Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Provn Of 01 X 100 Kva Transformer For Electric Power Supply Of Tech Bfg Hall Complex And 100 Kva Transformer For Bss (operationally Certain Sensitive Equipment) Of Certain Unit At Missamari Mil Stn in Sonitpur, Assam, with an estimated contract value of Rs. 40,00,000. The bid opening date for this tender is 11-11-2026 and the last date for bid submission is 01-12-2026. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender - Assam Tender

Opening Date11 Nov 2026
Closing Date1 Dec 2026
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Summary

Provn Of 01 X 100 Kva Transformer For Electric Power Supply Of Tech Bfg Hall Complex And 100 Kva Transformer For Bss (operationally Certain Sensitive Equipment) Of Certain Unit At Missamari Mil Stn

Description

Provn Of 01 X 100 Kva Transformer For Electric Power Supply Of Tech Bfg Hall Complex And 100 Kva Transformer For Bss (operationally Certain Sensitive Equipment) Of Certain Unit At Missamari Mil Stn.

AI Insights

Unlock AI Insights for this Tender

Sign in to request AI-powered insights, eligibility criteria and automated analysis for this tender.

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Supply & Fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 metres long) and applying two coats of aluminum paint over a coat of red oxide primer,the embeded portion shall be applied with two coats bituminous paint complete all as specified and as directed.

-

100

-

... More
M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint as complete all as specified and as directed.

-

100

-

... More
M&L for Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed.

-

100

-

... More
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts ofapproved size, for HT11000V, of size (25cmx20cm) complete all as specified and as directed.

-

100

-

... More
Supply and fix lightning arrestor expulsion type complete with all fittings transimission class discharge capacity 65kA suitable for 11000V complete all as specified and as directed.

-

100

-

... More
Supply and install HT 11 KV outdoor type gang operated air-break switch , mechanically operated mounted on insulater and steel frame ,with operating mechanism worked from ground level suitable for horizontal or vertical mounting including drop out fuse having 12 insulators of rating upto 200 Amps complete all as specified and as directed .

-

100

-

... More
M & L for earthing complete with copper Earth Plate Electrode (600mm x 600mm x3.15mm), thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to Copper earth strip (20x3 mm) drawn through and including Galvanised Iron protection Pipe 40 mm bore (dia) Light grade up to height of the transformer foundation where transformer is situated by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150 mm thick PCC Pit in cement concrete (1:3:6) (20 mm graded aggregrate ), Precast RCC (1:2:4) (20 mm graded aggregrate ) cover slab (350 x350 x 50 mm) thick reinforced with and including 8 mm dia TMT Bars @ 10 cm Centre to Centre both ways GI Wire Mesh , Funnel, with GI Watering Pipe 20 mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 metre and all as shown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed.

-

100

-

... More
M & L for earthing complete with Galvanized iron Earth Plate Electrode (600mm x 600mm x6mm), thick buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below Normal Ground Level, connected to Galvanized Iron earth strip (32x6 mm) drawn through and including Galvanised Iron protection Pipe 50 mm bore (dia) Light grade up to height of the transformer foundation where transformer is situated by means of Bolts, Nuts, Check Nuts and Washers etc Earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of not exc 150mm thick PCC Pit in cement concrete (1:3:6) (20 mm graded aggregrate ), Precast RCC (1:2:4) (20 mm graded aggregrate ) cover slab (350 x 350 x 50 mm) thick reinforced with and including 8mm dia TMT Bars @ 10 cm Centre to Centre both ways GI Wire Mesh , Funnel, with GI Watering Pipe 20 mm bore dia Medium grade necessary excavation in soft loose soil returning filling in and removal of surplus soil upto a distance of 50 metre and all as shown in Electrical Plate No. 3 of MES schedule Part- I and testing on completion complete all as specified and as directed.

-

100

-

... More
Supplying and laying un-reinforced precast concrete cable cover class HV, type - I, flat, size (300 x 180 x 40 mm) complete all as specified and as directed.

-

100

-

... More
Design, fabricate ,Supply, installing, testing and commisioning and design of factory made powder coated (CPRI approved) out door type, dust & vermin proof, LT feeder piller box made out of 3.15 mm thick CRCA steel sheet of suitable size and and angle iron (50x50x6mm), grouted in PCC M-10 using 20mm graded stone aggregate including bus bar, internal wiring with PVC insulated, single core copper conductor cable of suitable size duly numbered with tags for the circuits with hinged double door shutters (front & rear), cubical type with locking arrangement and slanted roof. The size of panel board shall be 3 phase, 440VAC, 50Hz supply system. the panel board shall comprise of following items and all specified in SSR part -I clause No 19.21 and connecting up all the LT UG cables. Busbar: 250 Amps rated copper busbar TPN duly insulated with PVC Sleave asper standard colour code and rigidly mounted on backalite/ DMC insulated bus bar support ((square/ round) insulators of suitable size and good insulation resistance. Note:- The LT Panel shall be manufactured by CPRI approved Manufacturer and typed test certificate of the LT Panel to be submitted: - (a) INCOMING (i) MCCB 125 Amps, 4 pole, 415V, 35 KA- 2 Nos Make Seimens/Schneider/L&T/Legrand (ii) Change Over Switch 125 Amps 4 pole, 415 V Make Seimens/Schneider/L&T/Legrand (iii) Digital ammeter with 3 Nos CTs & Selector switch - 1 Set (iv) Digital Voltmeter with selector switch - 1 Set (v) R, Y, B indicator Lamps 1 Set (b) OUTGOING (i) MCCB 100 Amps, 4 pole, 415V, 25 KA- 01 Nos Make Seimens/Schneider/L&T/Legrand (ii) MCCB 63 Amps, 4 pole, 415V, 25 KA- 01 Nos Make Seimens/Schneider/L&T/Legrand

-

100

-

... More
Supply, lay, & testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size: - (a) 95 sq mm 3½ core (Transformer to LT Panel)

-

100

-

... More
Supply, lay, & testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 50 Sqmm 4 Core.

-

100

-

... More
Supply only chain link MS Zink coating 60gsm as per IS 4826 fencing of 75mm mesh size and 4mm dia or wire complete all as specified and as directed.

-

100

-

... More
M & L for cement concrete type C2 (1:3:6) 40 mm graded aggregate for foundation to poles complete all as specified and as directed.

-

100

-

... More
M & L for PCC in flooring ,filling and mass concrete type C2, 40mm graded aggregate (1:3:6) for flooring of size (9m x 9m x 0.05 m) complete all as specified and as directed (for Sub station yard).

-

100

-

... More
M & L for filling of flooring of 40 mm graded coarse stone gravel for floorimg of size (9m X 9m X 0.1m) complete all as specified and as directed (For sub station yard).

-

100

-

... More
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations etc, or for shafts, wells, cesspits, man holes, pier holes etc not exc 10 sq m on plan and getting out in soft / loose soil complete all as specified and as directed.

-

100

-

... More
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed.

-

100

-

... More
Removing excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.

-

100

-

... More
Material and labour for sand cushioning for cable protection using clean dry sand complete all as specified and as directed.

-

100

-

... More
Supply & Laying well burnt brick, locally available best quality (sub class "B" bricks ) laid in trences perpendicular to UG Cable protection complete all as specified and as directed.

-

100

-

... More
Supply laying & fixing GI Pipe light 80mm dia , ISI marked ,of required length for protection of cables in wall/pole/under road complete including necessary MS clamps , nuts , bolts & washers etc complete all as specified and as directed.

-

100

-

... More
S & F GI Tubing light grade of size 50mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clam as per site requirement etc complete all as specified and as directed.

-

100

-

... More
S & F Mild steel bars 10mm dia Fe-410-W (Gde.E-250) Part- I quality-A or Fe 290 (Gde - E-165) and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.

-

100

-

... More
Supply, lay, & testing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size: - (a) 120 sq mm 3½ core (Transformer to LT Panel)

-

100

-

... More
All as per item no 28 above same here but with 70 sq mm 3½ core ( LT Panel to Bfg Room)

-

100

-

... More
Supply and fix expulsion fuse, Triple pole, channel type/drop out type suitable as per site reqmt with working pressure 11 KV grade of capacity upto 200 Amps complete all as specified and as directed ( With Six insulator)

-

100

-

... More
M&L Heat shrinkable end jointing kit (outdoor type) suitable for 1100 volts grade LT under ground cable of Sizes from 70 to 150 sqmm 3.5 core as per requirement at site complete all as specified and as directed .

-

100

-



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.