Military Engineer Services Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date6 Jan 2025
Closing Soon27 Jan 2025
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed

10

-

-

... More
B/R WORKS

-

-

-

... More
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed

14.5

-

-

... More
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for and removal of debris complete all as specified and as directed

0.2

-

-

... More
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed

436.8

-

-

... More
Demolition of reed, lathing, single or double including battens and plaster or chiken wire lathing complete all as specified and as directed

260

-

-

... More
Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc. complete all as specified and as directed

602

-

-

... More
Dismantling rain water pipe and sewage line pipe of any type and any size including fitting complete all as specified and as directed

12

-

-

... More
Dismantling wooden boarding (eaves board, rafter, etc.) of any description fixed in any position with nails complete all as specified and as directed

59

-

-

... More
Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed

2.8

-

-

... More
Dismantling of timber scantling 40sqcm and over in section, in any position in unframed works complete all as specified and as directed

3.27

-

-

... More
Dismantling of timber fillets rails, posts, rafters, purlins, etc. under 40sqcm in section, in any position in unframed works complete all as specified and as directed

60

-

-

... More
Dismantling wall and ceiling boards (fibre, pulb, insulation, etc.) or insulation boards slabs/blankets of any thickness including cover fillets complete all as specified and as directed

261

-

-

... More
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed

2.7

-

-

... More
Taking down cement or cement/lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed

170

-

-

... More
Taking down chowkats or frames not exceeding 1.5sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces

33

-

-

... More
Taking down chowkats or frames exceeding 1.5sqm but not exceeding 4.0sqm each with shutters (without taking off shutters from the frame), disposing off and making good the disturbed areas, portions and surfaces

17

-

-

... More
Taking up or down 15mm bore steel water tubing and connections from any location / position including sorting, stacking, cleaning serviceable pipes and disposing off other, etc. complete all as specified and as directed

6

-

-

... More
Taking up or down 20mm bore steel water tubing and connections from any location / position including sorting, stacking, cleaning serviceable pipes and disposing off other, etc. complete all as specified and as directed

24

-

-

... More
S&F in position steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer, etc. using ERW or induction butt welded tubes / SHS conforming to IS-1161-2014 / IS-4923-1997 grade St-240 complete all as specified and as directed

200

-

-

... More
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 grade E-165 complete all as specified and as directed

160

-

-

... More
S&F bands, straps, hold fasts, wall ties, two way and three way straps, plate washers and similar articles of mild steel 25x5mm conforming to Fe-290 grade E-165 complete all as specified and as directed

150

-

-

... More
S&F of mild steel rolled sections as in main and cross beams, hip and jack rafters, purlins, brackets for fixing of eaves board, posts, etc. where connected to common rafters and other miscellaneous brackets fixed with angle cleats or other connecting plates conforming to Fe-290, grade E-165 complete all as specified and as directed

145

-

-

... More
S&F plates (plain or chequered) channels, square cut or notched (ordinay and counter sunk) forming holes, without any attachment of Fe 410W grade-E -250, quality 'B' complete all as specified and as directed

5

-

-

... More
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed

450

-

-

... More
M&L for mild steel TMT bars grade Fe-500D, 8mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed

325

-

-

... More
M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders securing with clips complete all as specified and as directed

160

-

-

... More
M&L for formwork to sides and soffits of floor or roof beam, beam haunching, girder, lintels, cantilever, shelves including supports, etc. for rough finished flat surfaces of concrete complete all as specified and as directed

28

-

-

... More
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and as directed

2

-

-

... More
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in beams, cantilevers, lintels, etc. over 1.5m long complete all as specified and as directed

1.55

-

-

... More
M&L for providing RCC (nominal mix) 1:1.5:3 type A1 using 20mm graded aggregates as in columns, posts, piers, pillars, struts, etc. complete all as specified and as directed

0.2

-

-

... More
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed

1.2

-

-

... More
M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregates) as in sub-bases for floors, complete all as specified and as directed

60

-

-

... More
M&L for 75mm thick plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in floors, plinth protection, pavings, etc. surface finished even and fair, laid in alternate bays/panels and joints filled with bituminous mix of 1 part bitumen and 3 part of sand complete all as specified and as directed

72

-

-

... More
M&L for 100mm thick PCC 1:3:6, type C-2, using 40mm graded aggregates as in bases for floors, etc. finished fair and even complete all as specified and as directed

6

-

-

... More
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in bed blocks, back filling of steel frame and holdfasts, etc. including necessary formwork complete all as specified and as directed

0.93

-

-

... More
M&L for plain cement concrete 1:3:6 (type C-1) using 20mm graded stone aggregate as in beds of drains, surface channels, foundations of manholes, etc. complete all as specified and as directed

4.6

-

-

... More
M&L for extra in forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc. complete all as specified and as directed Note: Inner girth shall only be measured

90

-

-

... More
Add or deduct for each 25mm girth or part thereof over or under 30cm (for adjustment in girth in item No. 26 hreinabove)

11

-

-

... More
M&L for brickwork with sub-class 'B' bricks (old size bricks), straight or curved on plan exceeding 6m mean radius built in CM (1:6) complete all as specified and as directed

1.3

-

-

... More
M&L for brickwork with sub-class 'B' bricks, straight or curved on plan to any radius as in half brick thick walls built in CM (1:4) complete all as specified and as directed

268

-

-

... More
S&F pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one or more rebates including hinges (100/50mm stainless steel), lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of aldrop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs, etc. complete all as specified and as directed

41

-

-

... More
S&F pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door and window frames with one or more rebates including hinges (100/50mm stainless steel), lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of aldrop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs, etc. complete all as specified and as directed

16

-

-

... More
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, smooth finish with lipping of teak wood on edges complete all as specified and as directed

7.8

-

-

... More
S&F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, smooth finish with lipping of teak wood on edges complete all as specified and as directed

8

-

-

... More
S&F factory fabricated solid PVC moulded door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with but 2mm thick moulded prelam PVC sheet on the front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed

5.4

-

-

... More
S&F 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge, etc and divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, sizes of members of shutters as specified in clause 8.20 9(b) of SSR Part-I, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., supplied and fitted to chowkats complete all as specified and as directed

6

-

-

... More
S&F 2nd class hard wood 50mm thick boarding, wrought, fixed with nails in any position (except flooring and skirting) with butt joints complete all as specified and as directed

2

-

-

... More
M&L for 2nd class hardwood fillets square, rectangular or tringular in section clean sawn screwed with nails exceeding 13sqcm and not exceeding 25sqcm in section complete all as specified and as directed

20

-

-

... More
M&L for 2nd class hard wood plain fillets, square, rectangular and triangular in section, wrought, bull nosed, splayed, chamfered or rounded on one edge or face, sectional area exceeding 6sqcm but not exceeding 13sqcm complete all as specified and as directed

65

-

-

... More
M&L for 2nd class hard wood timber scantling clean sawn in section, timber and fixed complete all as specified and as directed

1.27

-

-

... More
S&F 2nd class hard wood pieces, small let in for making good where hinges, etc. have been removed from chowkhats or frames, joinery, etc. including painting or oiling to match, if required complete all as specified and as directed

10

-

-

... More
S&F steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast including suitable locking arrangements complete all as specified and as directed

4

-

-

... More
S&F steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete with glazing bars, dovetailed or welded, including suitable locking arrangements complete all as specified and as directed

14

-

-

... More
S&F steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete without glazing bars, dovetailed or welded, including suitable locking arrangements complete all as specified and as directed

14

-

-

... More
S&F powder coated aluminium (minimum thickness of powder coating 50micron) for door, windows and ventilators, any pattern, with frame, with hinges, side locks, rollers, EPDM rubber/neoprene gaskets for sliding windows, extruded built up standard tubular sections/appropriate Z sections conforming to IS: 733 and IS: 1285, fixed with dash fasteners of required dia and size, including necessary filling up of gaps with at junctions with gaskets, sections shall be smooth, mitred and jointed mechanically including cleat angle, aluminium snap beading for glazing / paneling and all fittings / fixtures complete all as shown on drawings, as specified and as directed Note: All fittings, etc. as per drawing shall be deemed to be included in the quoted rate and glass / wire mesh will be measured and paid separately

180

-

-

... More
M&L for aluminium anodised (minimum thickness of anodising shall be 15microns), white or tint as approved, grill of design DG-104 pattern (10X5.2mm), fixed with anodised aluminium 'F' sections (20.6x15.2x1mm) to aluminium window / ventilators, etc all as per manufacturer's instructions complete all as specified and as directed

15

-

-

... More
S&F 3mm thick sheet glass ordinary quality and glazing with oil putting square not exceeding 0.5sqm in each pane including hacking out old glass complete all as specified and as directed

16.5

-

-

... More
S&F 4mm thick sheet glass ordinary quality and glazing with oil putting square not exceeding 0.5sqm in each pane complete all as specified and as directed

12

-

-

... More
S&F 4mm thick sheet glass ordinary quality and glazing with oil putting square exceeding 0.5sqm in each pane complete all as specified and as directed

4

-

-

... More
S&F 4mm thick frosted glass ordinary quality and glazing with oil putting square not exceeding 0.5sqm in each pane complete all as specified and as directed

0.6

-

-

... More
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed

24

-

-

... More
M&L for 12mm thick pre-laminated particle board, exterior grade, prelaminated on both sides with decorative choice lamination and other side balancing white lamination complete all as specified and as directed

1.9

-

-

... More
Cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10cm in girth complete all as specified and as directed

2

-

-

... More
Supplying, fixing / laying steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings viz. bends, elbows, tees, short pieces, connectors, backnuts, diminishing pieces, caps, plugs, unions, flange, etc. ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches for water connections including all necessary welding, etc. as required at site complete all as specified and as directed for the following bores:

-

-

-

24

-

-

... More
S&F 3 layer 20mm outer ida PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches or fixed on wall etc, complete all as specified and as directed.

6

-

-

... More
S&F in repairs gun metal globe or gate valve, 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, breaking/cutting into cement concrete, masonry, etc. and making good the disturbed surfaces complete all as specified and as directed

2

-

-

... More
S&F in repairs vitreous China wash down water closet pan (Pedestal pattern), coloured (as approved), with 'P' or 'S' trap, including flush pipe, trap, connection to drain or outgoing pipe, anti-syphonic pipe, seat cover to match with colour of WC, closed pattern with flat bottom & cover and chromium plated mild steel or aluminum anodized hinge device and jointing and connecting up complete all as specified and as directed

2

-

-

... More
S&F in repairs vitreous China urinal, bowl type full stall urinal flat back, of size 375x390x590mm white, with grating and union for discharge pipe (back or corner wall type), including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in white cement, fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed

2

-

-

... More
S&F in repairs vitreous China bowl type urinal, flat back, of size of 465x355x265mm, white with grating and union for discharge pipe (back or corner wall type), including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal with plugs with 60mm long brass screws, pointing around urinal back in cement, with and including and fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed

1

-

-

... More
S&F in repairs wash hand basin, vitreous China, white, counter top type, of size 560x461mm, oval shaped, of approved design, with waste coupling and including PVC connection 60cm key with brass union complete all as specified and as directed

2

-

-

... More
S&F in repairs wash hand basin, vitreous China, ,angle back type, of size 600x480mm, including CI brackets, cutting for and pinning in ends of brackets with coupling and including PVC connection 60cm key with brass union complete all as specified and as directed

1

-

-

... More
S&F 10litres capacity PVC flushing tank, white / coloured, syphonic action type, low level, valveless, with PVC inlet ball valve, PVC flush pipe, float and suitable sized brackets including cutting of floor / wall and making good to the disturbed surfaces in CM 1:3 with finishes to match with the existing and taking down of old PVC flush tank and disposing off complete all as specified and as directed

5

-

-

... More
S&F 15mm dia pillar taps, fancy type, cast copper alloy, with capstain heads, chromium plated, screwed down, high pressure, with or without lettered 'HOT'/'COLD', with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed

3

-

-

... More
S&F in repairs 15mm dia stop cocks / angle valves, cast copper alloy, screwed down, long shank, high pressure, with crutch or butterfly handle, concealed type, screwed both ends for iron pipe or for unions or for brass ferrule complete all as specified and as directed

11

-

-

... More
S&F in repairs 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed

7

-

-

... More
S&F in repairs health faucet, 15mm bore, brass head chromium plated, telephone type, with CP arms, flexible pipe (ABS body) with 1.2m long stainless steel flexible braided hose tube and wall hook of approved finish complete all as specified and as directed

2

-

-

... More
S&F in repairs 15mm PVC connections, 450mm long with brass couplings, PTMT nuts, etc. complete all as specified and as directed

11

-

-

... More
S&F brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed

2

-

-

... More
S&F in repairs towel rail, 20mm dia, brass chromium plated, 600mm long with fancy type with brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs complete all as specified and as directed

4

-

-

... More
S&F in repairs bevelled edge mirror of selected quality glass and approved design, fixed to wooden plugs with chromium plated brass screws and cup washers / hinges, etc. complete all as specified and as directed

2.5

-

-

... More
S&F in repairs 600x450mm full sized bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed

1

-

-

... More
S&F PVC (SWR) pipes, 110mm bore, single socketed in any length with rubber ring joints laid in trenches, floors/fixed on wall etc. complete all as specified and as directed

6

-

-

... More
S&F in repairs PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints fixed on walls/laid in trenches with suitable clamps, etc. complete all as specified and as directed

6

-

-

... More
S&F in repairs PVC (SWR) pipes, 40mm bore, single socketed in any length with rubber ring joints fixed on walls/laid in trenches with suitable clamps, etc. complete all as specified and as directed

7

-

-

... More
S&F in repairs 110mm bore PVC (SWR) bend of any radius complete all as specified and as directed

2

-

-

... More
S&F in repairs 75mm bore PVC (SWR) bend of any radius complete all as specified and as directed

2

-

-

... More
S&F in repairs 110mm bore PVC (SWR) junction single T equal or unequal complete all as specified and as directed

2

-

-

... More
M&L for preparation of masonry / concrete wall surfaces and applying 1mm thick wall care putty in two layer rubbed with sand paper for making surface smooth and even including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed

913

-

-

... More
M&L for rendering 10mm thick in cement mortar (1:6) on fair surfaces of PCC block / brick masonry wall / concrete surfaces, etc. finished fair and even without using extra cement complete all as specified and as directed

560

-

-

... More
M&L for rendering 5mm thick in cement mortar (1:3) on fair surfaces of concrete surfaces of ceilings, soffits of slabs, etc. finished fair and even without using extra cement complete all as specified and as directed

3

-

-

... More
M&L rendering 15mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. in two layers (10+5mm) finishing layer mixed with integral water proofing compound @3% by weight of cement, finished even and smooth without using extra cement complete all as specified and as directed Note: WPC will be measured and paid separately under respective item herein

220

-

-

... More
M&L rendering 15mm thick, in cement mortar (1:4) on walls / concrete surfaces, etc. finished even and fair without using extra cement complete all as specified and as directed

10

-

-

... More
Supply only integral water proofing compound all as specified

17.53

-

-

... More
S&F 150mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed

14

-

-

... More
S&F 125mm extruded aluminum alloy handles, cast type, anodized complete all as specified and as directed

14

-

-

... More
S&F 150mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed

13

-

-

... More
S&F 200mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and as directed

10

-

-

... More
S&F in repairs 300mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed

1

-

-

... More
S&F in repairs 250mm aluminium anodised sliding door bolt with hasp and staple, bolt type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and as directed

4

-

-

... More
S&F in repairs door closer hydraulically regulated, designation No. 3 universal type of aluminium (extruded section body) of weight 61 to 80kg, suitable for door shutters of 851-1000mm in width complete all as specified and as directed

5

-

-

... More
S&F 150mm floor door stopper aluminium alloy body and tongue, anodized with hard drawn steel spring fixed on floor complete all as specified and as directed

8

-

-

... More
S&F in repairs 25mm dia fancy type chromium coated (tint as approved) MS curtain / drapery rods, etc. of rod wall thickness 1mm (min), including pair of CP MS brackets, holders with funnel at ends complete all as specified and as directed

22

-

-

... More
M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600x600mm with main runner 38x24mm and wall angle 24x24mm using 4mm thick high pressure non-asbestos fiber cement decorative board (E-Board Classic) in grid of GI system duly suspended from 4mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from roof with adjustment clips, providing positions for light fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detectors, etc., cnforming to IS 14862, the main runners duly secured to structural soffits by hanger @1220mm c/c (maximum) with the last hanger at the end of each main runner not interlocked between main runners @610mm c/c so as to form 600x600mm grid complete all as specified and as directed

261

-

-

... More
M&L for preparation of old plastered or unplastered treated / untreated ceiling surfaces by scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots, etc. with steel wire including brooming down and applying two coats of white wash complete all as specified and as directed

100

-

-

... More
M&L for preparation of old plastered or unplastered treated / untreated wall surfaces by scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots, etc. with steel wire including brooming down and applying two coats of white wash complete all as specified and as directed

46

-

-

... More
M&L for preparation of new masonry / concrete ceiling surfaces and applying three coats of white wash including all necessary staging, etc. as required complete all as specified and as directed

40

-

-

... More
M&L for preparation of new plastered or unplastered wall surfaces and applying two coats of oil bound distemper complete all as specified and as directed

320

-

-

... More
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of primer on wall,complete all as specified and as directed

88

-

-

... More
M&L for preparing of old steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed

33

-

-

... More
M&L for preparing of new steel / metal surfaces of any description not exc. 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed

79

-

-

... More
M&L for preparing of new steel / metal surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed

16

-

-

... More
M&L for preparing of new wood / wood based surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed

30

-

-

... More
M&L for preparing of new wood / wood based surfaces of any description not exc. over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed

5

-

-

... More
M&L for preparation old wooden surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed

30

-

-

... More
M&L for preparation old wooden surfaces of any description not exc. 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, tint as approved complete all as specified and as directed

25

-

-

... More
M&L for complete removal of existing treatment and preparing plastered surfaces and applying two coats of oil emulsion distemper (tint as approved) over a coat of wall primer including all necessary staging, scaffolding, etc. as required to work at heights, etc. complete all as specified and as directed

262

-

-

... More
M&L for preparation of new plastered surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungus resistant, dirt resistant, exterior paint (of approved tint, company depot tinted) with silicon additives @1.43litre/10sqm over a priming coat of exterior primer applied @0.90litre/10sqm complete all as specified and as directed

230

-

-

... More
M&L for complete removal of existing treatment of surfaces and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungus resistant, dirt resistant, exterior paint (of approved tint, company depot tinted) with silicon additives @1.43litre/10sqm over a priming coat of exterior primer applied @0.90litre/10sqm complete all as specified and as directed

30

-

-

... More
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.06sqm but not exceeding 0.11sqm each, 7 to 8mm thick of superior quality as in floors, etc. laid over 20mm thick screed bed in CM (1:6) (rate shall be included) set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed

110

-

-

... More
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in floors, etc. laid over 15mm thick screed bed in CM (1:6) (rate shall be included) set and jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed

159.5

-

-

... More
M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in vertical surfaces, dado, etc. jointed in neat cement slurry @3.00kg of cement per sqm and pointed in white cement mixed with colouring pigment to match shade of tiles, fixed over and including 10mm thick backing coat in CM (1:4) (rate shall be included) complete all as specified and as directed

10

-

-

... More
M&L for glazed ceramic tiles, coloured, of sie 450x300x7mm or 350x250x7mm thick of superior quality as in skirting, dado, etc. laid over 10mm thick backing coat in CM (1:4) (rate shall be included) pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed

40

-

-

... More
M&L for vitrified tiles, coloured, 10mm thick, joint free, edge cut, area of each tile exceeding 0.18sqm but not exceeding 0.36sqm, of superior quality on floors, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles, laid over and including 15mm thick screed bed in CM (1:6) (rate shall be included) complete all as specified and as directed

136

-

-

... More
M&L for vitrified tiles, coloured, 10mm thick, joint free, edge cut, area of each tile exceeding 0.18sqm but not exceeding 0.36sqm, of superior quality onskirting, dado, etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the colour of tiles, laid over and including 10mm thick screed bed in CM (1:4) (rate shall be included) complete all as specified and as directed

17

-

-

... More
M&L for glazed ceramic tiles, coloured, of size 450x350mm, 6 to 7mm thick, of superior quality as in vertical surfaces, skirting, dado, etc. laid over 10mm thick backing coat in CM (1:4) (rate shall be included) pointed in white cement mixed with colouring pigment to match shade of tiles complete all as specified and as directed

37

-

-

... More
M&L for 20mm thick granite stone slab, of any type, table rounded, rubbed and polished, in cills, cooking platforms, partitions and the like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of slab complete all as specified and as directed

2

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed

530

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour (as approved) having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed

72

-

-

... More
E/M WORKS

-

-

-

... More
Taking down copper / aluminium point wiring (light, fan, socket or power) including fixture and fittings viz. switches, ceiling roses, light fittings, pendants, regulators, sockets, etc. and disposing off complete all as specified and as directed

143

-

-

... More
M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC casing capping not less than 20mm wide and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and including pressed steel sunken boxes, readily available (having wall thickness not less than 1.22mm for boxes upto a size of 200mmx300mm and beyond that the wall thickness shall not be less than 1.63mm) conclealed type with 3mm thick bakelite cover for fixing of switches, sockets, fan regulator etc complete all as specified and as directed for the following:

-

-

-

... More
One light point controlled by one 5A one way switch

31

-

-

... More
One ceiling fan / exhaust fan point controlled by one 5A one way switch

19

-

-

... More
One switch socket outlet 3 pin 5A controlled by one switch on independent board

18

-

-

... More
One switch socket outlet 3 pin 5A controlled by one switch on same board

6

-

-

... More
M&L for point wiring with 2.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC casing not less than 20mm dia and including all accessories and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for 3 pin 15A switch socket independent outlet complete all as specified and as directed

3

-

-

... More
S&F ceiling rose surface bakelite 65x50mm, ISI marked, with three terminals complete all as specified and as directed

78

-

-

... More
S&F switch piano flush button type, single pole, ISI marked, one way 5A, 230V complete all as specified and as directed

135

-

-

... More
S&F switch socket combination outlet, 5 in 1, 6 pin, 5 & 15A flush type, ISI marked, 240V complete all as specified and as directed

7

-

-

... More
S&F switch socket outlet, 5 pin, 5A flush type, universal, ISI marked, 230V complete all as specified and as directed

51

-

-

... More
S&F PVC / polycarbonate lamp holder, insulated body, bracket holder / angle holder with back plate 240V complete all as specified and as directed

6

-

-

... More
S&F electronic fan regulator, stepped socket type (5 steps), 100W, 50Hz, 230V, ISI marked duly connected up complete all as specified and as directed

21

-

-

... More
M&L for point wiring with 1.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly complete all as specified and as directed for the following:

-

-

-

... More
One light point controlled by one 5A one way switch

25

-

-

... More
One ceiling fan / exhaust fan point controlled by one 5A one way switch

9

-

-

... More
One switch socket outlet 3 pin 5A controlled by one switch on independent board

19

-

-

... More
One switch socket outlet 3 pin 5A controlled by one switch on same board

4

-

-

... More
M&L for point wiring with 2.5sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories concealed in walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for 3 pin 15A switch socket independent outlet complete all as specified and as directed

4

-

-

... More
M&L for point wiring with 4sqmm, two single core, FRLS PVC insulated, ISI marked, unsheathed cable 1100V grade, IS-694 marked, with multi-stranded copper conductor, drawn through and including non-metallic heavy duty PVC conduit not less than 20mm dia and accessories flush on walls, ceiling etc. and including provision of 1.5sqmm copper wire, green colour as earth continuity conductor and connected to common earth dolly for AC / equipment controlled by one SP/SPN MCB independent, wiring from DB to swicth socket running independently with 3 wires for each point without tapping complete all as specified and as directed

1

-

-

... More
S&F LED bulb 9W, 5 star rated, B-22 CDL and connecting to lamp holder including taking down and disposing off old bulb / lamp complete all as specified and as directed Make: Crompton, Phillips, Wipro, Surya, Havells, Bajaj

6

-

-

... More
S&F surface mounted compact LED batten , decorative box type, polycarbonate housing, 230V, all accessories pre-wired internally, with 20W LED tube rod and connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed

36

-

-

... More
S&F building security light, LED luminaire 25W IP 66 with LED lamp, driver, etc. with all accessories pre-wired and connecting with 3 core flexible copper conductor cable drawn through PVC conduit of size 20mm and taking down and disposing off old fitting complete all as specified and as directed

10

-

-

... More
S&F 600x600mm LED type down lighter 36W with drivers connecting accessories and provision of fixing arrangements in false ceiling and connecting up including taking down and disposing off old fitting complete all as specified and as directed

4

-

-

... More
S&F heavy duty, steel body with steel blades, legs, ISI marked energy efficient, 230V, 50Hz, 1200RPM, exhaust fan, 380mm sweep with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts and making good the disturbed areas and surfaces including taking down old unserviceable fans of any capacity and depositing in MES store yard including all loading, unloading, carting, etc. complete all as specified and as directed

5

-

-

... More
S&F heavy duty, PVC body with PVC blades, legs, AC, single phase, ISI marked energy efficient, 240V exhaust fan, 250mm sweep with louvers and connecting up including provision of three core flexible copper wire of size 1.5sqmm from ceiling rose to exhaust fan including grouting the nuts and bolts including taking down old / unserviceable fan any type and disposing off complete all as specified and as directed

2

-

-

... More
S&F BLDC ceiling fan 1200mm sweep, 230V, minimum air delivery 210CFM with service value 6.00 BEE 5 star rated, with blades, down rods and accessories and connecting up including disconnecting, taking down of old unserviceable fan and depositing to MES storeyard including all loading, unloading, carting, etc. complete all as specified and as directed

21

-

-

... More
S&F sheet metal enclosures for 8 way MCB DB, 240V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down old damaged DB and disposing off complete all as specified and as directed

3

-

-

... More
S&F sheet metal enclosures for 4 way MCB DB, 415V, SPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down old damaged DB and disposing off complete all as specified and as directed

2

-

-

... More
S&F sheet metal enclosures for 4 way MCB DB, 415V, TPN, double door, IP 43 protection class conforming to relevant IS, with 200A rated insulated aluminium bus bar, neutral link, DIN rail, blanking plates, etc. duly flushed in wall and making good the disturbed surfaces including taking down old damaged DB and disposing off complete all as specified and as directed

2

-

-

... More
S&F metal clad socket outlet with single pole enclosure with 5 pin and earth plug socket including 1No. MCB SP 32A 10kA 240V and taking down and disposing off old/unserviceable socket complete all as specified and as directed

1

-

-

... More
Taking down old unserviceable submain wiring of any type, any size, from any location or position and disposing off including making good the disturbed surfaces, etc. complete all as specified and as directed

140

-

-

... More
M&L for submain wring using proper colour coding with 4 runs of single core, PVC insulated, FRLS unsheathed suitable for 1100V, multistranded, copper conducter cable of size 6sqmm and 1 run of 4sqmm multistranded, copper conductor cable 1100V green colour for earth conductor drawn through and including PVC conduit 20mm wide, heavy duty, ISI marked concealed in wall/ceiling/roof, etc. with all required accessories complete all as specified and as directed Notes: (i) 2 runs of 4sqmm main cable, 1 run of earth conductors and 1 run of PVC conduit shall be measured as one length (ii) Separate conduit shall be used for each sub-main wiring circuit irrespective of numbers of wire (iii) The minimum size of conduit shall be as stipulated, however higher sizes shall be used as per number of cables passing through. The Engineer-in-charge shall ensure for proper size of casing as per requirement at site

140

-

-

... More
S&F in repairs MCB SP, 240V, 6 to 32A, 10kA, 50Hz, C curve complete all as specified and as directed

24

-

-

... More
S&F in repairs MCB isolator SPN, 240V, 40A, 10kA, 50Hz, C curve complete all as specified and as directed

12

-

-

... More
S&F in repairs MCB isolator TPN, 240V, 63A, 10kA, 50Hz, B curve complete all as specified and as directed

1

-

-

... More
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes

8.5

-

-

... More
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed

880

-

-

... More
S&Fsteel water tubing, light grade, 50mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc. including taking down old and making the disturbed suarfaces good,complete all as specified and as directed

12

-

-

... More
S&Fsteel water tubing, light grade, 32mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc. including taking down old and making the disturbed suarfaces good,complete all as specified and as directed

7

-

-

... More
S&Fsteel water tubing, medium grade, 25mm bore, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for cable protection, etc. including taking down old and making the disturbed suarfaces good,complete all as specified and as directed

50

-

-

... More
S&F in repairs gun metal globe or gate valve, 25mm dia, with iron wheel head, screwed both ends for iron pipe and fixed including necessary cutting into existing pipe, threading, inserting new piece of GI pipe of existing size, breaking/cutting into cement concrete, masonry, etc. and making good the disturbed surfaces complete all as specified and as directed

1

-

-

... More
M&L for cutting into existing 25mm bore GI pipes in position and any location for insertion of tees, tail piece, collars, branch pipes, reducers, etc. at any required length for branch connection, etc. complete all as specified and as directed Notes: (a) Excavation and earthwork will be measured and paid separately under respective items herein (b) Both sides cut shall be measured as one unit

1

-

-

... More
Supply, laying, jointing, connecting and testing 2 core 25sqmm XLPE insulated PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, conforming to IS: 7098 (Part-I), heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed Note: Excavation and earthwork will be measured and paid separately under respective item herein

50

-

-

... More
Supply, laying, jointing, connecting and testing 4 core 25sqmm XLPE insulated PVC sheathed cable 1100V grade, screwed PVC bedded, armoured electric power cable, conforming to IS: 7098 (Part-I), heavy duty multi-stranded aluminium conductor laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed Note: Excavation and earthwork will be measured and paid separately under respective item herein

70

-

-

... More
M&L for earthing using GI earthing wire with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth lead wire 4mm dia extended to 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 15mm light grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x 600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications, taking down and disposing off old earthing complete all as specified and as directed

3

-

-

... More
Notes for serial item No.180: (i) The cost of GI earth continuity wire / strip with GI pipe 20mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item (iii) Earthing shall produce desired earth resistance values as directed by the Engineer-in-charge

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.