Irrigation Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Irrigation Department Tender

Works
Civil And Construction
Eprocure
Opening Date13 Jun 2024
Closing Date26 Jun 2024
Tender Amount₹ 37,07,400 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying sal wooden hammer of of size 15 cm x 10 cm with 45 cm long & 5 cm wooden handle etc. complete as directed.

2

-

958.23

... More
Construction of Approach Road

-

-

-

... More
Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layer not exceeding 15cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat at embankment and borrow pit area, breaking clods not more than 10mm cube, ramming, watering, dressing and roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M complete as directed. A) Ordinary soil

7.5

-

498.31

... More
Collection and supply of sand and gravel (40% sand and 60% gravel) of size 13mm to 38mm from approved quarry including loading, unloading and stacking in measurable stacks at work site up to a height of 1.00m including payment of forest royality etc.

1.14

-

2555.16

... More
Labour charges for spreading hard river shingles / sand gravels to required thickness over approach subway etc. including ramming, dressing the seat before laying the materials lead upto 30.00 M and lift 1.50 M. Complete as directed.

1.14

-

457.23

... More
Boring and Installation of Tube Well, Supply & Installation of Solar Pumping System

-

-

-

... More
Movement of drilling Rig , Tools & Plants, Accessories including drill pipes, casing pipes etc. to drilling site and back.

50

-

1092.78

... More
Boring of DTW of bore hole up to 450mm dia and up to a depth of 70 M or up to required depth by RC/DR Drilling Rig including supply and transportation of all required tools & Plants, materials & labour to site to perform the job in complete as directed in alluvium areas ( means areas where the strata comprises of loose, unconsiolidated materials like clays, silts, sands gravels, pebbles, cobbles and boulders) as per IS:2800 (part-1) of 1991. ( soil sample must be collected & keep properly at every 3.00 M interval of depth in boring. The job also include movement of rig by making temporary approach road etc. to the field up to distance of 1000M)

70

-

5665.83

... More
Supply, lowering & installation in tube well 200mm PVC housing pipe / blind pipe of wall thickness of 10.0 mm to 11.2 mm for casing assembly including supply of well cap, sockets, reducer, MS housing clamps etc. as required as per IS : 12818-1997 of length 3.00 M of repute brand like Oriplast / Jindal / Prince etc. and as directed. ( Litholog Assembly diagram must be approved by Engineer-in-Charge of the work prior to installation)

52

-

5069.42

... More
Supply, Lowering & Installation in tube‐well 200 mm PVC Ribbed Screen Filter pipe of wall thickness of 10 mm to 11.2 mm for casing assembly including supply of sockets , reducer, etc. as required as per IS : 12818‐1997 of length 3.00 M/ 2.00 M of repute brand like Oriplast/ Jindal/ Prince, etc. and as directed. (Litholog Assembly diagram must be approved by Engineer -in‐Charge of the work prior to installation) 

18

-

7103

... More
Shrouding the DTW assembly by river pea gravel of size 4 mm to 8 mm free from sand / dust and any other foreign materials after screening / stacking at site including supply, transportation, labour etc. complete as directed.

10

-

7962.07

... More
Developing the tube well assembly by Air-Compressor of capacity 8-12 kg/cm2 and CFM=450 M3/min so as to get sand free discharge of water with supply of all required materials at site complete as directed including furnishing of litho-log / draw down data etc. as per IS : 11185 of 1999. ( For new DTW minimum 72 hours development is compulsory. Additional pea gravel required if any, during development would be extra) The following data should be reflected in the report of development: 1. Static water level 2. Drawdown at various discharge 3. Available average discharge

72

-

3721.36

... More
(a) Solar Submersible Standalone Pump set with 7.5 HP AC Induction motor and Solar Power Controller Unit ( Conform IEC 6168311:1999) with overload, over-under voltage, short circuit protection, suitable for 200 mm bore well and discharge capacity approx 1400 LPM at 10 M head (Dynamic Head Range 10-20 Mtr and Shut off head 30 M) working at 8000 Wattp of solar power along with Cables, Inverter external box, surge suppressor, DC MCB & all necessary accessories like, 2(two) pairs of Assembly support clamps, 10(ten) nos. of Cable clamp / clip, 1 (one) no. of Delivery bend, 20(twenty) mtr. column pipe, 1(one) no. of Short pipe of 1.5 Mtr. length of required diameter, 40(forty) mtr.(approx.) Flat flexible cable (motor to controller) as per latest MNRE norms and as per IS. (b) Supply, fitting-fixing and testing & commissioning of Solar PV modules conforming to IEC 61215 specification or equivalent National or International standards consisting of solar panels framed in anodized aluminium frame of 8000 Wp (approx.) considering 7.15 kWh/ M2/ Day of solar insolation under standard test condition on horizontal surface with tolerance (+/-) 15% and hot dipped galvanized(minm 80 micron thickness) mounting mild steel structure of rectangular hollow sections, angles, heavy duty pipes of dia 150 mm (all materials duly IS marked ) for providing sufficient strength with dual axis manual tracking arrangement which can withstand load of modules and high wind velocities upto 150 Km/hr including RCC foundation designed against all possible loads (Dead, Live and imposed load), Controller conform to IEC 61683–1999 & IEC 60068-1-2, IEC 60068 – 2- (2, 14, 30, 78) ( The series and parallel combination of Solar Modules to be done in such a way that Jalverter/ Controller input voltage requirement is met i.e. System Vmp 587 V & System Voc 800 V) and necessary connection cables, pipes to the water trough and other accessories, etc. complete in all respect as directed (Controller to be installed with suitable arrangement on the body of the pole of mounting structure with rain proof provision. SPV panel should be of reputed make like TATA/Bikram/ Waaree etc. and carry at least 20 years warrenty & comprehensive maintenance for 1 year and should installed preferably above HFL) (c) Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. Below the ground level as below: (a) By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. (d) Lightning protection (Arrestor)(pole mounted)(: Lightning protection with 3" X 1.5" G.I pipe of 4 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc including supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the /Roof with GI Saddles 1100 mm apart. NB :- 1. Solar Pump set should be of reputed make and carry 5 years warranty/ guarantee 2. Flow Range : 90 L per Wp of PV array from TDH of 10 M 3. Controller DC Input Voltage: (i) System Vmp 587 V & (ii) System Voc 800 V 4. Controller Conforming to : IEC 61683–1999 & IEC 60068-1-2,IEC 60068–2-(2,14,30,78) (Rate As per MNRE Circular No. 32/24/2020-SPV Division, dt-26/10/2021 including cost of remote monitoring & USPC) This benchmark cost are for the systems installed as per MNRE specifications inclusive of the total cost of system and its installation, commissioning, transportation, insurance, warranty/guarantee, monitoring & maintenance for five years. Cost Solar Standalone Pumping System = Rs 4,08,631.00 Add GST @ 18 % = Rs 73,553.58 Cost Solar Pumping System = Rs 4,82,184.58

1

-

487006.42

... More
Supply, fitting-fixing of Heavy duty CIDF sluice valve inside screw, non raising, vertical spindle type with hand wheel operation need of water purpose. The rotation of closing should be counter clock wise. The holes of the flange should be drilled as per BSS No. 10 , Part-I, Table-D. All materials construction and components should strickly conform to IS : 14846-2000 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed / as per drawing along with HD GI flange, pipe joining materials and painting in complete as directed. (i) 100mm dia

2

-

11439.07

... More
Supply, fitting-fixing of Heavy duty CIDF Reflex valve, swing check type with bypass arrangement, horizontal operating. The holes of the flange to be as per BSS No. 10, Part-I, Table-D and the material, construction and all components should strictly conform to IS : 5312 (Part-I)-2004 and having arked with manufacturers name and trade mark in the delivery pipe layout as directed / as per drawing along with HD GI flange, pipe jointing set and painting in complete as directed. (i) 100mm dia

1

-

11940.03

... More
Supply, fitting-fixing of delivery pipes of 80/100 mm dia GI / fabricated GI pipes ( HD of repute brand with ISI marked) with flange at both end / wherever required with pipe jointing sets, including painting in complete as per drawing / specification including temporary pipe support as required and as directed.

8

-

5211.6

... More
Ftting-fixing of MS / GI bend of 80/100mm dia x 450 / 900 / 1200 with GI / fabricated GI pipes with flange at both end and pipe jointing sets, including painting as per drawing / specification as directed.

3

-

3523.71

... More
Supply of G.I. equal tee of 80/100 mm dia complete as directed.

1

-

3030

... More
Fitting, fixing of G.I. equal tee of 80/100 mm dia completed as directed.

1

-

3523.7

... More
Supply, fitting-fixing of surge tank of size 900m dia x 1250mm long made of 4mm MS plate with raiser assembly of size 75mm dia x 6.0m long and S-band of size 100mm x 1600mm long made of 4mm MS plate including painting the above with one coat of synthetic enamel primer fllowed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified foundation by nuts & bolts of suitable size as per drawing & specification as directed.

1

-

143273.86

... More
Construction of Rest Room

-

-

-

... More
Earth work in excavation for foundation trenches including filling up sides of trenches and removal of spoils after completion of foundation , dressing, ramming, shoring etc. complete including bailing out water where necessary in ordinary soil.

1.71

-

386.25

... More
CC Work in proportion 1:3:6 in foundation /abutment/ pier/wing walls etc. with hard broken stone aggregate of size 13 to 38 mm including curing with necessary shuttering , Scafolding etc. where necessary, complete as directed. (shuttering where necessary shall be measured and paid separately).

0.43

-

9536.11

... More
Brick work in cement mortar with 1st class brick as directde in foundation, retaining walls, plinth & steps including recking out joints & curing (a) In proportion 1:4

2.78

-

13115.9

... More
Providing & laying 4 cm thick damp proof Course (D.P.C.) with cement motor in prop 1:2:4 with approved damp proofing compound.

2.15

-

402.31

... More
River sand filing in plinth, canal bed, canal slope, bases of structures etc. in layer not more than 15 cm thick including necessary carriage, watering and ramming etc complete as directed and specified .

3.1

-

2066.17

... More
Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.

0.7

-

13261.44

... More
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered). (C) Shuttering (Column)

6.23

-

554.36

... More
CC work in proportion 1:2:4 in foundation/abutment/piers/ wing walls etc. with hard broken stones aggregate of size 13mm to 38mm including curing etc, complete as directed with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately).

0.57

-

10338.72

... More
125 mm thick 1st class brick nogged wall in cement mortar in prop 1:4 including racking out joints curing etc. complete as directed.

2.33

-

13115.9

... More
12 mm cement plastering including clearing surface and curing complete as directed. b) In cement mortar 1:4

46.06

-

287.6

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

49

-

84.84

... More
Providing galvanized C.I. sheet roofing including supplying fitting and fixing necessary galved, screws / iron "J" hooks bolts and nuts and washers etc. complete as directed including cost of roof truss (measurement on net roof area) 0.63 mm thickness (24 B.W.G).

12.58

-

1060.99

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top/centre hung , with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted,including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

35.42

-

190.56

... More
Distempering two coats including painting two coats to batten with approved paint complete as directed.

29.1

-

100.62

... More
Soling in foundation in floor at all level septic tank etc. including filling interstices ramming etc. complete as directed and as specified thickness . (i) 9 cm brick on flat including sand packing.

5.63

-

818.46

... More
62 mm thick CC flooring with concrete hardener topping under layer 50mm thk. cement concrete in prop 1:2:4 and top layer 12mm thk. Cement hardener consisting of mix 1:2 by volumn hardening compound mixed @ 2 litre per 50 kg of cement or as per manufecturers specification. This includes cost of cement slurry, but excluding cost of nosing of steps as complete..

5.69

-

1007.45

... More
Underground PVC Pipe Distribution System

-

-

-

... More
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.

414

-

700.71

... More
Supplying, fitting, fixing PVC Pipes (IS 12818, 6 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately). A) 160mm dia

400

-

1565.52

... More
Supplying, fitting, fixing PVC Pipes (IS 12818, 6 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately). B) 110mm dia

336

-

741.74

... More
Supplying, fitting, fixing PVC unequal tee joining with pipes with solvent cement, testing leakages etc. complete as directed. Size 160 mm x 160 mm x 110 m

6

-

1374.6

... More
Supplying, fitting, fixing PVC reducer joining with pipes with solvent cement, testing leakages etc, complete as directed. Size 160 mm x 110 mm

1

-

662.13

... More
Supplying, fitting, fixing joining of PVC end cap fitting with solvent cement as per specification including local carriages, testing leakages, etc. complete as directed.

7

-

363.45

... More
Sipplying, fitting and fixing of 110 mm dia NTP valve at the top of PVC rising pipe of spout chamber as per specification including local carraige complete as directed.

7

-

3741.83

... More
Construction of Spout chamber ( 7 Nos)

-

-

-

... More
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. In ordinary soil

5.49

-

700.71

... More
C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).

2.06

-

9632.11

... More
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4)

3.43

-

13512.02

... More
12 mm cement plastering including clearing surface and curing complete as directed. In prop. 1: 4

27.12

-

284.71

... More
Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line including local carriage, testing leakage etc. complete as directed.

7

-

1195.76

... More
Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc. complete as directed. 110 mm / 900

7

-

844.89

... More
Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).

8.4

-

741.74

... More
Construction of Boundary Wall

-

-

-

... More
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.

6.74

-

707.83

... More
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.

6.74

-

818.46

... More
C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).

0.5

-

9536.11

... More
R.C.C work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 (M15) with hard river shingles of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).

2.09

-

9992.99

... More
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered). (C) Shuttering (Column)

24.71

-

554.36

... More
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered). (B) Shuttering (Beams) with out props

13.22

-

225.43

... More
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (a) In proportion 1:4

1.03

-

13115.9

... More
12 mm cement plastering including clearing surface and curing complete as directed. In proportion 1:4

30

-

287.6

... More
Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.

4.24

-

13261.44

... More
Chain link fabric fencing mesh of size 50X50 mm made of GI wire of dia 4mm

29.7

-

325.46

... More
In gratings, frames, guard bar, ladder, railing, brackets, gates and similar works

82.44

-

154.38

... More
Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layer not exceeding 15cm thick including clearing light jungle, removing trees upto 15cm dia & uprooting roots and stumps from the seat at embankment and burrow pit area, breaking clodes not more than 10mm cube, ramming, watering , dressing and roughening the seat of embankment, profiling etc.

59.4

-

461.17

... More
Construction of Supporting Pillar

-

-

-

... More
Earth work in excavation of foundation trenches including filling up sides of trenches and removal of spoils after completion of foundation, dressing, ramming, shoring etc complete including bailing out water weather necessary in ordinary soil.

14

-

247.05

... More
Soiling in foundation floor at all levels septik tank etc. including filling interstices ramming etc. complete as directed and as specified thickness (i) 9 cm brick on flat including sand packing

14

-

534.27

... More
C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).

1.4

-

7049.66

... More
Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work, including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed.

4.2

-

8632.03

... More
Centering and shuttering including propping etc. where necessary and removal of forms after completion of C.C. and R.C.C. works as directed complete (measurement to be taken on the face area timbered).

14.98

-

392.85

... More
CC in RCC work as specified and directed and including curing etc. (reinforcement and shuttering to be measured and paid separately) the line aggregate should be approved clear river sand of coarse variety and shall be 5mm down work and not to be pass through a 25 IS sieve (width of appartus is 0.25mm) the coarse aggregate shall be cubicle, hard, perfectly clean and free from clay and adherent impurities and chemically inner broken stone chips of approved quality and shall pass through 19mm mesh without squeezing and be retained on15mm mesh. The fine and coarse aggregate shall be well graded and evenly distributed between the limit and mixes shall be made with adequate quantity of clear water required to have the strength as specified in I S Code. M15 grade

3.92

-

8856.62

... More
Earthwork in back filling of structures obtained from outside borrow pit filling in 15cm layers, ramming, dressing, watering, i/c paying compansation of land if any (with lead up to 30M and lift 1.5 M)

15.82

-

375.81

... More
20 mm bolt

84

-

168.33

... More
Construction of Sign Board

-

-

-

... More
Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed.

1

-

12875.68



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.