Guwahati Metropolitan Development Authority Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Guwahati Metropolitan Development Authority - GMDA Tender
Civil And Construction
Building Construction
Eprocure
Opening Date27 Feb 2023
Closing Date20 Mar 2023
Tender Amount₹ 22,58,61,395
Costs
EMD
₹ 45,17,228Document Cost
₹ 45,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_GMDA_29546_1Bid Award Id
ViewTender No
GMDA/DEV/134/2022/42Tender Authority
Guwahati Metropolitan Development Authority ViewPurchaser Address
-Website
http://https://gmda.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply and installation of polyester needle punched non woven geotextile as filter media behind Gabion/Reinforced soil wall, behind gabion fascia , as per MoRTH 700 Type-III geotextile. The width of geotextile roll shall not be less than 4.5 m, at easily accessible location including top and bottom, with all leads and lifts, manpower and machinery, materials, labour etc. complete and as directed by Engineer - In - Charge.
7445
-
-
... More
Supplying and laying drainage composite for use behind walls, between two different fills etc. having three dimensional composite with thermobonding a draining core having “N” configuration in extruded monofilaments of minimum thickness 8mm, with two filtering UV stabilized polypropylene nonwoven geotextile of minimum thickness of 0.75mm charactersitic opening size (O90) of 150 micron and tensile strength of 8.0 kN/m that will be working as separation or protecting layer, Geocomposite having in plane flow capacity of 2.1 L / (m.s) at hydraulic gradient of 1.0 & 20 kPa pressure and tensile strength of 28 kN/m, with mass per unit area of 1400 gsm, having minimum creep reduction factor of 1.15 for 100 years life at 100 kPa, at easily accessible location including top and bottom, with all leads and lifts, manpower and machinery, materials, labour etc. complete as per detailed technical specifications and as directed by Engineer - In - Charge.
10080
-
-
... More
Supply and installation of polyester needle punched non woven geotextile as filter and wrapped around PVC pipe, as per MoRTH 700 Type-III geotextile. The width of geotextile roll shall not be less than 4.5 m, at easily accessible location including top and bottom, with all leads and lifts, manpower and machinery, materials, labour etc. complete and as directed by Engineer - In - Charge.
563
-
-
... More
Supply and installation of 0.3 m thick Gabion mattress made of mechanically woven, double twisted, hexagonal shaped steel wire mesh, Mesh type 6X8 as per IS 16014:2018, Mesh wire dia 2.2 / 3.2 mm (ID/OD ), Zinc+10% Al Alloy+Polymer class A coated, Mechanically edged/selvedged, with partition at 1 m interval , tying with lacing wire of diameter 2.2/3.2 mm (ID/OD), placing at indicated places in dry condition at easily accessible location as per direction of Engineer including tools, plant, labour etc. complete in all respect (inclusive of supply and filling of stones), carrying the material from nearest approach with all leads & lifts, manpower & machinery, materials, labor etc. complete as per detailed technical specifications and as directed by Engineer-In-Charge.
639
-
-
... More
Supply and installation of 0.17 m thick Gabion mattress made of mechanically woven, double twisted, hexagonal shaped steel wire mesh, Mesh type 6X8 as per IS 16014:2018, Mesh wire dia 2.2 / 3.2 mm (ID/OD ), Zinc+10% Al Alloy+Polymer class A coated, Mechanically edged/selvedged, with partition at 1 m interval , tying with lacing wire of diameter 2.2/3.2 mm (ID/OD), placing at indicated places in dry condition at easily accessible location as per direction of Engineer including tools, plant, labour etc. complete in all respect (inclusive of supply and filling of stones), carrying the material from nearest approach with all leads & lifts, manpower & machinery, materials, labor etc. complete as per detailed technical specifications and as directed by Engineer-In-Charge.
15378
-
-
... More
Supply and installation of polyester needle punched non woven geotextile as filter media below gabion mattress, as per MoRTH 700 Type-I geotextile. The width of geotextile roll shall not be less than 4.5 m, at easily accessible location including top and bottom, with all leads and lifts, manpower and machinery, materials, labour etc. complete and as directed by Engineer - In - Charge.
6645
-
-
... More
Supply and installation of boulders of 150 mm to 250 mm tying with lacing wires, placing of geotextile at the back side etc. as directed by engineer in charge.
11130
-
-
... More
Backfilling along with structural fill behind the Reinforced Soil wall with local good quality soil/aggregates as per approved drawings and directed by engineer in charge
7680
-
-
... More
Backfilling along with structural fill behind the Reinforced Soil wall with local good quality soil/aggregates adopted from excavated soil from site as per approved drawings and directed by engineer in charge
5120
-
-
... More
Supplying and laying virgin 100% PP Staple fibre Non woven Geobags filled with locally available sand (inital Lead of 50m) having minimum mass of 400 GSM and Tensile strength of 22/24 KN/M in MD/CD and elongation of 60/60 %. The specified Geotextile (Bags) shall have puncture resistance of 4100 N and abrasion resistance of greater than 75% of strength & thickness, to be laid as per drawing in required line, level, slope as per drawing, section in tidal condition as directed by Engineer -in - Charge. (Size of Bag 1.00 x 0.70m with inflated thickness of 10cm at Centre weight of each filled bag shall be in between 130 to 150 kilogram)
89449
-
-
... More
Supply & installation of 9 mm dia Rope Gabion of size 2X1X1 m having rope weight of 42 gm/m & mesh opening 150 X150 mm with tensile strength of 1560 kg.
7454
-
-
... More
Filling of Geobag with sand as per approved drawings and directed by engineer in charge.
7871
-
-
... More
Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2018,MORTH Clause 2500, of required size, Mesh Type 10x12(D=100 mm with tolerance of ±2%), Zinc+10% Al alloy+PVC coated, Mesh wire diameter 2.7/3.7mm (ID/OD), mechanically edged/ selvedged with partitions at every 1m interval and shall have minimum 16 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2mm(ID/OD), supplied @3% by weight of Gabion boxes, as per drawing, all complete as per directions of Engineer-incharge. (Excluding boulder)
2592
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level , 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
768
-
-
... More
Excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.DSR 2021 (2.6)
15365
-
-
... More
Driveway, parking with Car shed, remaining part of retaining wall and granite finished on casecade area around pond
-
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
All kinds of soil
1620
-
-
... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
2700
-
-
... More
Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table (300-2) (a), ( Including cost of testing of materials at site and laboratory as directed by the deptt.)
810
-
-
... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, grader on prepared surface and compacting with vibratory power rollerspreading in uniform layers of specified thickness with motorto achieve the desired density, complete as per specifications anddirections of Engineer-in-Charge 16.78.3 With material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20
675
-
-
... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
675
-
-
... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
2700
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
2.6.1 - All kinds of soil
664.32
-
-
... More
Brick on edge flooring (soling) with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks:
11.1.2- 1:6 (1cement : 6 coarse sand)
186.08
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
4.1.5 - 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
17.07
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
5.9.1- Foundations, footings, bases of columns, etc. for mass concrete
111.6
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
5.9.2- Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
721.2
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
5.9.3- Suspended floors, roofs, landings, balconies and access
platform
328.5
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
5.9.16- Edges of slabs and breaks in floors and walls
5.9.16.2- Above 20 cm wide
270
-
-
... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength;including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-incharge
5.33.1 - All works upto plinth level
5.33.1.1 Concrete of M25 grade with minimum cement
content of 330 kg /cum
104.03
-
-
... More
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to
improve durability and workability without impairing strength;including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-incharge
5.33.2- All works above plinth level upto floor V level
5.33.2.1 Concrete of M25 grade with minimum cement
content of 330 kg /cum
138.51
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at plinth level.
5.22A.6- Thermo-Mechanically Treated bars of grade Fe-500D or more
48238.39
-
-
... More
Brick on edge flooring (soling) with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks:
11.1.2- 1:6 (1cement : 6 coarse sand)
1270
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
103.5
-
-
... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 30 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1cement : 4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
11.55.1 - Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
1997
-
-
... More
Staff accomodation block
-
-
-
... More
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms,lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m., All kinds of soil
158.28
-
-
... More
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials
120
-
-
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
60
-
-
... More
Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
86
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :, 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
21
-
-
... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
20
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level , 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
52
-
-
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :, 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
21
-
-
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
85
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
75
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for, Lintels, beams, plinth beams, girders, bressumers and cantilevers.
320
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for, Columns, Pillars, Piers, Abutments, Posts and Struts
280
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for, Stairs, (excluding landings) except spiral-staircases
50
-
-
... More
Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
10
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for, Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
650
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.& above, Thermo-Mechanically Treated bars of grade Fe-500D or more.
18000
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in foundation and plinth in:, Cement mortar 1:4 (1 cement : 4 coarse sand)
12
-
-
... More
Brick work 7 cm thick with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1 cement : 3 coarse sand) in superstructure above plinth level and upto floor five level.
980
-
-
... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
250
-
-
... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately)., Second class teak wood
2.5
-
-
... More
12 mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade -1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade -1, Type II marked : with necessary screws
15
-
-
... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
789
-
-
... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer., M.S. tube
895
-
-
... More
Providing and laying matt finished vitrified tile of size 100x100x16mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in out door floors such as footpath, court yard multi models etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as direction of Engineer-in-Charge
40
-
-
... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily
Glazed vitrified floor tiles polished finish of size
Size of tile 600X600 mm
419
-
-
... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
15
-
-
... More
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:
With common burnt clay F.P.S.(non modular) brick tile of class designation 10
120
-
-
... More
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
12
-
-
... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
35
-
-
... More
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 11.6.1 18 mm thic
88
-
-
... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.,Glazed Vitrified tiles Matt/Antiskid finish of size, Size of Tile 600 x 600
78
-
-
... More
CEMENT PLASTER (IN COARSE SAND), 12 mm cement plaster of mix :, 1:4 (1 cement: 4 coarse sand)
1689
-
-
... More
CEMENT PLASTER (IN COARSE SAND), 15 mm cement plaster on rough side of single or half brick wall of mix:, 1:4 (1 cement: 4 coarse sand)
1031
-
-
... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :, Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
2720
-
-
... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :, Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
82
-
-
... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :, Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
275
-
-
... More
Applying priming coat:, With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
82
-
-
... More
Applying priming coat:, With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat)
275
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
2720
-
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
307
-
-
... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
81
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight notless than 12.50 kg/sqm)
75
-
-
... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :
Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:
With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
75
-
-
... More
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
75
-
-
... More
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete., a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
150
-
-
... More
Septic Tank
-
-
-
... More
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms,lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m., All kinds of soil
19.89
-
-
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
6.93
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level , 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
8.41
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
4.67
-
-
... More
Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
43.2
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for, Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
11.59
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.& above, Thermo-Mechanically Treated bars of grade Fe-500D or more.
585.3
-
-
... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :, Cement mortar 1:6 (1 cement : 6 coarse sand)
2.76
-
-
... More
12 mm cement plaster of mixed with floating coat of neat cement slurry.13.7.1. 1:4 (1 cement: 4 coarse sand)
40.8
-
-
... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. thanThe material shall meet the requirements as specified in ACI212-3R-2010 i.e by reducing permeability of concrete by more 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydr ostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage., For horizontal surface one coat @1.10 kg per sqm.
21
-
-
... More
For vertical surface two coats @ 0.70 kg per sqm
36
-
-
... More
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements