The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Addn Altn To Smq(dsc Ors /jco Qtr) And Boundry Wall Near Dsc Mess And Allied Works At Afs Kumbhirgam in Cachar, Assam, with an estimated contract value of Rs. 84,33,000. The bid opening date for this tender is 23-10-2026 and the last date for bid submission is 20-11-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender - Assam Tender

Opening Date23 Oct 2026
Closing Soon20 Nov 2026
Tender Amount₹ 84,33,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Addn Altn To Smq(dsc Ors /jco Qtr) And Boundry Wall Near Dsc Mess And Allied Works At Afs Kumbhirgam

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove febric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as directed.

56

-7

-

... More
S & F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors ladders; framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165

1092.1

-6

-

... More
S&F for Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcement

172.4

-5

-

... More
M&L for Demolition of (unreinforced) cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level).

17.02

-4

-

... More
M&L for cement concrete 25mm thick type B1 1:2:4 for filling top surface using 20mm graded aggregates, complete all as specified and directed

340.47

-3

-

... More
M&L for Non - skid coloured Ceramic floor tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 10mm thick for laying floor finishes in cement mortar 1:6, complete all as specified and as directed. Make: Somany/ Orient/ Johnson

340.47

-2

-

... More
M&L for Glazed colour ceramic tiles as in vertical surface (350x 250x 7 mm/ 450X 350X 7mm thick) set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering cement mortar 10mm thick for fixing tile in dado/skirting in CM 1:3, complete all as specified and as directed. Make: Somany/ Orient/ Johnson

87.03

-1

-

... More
Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key scrubbing down water etc and removing materials from site of work complete all as directed.

851.2

-

-

... More
M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 5mm thick) mixed with water proofing compound in top layer @2% by the weight of cement or as per manufacturer's instructions finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note : Integral water proofing compound shall be measured and paid separetly.

1477.2

-

-

... More
Supply only integral water proofing compound complete all as specified and as directed.

56.65

1

-

... More
M & L for 10 mm thick rendering in CM (1:6) finished even and smooth without using extra cement to wall complete all as directed.

96

2

-

... More
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. ( Note :- Shade shall be approved by Engr-in-Charge)

305.2

3

-

... More
M&L for preparing of new surfaces of walls and applying two coats of oil emulsion distemper on the same after Chalk whiting, on plastered surfaces, preparatory to distempering on internal wall surfaces, all complete as specified and directed.

96

4

-

... More
M&L for Formwork in repairs to flat fair finished surface of fascia complete all as specified and directed.

48.75

5

-

... More
M&L for Reinforced cement concrete (nominal mix) with Type B1 1:2:4 (20 mm graded aggregate) as in Fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like, complete all as specified and directed.

2.3

6

-

... More
Taking down chowkats or frame with shutters (without taking off shutters from the frames ) n exc. 1.5 sqm each all as specified and directed.

88

7

-

... More
S & F for anodised aluminium frame for partition, doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed. Make of aluminium section – JINDAL/ INDAL/ HINDALCO

330.26

8

-

... More
S & F for anodised aluminium window and ventilator shutters, fixed /Sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed. Make of aluminium section – JINDAL/ INDAL/ HINDALCO

140.12

9

-

... More
S&F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed

98.2

10

-

... More
S&F for 3mm thick Sheet glass, ordinally quality and glazing with oil putty or secured with wdn beads as required in square n exc 0.5 sqm in each pane

85.2

11

-

... More
S&F for 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.

10.8

12

-

... More
S&F for galvanized mild steel wire cloth 0.56mm fixed nominal dai of wire and avrg width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed.

46.2

13

-

... More
Taking down chowkats or frame with shutters (without taking off shutters from the frames ) exc. 1.5 sqm each all as specified and directed.

38

14

-

... More
M&L For Pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete all as specified and as directed.

197.6

15

-

... More
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint, complete all as specified and as directed.

24.7

16

-

... More
S&F for 30 mm thk flush shutters, solid core construction, with particle board core and plywood face panels, one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed.

68.4

17

-

... More
M&L for 30 mm thick 2nd class H/W Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. including finished surface with plaster and paintings; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.

68.4

18

-

... More
M&L for two coats of synthetic enamel paint over a coat of pink primer of new wooden surface of any description, not other wise described over 10 cm width or girth incl. preparation of surfaces.

232.56

19

-

... More
S&F for Mild steel butt hinges medium weight , clod rolled,100mm, ISI marked, complete all as specified and directed.

114

20

-

... More
S&F 300mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed

76

21

-

... More
S&F for 200 mm long Aluminium anodised barrel tower bolt 12mm dia of extruded section (Conforming to IS)

152

22

-

... More
S & F 150 mm in size aluminium handles, cast type, anodised complete all as specified and directed.

152

23

-

... More
S&F for 150mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor including vulcanised rubber piece, complete all as specified and directed.

76

24

-

... More
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.

586

25

-

... More
S&F pre- painted galvalume aluminium zinc coating GI Based corrugated steel sheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas, fixed with self tapping screws complete all as specified & directed

540.4

26

-

... More
S&F pre- painted galvalume aluminium zinc coating GI Based plain corrugated steel sheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas, fixed with self tapping screws complete all as specified & directed

45.6

27

-

... More
S&F of PVC Eaves board size 250 mm x 18 mm thick, over lapping with solvent cement and fixing by stainless steel screw, complete all as specified & directed

34.64

28

-

... More
Dismantling of ceiling boards (fibre,pulp,insulation, etc.) any thickness including cover fillets complete all as specified and as directed.

300.2

29

-

... More
S&F for anodised aluminium snap grid frame work for false ceiling of grid size 605mmx605mm consist of anodised aluminium main/cross Tee of size 40mmx25mmx2mm, weighing 0.36kg/RM,confirming to IS 733, IS 737& IS 1285. The main and cross Tee shall be jointed at junction/crossing with anodised aluminium angle bracket of 15mmx15mmx1.5mm, weighing0.12KG/RM, fixed with suitable mild steel nut bolt & washers, snap grid frame work shall be fixed to ceiling with supporting hanger 6mm dia GI(upto 1200mm length) adjusting level fixed to roof slabs/truss by means of cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia. 40 mm long complete all as manufacturer instruction fixed as specified.

300.2

30

-

... More
M&L for Non Asbestos fibre cement building boards 4mm thick fixed or laid in aluminium frame work with screws as in ceiling complete all as directed and as directed

300.2

31

-

... More
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manhole, pier holes, etc and getting out in soft/loose soil

85.57

32

-

... More
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manhole, pier holes, etc and getting out in hard/dense soil

16.71

33

-

... More
Excavation in trenches, exc 1.5m wide and n exc 3.0m in depth for foundation, etc or for shafts, wells, cesspits, manhole, pier holes, etc and getting out in hard/dense soil

5.39

34

-

... More
M&L Cement concrete 1:4:8Type D2 (using 40mm graded aggregate) as in foundation, filling and mass concrete.

4.92

35

-

... More
Demolition of cement concrete (unreinforced concrete) in any position and any description complete all as specified and directed.

8.19

36

-

... More
M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as foundations, including rafts, footings foundation beams, plinth beams, bases for columns, etc basement slabs, under reamed piles and mass concrete

11.59

37

-

... More
M&L for Reinforced cement concrete (DESIGN MIX M-30, using 20mm graded aggregate) as Columns, pillars, piers, posts and struts

20.9

38

-

... More
M&L for Reinforced cement concrete (DESIGN MIX M30, using 20mm graded aggregate) as Beams, cantilevers, bressummers, lintels over 1.5m span

7.19

39

-

... More
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams, and similar work vertical of to batter, rough finished flat surfaces of concrete.

48.34

40

-

... More
Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished surfaces of concrete, square, rectangular or polygonal.

241

41

-

... More
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams etc, rough finished surfaces of concrete.

81

42

-

... More
M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips.

2741

43

-

... More
M&L mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips.

3637

44

-

... More
M&L brickwork with subclass 'B' old size bricks straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer -in- Charge.

61

45

-

... More
M & L for providing cement concrete type B-0 1:2:4 using 12.5mm graded stone aggregate in lintels up to 1.50m clear span, cills, steps, seismic and other bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water trough and the like including weathering, slightly rounded or chamfered angles and throating as directed including form work complete all as specified.

7.19

46

-

... More
M&L for preparation of newly plastered / previously untreated surfaces of wall or roof of any description over 10cm width or girth and applying two coats of exterior grade acrylic emulsion paint as through base coat over a coat of exterior anti fungal wall primer and two coats of exterior grade acrylic emulsion paint as in patches of different colours for making camouflage pattern as directed at site as per existing pattern complete all as specified and directed. ( Note :- Camouflage pattern shall be approved by Engr-in-Charge)

1172

47

-

... More
Dismantling of post struts (wood, steel & RCC) any section embedded in concrete including taking out embedded portion and making good disturbed ground

51

48

-

... More
Dismantling fencing wire mesh of any type and size fencing wire mesh any type

150

49

-

... More
M&L for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. Within 20mm of the length indicated)of Fe-410-w(Gde E-250A quality complete all aspecified and directed

633

50

-

... More
S & F for 12mm dia of neck Mild steel rag or Lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 15cm & n exc 30 cm long complete all aspecified and directed

43

51

-

... More
S & F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2.00mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured).

23

52

-

... More
S&F Punched tape concertina coil (Bitumen dipped) 610mm dia made with high tensile strength galvanized mild steel wire 2.60 mm dia as per IS 4454 strip material (galvanized MS strip as per IS-1730) with angle iron 'Y' shaped placed 3.00 metre apart and with 9 horizontal R.B.T stud tied with G.I staples and GI clips to retain horizontal including necessary bolts on GI barbed wire tied to angle iron with reinforced barbed tape (RBT)/ spring core 2.6mm dia wire minimum barb 9 mm width, loop spacing 250± 20mm, coil length 9 metre and fixed in position complete all as specified and directed. .

192

53

-

... More
M&L for preparing new or previously untreated steel and iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enemal paint over red oxide primer.

27.72

54

-

... More
Returning, filling, including spreading, leveling, watering and well remming in layers not exc 25cm in soft/loose soil

63.05

55

-

... More
Removing (soil) excavated materials n exc 50m and depositing where directed at a level n exc 1.5m above the sarting point

44.72

56

-

... More
M&L for plain Cement concrete 1:3:6 type C2, using 40mm aggregate as in foundations, filling and mass concrete, complete all as specified and directed.

5

57

-

... More
M&L for laying of reinforced concrete pipes, class NP3, 450mm dia laid and jointed complete with collars complete all as specified and directed.

6

58

-

... More
M & L for providing of fine dry river sand cushion in trenches for cable protection complete all as specified. NOTE: - Only compacted thickness will be measured and paid.

16.8

59

-

... More
Supply and lay unreinforced precast cement concrete cable cover for cable protection (Ready made covers) following sizes and class as specified all as per IS 5820-70, M20 grade and as directed of Class LV type I, flat size 250 X 150 X 40mm.

1380

60

-

... More
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor tvpe with high pressure die cast aluminum hosing and heat resistant complete with driver lamp bracket with impact and corrosion resistant including |thermal management in multiple optics complete with IP 65/66 protection complete with and incl 40mm bore light grade GI pipe mounting bracket 1.2m long with saddles FI clamps made out of 30 X 5mm FI and nut bolt complete all as specified

6

61

-

... More
S&F cable junction boxes weather proof for outdoor installation for loop connection of street light cable of size155x210x92mm with 5 pole terminal fixed on pole steel /pcc with suitable two flat iron clamp25x4mm with nut and bolts (duly painted with two coats of aluminium paint over a coat of red oxide primer) including provision for cable entry and exit and making holes on steel pole where required or directed incl Hensel Model no DK1600G/SHENIDER/RITTEL

6

62

-

... More
S&F cable PVC insulated and PVC shethed twin core 1.5 Sqmm 3 core round cable copper conductor from junction boxes to street light fitting incl all fixing arrangenments

48

63

-

... More
Supply and laying or fixing or passing through pipe, XLPE insulated, armoured, heavy duty electric cable with aluminium conductor 1100 Volts grade all as specified and as directed cross sectional area of size 10sqmm 4 core , complete all as specified and as directed.

230

64

-

... More
Supply and lay GI tubing light grade ISI marked for cable protection/GI strip or wire, protection at road crossing/floor/ wall/on poles or at any indicated situation etc duly sealed at both end after drawing cable including necessary clamps, saddles all as directed and specified for the sizes 80mm bore

12

65

-

... More
Supply and install & commission steel tubular swaged poles complete with cast iron base plate final taper plug bolts nuts & screws, Type 410 SP 31 (9M long) incl painting with two coats of aluminium paint overa coat of red oxide primer all as specified & as directed. Note : Excavation earthwork and PCC will be measured and paid separately

6

66

-

... More
M & L for PCC 1:2:4, type B-2, using (40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified

0.16

67

-

... More
M&L Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work in any type of strata , salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore as watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with CRS Bars 8mm dia at the rate of 100mm centre to centre both way with 12mm dia lifting handle and pit / chamber constructed 50 cm away from the edge in PCC 1:3:6 type C1, Angle iron 40x40x3mm frame for pit cover including testing on completion complete all as specified and directed.

1

70

-

... More
Taking down carefully copper/ Aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, boards, DB, MCB, light fittings etc), removing materials from site and making good disturbed surfaces of walls, floors etc, complete all as specified and directed

137

71

-

... More
M & L for point wiring with PVC insulated and unsheathed multistranded FRLS insulated unsheathed 1100 volt grade multi stranded Copper conductor cable of size 1.5 sqmm drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core FRLS insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly terminated into MS modular pressed steel box / PVC modular box of required size flushed in wall or on surface on faulse wall for light or Fan point or Ex Fan point controlled by one, one way switch 6/5 amp on modular white cover plate with frame of required size (modular pressed steel box, r white cover plate with frame deeemed to incl in the quoted rates) for mounting of switch complete all as specified and directed. Note: disturbed area of wall has to finish with cement mortar and match with existing colour of wall, rate of cement mortar and colour are inclusive in quoted rate

50

72

-

... More
All as per item No 82here-in-before but for one light point controled by one two way switch on the same board with other switches or independent all as specified and directed.

2

73

-

... More
All as per item No 82 here-in-before but for one bell point controled by one bell push on the same board with other switches or independent all as specified and directed.

6

74

-

... More
All as per item No 82 here-in before but for one 3 pin, 5 Amp socket point on the same board with other switch, complete all as specified and directed.

25

75

-

... More
All as per Item No 82 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed.

30

76

-

... More
All as per item No 82 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathed multistranded FRLS copper conductor, complete all as specified and directed

24

77

-

... More
M&L for sub main wiring with 2 run of single core 6.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of required size alongwith accessories on roof/walls/ ceiling etc including one run of 6.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 6.0 Sqmm single core cable, one run of 6.0 Sqmm earth wire and one run of PVC conduit/ casing capping shall be measured as one run length

50

78

-

... More
Supply and fix Switch piano flush button single pole, one way 6 Amp, complete all as specified and directed.

65

79

-

... More
Supply and fix Switch piano flush button single pole, two way 6 Amp, complete all as specified and directed.

2

80

-

... More
Fixing only piano flush button single pole, one way 6 Amp, complete all as specified and directed. (Serviceable Switch obtained shall be reused)

10

81

-

... More
Supply and fix bell push, flush type, 6 Amps, complete all as specified and directed

4

82

-

... More
Fixing only bell push, flush type, 6 Amps, complete all as specified and directed. (Serviceable bell push obtained shall be reused)

2

83

-

... More
Supply and fix socket outlet combination 3 pin, 6 A flush type universal complete all as specified and directed.

25

84

-

... More
Supply and fix Switch socket outlet combination 3 pin, 6 A flush type universal complete all as specified and directed.

20

85

-

... More
Fixing only Switch socket outlet combination 3 pin, 6 A flush type universal complete all as specified and directed. (Serviceable modular Switch obtained shall be reused)

10

86

-

... More
Supply and fix Switch socket outlet combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.

18

87

-

... More
Fixing only Switch socket outlet combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed. (Serviceable modular Switch obtained shall be reused)

6

88

-

... More
Supply and fixing sheet metal encloser box including Plug and socket with 25 Amps MCB (SP) complete all directed.

4

89

-

... More
Supply and fix 5 stepped type electronic fan regulator flush type complete all as specified and directed.

18

90

-

... More
Fixing only 5 stepped type electronic fan regulator flush type complete all as specified and directed. (Serviceable modular fan regulator obtained shall be reused)

12

91

-

... More
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed.

35

92

-

... More
Fixing only ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. (Serviceable ceiling rose obtained shall be reused)

15

93

-

... More
Supply and fixing LED lights fitting 4 feet 20 watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.

18

94

-

... More
Fixing only LED lights fitting 4 feet 20 watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. (Serviceable LED lights obtained shall be reused)

5

95

-

... More
Supply and fixing LED lights fitting 2 feet 10 watt 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.

7

96

-

... More
Fixing only LED lights fitting 2 feet 10 watt 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. (Serviceable LED lights obtained shall be reused)

2

97

-

... More
Disconnecting electrical wire of ceiling fan of any type / size and make, taking down from its position, dismantling blades, cleaning and greasing after removing the blade to make noise free smooth operation including painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler and replacement of pvc twin twisted wire assembling and hanging of ceiling fan and connecting up to ceiling rose or connector to fan its position using new clamp set (clamp, rubber bush and nut and bolt) including testing complete all as directed

10

98

-

... More
Disconnecting electrical wire of Exhaust fan of size 230 / 300 mm dia and taking down from its position, dismantling blades, cleaning and greasing after removing the blade to make noise free smooth operation including replacement of pvc twin twisted wire assembling and fixing of Exhaust fan and connecting up to ceiling rose or connector to fan its position using new fasening clamp including testing complete all as directed

6

99

-

... More
Supply and fix sheet metal enclosure MCB DB 8 way single pole with neutral for 240 V, fixed flushed on walls including necessary wall cutting and making good disturbed surfaces and blanking plate as per requirement complete all as specified and directed. Note: disturbed area of wall has to finish with cement mortar and match with existing colour of wall, rate of cement mortar and colour are inclusive in quoted rate

6

101

-

... More
Supply and fixing repair anti sucide ceiling fan rod 30cm long with max load capacity of 22Kg fixed with rubber reel nut bolt and quaterpin, complete all as specified and as directed

30

102

-

... More
S&F miniature circuit breaker (MCBs) SPN , 240 Volt, 32 Amps, "C" series,10 KA breaking capacity, complete all as specified and directed

4

102

-

... More
Fixing only MCB SPN 32 Amps complete all as specified and directed (Serviceable MCB obtained shall be reused).

2

103

-

... More
S&F MCB, SP, AC, 240 volts IP-43 of 6 to 32 Amps capacity "C" series and making connections incl taking down unsv one complete all as specified & directed.

24

104

-

... More
Fixing only MCB SP 6 to 32 Amps complete all as specified and directed (Serviceable MCB obtained shall be reused).

12

105

-



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.