exterior Painting

-

-

-

... More
14.4.2.1 Finishing walls with water proofing Cement Paint of Required Shade: (two or more coats applied @ 3.84 kg/10 sqm)

3500

-

-

... More
14.4.2.2 Finishing Walls with textured exterior paint of required shade: (two or more coats applied @ 3.28 ltr/10 sqm) over & including priming coat of exterior primer applier @ 2.2kg/10 sqm

2500

-

-

... More
14.4.2.3 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: (two or more coats applied @ 1.43 ltr/ 10 sqm over & including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1500

-

-

... More
14.4.3 Interior Painting

-

-

-

... More
14.4.3.1 Finishing with deluxe Multi Surface Paint System for interiors and exteriors using Primer as per Manufacturers Specifications and as directed by the Engineer-in-Charge

-

-

-

... More
a) Two or more coats applied on walls @ 1.25 litres/ 10 swm over and inclusing one coat of special primer applied @ 0.75 litre/ 10 sqm

4000

-

-

... More
b) Finishing with Epoxy Paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation on surface, etc. complete as per specification and as directed by the Engineer-in-Charge: On Concrete Works

5000

-

-

... More
14.4.4 Painting of Steel Works

-

-

-

... More
14.4.4.1 Finishing with deluxe Multi Surface Paint System for interiors and exteriors using Primer as per Manufacturers Specifications and as directed by the Engineer-in-Charge

-

-

-

... More
a) Painting Steel Work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 litre/10 sqm over an under coat of primer applie @ 0.80 liter/ 10 sqm of approved brand and manufacturer

200

-

-

... More
b) Finishing with Epoxy Paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation on surface, etc. complete as per specification and as directed by the Engineer-in-Charge: On Steel Works

200

-

-

... More
14.4.4.2 Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacturer and required colour over a priming coat of approved steel primer on new work

-

-

-

... More
a) 100mm Diameter Pipes

100

-

-

... More
b) 150mm Diameter Pipes

200

-

-

... More
14.5 Spandrel Glass Panelling

-

-

-

... More
14.5.1 Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi-rigid, inorganic, non-combustible fibre glass wool insulation 50mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5mm and nominal mass not less than 60gm/sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay process including 1.5mm thick solid aluminium sheet backing using 6mm thick cement board including SS rivets, nuts, bolts, washers, etc. complete.

1500

-

-

... More
14.5.2 Providing and supplying Spandrel Glass panels comprising of 6mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface# 2 of approved colour and shade so as to match the colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. all complete for the required performances as specified, as per the Architectural Drawings, as per the approved shop drawings, as specified, and as directed by the Engineer-in-Charge

1500

-

-

... More
14.6 False Ceiling & Partition Works

-

-

-

... More
14.6.1 Ceiling with Exposed Metal (GI) Frame Work with E-Grid-2430: Providing & Fixing in position Suspended false Ceiling using E- Grid (Exposed Ceiling Suspension 2430 System) of grid size 600mm x 600mm/ 1200mm x 600mm with main runner 38mm x 24mm, Cross Tee 29mm x 24mm & wall angle 24mm x 24mm. Using 4mm/ 6mm thick High pressure Stem Cured Non Asbestos Fibre cement Board as per IS: 14862, to be placed in a grid of GI System duly suspended with 4mm/ 6mm dia GI/ MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors, etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm Cross Tee to be interlocked between main runners @ 610mm c/c so as to form 600mm x 600mm/ 1200mm x 600mm grid all complete as per the drawings/ specification and as directed by the Engineer-in-Charge

-

-

-

... More
14.6.1.1 Standard Ceiling as directed by the Engineer-in-Charge

-

-

-

... More
a) Using 6mm thick FC Board

500

-

-

... More
14.6.1.2 Designer Ceiling as directed by the Engineer-in-Charge

-

-

-

... More
a) Using 6mm thick FC Board

1000

-

-

... More
14.6.2 Pre- Laminated Particle Board

-

-

-

... More
14.6.2.1 Providing, fitting and fixing in position 62mm thick double skin partition with well seasoned Sal, Bonsum/ Sundi/ Hollock frame in size 75mm x 38mm and internal frame of 50mm x 38mm and fixing on both sides 8mm thick flat pressed melamine faced pre- laminated baggage board medium density fibre boards (MDF) bonded with phenol formaldehyde synthetic resin of approved shade as specified and directed at all levels. With bajaj- exterior grade (one side decorative) 8 mm thick

500

-

-

... More
14.7 Water Proof Coatings

-

-

-

... More
14.7.1 Applying one coat of epoxy coating followed by two coats of Polyurethane Waterproofing coating at an interval of 12 hours each for waterproofing as specified & directed by the Engineer-in-Charge

1500

-

-

... More
14.7.2 Applying 2 coats of 1mm thick acrylic polymer modified cementitious waterproofing coating of approved brand for waterproofing of structures structures as specified after proper surface preparation and soaking the surface with water prior to application complete in all respect as per technical specification and as directed by the Engineer-in-Charge

1500

-

-

... More
15. Repairing of Existing Damaged Concrete

-

-

-

... More
15.1 Installation of injection system for epoxy grout/ non- shrink grout: Installation of non-returnable Packers fixed at required interval including drilling of holes upto a depth of approx. 1/3rd depth of the concrete thickness using a heavy duty drill machine, cleaning of holes, fixing of packers with structural mortar or epoxy mortar, etc. complete in all respect including all materials, labours, tools & plants, etc. as per the technical specification or as directed by the Engineer-in-Charge

5500

-

-

... More
15.2 Cutting both sides of construction joints in V Groove of size as directed by the Engineer-in-Charge along the construction lift joints for application of high grade dual shrinkage compensated epoxy mortar complete in all respect including labours, tools & plants, etc. as per the technical specification or as directed by the Engineer-in-Charge

1800

-

-

... More
15.3 Placing of high grade dual shrinkage compensated epoxy repair mortar for repair of designated locations as directed by the Engineer-in-Charge with high flow, single component, dual shrinkage compensated, cementious micor concrete that acheives a comprehensive strength of minimum 50 MPa in 3 days and 70MPa in 28 days, complete in all respect with all materials, labours, tools & plants, etc. as per the technical specification or as directed by the Engineer-in-Charge

1200

-

-

... More
15.4 Application of Epoxy Grout: Application of low viscous, high swelling, thermosetting epoxy grout with hardner solution through already fixed non-returnable packers along the cracks/ construction joints using medium to high pressure special injection pumps. The mixing should be done as per the manufacturer's specification and using specialized applicator. The amount of hardner per litre depends on the required pot life at present ambient temperature, the epoxy hardner shall be mixed until the colour gets uniform and application shall be carried out within the pot life. Complete in all respect with all materials, labours, tools & plants, etc. as per the technical specification or as directed by the Engineer-in-Charge

1300

-

-

... More
15.5 Restrengthening Works

-

-

-

... More
15.5.1 Restrengthening of RCC Members by the following processes as speciied and directed by the Engineer-in-Charge complete at all levels

-

-

-

... More
15.5.1.1 Doing patch work in depression of concrete surface whereever necessary by laying epoxy putty, Concresive 2200 of BASF India Ltd. or equivalent as specified & directed by the Engineer-in-Charge complete after proper surface preparation and proper scrapping of concrete protrusion

1000

-

-

... More
15.5.2 Application of MBRACE Fibre restrengthening System of BASF India Ltd. or equivalent including laminate and sheet products for increasing the strength of concrete structures.

-

-

-

... More
15.5.2.1 In Columns: Parchange supply and application of MBRACE CF 230- Unidirectional Carbon Fibre reinforcement System of BASF India Ltd. or equivalent having 400 gm/sqm weight and having modulus of elasticity of 240 kN/mm2 at the entire length of the beam with one layer after proper application of Concresive 2200 at the entire beam area at a thickness of 2mm, which will be followed by the application of MBRACE saturant at the green condition and after proper wrapping the second layer of MBRACE staurant to be applied. Sand to be broadcasted over the MBRACE saturant layer in green condition for application of ant top screed of plastering

400

-

-

... More
15.5.2.2 In Slabs & Beams: Parchance supply and application of ready to use Carbon laminates (Fibre Reinforced Polymer) for the reinforcement of concrete elements with MBRACE FRP Laminates of 165/2500, 50mm wide & 1.4mm thick system or equivalent at the bottom portion of the beam, after application of MBRACE Laminate Adhesive or equivalent, which is having minimum 2.5 MPa adhesion strength

500

-

-

... More
15.5.3 Strengthening with Glass Fibre

1000

-

-

... More
15.6 Application of Micro- Concrete for Retrofitting / Restrengthening

-

-

-

... More
15.6.1 Chipping and breaking/ cutting of loose concret6e, mortars, etc. using Electrical Chipping Hammers to the satisfaction of the Engineer-in-Charge for successful execution of the subsequent rehabilitation works at all heights with all leads, lifts, etc. complete with all tools and machineries required for the job, operator, applicator, labour, scaffolding for staging and supervision, etc.

500

-

-

... More
15.6.2 Providing and applying two coats of Nitozinc Primer a tow component epoxy zinc rich primer/ Sika Top Armatec- 108 or equivalent product on the properly cleaned and prepared steel bars after the required chipping and cleaning of the concrete surface as per the manufacturer's specifications

500

-

-

... More
15.6.3 Before laying of the Micro Concrete, the substrate shall be coated with a bonding agent, Nitobond EP Std./ Sikadur- 32 LP or equivalent product and the micro concrete shall be poured within 6 hrs/ 4hrs or as applicable of the application of the Bonding Agent

500

-

-

... More
15.6.4 Providing and fixing shear connectors of 10mm dia at 400 c/c HYSD Steel with two components Styrene & cement free, epoxy acrylate fixing and anchoring compound supplied in self mixing Cylinder-in-Cartridge from that avoids site mixing using standard sealant applicator gun after drilling holes of 10mm diameter to a minimum depth of 80-100mm at required locations, inclusive of all materials. manpower. (Steel to be paid extra) (HILTI/ Fischer or equivalent)

2500

-

-

... More
15.6.5 Providing and placing free flow micro concrete Renderoc RG/ Sika Micro- Concrete-2 or equivalent product of after fixing slurry tight shuttering. The micro concrete should be mixed mechanically while maintaining water, power ration of 0.16 strictly in accordance with the manufacturer's instructions and as per the direction of the Engineer-in-Charge. The micro concrete should develop a compressive strength of 10 N/mm2 within 1 day, 40 N/mm2 within 7 days and 50 N/mm2 within 28 days. The cost is inclusive of materials, transportations, labour, taxes, etc. all complete

100

-

-

... More
15.6.6 Plyboard Shuttering Providing formwork of 12mm thick Plywood Board so as to give a rough finish including centering, shuttering, strutting and propping, etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in:

-

-

-

... More
15.6.6.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like TEE/ L etc. having plane vertical face

100

-

-

... More
15.6.6.2 Flat Surfaces such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas, Balconies and the like:

-

-

-

... More
a) Floors, etc. upto 200mm in thickness

300

-

-

... More
b) Floors, etc. above 200mm in thickness

200

-

-

... More
16. Water Supply, Sewage and Sanitation

-

-

-

... More
16.1 Sanitary Works

-

-

-

... More
16.1.1 Providing, fitting & fixing Vitreous China Dual Flush/ Floor Mounted Coupled/ Extended Water Closet (European type WC Pan 400mm high) with seat & lead, Flushing Cistern, CP Brass Hinges and rubber buffers, CI/ MS Brackets, 40mm dia flush band with fittings including painting of fittings and brackets, if required Hindware make White One Piece Water Closet

-

-

-

... More
16.1.1.1 Altor (Cat. No. 92052) (Inclusive of Seat Cover and fittings)

2

-

-

... More
16.1.1.2 Coral (Cat. No. 92008) (Inclusive of Seat Cover and fittings)

2

-

-

... More
16.1.1.3 Elisa (Cat. No. 92046)/ Rubbic (Cat. No. 92063) (Inclusive of seat cover and fittings)

2

-

-

... More
16.1.1.4 Inox (Cat. No. 92043)/ Inox-100 (Cat. No. 92050) (Inclusive of seat cover & fittings)

2

-

-

... More
16.1.2 Providing, fitting and fixing vitreous flat back type lipped front urinal basin of automatic flushing cistern with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors whereever required Hindware make White

-

-

-

... More
16.1.2.1 Aquafree Urinal (Cat. No. 60017)

4

-

-

... More
16.1.2.2 Urinal Omega E-Sense (Cat. No. 96006)

4

-

-

... More
16.1.3 Supplying, fitting and fixing Vitreous China Division Plate including fitting and fixing complete as directed and specified

-

-

-

... More
16.1.3.1 Hindware make White New Division Plate (Cat. No. 61005)

10

-

-

... More
16.1.4 Providing Vitreous China wash basin with CI/ MS brackets, CP Brass Chain with Plug, PVC waste Pipe including painting of fittings and brackets, cutting and making good the walls whereever required Table Top Basin Jaquar make

-

-

-

... More
16.1.4.1 Kubix (Cat. No. KUS-WHT-0552)

2

-

-

... More
16.1.4.2 JDBC (Cat. No. JDS-WHT-0550)

2

-

-

... More
16.1.4.3 JDBC (Cat. No. JDS-WHT-0547)

2

-

-

... More
16.1.5 Providing, fitting & fixing stainless steel kitchen sink of Parryware make with CI/ MS Brakets, CP Brass Chain with Rubber Plug, PVC Waste Pipe, etc. complete including painting the fittings, cutting & making good the walls wherever required

-

-

-

... More
16.1.5.1 Parryware makeSingle Bowl with veg bowl & Drain Board (400 x 200) Flat Edge- Glossy (Cat. No. C8545)

2

-

-

... More
16.1.6 Providing, fitting and fixing Decorative Mirror complete as directed and specified Parryware make Size 600mm x 450mm

10

-

-

... More
16.1.7 Providing, fitting and fixing Glass Shelf complete as directed and specified Glass shelf with CP Guard Rail Jaquar make Kubix 600mm long (Cat. No. AKB- 35771)

10

-

-

... More
16.1.8 Providing, fitting and fixing Glass Shelf complete as directed and specified Corner Glass Shelf with Brackets of Jaquar make Jaquar make Continental (Cat. No. ACN- 1173)

4

-

-

... More
16.1.9 Providing, fitting and fixing CP Soap Tray/ Soap Dish complete as directed and specified Jaquar make

-

-

-

... More
16.1.9.1 Queen's (Cat. No. AQN- 7731)

3

-

-

... More
16.1.9.2 Kubix (Cat. No. AKB- 35731)

3

-

-

... More
16.1.10 Providing, fitting and fixing Liquid Soap Dispenser and liquid soap container complete as directed and specified Jaquar make

-

-

-

... More
16.1.10.1 Kubix make Glass Bottle (Cat. No. AKB- 35735)

8

-

-

... More
16.1.11 Providing, fitting and fixing CP towel rail complete as directed and specified Jaquar make

-

-

-

... More
16.1.11.1 Queen's (600mm long) (Cat. No. AQN- 7711)

8

-

-

... More
16.1.11.2 Queen's (450mm long) (Cat. No. AQN- 7711A)

8

-

-

... More
16.1.12 Providing, fitting and fixing Chrome Plated Towel Ring complete as directed and specified Jaquar make Queen's (Cat. No. AQN- 7721)

6

-

-

... More
16.1.13 Providing, fitting and fixing Chrome Plated Toilet paper Holder complete as directed and specified Jaquar make

-

-

-

... More
16.1.13.1 Continental Toilet Paper Holder with Flap (Cat. No. CAN- 1151N)

4

-

-

... More
16.1.13.2 Queen's Toilet Paper Holder with Flap (Cat. No. AQN- 7753)

4

-

-

... More
16.1.14 Providing, fitting and fixing Chrome Plated Waste Coupling complete as directed and specified

-

-

-

... More
16.1.14.1 Jaquar make 32mm (HT/FT) (Cat. No. ALD-705/ 709)

15

-

-

... More
16.1.14.2 Cera make Waste Coupling (Full Thread) 40mm (Cat. No. CA 103)

15

-

-

... More
16.1.15 Providing, fitting and fixing Chrome Plated Bottle Trap complete as directed and specified Jaquar make

-

-

-

... More
16.1.15.1 Bottle Trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat. No. ALD- 769)

15

-

-

... More
16.1.15.2 Bottle Trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat. No. ALD- 769B)

15

-

-

... More
16.1.16 Providing, fitting and fixing Chrome Plated Grating complete as directed and specified

-

-

-

... More
16.1.16.1 160mm Dia

15

-

-

... More
16.1.16.2 110mm Dia

10

-

-

... More
16.1.17 Supplying, fitting and fixing approved uPVC Pipes of different sizes, with all necessary "R" Brand or similar approved uPVC Fittings such as bend, Tee, Elbow, reducer, nipple, plug, tee, long screw fitting, clamps, etc. complete at all levels including below GL as directed and specified

-

-

-

... More
16.1.17.1 Exposed or in Trenches Supreme/ Prince/ SFMC Brand or other equivalent approved brand (High Pressure Pipe Sch-40)

-

-

-

... More
a) 50mm dia

300

-

-

... More
b) 40mm dia

300

-

-

... More
c) 32mm dia

300

-

-

... More
d) 25mm dia

200

-

-

... More
e) 20mm dia

50

-

-

... More
f) 15mm dia

50

-

-

... More
16.1.17.2 Concealed by Chiselling or breaking brick wall/ CC wall/ RC Wall and making good to the damaged structure Supreme/ Prince/ SFMC Brand or other equivalent approved brand (High Pressure Pipe Sch-40)

-

-

-

... More
a) 25mm dia

100

-

-

... More
b) 20mm dia

150

-

-

... More
c) 15mm dia

150

-

-

... More
16.1.18 Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC Plain and Brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes joining of pipe. Exposed or in trenches

-

-

-

... More
16.1.18.1 50mm dia

100

-

-

... More
16.1.18.2 40mm dia

100

-

-

... More
16.1.18.3 32mm dia

100

-

-

... More
16.1.18.4 25mm dia

100

-

-

... More
16.1.19 Spupplying, fitting and fixing CP Bib Cock 15mm dia of approved brand as directed and specified Jaquar make

-

-

-

... More
16.1.19.1 Bib Cock Long Thread

8

-

-

... More
16.1.19.2 2- Way Bib Cock

6

-

-

... More
16.1.20 Supplying, fitting and fixing Chrome Plated (CP) Stop Cock of approved brand and size as mentioned below as directed and specified Jaquar make

-

-

-

... More
16.1.20.1 15mm dia Angular Stop Cock

10

-

-

... More
16.1.20.2 15mm dia Angular Stop Cock with long thread

10

-

-

... More
16.1.20.3 15mm dia Concealed Stop Cock reduced body

10

-

-

... More
16.1.21 Supplying, fitting and fixing CP Piller Cock of 15mm dia of approved brand as specified and directed Jaquar make

-

-

-

... More
16.1.21.1 Contenental

6

-

-

... More
16.1.21.2 Long Neck with aerator

6

-

-

... More
16.1.22 Supplying, fitting and fixing Chrome Plated Sink Cock of approved brand as directed and specified Jaquar make

-

-

-

... More
16.1.22.1 Continental/ Clarion Sink Cock with raised J shaped swinging spout

2

-

-

... More
16.1.23 Supplying, fitting & fixing Chrome Plated Flush Cock of approved brand as directed and specified Jaquar make Continental/ Clarion

-

-

-

... More
16.1.23.1 Flush Cock with wall flange 25mm with level knob

10

-

-

... More
16.1.23.2 Flush Cock with wall flange 25mm with plain knob

10

-

-

... More
16.1.24 Supplying, fitting & fixing Chrome Plated Shower 15mm dia of approved brand as directed and specified Jaquar make

-

-

-

... More
16.1.24.1 Continental Overhead Shower (ABS Chrome Plated) with rubit cleaning system

1

-

-

... More
16.1.24.2 Queen's Collection Overhead Rose Shower with revolving joint & 150mm long swivel shower arm

2

-

-

... More
16.1.25 Supplying, fitting and fixing Chrome Plated Wall Mixer complete as directed Jaquar make

-

-

-

... More
16.1.25.1 Continental/ Clarion Wall Mixer 3 in 1 system with provision for both telephonic shower and overhead shower complete with 115mm long bend pipe Cat. No. 1119

2

-

-

... More
16.1.26 Supplying, itting & fixing Push Bib Cock 15mm dia complete as specified & directed by the Engineer-in-Charge

-

-

-

... More
16.1.26.1 CPCH Heavy Type

10

-

-

... More
16.1.27 Supplying, fitting & fixing ball valve as specified and directed

-

-

-

... More
16.1.27.1 25mm dia

5

-

-

... More
16.1.27.2 20mm dia

5

-

-

... More
16.1.28 Supplying, fitting and fixing Check Valve including necessary threads to pipes

-

-

-

... More
16.1.28.1 50mm dia (Heavy Type)

10

-

-

... More
16.1.28.2 40mm dia (Heavy Type)

10

-

-

... More
16.1.29 Supplying, fitting and fixing GI Foot Valve with strainer including cutting necessary threads to pipes

-

-

-

... More
16.1.29.1 50mm dia (Heavy Type)

5

-

-

... More
16.1.29.2 40mm dia (Heavy Type)

5

-

-

... More
16.1.30 Supplying & placing Plastic Cylindrical Vertical Claused Top (PCVC) Tank make over stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet & outlet pipes Sintex make

-

-

-

... More
16.1.30.1 2000 ltr Capacity

1

-

-

... More
16.1.30.2 1500 ltr Capacity

1

-

-

... More
16.1.30.3 1000 ltr Capacity

1

-

-

... More
16.1.31 Labour of erecting and placing PCVC Tank over the staging up to a height of 5.00m complete as directed

-

-

-

... More
16.1.31.1 2000 ltr Capacity

1

-

-

... More
16.1.31.2 1500 ltr Capacity

1

-

-

... More
16.1.31.3 1000 ltr Capacity

1

-

-

... More
16.1.32 Rain Water Downcomer Supplying, fitting andfixing Pipes with all necessary fittings complete as directed by the Engineer-in-Charge GI Pipe with GI Fittings TATA/ SAIL (Medium)

-

-

-

... More
16.1.32.1 100mm Diameter

100

-

-

... More
16.1.32.2 150mm Diameter

200

-

-

... More
16.1.33 Supplying, fitting & fixing PVC Pipes of 6kg/cm2 including joining, fitting & fixing with clamps, etc. as necessary complete at all levels including below GL as directed and specified In exposed surfaces or in trenches

-

-

-

... More
16.1.33.1 160mm dia

50

-

-

... More
16.1.33.2 110mm dia

75

-

-

... More
16.1.34 Supplying, fitting & fixing 87.5 degree PVC bend withj door including joining, fitting & fixing, etc. as necessary complete at all levels including below GL as directed and specified In exposed surfaces or in trenches

-

-

-

... More
16.1.34.1 160mm dia

10

-

-

... More
16.1.34.2 110mm dia

10

-

-

... More
16.1.35 Supplying, fitting & fixing 45 degree PVC bend including joining, fitting and fixing, etc. as necessary complete at all levels including below GL as directed & specified In exposed surfaces or in trenches

-

-

-

... More
16.1.35.1 160mm dia

10

-

-

... More
16.1.35.2 110mm dia

10

-

-

... More
16.1.36 Supplying, fitting and fixing PVC single TEE including joining, fitting and fixing, etc. as necessary complete at all levels including below GL as directed and specified In exposed surfaces or in trenches

-

-

-

... More
16.1.36.1 160mm dia

10

-

-

... More
16.1.36.2 110mm dia

10

-

-

... More
16.1.37 Supplying, fitting and fixing PVC single Y with door including joining, fitting and fixing, etc. as necessary complete at all levels including below GL as directed and specified In exposed surfaces or in trenches 110mm dia

5

-

-

... More
16.1.38 Supplying, fitting and fixing PVC Double Y with door including joining, fitting and fixing, etc. as necessary complete at all levels including below GL as directed and specified In exposed surfaces or in trenches 110mm dia

5

-

-

... More
16.1.39 Supplying, fitting & fixing PVC Cross T with door including joining, fitting & fixing, etc. as necessary complete at all levels including below GL as directed and specified In exposed surfaces or in trenches 110mm x 110mm

10

-

-

... More
16.1.40 Supplying, fitting & fixing PVC Coupler including joining, fitting and fixing, etc. as necessary complete at all levels including below GL as directed and specified In exposed surfaces or in trenches 110mm dia

10

-

-

... More
16.1.41 Supplying, fitting and fixing PVC reducer including joining, fitting & fixing, etc. as necessary complete at all levels includign below GL as directed and specified In exposed surfaces or in trenches 160mm x 110mm

10

-

-

... More
16.1.42 Supplying, fitting & fixing PVC reducing Tee with door including joining, fitting and fixing, etc. in exposed surfaces or trenches as necessary complete at all levels including below GL as directed and specified 160mm x 110mm

10

-

-

... More
16.1.42.1 Supplying, fitting and fixing PVC Socket Plug including joining, fitting & fixing, etc. in exposed surfaces or in trenches as necessary complete at all levels including below GL as directed and specified 110mm

10

-

-

... More
16.1.43 Supplying, fitting and fixing PVC cleaning pipe including joining, fitting and fixing, etc. in exposed surface or trenches as necessary complete at all levels including below GL as directed and specified

-

-

-

... More
16.1.43.1 160mm dia

10

-

-

... More
16.1.43.2 110mm dia

10

-

-

... More
16.1.44 Providing, fitting & fixing PVC Cowel of ISI make complete as directed and specified

-

-

-

... More
16.1.44.1 160mm dia PVC Cowel of ISI make

10

-

-

... More
16.1.44.2 110mm dia PVC Cowel of ISI make

10

-

-

... More
16.1.45 Providing, fitting & fixing 450mm dia 90mm thick CI man hole cover & frame of 58kg weight complete as directed and specified

5

-

-

... More
16.1.45.1 Clearance of service septic tank and removing the night soil and debris, etc. manually from the tank/ chamber to a distant place by bailing out the deposited night soil, burning the same in near by trenches/ pits which has been dug earlier and covering the same. The service septic tank is cleaned with clear water and completed as directed by the department For 100 users

2

-

-

... More
17. Removal of Damaged Steel Liner from HRT

-

-

-

... More
17.1 Removal of Steel Liners in HRT including cutting, dismantling, loading, transportation, unloading & stacking in the Umrongso Store, complete in all respect including all tools & plants, labour, equipments, etc. as per the technical specification and as directed by the Engineer-in-Charge

200

-

-

... More
18. Gabions

-

-

-

... More
18.1 Boulder laid in wire crates: Providing and laying of boulders laid in wire crates made with 4mm dia GI wire conforming to IS: 280 & IS: 4826 in 100mm x 100mm mesh (weaved diagonally) including 10% extra for laps and joints laid with stone boulders

1000

-

-

... More
19. Road Works

-

-

-

... More
19.1 Preparation and consolidation of subgrade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations, etc. and re-rolling the sub-grade and disposal of surplus earth with lead upto 50m

3000

-

-

... More
19.2 Supplying and stacking at site

-

-

-

... More
19.2.1 90mm to 45mm size stone aggregate

300

-

-

... More
19.2.2 63mm to 45mm size stone aggregate

300

-

-

... More
19.2.3 53mm to 22.4mm size stone aggregate

300

-

-

... More
19.2.4 Stone Screening 13.2mm nominal size (Type A)

200

-

-

... More
19.2.5 Stone Screening 11.2mm nominal size (Type B)

200

-

-

... More
19.3 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/ vibratory roller 8 to 10 tonne cpapcity in stages to proper grade and camber, applying and brooming requisite type of screening/ binding material to fill up interstices of coarse aggregate, watering and compacing to the required density

900

-

-

... More
19.4 Supplying, stacking and spreading 6mm thick red bajri, watering and rolling complete including preparation of the surface and rolling With Road Roller/ Hand Roller

3000

-

-

... More
19.5 Surface dressing one coat on new surface with bitumen of specified grade at a rate of 1.95 kg/sqm of surface area with 1.5 cum of stone chippings 13.2mm nominal size per 100 sqm of road surface. Including consolidation with road roller of 6 to 8 tonne capacity, etc. complete: Using bitumen emulsion (minimum 50% bitumen content RS grade conforming to IS: 8887)

3000

-

-

... More
19.6 Surface dressing one coat on old surface with bitumen of specified grade at the rate of 1.22 kg/sqm of surface area with 1:10 cum of stone chippings 11.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 tonne capacity etc. complete: Using bitumen emulsion (minimum 50% bitumen content- RS grade conforming to IS: 8887)

3000

-

-

... More
19.7 Providing and laying bitumen mastic wearing course (as per specification) with industrial bitumen of grade 85/25 conforming to IS: 702, prepared by using cooker and laid to required level and slope, including providing antiskid surface with bitumen precoated fine grained hard stone chipping of approved size at the rate of 0.005 cum per 10 sqm and at approximate spacing of 10cm centre to centre in both directions, pressed into surface protruding 1mm to 4mm over mastic surface, including cleaning the surface, removal of debris, etc. all complete. (Considering bitumen using 10.2% as per MORTH Specification): 40mm thick

3000

-

-

... More
19.8 Providing and applying tack coat using hot straight run bitumen of grade VG-10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications: On bituminious surface @ 0.50 kg/sqm

3000

-

-

... More
19.9 2.5cm premix carpet surfacing with 3 cum of stone chippings 11.2mm nominal size per 100 sqm and bitumen emulsion (medium setting min. 65% bitumen contents) complying with IS: 8887, using 96 kg per cum of chippings of road surface, including consolidation with road roller, etc. Complete

3000

-

-

... More
19.10 Providing and laying seal coat of premixed fine aggregate (passing 2.36mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG-10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete

3000

-

-

... More
19.11 Concrete Pavements

-

-

-

... More
19.11.1 Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 40mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tampering complete

500

-

-

... More
19.11.2 Proving & fixing in position pre-moulded joint filler in expansion joints

40000

-

-

... More
19.11.3 Providing and laying in position bitumen hot sealing compound for expansion joint etc.: Using grade "A" sealing compound

40000

-

-

... More
20. Miscelleneous Works

-

-

-

... More
20.1 Fencing Work

-

-

-

... More
20.1.1 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th Post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires of barbed wire weighing 9.38 kg per 100m (min.), between the too posts fitted and fixed with GI staples, turn buckles, etc. complete. (Cost of Posts, struts, earth work and concrete work to be paid separately).Payment to be made per meter cost of total length of barbed wire used. Wire GI barbed wire

2000

-

-

... More
20.1.2 Supplying at site angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10cm length and drilling holes upto 10mm dia. etc. complete

5000

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.