Irrigation Department Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Irrigation Department Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date12 Dec 2023
Closing Date1 Jan 2024
Tender Amount₹ 1,42,91,418 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(B) For 1st KM of Quarry Road

63.94

-

110.41

... More
Item No. 3 : Labour charges for spreading hard river shingles / sand gravels to required thickness over approach subway etc. including ramming, dressing the seat before laying the materials lead upto 30.00 M and lift 1.50 M. Complete as directed.

63.94

-

471.18

... More
Construction of Bank protection works

-

-

-

... More
Cutting jungles and trees upto 50 cm girth including uprooting roots and stumps and removing them from site of work etc, complete as directed.(ii) Medium jungles

264.5

-

26.67

... More
Earthwork in filling in all soils in plinth, canal embankment and bed filling as per design section and grade by truck carriage for a minimum distance of 4 KM including paying compensation of earth obtained from private land if any loading, unloading, spreading the same including light jungle, removing trees upto 15 cm dia and uprooting roots and stumps etc. from the seat of the embankment, breaking clods not more than 10 mm cube, ramming, profiling etc. with all lift, complete as directed. (Payment will be made after deduction of 12.50 % shrinkage allowance from the gross quantity).

294.4

-

819.58

... More
Collection of hard broken stone of size 13 mm to 38 mm from blasted boulder free from dust and dirt and foreign materials including stacking at quarry site, complete as directed.

55.66

-

3442.46

... More
Collection of one man size 25 cm to 30 cm hard river boulder including stacking in measurable stacks of not more than 1.00 M height at quarry site and making payment of forest royalty etc, complete as directed.

83.49

-

1092.89

... More
Carriage of boulders, gravels, metal screening, stacking in measurable stacks at site, complete as directed A) For Normal Road upto 25.00 KM

139.2

-

1164.8

... More
Labour charge for spreading hard river gravel/broken stone of size 13mm to 38mm to the required thickness including ramming, dressing the seat before laying the materials as directed with lead up to 30m & lift upto 1.5m complete as directed.

55.66

-

489.72

... More
Labour charge for pitching with one man size boulder including dressing and ramming the seat to proper size and slope, pitching etc. with local carriage of boulders from a distance of 60 M with lift upto 3 M, complete as directed.

83.49

-

910.3

... More
Construction of 1.00 M x 1.00 M rectangular boulder sausage including supplying of materials with 25 cm to 30 cm size boulders collecting from a lead of 25 KM encased in 15 cm mesh of 8G hexagonal wire netting and filling the voids between the boulders with stone not exceeding 18 cm in size tied with 8G galvanized tying wire at 30 cm apart, laid in position as directed including necessary local carriage of materials, paying necessary forest royalty including providing 1 (one) no. of jati bamboo horizontal runner along the top of the sausage with vertical bhaluka bamboo post 1.20 M apart driven at least 0.60 M below ground and tying with sausage etc, all complete as directed.. With river boulder

138

-

7780.84

... More
Construction of Underground PVC Pipe Distribution System

-

-

-

... More
Item No. 1: Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. In ordinary soil

1423.2

-

700.71

... More
Supplying, fitting, fixing PVC Pipes (IS 12818, 6 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately).200mm dia

710

-

2540.54

... More
160mm dia

570

-

1565.52

... More
110mm dia

1685

-

741.74

... More
Supplying, fitting, fixing PVC equal tee joining with pipes with solvent cement testing leakages etc, complete as directed. Size 160 mm x 160 mm x 110 mm

2

-

2049.75

... More
Size 110 mm x 110 mm x 110 mm

17

-

968.2

... More
Supplying, fitting, fixing PVC unequal tee joining with pipes with solvent cement testing leakages etc, complete as directed. Size 2000 mm x 200 mm x 110 mm

10

-

4147.32

... More
Size 160 mm x 160 mm x 110 mm

4

-

1374.6

... More
Supplying, fitting, fixing PVC reducer joining with pipes with solvent cement, testing leakages etc, complete as directed. Size 200 mm x 160 mm

2

-

1189.13

... More
Size 160 mm x 110 mm

4

-

662.13

... More
Supplying, fitting, fixing, joining of PVC end cap fitting with solvent cement as per specification including local carriage, testing leakage etc. complete as directed. Size 110 mm

17

-

363.45

... More
Construction of Spout Chamber (17 Nos.)

-

-

-

... More
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. In ordinary soil

11.95

-

700.71

... More
Soling in foundation in floor at all level septic tank etc. including filling interstices ramming etc. complete as directed and as specified thickness (i) 9 cm brick on flat including sand packing.

26.56

-

843.18

... More
C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).

1.99

-

9632.11

... More
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (In proportion 1:4)

8.75

-

13512.02

... More
12 mm cement plastering including clearing surface and curing complete as directed. In prop. 1: 4

66.91

-

284.71

... More
Supplying, fitting, fixing 110 mm dia PVC Rising pipe from the toe of main line including local carriage, testing leakage etc. complete as directed.

17

-

1195.76

... More
Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc. complete as directed. 110 mm / 90 degree

17

-

844.89

... More
Supplying, fitting, fixing PVC Pipes (IS 12818, 4 kg/cm2), joining pipes with relevant cement, levelling, testing leakages etc. complete as directed. (Cost of E/W foundation trenches will be paid separately). 110mm dia

20.4

-

741.74

... More
Supplying, fitting, fixing 110 mm dia NTP valve at the top of PVC rising pipe of spout chamber as per specification including local carriage, complete as directed.

17

-

3741.83

... More
Construction of Control Room

-

-

-

... More
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. (In ordinary soil)

13.61

-

707.83

... More
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.

9.36

-

818.46

... More
CC Work in proportion 1:3:6 in foundation /abutment/ pier/wing walls etc. with hard broken stone aggregate of size 13 to 38 mm including curing with necessary shuttering , Scafolding etc. where necessary, complete as directed. (shuttering where necessary shall be measured and paid separately).

1.3

-

9536.11

... More
Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.

17.02

-

13261.44

... More
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered). (C) Shuttering (Column)

109.14

-

554.36

... More
RCC work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:1½:3 with hard broken stone aggregate of size 6 mm to 20 mm with proper reinforcement as per design including curing etc, complete as directed with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately).

11.86

-

12225.46

... More
Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level.

30.47

-

888.66

... More
12 mm cement plastering including clearing surface and curing complete as directed. b) In cement mortar 1:4

126.52

-

287.6

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) ( Sal wood)

0.22

-

115776.58

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) (9.5.1 Second class teak wood) (35 mm thick shutters)

4.9

-

4018.79

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (Hot finished welded type tubes)

236.57

-

168.05

... More
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

33.08

-

728.53

... More
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)

5.05

-

488.83

... More
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). (6 mm thick Cement bonded wood particle board as per IS:14276)

16.25

-

815.05

... More
Supplying fitting and fixing iron grating in windows MS rod (round) fixed at not more than 13 cm c/c apart with one line of 40 mm x 10 mm size MS flat horizontal middle including painting the iron work two coats with approved paint etc, all complete as directed. (12 mm dia Bar)

4.8

-

1762.07

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. (Two or more coats on new work)

126.52

-

100.62

... More
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture

13.8

-

157.19

... More
Installation of 40 mm dia Shallow Hand Tube Well

-

-

-

... More
Labour charge for making bore hole of 50 mm dia up to required depth below ground level and collecting sample of soil at every 3.0 m depth or wherever there is a change of strata in sample boxes with the distinguishing marks including arranging and carriage of cessary boring materials / tools etc. and withdrawing the pipe all complete as directed. (a) For 0 to 50 m depth

40

-

161.47

... More
Labour charge for sinking, lowering, fitting, fixing in position 40 mm dia U.P.V.C. pipe with 40 mm dia strainer placed in potable water bearing layer with 40 mm dia cone / plug at the bottom of the tube well, washing the bore well etc. and supplying necessary jointing materials cutting and threading the pipe where necessary including carriage of materials and cleaning and priming the tube well all complete as directed.

40

-

11.88

... More
Labour charge for packing coarse sand around strainer and casing pipe including supplying and carriage of materials all complete as directed and specified.

40

-

12.4

... More
Singur Hand Pump(Suction type hand pump as per specification finalised by the Bureau of Indian Standard (BIS),specification of Shallow well suction - Type hand pump "Singur" as an up-gradation of the existing IS:8035-1976 and has allotted the temporary IS:code as HMD-27(0395)PL/AUG 1996 and as approved by the "UNICEF")

1

-

6549.63

... More
Construction of platform of conventional tube well with cement concrete works in proportion 1:2:4 of 1.50 m dia (outside to outside) in two layers with a base layer of concrete of proportion 1:4:8 as per approved drawing No. C.E.(PHE) - 03/05 including necessary earth work and refilling after completion of work all complete as directed.

1

-

4336.88

... More
Cost of Materials : 40 mm dia GI Nipple 1 M length

1

-

341.34

... More
40 mm dia casing pipe

36

-

191.62

... More
40 mm dia Rib Screen pipe

3

-

247.75

... More
Construction of Boundary Wall

-

-

-

... More
Item No. 1 : Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified. (a) In ordinary soil

22.68

-

707.83

... More
Item No. 2 : Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing. Flat brick soling

22.68

-

818.46

... More
Item No. 3 : C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).

1.7

-

9536.11

... More
Item No. 4 : R.C.C work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 (M15) with hard river shingles of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).

9.43

-

9993

... More
Item No. 5 : Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered). (i) Shuttering (Column)

65.98

-

554.36

... More
(ii) Shuttering (Beams) with out props

28.8

-

225.43

... More
Item No. 6 : 1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete. (a) In proportion 1:4

8.92

-

13115.9

... More
Item No. 7 : 12 mm cement plastering including clearing surface and curing complete as directed.In proportion 1:4

135

-

287.6

... More
Item No. 8 :Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

135

-

181.01

... More
Item No. 9 : Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed. 10mm dia Bar 12mm dia Bar 6 mm dia Lateral Tie @ 150 C/C

8.7

-

13261.44

... More
Item No. 10 : GATE Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.(Separate payment will be made for posts). 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (Separate payment will be made for posts).

202.5

-

154.38

... More
Item No. 11 : Earthwork in filling in Marginal bund / Guide bank / Afflux bund / Canal embankment etc. to the design section and grade by obtaining earth from outside borrow pits and filling in uniform layer not exceeding 15cm thick including clearing light jungle, removing trees upto 15 cm dia and uprooting roots and stumps from the seat at embankment and borrow pit area, breaking clods not more than 10mm cube, ramming, watering, dressing and roughening the seat of embankment, profiling etc. Paying compensation of earth borrowed from private or forest land if any, lead upto 30 M and lift upto 1.5 M complete as directed.

69.42

-

498.31

... More
construction of Supporting Pillar

-

-

-

... More
Item No. 1: Earth work in excavation of foundation of canal structures in all types of soil as per design and drawing dressing the foundation, shoring, etc. removing the surplus spoils by head load to a safe distance from the working place and depositing required spoils in uniform layers dressing, watering, breaking clods to not more than 10mm cube with compaction complete as directed at site (including bailing out stagnant water where necessary). a. All type of soil except soil mixed with gravel and boulders For normal lead of 30m and lift of 1.50m

4

-

365.99

... More
Item No. 2 : Soiling in foundation floor at all levels including filling interstices,ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.

2.43

-

826.71

... More
Item No. 3: C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).

0.24

-

9632.21

... More
Item No. 4 : R.C.C. work in slab, abutment cap and above abutment, pier cap,pedestals, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering ,scaffolding etc. where necessary complete as directed.( shuttering, scaffolding will be paid separately).

0.88

-

11915.68

... More
Item No. 5: Centering and shuttering including propping etc. where necessary and removal of forms after completion of C.C. and R.C.C. works as directed complete (measurement to be taken on the face area timbered). Column

8

-

559.95

... More
Item No. 6 : Supplying, fitting, fixing and laying reinforcement (TATA approved quality ) in position in R.C.C. work, including cutting, bending, cranking with two plies 0.91mm (20 BWG) annealed wire hooking tying complete as directed. 10mm dia 12 mm dia 6 mm dia

0.53

-

13395.09

... More
Item No. 7: 12 mm thick cement plastering including clearing surface and curing complete as directed in prop. 1:4

6.65

-

290.5

... More
construction of Sign Board

-

-

-

... More
Item No. 1 : Supply of sign board made of 1.60mm thick MS iron sheet fitted with steel frame of size 1.05 m x 0.75m fixed with 2 Nos. 50mm dia GI (medium) pipes 2.10m above and 0.60m below ground fitted with C.C. work in proportion 1:3:6 and size 0.45m x 0.45m x 0.60m below ground including painting with approved paint including writing letters complete as directed.

1

-

12875.68

... More
(B)MECHANICAL PART Supply, Fabrication, laying , Installation & Comissioning of Barge. STEEL FLOATING BARGE OF SIZE : 6.15 m × 4.58 m × 1.37 m

-

-

-

... More
Bottom, side & deck portion of the Barge: Supply & fabrication of M.S. Plate , M.S. Angle, etc. of bottom side & deck portion of the barge of size, 6.15 m × 4.58 m × 1.37 m along with supply & fabrication of M.S. Channel for installation of pump sets, M.S. Angle for pipe support, etc, complete as directed by the Department as per drawing. The job also includes painting of the barge with 2 (two) coats of anticorrosive metal primer followed by 2 (two) coats of anticorrosive black bituminous paints, complete as directed by the Department. Each successive coat of the paint is to be applied after normal drying of the previous coat, complete as directed by the Department. [As per Analysis I,I(A),I(B),I(C),I(D),I(E),I(F) enclosed alongwith]

1

-

764264.98

... More
Roofing, Truss & Railing of the Barge: Supply, fabrication & erection of roof support of height 1.9 m providing post of M.S. Angle, CGI Sheet with necessary clamping & welding at the top of the barge along with roof truss & purlin made of M.S. Black pipe fitted with necessary welding & bolting, complete as directed by the Department. [As per Analysis II,II(A) enclosed alongwith]

1

-

155632.7

... More
Anchoring Materials of the barge: Supply, fitting & fixing of C.I. Bollard on the corner edge of the platform deck of the barge facing towards the riverbank by suitable size of HDMS Nuts & bolts including supply of good quality 19 mm dia. HD Steel wire rope, steel core, tested quality to be fastening with the Anchor 5 Prong 30 Kg. by means of suitable size of required nos. of ‘U’ bolts complete as directed.[As per Analysis III enclosed alongwith]

1

-

462120.45

... More
Procurement of pump sets & Installation, Testing & Commissioning

-

-

-

... More
Cost of Pump Set Self Priming Centrifugal pump set (Size : Suction 150 mm and delivery 150 mm dia) 60 LPS minimum discharge at 10.00 mtr head (approx), working efficiency at head range 2.00 to 15.00 mtr (Make : Reputed brand) and to be coupled with H.D. squirrel cage induction motor having E/B class insulation conforming to IS - 325/78 (Make : Reputed brand) to be connected to power source 400/440 V, 50 Hz, 3Ph complete with 415 V, 50 Hz, 3 ph FASD starter in sheet enclosure, coupling, HD base frame , fitted in accurate alignment. ( Detail is in Encloser A)

2

-

276026.84

... More
Installation of 20 H.P Centrifugal Pump set on (Horizontal Split casing type, size: 150 mm(suction) x 125 mm dia. (delivery) of 60 LPS minimum discharge at 13.00 Mt head coupled with 3 ph, 415 V, 50 Hz, 1450 RPM squirrel cage induction motor of complete Pumpset. The job includes necessary transportation of pump set to the site and its installation on Barge/ Pontoon in proper position with accurate alignment by means of foundation nuts and bolts, etc. including testing & commissioning at site at full load condition complete with all works.

2

-

23319.7

... More
Starter Stand: Supply & Installation of MS Starter Stand made of MS Angle of size 50mmx50mmx5mm including of providence C.C Block Foundation for installation of starter stand along with the required cement concrete works etc. The work includes painting of the starter stand with 1(one) coat of red oxide metal primer to be followed by 2(Two) coats of anticorrosive smoke grey paint to be applied after air drying of each previous coat.

2

-

8615.67

... More
Supply and compressing of graphite greased gland packing of reputed quality as required quantity around the rotating shaft of the pump set against the gland pressure plate to form a water tight seal and adjusting with the help of gland nut in order to accommodate continuous operation.

2

-

1250.27

... More
Laying and connection of cables such as Feeder cable, priming motor cable, lighting cable etc. i) 35 sq mm x 3 ½core

2

-

1414.42

... More
supply, laying & installation of Suction and delivery pipes & accessories including Surge Tank

-

-

-

... More
Suction Pipes & Accessories C.I. Foot valve : Heavy Duty CI Foot Valve, Flange type, the holes of the flange should be drilled as per BSS No. 10, Part -1, Table- D. The materials of construcation and all componenets of the Foot Valve should strictly conform to IS : 10805 - 1986 and having marked with manufacture's name and trade mark. Size : 150 mm dia. Make : Kirloskar/ Upadyaya/ Zolato/ Venus & Equivalent.

2

-

10845.38

... More
G.I. Pipes : Fabricated heavy duty G.I. Pipe confirming to IS 1239 (Part-I) 2004, with G.I. Flange at both end (G.I. Flange having 8 nos. holeas per B.S.S.-10 Part-I, table-D, of Size : a) 150 mm Ф x 0.30 mtr Long

3

-

3813.76

... More
b) 150 mm Ф x 0.90 mtr Long

2

-

5482.28

... More
c) 150 mm Ф x 3.00 mtr Long

6

-

11918

... More
GI Bend : Fabricated heavy duty G.I. Bend confirming to IS– 1239 (Part-I) 2004, with G.I. Flange at both end (G.I. Flange having 8 nos. hole as per B.S.S.-10 Part-I, table-D, of size : a) 150 mm Ф x 90°.

2

-

5482.28

... More
b) 150 mm Ф x 45°.

2

-

5601.46

... More
FLEXIBLE RUUBER HOSE PIPE : Flexible rubber hose pipe as per construction schedule with required nos of wire reinforcement inside at different layers, without / with MS built in type flange coupling on both ends having drilled as per BSS No. 10, Part – I, Table – D. The hose pipes should be capable of withstanding a pressure equal to 1.5 times the designed working pressure without failure as per IS : 443 - 1975 and also withstand vacuum drawn upto 625 mm of mercury (approx.).The schedule of construction of the hose pipe should conform to IS : 3549 – 1983. B.With MS built in type flange 150 mm nominal dia X 4.50 Mtr in length

2

-

20856.5

... More
Fitting, fixing and laying of G.I. Pipes with Accessories in Suction side: Laying, fitting, fixing and connection of suction pipe line for each pump set with 150mm dia. G.I. pipes of different length, fabricated G.I. pipes with different length, fabricated bends, tapper including foot valve for suction side. Reflex valve, sluice valve for delivery side of each pump set with 125mm dia. G.I. pipes with different length, bends, fabricated G.I. pipes with different length as per drawing. The joints should be with the best quality pipe joining sets of required size comprises of 60mm thick black moulded rubber gasket, necessary nuts, bolts and washer. Every joint should be leak proof and should be completed in all respect from foot valve to the pump flange for suction side and fr4om delivery flange is the water flow through at proper F.S.L for the delivery side. The pipes lines with accessories must be proper painting.

29.7

-

976.82

... More
Providing, fitting, fixing and erection of pipe supports for each pipeline at on interval of 3.00 Mtr. (approx) made of M.S. Channel (ISMC 75) 1.50 Mtr. height with angle bracing erected on CC block of size 0.45mX0.30mX0.60m below ground.

8

-

4492.79

... More
Delivery Pipes & Accessories Supply, Fitting-fixing of Heavy duty CIDF sluice valve inside screw, non raising, vertical spindle type with hand wheel operation, need for water purpose. The rotation of closing should be counter clock wise. The holes of the flange should be drilled as per BSS No. 10, part-I, Table-D. All materials construction and components should strictly conform to IS:14846 – 2000 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed/ as per drawing along with HD GI flange, pipe jointing materials and painting in complete as directed (iii) 150 mm dia

2

-

16081.04

... More
Supply, Fitting-fixing of Heavy duty CIDF Reflex valve, swing check type, with bypass arrangement, horizontal operating.The holes of the flange to be as per BSS No. 10, Part-I, TableD and the material, construction and all components should strictly conform to IS : 5312 (Part-I) – 2004 and having marked with manufacturers name and trade mark in the delivery pipe layout as directed/ as per drawing along with HD GI flange, pipe jointing set and painting in complete as directed (iii) 150 mm dia

2

-

16788.04

... More
G.I. Pipes : Fabricated heavy duty G.I. Pipe confirming to IS 1239 (Part-I) 2004, with G.I. Flange at both end (G.I. Flange having 8 nos. hole as per B.S.S.-10 Part-I, table-D, of Size : a) 150 mm Ф x 0.30 mtr Long

3

-

3813.76

... More
b) 150 mm Ф x 0.90 mtr Long

2

-

5482.28

... More
b) 150 mm Ф x 2.00 mtr Long

2

-

9296.04

... More
Fitting -Fixing of MS/GI Tee of 150 mm with GI/fabricated GI pipes with flange at three end and pipe jointing sets, including painting as per drawing & specification as directed.

1

-

3658.04

... More
Fitting, fixing and laying of G.I. Pipes with Accessories in Delivery Side : Laying, fitting, fixing and connection of suction pipe line for each pump set with 150mm dia. G.I. pipes of different length, fabricated G.I. pipes with different length, fabricated bends, tapper including foot valve for suction side. Reflex valve, sluice valve for delivery side of each pump set with 125mm dia. G.I. pipes with different length, bends, fabricated G.I. pipes with different length as per drawing. The joints should be with the best quality pipe joining sets of required size comprises of 60mm thick black moulded rubber gasket, necessary nuts, bolts and washer. Every joint should be leak proof and should be completed in all respect from foot valve to the pump flange for suction side and fr4om delivery flange is the water flow through at proper F.S.L for the delivery side. The pipes lines with accessories must be proper painting.

6.7

-

976.82

... More
Surge Tank : Supply, fitting-fixing of Surge Tank of size 900 mm dia x 1250 mm long made of 4 mm MS plate with Raiser assembly of size 75 mm dia x 6.0 M long and S-bend of size 200 mm x 1600 mmL made of 4 mm MS plate including painting the above with one coat of synthetic enamel primer followed by 2 (two) coats of successive synthetic enamel/ bituminous black paint and made provision for mounting the surge tank on a specified CC foundation by nuts & bolts of suitable size as per drawing & specification as directed.

1

-

143273.86

... More
SUPPLY OF MISCELLANEOUS ITEMS Hacksaw blade (12MM X 300MM)

1

-

297.95

... More
M.S. Nuts & Bolts (Assorted Size) B.Q.

8

-

208.57

... More
M.S. Washer (Assorted Size) B.Q.

8

-

143.02

... More
G.I. Nipple (both end threaded) of length 0.30 m. b) 150 mm dia.

5

-

834.26

... More
M. Seal (100 grams Pkt.)

5

-

95.34

... More
Emery cloth

5

-

333.7

... More
Waste cotton (Best Quality)

5

-

214.52

... More
W B grease (Best Quality)

7

-

357.54

... More
Steel wire brush (Std. Size) (Best quality)

4

-

143.02

... More
Pipe jointing set complete with 6 mm thick moulded Rubber Gasket, M.S. Nuts & bolts with washer suitable for:c) 150 mm dia flanged pipe

4

-

655.49

... More
Nylon rope (16 mm to 25 mm dia) (Best quality).

20

-

297.95

... More
Manila rope (16 mm to 25 mm dia) (Best quality)

20

-

417.13

... More
(C)ELECTRICAL PART Erection of H.T. Line (700 M Length) & Transformer Sub Station

-

-

-

... More
HT Electrical Part Surveying and finalising the suitable tapping point in existing nearby 11 kV line in consultation with APDCL and Departmental Officers, marking the alignment of the line considering Right of Way, Feasibility etc. as required and as directed For first 500Mtrs. (As Per SOR ELE 2023-24, 6.1 A)

1

-

6113.93

... More
For every subsequent 100 M beyond 500 M Length (As Per SOR ELE 2023-24, 6.1 B)

3

-

1191.8

... More
Jungle cutting including cutting of branches of trees and reclining Bamboos along the alignment of the overhead line providing clearance 1.5M either side and above the line as directed. Clearance must be ensured at the time of charging the line (As Per SOR ELE 2023-24, 6.2)

700

-

47.67

... More
Supplying & Erection of PSC Pole conforming to IS 1678 of Standard Dimension and of following lengths for overhead Electric Lines including digging of Earth Pit (0.75m × 0.5m) to a depth ⅕th of the Pole Length with a PCC Base Plate of size 60 cm × 60 cm × 12 cm at the bottom, refilling as specified with hard ramming as directed. (I) Refilling with Hard Soil (As Per SOR ELE 2023-24, 6.3 C, (i), A) 9.75 Metres

33

-

17042.74

... More
Supplying and erection of GI Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with GI Clamps, GI Nuts & Bolts including drilling of necessary holes as directed. (Size: 100mm × 50mm × 6mm × 2200 mm)(As Per SOR ELE 2023-24, 6.5.2 D)

4

-

4244

... More
Supplying and Erection of 11 kV HT Stay Set comprising of 19mm dia × 1.8 m Stay Rod, Anchor Plate, Bow, Thimble etc. including supply and erection of 7/10 SWG G I Stay Wire and 11kV Guy Insulator complete including digging of Earth Pit of size (0.9m × 0.9m) to a depth of 1.4 Metre, placing the Stay Rod with Plate, fixing thimble, bow etc. with Boulder packing (size 150mm to 200mm) and hard ramming to fill up half the pit and filling with hard soil packing upto the Ground Level as directed (As Per SOR ELE 2023-24, 6.5.7 A)

4

-

3737.48

... More
Supply and Erection of 11 kV Grade Aero Bunched Cable with 3(three) Power core, Stranded compacted, Circular Aluminium Conductor screened with black extruded semi conducting compound natural colour XLPE insulated core screened with black extruded semi conducting compound and one layer of copper tape and covered with black extruded PVC and one Bare messenger wire shall be stranded non-compacted circular aluminium alloy conductor. the cable should conform to IS:8130-1984, IS:398(Part-IV) 1994, IS:7098(Part-II) 2011 & IS:5831-1984 with up to date amendments. The job includes necessary Cable Joint, End Terminations, Anchor Clamp, Supension Clamps, Eye Hooks etc as directed by department. iii) 3 x 95 sqmm(P) + 1 x 70 sqmm (M) (As Per SOR ELE 2023-24, 10, A, c)

700

-

1762.67

... More
Supplying and Erection of Hardware Fittings (3u bolt) on existing MS / GI Channel Cross Arm with GI Nuts and Bolts for mounting 11 kV Disc Insulator 45 kN as directed (As Per SOR ELE 2023-24, 6.6.4)

3

-

642.38

... More
Supplying and Erection of 11 kV Polymeric Disc Insulator 45 kN on existing Hardware Fitting on Cross Arm as directed.(As Per SOR ELE 2023-24, 6.6.5.B)

3

-

800.89

... More
Supplying and Erection of 11 kV Polymeric Pin Insulator 5 kN on T Cross Arm/ Channel along with GI Pin, GI Nuts & Bolts including Drilling of Holes as directed. (As Per SOR ELE 2023-24, 6.6.3, B )

3

-

774.67

... More
Danger Plate suitable for 11 KV Line confirming to IS:2552/1963 of size 250mm x 200mm (As Per SOR ELE 2023-24, Group-C Supply of Miscellaneous Items, 52)

10

-

143.02

... More
Supply & Erection of Anti Climbing Barbed Wire on Poles at a height of about 3 Metres and covering a length of 1.5 Metre as directed (As Per SOR ELE 2023-24, 7. 14)

15

-

378.99

... More
TESTING & COMMISSIONING OF HT LINE Testing and commissioning of the 11kV line including making payment for necessary Inspection Fee and obtaining charging approval from competent authority (Electrical Inspectorate) as directed. (As Per SOR ELE 2023-24, 7.15)

1

-

8483.23

... More
Transformer Sub Station Supplying & Erection of PSC Pole conforming to IS 1678 of Standard Dimension and of following lengths for overhead Electric Lines including digging of Earth Pit (0.75m × 0.5m) to a depth ⅕th of the Pole Length with a PCC Base Plate of size 60 cm × 60 cm × 12 cm at the bottom, refilling as specified with hard ramming as directed. (I) Refilling with Hard Soil (As Per SOR ELE 2023-24, 6.3 C, I, A) 9.75 Metres

2

-

17042.74

... More
Supplying and erection of GI Channel Cross Arm of following sizes for 11 kV Line on PSC/ Steel Poles along with GI Clamps, GI Nuts & Bolts including drilling of necessary holes as directed. (Size: 100mm × 50mm × 6mm × 2200 mm)(As Per SOR ELE 2023-24, 6.5.2 D)

2

-

4244

... More
Supplying and erection of Cross Bracing Sets for 11 kV Line on DP (Double Pole) Structure comprising of 2(two) Nos. of MS Angle of size 50 mm × 50 mm × 6 mm × 2200 mm fitted horizontally and other 2 Nos. 3200 mm long fitted diagonally along with MS Pole Clamps, Nuts Bolts and washer duly painted with Anti Corrosive Primer and Aluminium Paint including drilling of necessary holes as directed (As Per SOR ELE 2023-24, 6.5.6.A)

1

-

9570.15

... More
Supplying, Fitting and Erection of 3-φ 11 kV Gang Operated (G.O.) Air Break Switch having nominal System Voltage of 12 kV, rated Voltage 11 kV, rated Frequency 60 Hz, and peak current in closed position 46 kA, conforming to IS 2544, IS 5340(Part-III) and IS 9921(Part I to V) suitable to opearate in all climatic condition of following current ratings on existing Channels complete with Operating Pipe and Handle including making of necessary Electrical Connections as directed. (400 Amps) (As Per SOR ELE 2023-24, 7. 2 B)

1

-

23887.25

... More
Supplying and Erection of 3-φ 11 kV Drop Out (D.O.) Fuse Unit rated voltage 11 kV R.M.S. To 12 kV R.M.S., highest System Voltage 12 kV, each pole consisting of Polymeric insulator, all current carrying parts made of a highly conductive copper alloy and contact portion are silver plated for corrosion resistance and efficient current flow and the fuse tube made of fibre glass coated with ultraviolet inhibitr on the outer surface and having Arc Quenching bone fibre liner inside conforming to IS 9385/1983 of following current ratings on existing Channels complete with Barrel Fuse and making of necessary Electrical Connections as directed. (150 amp) (As Per SOR ELE 2023-24, 7. 3 A)

1

-

10567.69

... More
Supplying and Erection of Metal Oxide gapless Lightning Arrestor of following specification on MS Channel with Clamps, Nuts & Bolts including drilling of holes and making of necessary connection with Line Conductors as directed. 9 kV, 10 kA with Polymer body (As Per SOR ELE 2023-24, 7. 1 D)

3

-

8778.8

... More
Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed (As Per SOR ELE 2023-24, 7. 9.1 A)

8

-

6028.12

... More
Supply including Erection of 5 Star ON-AN (Oil Natural, air Natural) Cooled Al/ CU-wound Distribution Transformer conforming to IS specifications 2026 (with latest amendments) with all standard accessories erected on double pole structure/ transformer pad including transportation and handling, loading and unloading etc,, securing it on existing Channel firmly with necessary clamps, nuts & bolts . as required, and making necessary connections on HV and LV sides as directed (Cost of DP structure /Pad extra ) Capacity : 63 kVA, 11 kV/0.433 kV (4 Star Dyn) - Al wound, (A) Cost including Supply of Transformer (As Per SOR ELE 2019-20, 8.1.2 A)

1

-

354643.93

... More
Supply & Erection of G.I. Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed. (6 SWG G.I. Wire) (As Per SOR ELE 2019-20, 7. 9.2 A)

120

-

57.44

... More
Supplying including erection of powder coated LT Feeder Panel /Metering Panel for 63 kVA DTR of size (800mm × 1000mm × 400mm) made of 16 SWG CR sheet and 40mm × 40mm × 6mm MS angle having CR sheet roofing containing Cu Busbar and 1 no 125 A 415 V FP MCCB, (35kA) making necessary connection through copper cable complete as directed.. (As Per SOR ELE 2023-24, 7. 11 B)

1

-

57009.75

... More
Supply including Laying of PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor of size 35 Sq mm × 3 core in single line, Conforming IS 7098(Part I) 1988, direct in ground including digging of tren ch of 0.3 Mtr wide × 0.75 Metre deep including Sand Cushioning (7.5cm + 7.5cm) and refilling alongwith fitting, fixing of Brass Compression Gland and Aluminium Cable Lug etc. as directed. (As Per SOR ELE 2023-24, 9.2 A i)

75

-

864.06

... More
Providing Security fencing around the S/S with GI chain link net, woven with 10 SWG wire with mesh 7.5cm × 7.5cm to be erected on GI angle 40 mm × 40mm × 5mm, with necessary C C grouting, with a fencing height of 1.8 mtr, having a hinged door, fabricated with flat GI strip boundary and cross bracing, complete including supply of all materials, excavation refilling etc as reqd and as directed. (As Per SOR ELE 2023-24, 7.16)

28.8

-

1675.67

... More
Testing and commissioning of the Substation alongwith obtaining necessary approval for charging from competent authority including payment of Inspection Fee, Arranging for Test Report etc. as required and as directed for following kVA Capacity (Capacity : 63/100 kVA, 11 kV/0.433 kV) (As Per SOR ELE 2023-24, 8.2.2)

1

-

24014.77

... More
Liasoning with APDCL, Forest Department, Electrical Inspectorate etc. right from start till commissioning of the HT Line/ sub-station, preparation of all necessary documents like Agreement and Affidavit reqd. for power connection, obtaining No Objection Certificate from Forest Department where necessary to complete all arrangement for charging the installation as reqd. and as directed. (As Per SOR ELE 2023-24, 8.3)

1

-

13109.8

... More
Erection & Commissioning LT Whole Current Electronic Energy Meter including making necessary payment to APDCL for Meter Cabinet, Meter Security etc as reqd and as directed. (As Per SOR ELE 2023-24, 7.12)

1

-

40402.02

... More
Load Security to be paid to APDCL (Approx.)

32

-

2860.32

... More
Erection of LT Line and Control Panel

-

-

-

... More
Item No:- 1 L.T. CONTROL PANEL: Supplying, installation, testing& commissioning of indoor type floor mounted, cubicle type compartmental, dust and vermin proof (as per IP-54) main LT Control Panel Board of following capacity and size made out of 16SWG CR sheet and 40mm X40mm X 6mm angle having four nos. of legs 400mm long at the bottom with folded and welded construction having dismantled doors at the back, surface chemically treated and Siemen’s grey powder coated, containing Al. strip Bus-bar having minimum current density of 1.2 Amps/sq.mm, R-Y-B-N colour coded with heat shrinkable insulating sleeves containing all incoming and outgoing electrical accessories as specified, neatly installed and internally wired with best quality multi-strand, PVC insulated single core unsheathed, HRFR Copper Wire( Switch gears above 100Amps rating to be connected to the Bus-bar through Al. strip of suitable size) having cable incoming and outgoing provision at the bottom through gland plates complete including necessary excavation of trench and C.C. Work as directed. Main LT Panel Board Suitable for operation of 2 х 20 HP Pumpset Size :1200 mm(B)х 1200 mm(H)х 400 mm(D) (As Per SOR ELE 2023-24, 1.1.1 B) FP, 415 V 125 Amp MCCB with Short Circuit & Overload Protection, Breaking Capacity 35 / 36 kA as main incomer TP, 63A, 415V , AC Motor Control Switch(SDF) with 63A HRC Fuse Air Break Contactor, TP 32 A, 415 V, AC for Capacitor Duty TP, 415V 32 Amp, MCB for Power Capacitor M.I. Voltmeter, 0-500V, 1% accuracy 96mm х 96mm size Voltmeter Selector Switch, 4 position, 10/15 Amp M.I. Ammeter, CT operated, 1% accuracy 96mm х 96mm size 0 - 100 Amps for Incoming Side 0 - 60 Amps for Outgoing Motor Feeder Ammeter Selector Switch, 4 position, 10/15 Amp Analog Power Factor Meter, 96mm х 96mm size 1% accuracy Current Transformers for metering purpose Accuracy Class I CT, 100/5 for incoming side CT, 60/5 for outgoing side LED type Pilot Indicating Lamp 25 mm DP, 250V, 16A, MCB with breaking capacity 10kA for lighting purposeSP, 250V, 1A, MCB with breaking capacity 10kA for meter protection Aluminium Busbar, 25 mm × 5 mm On and Off Push Button Switch Total Cost of Panel Board

1

-

171797.97

... More
Item No:- 2 Supplying fitting fixing of LT Power Capacitor 415 Volt AC 3 φ (Single Unit) of following KVAR Rating and making connection with Busbar in the existing Panel. The Capacitor is to be placed in existing Platform. (6 kVAR) ( As per SOR ELE, 2023-24 ) (3.2 A)

1

-

3946.05

... More
Item No:- 3 Supplying, fabrication and erection of Iron Angle Stand for erection of LT Power Capacitor made of MS Angle of size 30 mmX 30mm X5 mm with 4 Nos of legs 400mm high and cross pieces having Bakelite Sheet horizontal platform as directed ( As per SOR ELE, 2023-24 ) (3.1 A) Size of the Frame : (300 mm x 300 mm) x 400 mm

1

-

4969.81

... More
Item No:- 4 Supplying including fitting, fixing and connection of TPN Main Switch (SDFU- Switch Disconnector Fuse Unit) with HRC fuses, 415V AC, Open Execution, Panel Mounting type of following rating in already fabricated Control Panel Board housing , along with lugs, connecting cable and all other necessary materials as directed, (100 Amps) ( As per SOR ELE, 2023-24 ) (4.2 C)

1

-

12609.24

... More
Item No:- 5 Supplying including fitting, fixing and connection of three pole 415V, AC 50 Hz Motor Protection Circuit Breaker (MPCB) with adjustable thermal and magnetic setting with rotary handle of following current/HP ratings in already fabricated LT Control Panel Board housing along with lugs, connection cable and all other necessary materials for connection as directed. (32 A / 20 H.P.) ( As per SOR ELE, 2023-24 ) (2.3 C )

2

-

18687.42

... More
Item No:- 6 Supply and Laying of 3 (Three) Core PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor in existing open trench/ in air including fixing with necessary clamps etc. in wall/pole/ other support including End Termination with Brass Compression Gland and Cable Lug as required and as directed ( As per SOR ELE, 2023-24) (9.1 B. ii) Size of Cable : 50 mm2 × 3 Core ( Single Line)

50

-

906.96

... More
Item No:- 7 (SUPPLY & ERECTION OF EARTH PIPE) Supply & Erection of C.I. Earth Pipe 100 mm dia × 2.5 Metre long perpendicular to the ground including digging of Earth Pit, putting Salt and Charcoal in alternate layers surrounding the pipe along with fitting of hinged CI top Cover Plate and necessary C.C. work as directed ( As per SOR ELE, 2023-24) (7.9.1 A)

2

-

6028.12

... More
Item No:- 8 (COPPER EARTH WIRE), Supply & Erection of 6 SWG Copper Earth Wire and making Earth connection of different Substation Items by connecting the existing Earth Pipes with necessary Lugs as directed ( As per SOR ELE, 2023-24) (7.9.3)

85

-

271.61

... More
Internal Electrification of Control Room

-

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door. ( 2.3.1 of DSR (E&M) 2018

1

-

1783.8

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63A TP&N. (2.1.2 of DSR (E&M) 2018

1

-

3139.11

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (1.10.1 of DSR (E&M) 2018

8

-

770.01

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (1.7.1 of DSR (E&M) 2018 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

45

-

223.38

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (1.24 of DSR (E&M) 2018 a) 3 pin 5/6 A socket outlet

3

-

119.21

... More
b) 6 pin 15/16 A socket outlet

3

-

187.94

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (1.25 of DSR (E&M) 2018

1

-

367.29

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required. (1.34 of DSR (E&M) 2018

3

-

125.65

... More
CFL Bulb (Bajaj/Philips/Equivalent ISI approved (i)15 Watt (As Per SOR ELE 2023-24, Specification of item Group-B of 2023-24 Supply of internal wiring & iilumination items, 38)

3

-

606

... More
Ceiling Fan of Orient/Equivalent make (ii) 1400 mm (As Per SOR ELE 2023-24, Specification of item Group-B of 2023-24 Supply of internal wiring & iilumination items, 52)

2

-

3939

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. ( 1.44 of DSR (E&M) 2018

2

-

183.64



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.