The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repair Maintenance Of Street Light, High Mast And Perimeter Lights At Air Force Station Tezpur Under Ge Af Tezpur in Sonitpur, Assam, with an estimated contract value of Rs. 40,00,000. The bid opening date for this tender is 17-05-2025 and the last date for bid submission is 07-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 May 2025
Closing Soon7 Jun 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Horizontal boring of holes by mechanical means, at under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 80 to 100 mm bore, galvanised steel tubing,and making good distrubed surfaces as per existing specification complete all as specified and directed. Note : GI pipe of dia 80 mm & 100mm will be measured & paid separately under respective items.

18

100

1800

... More
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid for).

19.16

100

1916

... More
Taking down/out unserviceable or serviceable LT UG cables of nominal cross sectional area 35 Sqmm 3.5 core and connections including bricks, GI Pipes, etc. of any descriptions, laid in trenches and/ or fixing with walls/ poles including segregating of serviceable materials viz bricks, cables, GI pipes, etc. and keep in safe custody for re-use, complete all as directed.

120

100

12000

... More
All as per serial item No.6 here-in-before, but nominal cross sectional area 25 Sqmm 4 Core.

150

100

15000

... More
All as per serial item No.6 here-in-before, but nominal cross sectional 16 Sqmm 4 Core.

200

100

20000

... More
All as per serial item No.6 here-in-before, but nominal cross sectional 10 Sqmm 2 Core. (NOTE for Serial item No.6 to 9 : Earth work shall be measured and paid separately under relevant Items).

150

100

15000

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.

90

100

9000

... More
All as per serial item No.10 here-in-before, but nominal cross sectional 25 Sqmm 4 Core.

100

100

10000

... More
All as per serial item No.10 here-in-before, but nominal cross sectional 16 Sqmm 4 Core.

150

100

15000

... More
All as per serial item No.10 here-in-before, but nominal cross sectional 10 Sqmm 2 Core.

150

100

15000

... More
Re-laying/ fixing or passing through pipe, XLPE insulated, armoured, electric power UG cable (heavy duty) with aluminium conductor, 1100 volt grade, nominal cross sectional area 35 Sqmm 3½ core core including brass compression cable gland, terminal lug, etc. complete all as directed.

30

100

3000

... More
All as per serial item No.14 here-in-before, but nominal cross sectional 25 Sqmm 4 Core complete all as directed.

50

100

5000

... More
All as per serial item No.14 here-in-before, but nominal cross sectional 16 Sqmm 4 Core complete all as directed. NOTE : For item Nos. 14 to 16 : Old serviceable UG cable obtained from serial item Nos. 6 to 9 to be reused.

50

100

5000

... More
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.

3.12

100

312

... More
Re-laying only old Brick in Trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 1 here-in-before), complete all as directed.

1.2

100

120

... More
Cutting chase for pass through cable protection pipe ,etc.in existing plain cement concrete pavement/ hardstanding/aprons etc. and making good, cutting in plain cement concrete (1:3:6) Type C1(using 20 mm graded aggregate),exceeding 20 cm but not exc 50 cm girth, complete all as specified and directed.

20

100

2000

... More
Taking down/ out unserviceable GI/ HDPE/ Polyethylene flexible pipes of any descriptions, laid in trenches and/ or fixing with walls/ poles complete all as specified and directed.

48

100

4800

... More
S&F Galvanised Iron Pipe 50mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. Make : JINDAL/BANSAL/NTL.

18

100

1800

... More
Material and labour for, galvanised iron pipe 40mm bore (dia) ‘light grade’ for protection of UG cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc., complete all as specified and directed.

18

100

1800

... More
Material and labour for, galvanised iron pipe 32mm bore (dia) ‘light grade’ for protection of UG cable, laid in floors/ road crossing, fixing to pole with mild steel clamps, nuts, bolts, etc., complete all as specified and directed.

12

100

1200

... More
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 25 sq. mm to 50 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0130 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]

6

100

600

... More
Materials and Labour for,street light bracket arm made out of 40 mm bore, medium grade, galvanized steel tubing 1.50 M long bent to shape required and two pairs of FI clamps made out of FI 25 mm X 3 mm, with nuts bolts washer suitable for fixing the bracket arm to top of steel/PSC pole,including taking down existing unserviceable street light bracket,complete all as specified and directed.

30

100

3000

... More
Materials and Labour for,street light bracket arm made out of 25 mm bore, medium grade, galvanized steel tubing 1.50 M long bent to shape required and two pairs of FI clamps made out of FI 25 mm X 3 mm, with nuts bolts washer suitable for fixing the bracket arm to top of steel/PSC pole,including taking down existing unserviceable street light bracket,complete all as specified and directed.

50

100

5000

... More
Supply and laying or fixing or passing through pipe,PVC insulated, sheathed, unarmored multi stranded copper conductor cable, 3 core, 1.5 Sq mm size,1100 Volts grade, in connection to street light/flood light fittings from control box,including taking down existing unserviceable cable,complete all as specified and directed.

500

100

50000

... More
Supply and Fix in repair, Cable Junction Box, IP66 ‘halogen free and weather proof’, size 155 mm (W) x 210 mm (H) x 92 mm (D), with knock outs for cable entry for cable size 10-16 sq mm with 03 (Three) Nos.Grommets, IP 65, cable entry M 32, all as per Cat No. DK 1616 G & Cat No.EDK 32 (For Grommets) of Make “Hensel” or equivalent Model of Make ‘Sintex Industries Ltd’/'C&S Electric Ltd',fixed to wall/ pole with suitable aluminium strip clamp 25 X 3 mm, nuts, bolts and washers, including provision of 15 Amps,4 pole,open bakelite terminal block connector, complete all as specified and directed.

35

100

3500

... More
Supply and Fix in repair, Cable Junction Box, IP66 ‘halogen free and weather proof’, size 130 mm (W) x 180 mm (H) x 77 mm (D), with knock outs for cable entry for cable size 10-16 sq mm with 03 (Three) Nos.Grommets, IP 65, cable entry M 32, all as per Cat No. DK 1010 G & Cat No.EDK 32 (For Grommets) of Make “Hensel” or equivalent Model of Make ‘Sintex Industries Ltd’/'C&S Electric Ltd',fixed to wall/ pole with suitable aluminium strip clamp 25 X 3 mm, nuts, bolts and washers, including provision of 15 Amps,4 pole,open bakelite terminal block connector, complete all as specified and directed.

10

100

1000

... More
Supply and fix in replacement of decorative LED post top 40 watt fittings IP-65 protection including with all accessories complete along with GI pipe of 40mm dia (light grade) of 0.5m length shall be fixed on the post top lantern including all necessary PCC works including taking down old unserviceable light fittings, complete all as specified and directed. Make: Crompton (Cat No. LPTO-40-CDL) or equivalent model of make as specified in PS.

10

100

1000

... More
Supply and fix in replacement garden light fitting with inverted pyramid tripod type LED bollard with soft 360 degree light 10 watts including foundation for the fittings of sizes 250 X 250 X 450 mm with PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate), after taking down old unserviceable light fittings, complete all as specified and directed. Make: Crompton (Cat No. LBLSN-10-CDL) or equivalent model of make as specified in PS.

12

100

1200

... More
S & F LED street lights nominal power 30 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 3600, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with LED life with L70 criteria and IK 10 including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge with and including taking down old unserviceable complete . Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services. . Make Philips/Wipro/Orient electric

30

100

3000

... More
S & F LED street lights nominal power 45 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 5400, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with LED life with L70 criteria and IK 10 including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge with and including taking down old unserviceable complete . Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services. . Make Philips/Wipro/Orient electric

42

100

4200

... More
S & F LED street lights nominal power 60 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 7200, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with LED life with L70 criteria and IK 10 including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge with and including taking down old unserviceable complete . Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services. . Make Philips/Wipro/Orient electric

60

100

6000

... More
S & F LED street lights nominal power 70 Watt, LED of Make Osram; Bridge Lux ; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 8400, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with LED life with L70 criteria and IK 10 including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge with and including taking down old unserviceable complete . Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services. . Make Philips/Wipro/Orient electric

90

100

9000

... More
S & F LED flood lights nominal power 120 Watt, LED of Make Osram; Bridge Lux; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with L 70 and IK 10 Make mentioned under particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge with and including taking down old unserviceable complete . . . Make Philips/Wipro/Orient electric

12

100

1200

... More
S & F LED flood lights nominal power 150 Watt, LED of Make Osram; Bridge Lux; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with L 70 and IK 10 Make mentioned under particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge with and including taking down old unserviceable complete .

20

100

2000

... More
S & F LED flood lights nominal power 200 Watt, LED of Make Osram; Bridge Lux; Philips; Nicha; Cree; LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 70%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 burning hours with L 70 and IK 10 Make mentioned under particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 with and including taking down defective light fitting from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding and safety measures complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge with and including taking down old unserviceable complete .Note : Note for Item No. 32 to 38 :- (i) It is mandatory that contractor shall submit the insurance certificate minimum 5 Lakh sum assured of all staff/employee employed by him for the work services. (ii) At location where light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt. (iv)All LED lights have replacement warranty of 3 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of 3 year replacement warranty certificate. (v) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly. (vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries. (vii) All LED fitting shall be identified by printing or fixing stickers duly mentioned the C.A number and date of completion. (viii) For any change in product or change in catalogue No. etc due to technological upgradation, letter has to be obtained from the lighting company on their letter head signed by an offical of National level. (ix) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor.(X) If the clamp is not provided by manufacturer,s , it shall be the responsibility of the contractor to provide the same and the cost for the same is deemed to be included in the quoted rate.

20

100

2000

... More
Supply and Fix in repairs,time switches with 150 hours battery backup,FM1/Quartz Daily,240VAC Base/DIN Mounting,complete all as specified and directed. [Cat No.AUTS03ANA00 of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB]

5

100

500

... More
Supply and Fix in repairs,time switches with 150 hours battery backup, Digital type, ,complete all as specified and directed. [Cat No.AUTS02DIG00 of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB]

5

100

500

... More
Supply and Fix in repairs,3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX, AC-3 rating 40 Amps and AC-1 rating 55 Amps, complete all as specified and directed. [Cat No.CS94190 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ABB]

10

100

1000

... More
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 63 Amps and 10 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed.

10

100

1000

... More
M&L for Earthing complete with Galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground with earth pit not less than 3.25 meter deep below ground level with top edge of plate not less than 2.5 meter below normal ground level connected to galvanised iron strip 32x6 mm as earth lead strip by means of nuts, bolts, check nuts, washers of galvanized iron as steel all as shown electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and elctrode by means of steel and GI pipe light grade 20mm bore dia bore for watering funnel with wire mesh, CI cover with frame , PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified. NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI strip of 32x6 from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate

5

100

500

... More
Comprehensive maintenance for a period of Six (6) months existing high mast lighting system by disconnection of electrical connections,taking down carefully the winch drive assembly of lantern carriage,cleaning of steel wire rope,drive chain,drive gears,winch drum etc.,re assembelying the winch drive assembly,re- connection of electrical connections including lubricating steel wire rope,drive chain,drive gears,winch drum etc.including oil bath with fresh lubricants as per OEM's instructions,& connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.. Note :- Spares for replacement will be measured and paid seperately under respective items of this BOQ.

12

100

1200

... More
Supply Only,6 mm dia.,7/19 construction stainless steel wire rope (Grade AISI 316),breaking load capacity 2350 Kgs, as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.

120

100

12000

... More
Supply Only,gear pinion (02 + 02 =4 Nos.) suitable for winch drive mechanism of high mast lighting system as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. [OEM of High Mast Lighting System:-Crompton/Bajaj]

12

100

1200

... More
Supply Only,drive chain suitable for winch drive mechanism of high mast lighting system as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.. [OEM of High Mast Lighting System:-Crompton/Bajaj]

12

100

1200

... More
Supply Only, MS Jubilee Clamp, 25 mm (16 Nos.) suitable for high mast lighting system as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.. [OEM of High Mast Lighting System:-Crompton/Bajaj]

12

100

1200

... More
Dismantaling of winch drive motor, 3 Phase, 1 HP capacity,from double drum winch drive assembly of high mast lighting system, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding motor with super enamelled copper wires of existing size/gauge including provision of all insulating materials,lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling,including testing and commissioning, as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. [OEM of High Mast Lighting System:-Crompton/Bajaj]

6

100

600

... More
Repair of unserviceble LED Light on the pole/ building/ watch tower/ sunshelter by refreshing of connection, changing of connector, changing of wire, tighting of wire on ACSR conductor etc., complete all as specified and directed. Note:(i) Cost of connector and suitable size of Copper/ aluminium wire up to 1.5 metres shall be measured in quoted rate. (ii) Supervisor shall take complain from power house on daily basis.

790

100

79000

... More
Disconnecting electrical connections,taking down carefully existing unserviceable LED street light fitting and LED flood light luminaries from pole/building/watch tower/masts/ sunshelter etc. dismantling of parts,replacement of unserviceable spares as required, reassebling after repairing/replacement of the same and re-fixing in the original position,reconnection of electrical connections,testing and commissioning,complete all as specified and directed. Note :- Spares will be measured and paid for sepeerately under respective items of this BOQ.

220

100

22000

... More
Supply only for, LED driver for security lights of 25 watts, all as per OEMs specifications. [Make:-Philips/Bajaj/Crompton/Wipro/GE]

30

100

3000

... More
Supply only LED driver suitable for 45 watts open type, all as per OEMs specifications. [Make:-Philips/Bajaj/Crompton/Wipro/GE]

60

100

6000

... More
Supply only LED driver suitable for 70/ 75 watts open type, all as per OEMs specifications. [Make:-Philips/Bajaj/Crompton/Wipro/GE]

60

100

6000

... More
Supply only LED driver suitable for 120/ 150 watts open type, all as per OEMs specifications. [Make:-Philips/Bajaj/Crompton/Wipro/GE]

35

100

3500

... More
Supply only LED driver suitable for 200 watts open type, all as per OEMs specifications. [Make:-Philips/Bajaj/Crompton/Wipro/GE]

20

100

2000

... More
Supply only surge protection devices of capacity 5KV for industrial and outdoor LED fixtures with rated power above 75 watts and upto 150 watts,all as per OEMs specifications. [Make:-Philips/Bajaj/Crompton/Wipro/GE]

15

100

1500

... More
Supply only surge protection devices of capacity 10 KV for industrial and outdoor LED fixtures with rated power 200 watts, all as per OEMs specifications. [Make:-Philips/Bajaj/Crompton/Wipro/GE]

15

100

1500

... More
Supply, installation, commissioning and testing of street light panel (out door type) 3 Phase, 415 volt 6 KW, digital type timer, contactor rating 32 Amps TP, including MCB TPN suitable size as per Havells Cat No IHXTS03060. The panel to be fitted on MS angle frame of size 50x50x5mm with a height of 0.5 metre including PCC foundation (1:2:4) type B1 (using 20mm graded crushed stone aggregate), including painting to all, complete all as specified and directed.

2

100

200

... More
M & L Painting of steel pole (swan neck type or straight type) up to 12 mtr height with cross arms, clamp of any length and shape for LT overhead line/ for street light with two coat of aluminium paint after scraching out old paint, cleaning and exiting surface rust free, preparation of the existing surface, including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker, including painting strips in alternate from bottom to top with three strips of black syenthatic paint & two strips of Yellow/ Sky blue paint (as per existing pattern through out the circumference of pole, including removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on PCC copping of pole complete all as specified and directed.

325

100

32500

... More
M & L Painting to the LT PCC poles up to 12 mtr height with strips in alternate from bottom to top with three strips of black synthatic paint & two strips of Yellow/ Sky blue paint (as per existing pattern) through out the circumference of pole including one coat of lime wash on PCC copping of pole , two coat of white colour cement base paint on pole and two coat of aluminium paint to channels, cross arm, clamps and pipes fixed/ mounted on pole after scraching out old paint, cleaning and making exiting surface rust free, preparation of the existing surface, including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ stricker complete all as specified and directed.

50

100

5000

... More
Repairing of electric pole coping by dismantling of PCC, welding of electric pole by using three Nos. angle of 500 mm length and size 40 x 5 mm around the pole including applying two coats of black colour synthetic enamel paint over a coat of red oxide primer and making the coping of size 450 mm x 450 mm x 450 mm with suitable slop with PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) complete all as specifed and directed.

5

100

500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.