Irrigation Department Tender

... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Irrigation Department Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Dec 2024
Closing Date2 Jan 2025
Tender Amount₹ 24,70,030 
Notes
Download

Costs

Summary

Renovation Of Dtw Scheme At Abhoipur And Sapekhati Area Point No.5 Under Sopd-g For The Year 2024-25

Description

lockUnlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

lockUnlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

lockView all details for FREE
... More
Supply, fitting-fixing of Heavy duty CIDF Reflex valve, swing check type with bypass arrangement, horizontal operating. The holes of the flange to be as per BSS No. 10, Part-I, Table-D and the material, construction and all components should strictly conform to IS : 5312 (Part-I)-2004 and having arked with manufacturers name and trade mark in the delivery pipe layout as directed / as per drawing along with HD GI flange, pipe jointing set and painting in complete as directed. Rate as per Annexure-IV & DPC,Mech 2019-20. (i) 100mm dia

1

11821

-

... More
Supply, fitting-fixing of delivery pipes of 80/100 mm dia GI / fabricated GI pipes ( HD of repute brand with ISI marked) with flange at both end / wherever required with pipe jointing sets, including painting in complete as per drawing / specification including temporary pipe support as required and as directed.

8

5160

-

... More
Fitting-fixing of MS / GI bend of 80/100 mm dia x 450 / 900 / 1200 with GI / fabricated GI pipes with flange at both end and pipe jointing sets, including painting as per drawing / specification as directed.

3

3488

-

... More
Supply of G.I Equal Tee of 80/ 100 mm Dia. Complete as directed.

1

3000

-

... More
Fitting, fixing of G.I Equal Tee of 80/ 100 mm Dia. Complete as directed.

1

3488

-

... More
Supply, fitting-fixing of surge tank of size 900mm dia x 1250mm long made of 4mm MS plate with raiser assembly of size 75mm dia x 6.0m long and S-band of size 100mm x 1600mm long made of 4mm MS plate including painting the above with one coat of synthetic enamel primer followed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified foundation by nuts & bolts of suitable size as per drawing & specification as directed.

1

141855

-

... More
Supplying and erection of MS Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with Clamps, Nuts & Bolts duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed a)75mmX40mmX6mmX2200mm

7

2543

-

... More
Supplying and erection of GI Angle Cross Arm on Poles along with GI Clamps, GI Nuts & Bolts including drilling of necessary holes as directed Size 50mm × 50mm × 6mm, 2200 mm long

3

2074

-

... More
Supplying and erection of GI T Cross Arm for 11 kV Line on PSC Poles along with Clamps, Nuts & Bolts including drilling of necessary holes as directed

10

1773

-

... More
Supplying and erection of Cross Bracing Sets for 11 kV Line on DP (Double Pole) Structure comprising of 2(two) Nos. of MS Angle of size 50 mm × 50 mm × 6 mm × 2200 mm fitted horizontally and other 2 Nos. 3200 mm long fitted diagonally along with MS Pole Clamps, Nuts Bolts and washer duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed

5

8030

-

... More
Supplying and Erection of 11 kV HT Stay Set comprising of 19mm dia × 1.8 m Stay Rod, Anchor Plate, Bow, Thimble etc. including supply and erection of 7/10 SWG G I Stay Wire and 11kV Guy Insulator complete including digging of Earth Pit of size (0.9m × 0.9m) to a depth of 1.4 Metre, placing the Stay Rod with Plate, fixing thimble, bow etc. with Boulder packing (size 150mm to 200mm) and hard ramming to fill up half the pit and filling with hard soil packing upto the Ground Level as directed (A) In Hard Soil with Boulder

5

3136

-

... More
Supplying and Erection of 11 kV Polymeric Disc Insulator 45 kN on existing Hardware Fitting on Cross Arm as directed

18

672

-

... More
Supplying, Laying and Erection of Conductors of following size and specification for Overhead Line, binding to Insulators and Tensioning with Uniform Standard Sag including Jumpering connection as directed. 6.7.2 ACSR Conductors (D) ACSR Raccoon Conductor

1560

160

-

... More
Supplying, Fitting and Erection of 3-φ 11 kV Gang Operated (G.O.) Air Break Switch having nominal System Voltage of 12 kV, rated Voltage 11 kV, rated Frequency 60 Hz, and peak current in closed position 46 kA, conforming to IS 2544, IS 5340(Part-III) and IS 9921(Part I to V) suitable to opearate in all climatic condition of following current ratings on existing Channels complete with Operating Pipe and Handle including making of necessary Electrical Connections as directed. 400 Amps

1

20043

-

... More
Supplying and Erection of 3-φ 11 kV Drop Out (D.O.) Fuse Unit rated voltage 11 kV R.M.S. To 12 kV R.M.S., highest System Voltage 12 kV, each pole consisting of Polymeric insulator, all current carrying parts made of a highly conductive copper alloy and contact portion are silver plated for corrosion resistance and efficient current flow and the fuse tube made of fibre glass coated with ultraviolet inhibitr on the outer surface and having Arc Quenching bone fibre liner inside conforming to IS 9385/1983 of following current ratings on existing Channels complete with Barrel Fuse and making of necessary Electrical Connections as directed. (150 amp)

3

8867

-

... More
Supplying and Erection of Metal Oxide gapless Lightning Arrestor of following specification on MS Channel with Clamps, Nuts & Bolts including drilling of holes and making of necessary connection with Line Conductors as directed. 9 kV, 10 kA with Polymer body

3

6934

-

... More
Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed

5

5058

-

... More
Supply & Erection of G.I. Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed. 6 SWG G.I. Wire

60

48

-

... More
Supply including Erection of 5 Star ON-AN (Oil Natural, air Natural) Cooled Al/ CU-wound Distribution Transformer conforming to IS specifications 2026 (with latest amendments) with all standard accessories erected on double pole structure/ transformer pad including transportation and handling, loading and unloading etc, securing it on existing Channel firmly with necessary clamps, nuts & bolts . as required, and making necessary connections on HV and LV sides as directed (Cost of DP structure /Pad extra ) Capacity : Capacity : 63 kVA, 11 kV/0.433 kV (5 Star Dyn) - Al wound 8.1.2 Capacity : 63 kVA, 11 kV/0.433 kV (5 Star Dyn) - Al wound (A) Cost including Supply of Transformer

1

297570

-

... More
Supply & Erection of Anti Climbing Barbed Wire on Poles at a height of about 3 Metres and covering a length of 1.5 Metre as directed

18

318

-

... More
Supply including Laying of PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor of size 35 Sq mm × 3 core in single line, Conforming IS 7098(Part I) 1988, direct in ground including digging of tren ch of 0.3 Mtr wide × 0.75 Metre deep including Sand Cushioning (7.5cm + 7.5cm) and refilling alongwith fitting, fixing of Brass Compression Gland and Aluminium Cable Lug etc. as directed

15

725

-

... More
Danger plate suitable for 11KV line conforming to IS:2552/1963 of size 200mmX200mm

8

120

-

... More
Providing Security fencing around the S/S with GI chain link net, woven with 10 SWG wire with mesh 7.5cm × 7.5cm to be erected on GI angle 40 mm × 40mm × 5mm, with necessary C C grouting, with a fencing height of 1.8 mtr, having a hinged door, fabricated with flat GI strip boundary and cross bracing, complete including supply of all materials, excavation refilling etc as reqd and as directed.

14.4

1406

-

... More
Testing and commissioning of the Substation alongwith obtaining necessary approval for charging from competent authority including payment of Inspection Fee, Arranging for Test Report etc. as required and as directed for following kVA Capacity : 25 kVA, 11 kV/0.433 kV

1

15750

-

... More
Liaisoning with APDCL, Forest Department, Electrical Inspectorate etc. right from start till Commissioning of the HT Line/Substation, Preparation of all necessary documents like Agreement and Affidavit required for new Power Connection, obtaining No Objection Certificate from Forest Department where necessary complete all arrangement for charging the Installation as required and as directed.

1

11000

-

... More
Supplying including fitting, fixing & connection of three Pole(TP) 415 V, AC MCCB of following current ratings as main incomer in already fabricated LT Control Panel Board Housing along with Lugs, Connecting Cable and all other necessary materials for connections as directed 400 Amp, Breaking Capacity 35/36 kA

1

48350

-

... More
Erection & Commissioning LT Whole Current Electronic Energy Meter including making necessary payment to APDCL for Meter Cabinet, Meter Security etc as reqd and as directed.

1

33900

-

... More
Load Security to be paid to APDCL (Approx.)

15

1800

-

... More
Supplying, installation, testing & commissioning of Panel Board for operation of 1x20 HP Electric Motor Driven Submersible Pumpset

1

81140

-

... More
Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed

1

5058

-

... More
Supply & Erection of G.I. Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed. 6 SWG G.I. Wire

8.21

48

-

... More
Black/Red Electrical registance rubber sheet one side chequrred & other side with cloth finished tasted upto 15KVAR as per ISS of ISI approve 1.81 mtr (L) X 0.9 mtr (B) X 10 mm (T) (persident or eqivelent make)

2

459

-

... More
Electricaly Tested Rubber Hand Gloves as per IS Specification No.47701968/1991 up 11 kv

1

877

-

... More
i) Earth work in excavation of foundation trenches including filling up side of trenches and removed of spoils after completion of foundation, dressing ramming, shoring etc. complete including bailing out water where necessary in ordinary soil.

27

378

-

... More
Removal of old PVC pipes and relaying, fitting, fixing pipe clearing debreis, testing leakage including, fitting with solvent cement etc. complete as directed.

60

575

-

... More
Supplying, fitting and fixing PVC pipes (IS I2818, 6Kg/Cft) joining pipe with relevant cement leveling, testing, leakage etc. complete as directed. (Cost of E/W foundation trenches will be paid separately) (i) For 110mm dia

30

734

-

... More
Supplying, fitting and fixing PVC pipes (IS I2818, 6Kg/Cft) joining pipe with relevant cement leveling, testing, leakage etc. complete as directed. (Cost of E/W foundation trenches will be paid separately) (i) For 160mm dia

30

1550

-

... More
Supplying, fitting and fixing PVC reducer joining with pipe with solvent cement testing leakage etc. as directed. (i) Size: 160mm x 110mm

4

655

-

... More
Supplying, fitting and fixing PVC bend pipe size joining with pipes with solvent cement, testing leakage etc. complete as directed. (i) For 110mm/90°

2

836

-

... More
Supplying, fitting and fixing 110mm dia NTP valve at the top of PVC rising pipe of spout chamber as per specification including local carriage complete as directed.

2

3704

-

... More
Supplying, fitting 110mm dia PVC rising pipe from the toe of main line including local carriage testing leakages etc, complete as directed.

4

1183

-

... More
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.

19.2

802

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate

17.8

614

-

... More
Providing and fixing plain multipurpose cement board (Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). 12.26.1 6 mm thick Cement fiber board as per IS: 14862

19.2

921

-

... More
Renewing wooden beams in roofs including making good the holes in walls and painting with oil type wood preservative of approved brand and manufacture complete, including removal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 14.16.1 Not exceeding 4.00 metres in length. 14.16.1.2 Hollock wood beams

0.49

70271

-

... More
Providing corrugated galvanized Iron sheet roofing made up of High Strength Steel of minimum Tensile Strength of 450 MPa with 120 gsm (gram/Sqm) Zinc coating on both side as per class 8 of BIS including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I.limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (12.1.3) 0.63 mm thick Total Coated Thickness (TCT)

33.66

1087

-

... More
Providing ridges or hips of width 60cm overall width plain GS sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia GI limpet and bitumen washers complete. 12.4.2: 0.63 mm thick with zinc coating not less than 275 gm/Sqm. (ii) 230 mm lapping

7.5

980

-

... More
Providing and fixing plain jaffri door and window shutters including bright or/and black enamelled M.S. butt hinges with necessary screws 35x10 mm laths placed 35 mm apart (frames to be paid separately), including fixing 50x12 mm beading complete with : 14.27.1 Second class teak wood

4.8

4602

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia. & length (hold fast lugs or dash fasteners shall be paid for separately) 9.1.3: Kiln seasoned and chemically treated hollock wood

0.17

83378

-

... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. 14.1.1 With cement mortar 1:4 (1 cement : 4 fine sand)

28.09

547

-

... More
Distempering with 1st quality acrylic distempetr (ready mixed) having VOC (Volatile Organic Compund) content less than gram/litre of approved brand and manufacturer including applying additional costs wherever required to achieve even shade and colour 13.81.1 Old work (one or more coats)

104.82

62

-

... More
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4)

3.35

12855

-

... More
12 mm cement plastering including clearing surface and curing complete as directed. In prop. 1: 4

45.9

281

-

... More
Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line including local carriage, testing leakage etc. complete as directed.

5

1183

-

... More
Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc. complete as directed. 110 mm / 90

5

836

-

... More
Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately). 110mm dia

5

734

-

... More
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.

0.98

693

-

... More
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.

0.98

802

-

... More
C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).

0.07

9346

-

... More
R.C.C work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 (M15) with hard river shingles of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).

0.47

9794

-

... More
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).

5.39

543

-

... More
12 mm cement plastering including clearing surface and curing complete as directed. In proportion 1:4

1.2

281

-

... More
Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.

0.42

12997

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing inposition and applying a priming coat of approved steel primer using structural steel etc as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works

82.44

172

-

... More
Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of hollock wood in scantling of section 50X25 mm, fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge

100.5

689

-



Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.