Irrigation Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 80,468Document Cost
₹ 1,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ID_37011_1Bid Award Id
ViewTender No
NIT NO. 10/2023-24Tender Authority
Irrigation Department ViewPurchaser Address
-Website
http://assamtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying wooden hammer of size 15 cm x 10 cm with 45 cm long & 5 cm wodden handle etc, complete as directed
8
-
958.22
Supply & Lowering of Pipes , Shrouding of TW, Developing of TW , MS Clamp Pump Support
-
-
-
Boring : - Boring of DTW of bore hole up to 350 mm dia and up to a depth of 45 M or up to required depth by RC/DR Drilling Rig including supply and transportation of all required Tools & Plants, materials & Labour to site to perform the job in complete as directed in alluvium areas (means areas where the strata comprises of loose, unconsolidated materials like clays, silts, sands gravels, pebbles, cobbles and boulders) as per IS: 2800 (part-I) of 1991. ( Soil sample must be collected & keep properly at every 3.00 M interval of depth in boring. The job also include movement of Rig by making temporary approach road etc. to the field up to distance of 1000 M.)
180
-
5665.83
Supply & Lowering of Pipes : - Supply lowering & installation in tube well 150 mm PVC housing pipe, blind pipe of wall thickness of 10.00 mm to 11.2 mm for casing assembly including supply of well cap , socket, reducer ,MS housing clamps etc. As required as per IS 12818-1992 of length 1.00 m 2.00 m of reputed brand like Supreme, Oriplast, Jindal,Prince etc. and as directed.
132
-
3026.7
Supply & Lowering of Filter Pipes : - Supply lowering & installation in tube well 150 mm PVC Ribbed Screen filter pipe of wall thickness of 10.00 mm to 11.2 mm for casing assembly including supply of socket, reducer etc. As required as per IS 12818-1992 of length 1.00 m 2.00 m of reputed brand like Supreme, Oriplast, Jindal,Prince etc. and as directed.
48
-
4067.53
Supply & Installation of Valve : 65 mm dia Sluice Valve
4
-
1212
Shrouding of TW :- Shrouding of the Tube well assembly by packing of river Pea Gravel of size 4mm to 8 mm free from sand, dust and any other foreign materials after staking at site including screening, washing etc as per IS 4097/2008 along with transportation, labour etc. complete as directed and (Packing to done after lowering tube well assembly and also during development as reqd) As per Annexure II
28
-
8082.25
Developing of TW : - Developing the tube well assembly by Air-Compressor of capacity 8 – 12 kg/Sqcm and CFM = 450 CM/Min so as to get sand free discharge of water including trial pumping and providing following data as directed ; 1. Static water level
2. Drawdown at various discharge 3. Available average discharge (Arrangement of Pump for trial pumping is in the scope of the work)
96
-
3721.37
MS Clamp Pump Support :- Supplying, fitting, fixing of 150 mm dia MS clamp of size 15 mm thick and 150 mm width having projection of 300 mm and three holes of 20 mm dia for clamping the plates by 16 mm dia hexagonal bolts of length 75 mm and nuts on both sides encircling the column pipe including two coat of enamel paint over one primary coat of different dia all complete as directed and specified.
8
-
1616
Supply, Installation and Commissioning of Solar Pump along with PV Panles etc.
-
-
-
(a) Supply & Installation of Solar Pumping System : Solar Submersible Standalone Pump set with 3 HP AC Induction motor and Solar Power Controller Unit ( Conform IEC 6168311:1999) with overload, over-under voltage, short circuit protection, suitable for 150 mm bore well and discharge capacity approx 400 LPM at 10 M head (Dynamic Head Range 10-30 Mtr and Shut off head 35 M) working at 3000 Wattp of solar power along with Cables, Inverter external box, surge suppressor, DC MCB & all necessary accessories like, 2(two) pairs of Assembly support clamps, 10(ten) nos. of Cable clamp / clip, 1 (one) no. of Delivery bend, 20(twenty) mtr. column pipe, 1(one) no. of Short pipe of 1.5 Mtr. length of required diameter, 40(forty) mtr.(approx.) Flat flexible cable (motor to controller) as per latest MNRE norms and as per IS.
-
-
-
(b) Testing & Commissioning : Supply, fitting-fixing and testing & commissioning of Solar PV modules conforming to IEC 61215 specification or equivalent National or International standards consisting of solar panels framed in anodized aluminium frame of 3000 Wp (approx.) considering 7.15 kWh/ M2/ Day of solar insolation under standard test condition on horizontal surface with tolerance (+/-) 15% and hot dipped galvanized(minm 80 micron thickness) mounting mild steel structure of rectangular hollow sections, angles, heavy duty pipes of dia 150 mm (all materials duly IS marked ) for providing sufficient strength with dual axis manual tracking arrangement which can withstand load of modules and high wind velocities upto 150 Km/hr including RCC foundation designed against all possible loads (Dead, Live and imposed load), Controller conform to IEC 61683–1999 & IEC 60068-1-2, IEC 60068 – 2- (2, 14, 30, 78) ( The series and parallel combination of Solar Modules to be done in such a way that Jalverter/ Controller input voltage requirement is met i.e. System Vmp 587 V & System Voc 800 V) and necessary connection cables, pipes to the water trough and other accessories, etc. complete in all respect as directed . (Controller to be installed with suitable arrangement on the body of the pole of mounting structure with rain proof provision. SPV panel should be of reputed make like TATA/Bikram/ Waaree etc. and carry at least 20 years warrenty & comprehensive maintenance for 1 year and should installed preferably above HFL)
-
-
-
(C) Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. Below the ground level as below: (a) By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanized (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
-
-
-
(d) Lightning protection : Lightning protection (Arrestor)(pole mounted)(: Lightning protection with 3" X 1.5" G.I pipe of 4 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc including supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the /Roof with GI Saddles 1100 mm apart. ( As per MNRE circular no. 318/38/2018-GCRT dt. 25.07.19 )
-
-
-
Solar Pump set should be of reputed make and carry 5 years warranty / guarantee. Flow Range : 90 L per Wp of PV array from TDH of 10 M Controller DC Input Voltage : (i) System Vmp 587 V & (ii) System Voc 800 V Controller Conforming to : IEC 61683 - 1999 & IEC 60068 - 1-2, IEC 60068 - 2-(2,14,30,78) This bence mark cost are for the systems installed as per MNRE specifications inclusive of the total cost of system and its installation, commissioning, transportation, insurance, warranty/ guarantee, monitoring & maintenance for five years.
4
-
259153.32
LT Electrical Power Connection
-
-
-
Supply and erection of 7.5 metre long PSC pole of standard dimension for 230 Volt overhead line including digging of Earth pit (0.75 m ´ 0.5 m) having a depth of 1/5th of the pole length with PCC Base Plate of size 60 cm ´ 60 cm ´ 12 cm at the bottom, refilling with boulder packing (size 150mm to 200 mm), refilling the voids with soil and hard ramming as directed.
24
-
11708.24
Supply and Erection of LT Stay Set complete Supplying and Erection of LT Stay Set comprising of Stay Rod, 19mm dia × 1.8 m Anchor Plate, Bow, Thimble etc. including supply and erection of 7/12 SWG G I Stay Wire and LT Guy Insulator complete including digging of Earth Pit of size (0.9m × 0.9m)to a depth of 1.4 Metre, placing the Stay Rod with Plate, fixing thimble, bow etc. with Boulder packing (size 150mm to 200mm)and hard ramming to fill up half the pit and filling with hard soil packing upto the Ground Level as directed
8
-
2826.95
Anchor clamp LT ABC
24
-
525.2
LT XLPE Insulated ABC 1Cx35 Sq mm+1C 25 Sq mm
600
-
121.2
I . Hook
24
-
90.9
Suspension Clamp for ABC as per NFC Standard
24
-
656.52
ASA Distribution Box 40 A 1 Ph
4
-
3535
LT Guy Insulator
8
-
454.5
DP MCB With Enclosure
4
-
1515
Medium quality GI Pipe 40 mm dia for Service Connection
24
-
404
Supply laying and connection of XLPE insulated Aluminium conductor armoured cable,10 sq mm× 2 Core (For Service Connection from Pole to Panel Board)
200
-
131.3
Erection of Static Electronic Energy Meter including payment of Meter Cost to APDCL, testing of the installation and power connection to the installation complete as directed.
4
-
9518.65
EXIM Meter
4
-
4646
Sundry Materials
4
-
1212
Transportation Cost
4
-
6023.26
APDCL Supervision Charge,Storage Charge etc
4
-
6023.26
Sign Board : Supply of Sign board made of 1.60 mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75 m fixed with 2 Nos. 50 mm dia GI (medium) pipes 2.10 m above and 0.60 m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed.
4
-
12221
Canvas Pipe : Supply of Canvas Pipe 65 mm Dia of reputed make
840
-
121.38
Evaluation Notes How It Works ?
Potential Partner