Irrigation Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 2,12,856Document Cost
₹ 2,300Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ID_39149_19Bid Award Id
ViewTender No
01_RIDF_XXX_2024_25 Date_21_09_2024Tender Authority
Irrigation Department ViewPurchaser Address
-Website
http://https://irrigation.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Item No. 3 :Supply, lowering & installation in tube well 200mm PVC housing pipe / blind pipe of wall thickness of 10.0 mm to 11.2 mm for casing assembly including supply of well cap, sockets, reducer, MS housing clamps etc. as required as per IS : 12818-1992 of length 3.00 M/2.00 M of repute brand like Supreme / Oriplast / Jindal / Prince etc. and as directed.
( Litholog Assembly diagram must be approved by Engineer-in-Charge of the work prior to installation)
156
-
5069.42
Item No. 4 : Supply, lowering & installation in tube well 200mm PVC Ribbed Screen Filter pipe of wall thickness of 10.0 mm to 11.2 mm for casing assembly including supply of sockets, reducer etc. as required as per IS : 12818-1992 of length 3.00 M/2.00 M of repute brand like Supreme / Oriplast / Jindal / Prince etc. and as directed.
( Litholog Assembly diagram must be approved by Engineer-in-Charge of the work prior to installation)
54
-
7103.01
Item No. 5 : Shrouding the DTW assembly by river pea gravel of size 4 mm to 8 mm free from sand / dust and any other foreign materials after screening / stacking at site including supply, transportation, labour etc. complete as directed.
30
-
7962.08
Item No. 6 : Developing the tube well assembly by Air-Compressor of capacity 8-12 kg/cm2 and CFM=450 M3/min so as to get sand free discharge of water with supply of all required materials at site complete as directed including furnishing of litho-log / draw down data etc. as per IS : 11185 of 1999. ( For new DTW minimum 72 hours development is compulsory. Additional pea gravel required if any, during development would be extra )
216
-
3721.37
Item No.7: Supply, fitting-fixing of Heavy duty CIDF sluice valve inside screw, non raising, vertical spindle type with hand wheel operation need of water purpose. The rotation of closing should be counter clock wise. The holes of the flange should be drilled as per BSS No. 10 , Part-I, Table-D. All materials construction and components should strickly conform to IS : 14846-2000 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed / as per drawing along with HD GI flange, pipe joining materials and painting in complete as directed.
(i) 100mm dia
6
-
11439.08
Item No. 8 : Supply, fitting-fixing of Heavy duty CIDF Reflex valve, swing check type with bypass arrangement, horizontal operating. The holes of the flange to be as per BSS No. 10, Part-I, Table-D and the material, construction and all components should strictly conform to IS : 5312 (Part-I)-2004 and having arked with manufacturers name and trade mark in the delivery pipe layout as directed / as per drawing along with HD GI flange, pipe jointing set and painting in complete as directed. Rate as per Annexure-IV & DPC,Mech 2019-20.
(i) 100mm dia
3
-
11940.04
Item No. 9 : Supply, fitting-fixing of delivery pipes of 80/100 mm dia GI / fabricated GI pipes ( HD of repute brand with ISI marked) with flange at both end / wherever required with pipe jointing sets, including painting in complete as per drawing / specification including temporary pipe support as required and as directed.
24
-
5211.6
Item No. 10 : Fitting-fixing of MS / GI bend of 80/100 mm dia x 450 / 900 / 1200 with GI / fabricated GI pipes with flange at both end and pipe jointing sets, including painting as per drawing / specification as directed.
9
-
3523.71
Item No. 11 : Supply of G.I Equal Tee of 80/ 100 mm Dia. Complete as directed.
3
-
3030
Item No. 12 :Fitting, fixing of G.I Equal Tee of 80/ 100 mm Dia. Complete as directed.
3
-
3523.71
Item No. 13: Supply, fitting-fixing of surge tank of size 900mm dia x 1250mm long made of 4mm MS plate with raiser assembly of size 75mm dia x 6.0m long and S-band of size 100mm x 1600mm long made of 4mm MS plate including painting the above with one coat of synthetic enamel primer followed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified foundation by nuts & bolts of suitable size as per drawing & specification as directed.
(Rate As per Market Price)
3
-
143273.86
Installation and commissioning of Solar PV Modules including Mounting Structure
-
-
-
Supply & Installation of Solar Pumping System: (a) Solar Submersible S tandalone Pump set with 7.5 HP AC Induction motor and Solar Power Controller Unit ( Conform IEC 6168311:1999) with overload, over-under voltage, short circuit protection, suitable for 200 mm bore well and discharge capacity approx. 1400 LPM at 10 M head (Dynamic Head Range 10-20 Mtr and Shut off head 30 M) working at 8000 Wp of solar power along with Cables, Inverter external box, surge suppressor, DC MCB & all necessary accessories like, 2(two) pairs of G.I. Assembly support clamps, 10(ten) nos. of Cable clamp / clip, 1 (one) no. of Delivery bend, 1 (one) no. enlarger/ reducer as required, 20(twenty) mtr. Column pipe of uPVC/ HDPE of working pressure of minimum 8kgf, 1(one) no. of Short pipe of 1.5 Mtr. length of required diameter, 40(forty) mtr.(approx.) Flat flexible cable (motor to controller) as per latest MNRE norms and as per IS. (b) Supply, fitting-fixing and testing & commissioning of Solar PV modules conforming to IEC 61215 specification or equivalent National or International standards consisting of solar panels framed in anodized aluminium frame of 8000 Wp (approx.) considering 7.15 kWh/ M2/ Day of solar insolation under standard test condition on horizontal surface with tolerance (+/-) 15% and hot dipped galvanized (minm 80 micron thickness) mounting mild steel structure of rectangular hollow sections, angles, heavy duty pipes of dia. 150 mm (all materials duly IS marked ) for providing sufficient strength with dual axis manual tracking arrangement which can withstand load of modules and high wind velocities upto 150 Km/hr including RCC foundation designed against all possible loads (Dead, Live and imposed load), Controller conform to IEC 61683–1999 & IEC 60068-1-2, IEC 60068 - 2- (2, 14, 30, 78) ( The series and parallel combination of Solar Modules to be done in such a way that Jalverter/ Controller input voltage requirement is met i.e. System Vmp 587 V & System Voc 800 V) and necessary connection cables, pipes to the water trough and other accessories, etc. complete in all respect as directed. (Controller to be installed with suitable arrangement on the body of the pole of mounting structure with rain proof provision. SPV panel should be of reputed make and carry at least 20 years warranty& comprehensive maintenance for 1 year and should installed preferably above HFL) (c) Earthing with 50 mm dia. GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia. x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia. GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. Below the ground level as below: (a) By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipment incl. drilling holes, with bolts, nuts, washers etc. (d) Lightning protection (Arrestor)(pole mounted)(: Lightning protection with 3" X 1.5" G.I pipe of 4 mts. height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia. 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia. 6 mm thick GI base plate at bottom incl. necessary holes etc. including supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the/Roof with GI Saddles 1100 mm apart. NB :- 1. Solar Pump set should be of reputed make and carry 5 years warranty/ guarantee. 2. Flow Range : 90 L per Wp of PV array from TDH of 10 M, 3. Controller DC Input Voltage: (i) System Vmp 587 V & (ii) System Voc 800 V, 4. Controller Conforming to : IEC 61683–1999 & IEC 60068-1-2,IEC 60068–2-(2,14,30,78), 5. The system should carry anti-theft mechanism
(Rate As per MNRE Circular No. 32/24/2020-SPV Division, dt-26/10/2021 including cost of remote monitoring & USPC)
This benchmark cost are for the systems installed as per MNRE specifications inclusive of the total cost of system and its installation, commissioning, transportation, insurance, warranty/guarantee, monitoring & maintenance for five years.
Cost of Solar Standalone Pumping System = Rs 4,08,631.00
Add GST @ 18 % = Rs73,553.58
Cost Solar Pumping System = Rs 4,82,184.58
3
-
487006.43
Construction of Control Room
-
-
-
Item No. 1 : Earth work in excavation for foundation trenches including filling up sides of trenches and removal of spoils after completion of foundation , dressing, ramming, shoring etc. complete including bailing out water where necessary in ordinary soil.
5.13
-
386.25
Item No. 2 : CC Work in proportion 1:3:6 in foundation /abutment/ pier/wing walls etc. with hard broken stone aggregate of size 13 to 38 mm including curing with necessary shuttering , Scafolding etc. where necessary, complete as directed. (shuttering where necessary shall be measured and paid separately).
1.29
-
9536.11
Item No. 3: 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc, including racking out joints and curing etc, complete as directed.(i) in proportion 1:4
8.34
-
13115.9
Item No. 4 :Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
6.45
-
402.31
Item No. 5 : River sand filling in plinth, canal bed, canal slopes, bases of structure, etc in layers not more than 150 mm thick including necessary carriage, watering etc,complete as directed as specified.
9.3
-
2066.17
Item No. 6 : Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.
2.13
-
13261.44
Item No. 7:Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered). (C) Shuttering (Column)
18.69
-
554.36
Item No. 8: CC work in proportion 1:2:4 in foundation / abutment / piers / wing walls etc.with hard broken stone aggregate of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately)
(a) M 15 grade
1.71
-
10338.72
Item No. 9 : 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4)
6.99
-
13115.9
Item No. 10: 12 mm cement plastering including clearing surface and curing, complete as directed.
b) In cement mortar 1:4
138.18
-
287.6
Item No. 11 : Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
147
-
84.84
Item No. 12 : Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
37.74
-
1060.99
Item No. 13 : Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top/centre hung , with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted,including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6
(1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
106.26
-
190.56
Item No. 14: Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
87.3
-
100.62
Item No. 15 : Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
16.89
-
818.46
Item No. 16 : 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
17.07
-
1007.45
Underground PVC Pipe Distribution System
-
-
-
Item No. 1: Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
In ordinary soil
1316.31
-
700.71
Item No. 2 : Supplying, fitting, fixing PVC Pipes (IS 12818, 6 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).
A) 160mm dia
1290
-
1565.52
B) 110mm dia
1050
-
741.74
Item No. 3 : Supplying, fitting, fixing PVC unequal tee joining with pipes with solvent cement, testing leakages etc. complete as directed.
Size 160 mm x 160 mm x 110 mm
18
-
1374.6
Item No. 4 : Supplying, fitting, fixing PVC reducer joining with pipes with solvent cement, testing leakages etc, complete as directed.
Size 160 mm x 110 mm
3
-
662.13
Item No. 5 : Supplying, fitting, fixing, joining of PVC end cap fitting with solvent cement as per specification including local carriage, testing leakage etc. complete as directed.
Size : 110mm
21
-
363.45
Item No.6 :Supplying, fitting, fixing 110 mm dia NTP valve at the top of PVC rising pipe of spout chamber as per specification including local carriage, complete as directed.
B) 110mm dia
21
-
3741.83
Construction of Spout Chamber ( 7 Nos.)
-
-
-
Item No. 1 : Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
In ordinary soil
16.47
-
700.71
Item No. 2 : C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
6.18
-
9632.11
Item No. 3 : 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4)
10.29
-
13512.01
Item No. 4 : 12 mm cement plastering including clearing surface and curing complete as directed. In prop. 1: 4
81.36
-
284.71
Item No.5 : Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line including local carriage, testing leakage etc. complete as directed.
21
-
1195.76
Item No. 6 : Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc. complete as directed.
110 mm / 900
21
-
844.89
Item No. 7: Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).
110mm dia
25.2
-
741.74
Item No. 8: Procurement and supply of approved quality canvas pipe of 65 mm dia for water distribution system including all necessary accessories for fitting, sealing joints etc. as directed.
300
-
127.89
Boundary Fencing
-
-
-
Item No. 1 : Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
(a) In ordinary soil
2.94
-
707.83
Item No. 2 : Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
2.94
-
818.46
Item No. 3 : C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
0.21
-
9536.1
Item No. 4/ : R.C.C work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 (M15) with hard river shingles of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
1.41
-
9992.99
Item No. 5 : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered).
(C) Shuttering (Column)
16.17
-
554.36
Item No. 6 : 12 mm cement plastering including clearing surface and curing complete as directed. In proportion 1:4
3.6
-
287.6
Item No. 7 : Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.
10mm dia
12mm dia
6 mm dia
1.27
-
13261.44
Item No.8 : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
247.32
-
176.1
Item No. 9 :Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of hollock wood in scantling of section 50X25 mm, fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge
162
-
703.37
Item No.10 :Planting biofencing plants along the boundary of the pump centre including carrying, labour etc.
864
-
51.04
Installation of Sign Board
-
-
-
Item No. 1 : Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed.
3
-
12875.68
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements