Guwahati Metropolitan Development Authority Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Guwahati Metropolitan Development Authority - GMDA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date2 Mar 2024
Closing Date21 Mar 2024
Tender Amount₹ 15,84,81,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge. Note:- The inclusion of the above item in the schedule of work shall be judiciously decided by the technical sanctioning authority, keeping in view the quality control, Type of soil strata and importance of the project.

5

-

-

... More
Steel reinforcement for R.C.C. work ncluding straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. ( For Pile Work )

21721

-

-

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

12.21

-

-

... More
Empty Boring

329

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil

3238.94

-

-

... More
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil

2459.08

-

-

... More
Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered): Depth exceeding 3 m but not exceeding 4.5 m

495.69

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

1661.2

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand(zone-III) : 8 graded stone aggregate 40 mm nominal size).

60.31

-

-

... More
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

930.39

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).

-

-

-

... More
All works upto plinth level

559.71

-

-

... More
All works above plinth level upto floor V level

1296.54

-

-

... More
Centering & shuttering including strutting, propping etc. and removal of form work for:

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

171.72

-

-

... More
Walls (any thickness) including attached pilasters, butteresses plinth and string courses etc.

1671.11

-

-

... More
Suspended floors, roofs, landings, balconies and access platform

3963.86

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

4555.41

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

1503.77

-

-

... More
Stairs, (excluding landings) except spiral-staircases

284.22

-

-

... More
Steel reinforcement for R.C.C. work ncluding straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more

149679.6

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

224519.4

-

-

... More
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.

-

-

-

... More
For vertical surface two coats @ 0.70 kg per sqm

495.69

-

-

... More
For horizontal surface one coat @1.10 kg per sqm.

519.91

-

-

... More
ARCHITECTURAL WORKS:

-

-

-

... More
Earth work in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil All kinds of soil For UG TANK, DRAIN, FRONT BOUNDARY

783.22

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in wateriing, lead upto to 50m and lift upto 1.5m

117.48

-

-

... More
Supplying and filling in plinth with sand under floors including, watering, ramming consolidating and dressing complete.(SAND FILLING FOR DRIVEWAY PARKING)

54

-

-

... More
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.

996.74

-

-

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground leveland removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.

996.74

-

-

... More
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20%

180

-

-

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion): Along external wall where the apron is not provided using chemical emulsion @ 7.5 liters / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.

80

-

-

... More
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration

80

-

-

... More
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) FOR UG TANKS, DRAIN, BOUNDARY WALL

103.52

-

-

... More
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone -III) : 4 graded stone aggregate 12.5 mm nominal size)

16.88

-

-

... More
Applying a coat of residual petroleum bitumen of penetration VG 10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

16.88

-

-

... More
Making plinth protection 75mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.

46.5

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : BOUNDARY WALL 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).

23.86

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.

-

-

-

... More
All work upto plinth level FOR UG TANKS

85.5

-

-

... More
All work plinth level upto roof level FOR BUILDING(LINTELS)

37.68

-

-

... More
Centring and shuttering including strutting, propping etc. and removal of form for:removal of form for: Foundations,footings,bases of columns including beams etc. for mass concrete FOR UG TANKS

104.8

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

480

-

-

... More
Suspended floors, roofs, landings, balconies and access platform

72

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

251.21

-

-

... More
Columns, pillars, piers, abutments, posts and struts

56

-

-

... More
Steel Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe 500 D or more

2147.4

-

-

... More
Steel Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe 500 D or more

11086.27

-

-

... More
Brick work with common burnt clay FPS (Non-modular) bricks of class designation 75 in Super structure above plinth upto floor V level in all shapes and sizes in: Cement mortar 1:4 (1 cement : 4 coarse sand)

65.6

-

-

... More
Half-Brick Masonry with common burnt clay FPS (Non-Modular) bricks of Class Designation 7.5 in Superstructure above plinth upto floor V level Cement mortar 1:4 (1 cement : 4 coarse sand)

191.64

-

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in- Charge. (The payment of RCC band and reinforcement shall be made for seperately).

317.46

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of Slab over 0.50 sqm

110.07

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work

1385.5

-

-

... More
Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform, vanity counters and similar location in marble/stone work including necessary holes for pillar taps etc .including rubbing and polishing of cut edges etc. complete.

2

-

-

... More
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade

6.3

-

-

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

397.98

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

61

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 'Sal Wood

1.26

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.

137.34

-

-

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured)

137.34

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding

100

-

-

... More
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x 10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand: 6 graded stone aggregate 20mm nominal size).

260

-

-

... More
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm

130

-

-

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete

65

-

-

... More
Providing and fixing bright finished brass handles with screws etc. complete:

65

-

-

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

18

-

-

... More
Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for separately).

46.8

-

-

... More
Providing and fixing 50mm thk glazaed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (PartII), tested and certified as per laboratory approved by Enginner inCharge , with suitable mounting on door frame, cosisting of verticle styles, lock rail, top rail, 100mm wide, bottom rail 200mm wide, made out os 16 SWG G I Sheet(zinc coating not less than 120gm.m2) duly filled FR Insuation material and fixing with necessary stainless steel ball bearing hinges of approved make , including applying a coat of approved fire resistant Primer etc. all complete as per direction of Engineer in Charge(panelling to be paind for seperately)

18.9

-

-

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels, ventilators and partitions etc., with G.I. beading of appropriate size, made out of 20 SWG G.I.sheet (zinc coating not less than 120 gm/m2), fire resistant sealant, including applying a coat of approved fire resistant primer on G.I. beading etc., complete all as per direction of Engineer-incharge. 'With clear fire resistant glass panes 6mm thick of approved brand, having minimum 60 minutes fire resistance

6.75

-

-

... More
Structural steel work in single section fixed without connecting plate including cutting hoisting, fixing in position & applying priming coat of approved steel primer all complete.(FOR SUPPORT FRAME OF CURTAIN WALL)

8742.38

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80 x 1.25 mm M.S. laths with 1.25 mm thick top cover

9

-

-

... More
Providing and fixing ball bearing for rolling shutters.

18

-

-

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 10.00 sqm and upto 16.80 sqm in the area

9

-

-

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mm dia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing.

100

-

-

... More
Steel work welded in built-up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladders, balcony and staircase railings, brackets, gates and similar works

1000

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).

2592

-

-

... More
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

424

-

-

... More
Cement plaster skirting (upto 30cm height) with cement morter 1:3 (1 cement 3 coarse sand) finished with a floating coat of neat cement. 18mm thick

125.6

-

-

... More
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.1.1 Acid and alkali resistant tile.

170.42

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick

47.24

-

-

... More
Providing and fixing Ist quallity Ceramic Glazed Wall Tiles conforming to IS: 15622 (thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

530.12

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 1000x1000mm OR 600MM X 1200MM

2137.97

-

-

... More
Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm,comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I.Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized ofrectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be corrosion resistant epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and, an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 450 mm Finished Floor Height (FFH).

25

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

5

-

-

... More
12mm cement plaster of mix: 1:4( 1 cement : 4 fine sand)

3734.84

-

-

... More
15mm cement plaster of mix: 1:6 ( 1 cement : 4 fine sand)

1144.98

-

-

... More
6mm cement plaster to ceiling of mix: 1:3 (1 cement : 3 fine sand)

6748.1

-

-

... More
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.

1144.98

-

-

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

1144.98

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

1

-

-

... More
Varnishing with varnish of approved brand and manufacture : Two or more coats glue sizing with spar varnish or an under coat of flatting varnish

275.94

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

11627.92

-

-

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50grams / litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats

10482.94

-

-

... More
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .

162

-

-

... More
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.(DRIVEWAY)

81

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as perdirection of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

1.5

-

-

... More
Providing and laying matt finished vitrified tile of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.(GROUND FLOOR STILT PARKING+DRIVEWAY+BASEMENT)

1536

-

-

... More
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.RAMP

4

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For Fixed Portion

-

-

-

... More
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

66.83

-

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

58.73

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4 mm thickness

10.26

-

-

... More
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width

78.3

-

-

... More
Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately).(FOR LOUVRES/SCREEN)

2137.5

-

-

... More
Providing and mixing integral crystalline admixture for waterproofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck, using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (CONSIDERING 1%)

299.25

-

-

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm).(BASEMENT)

952

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

700.54

-

-

... More
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)

85

-

-

... More
Providing and laying APP (Atactic Polypropylene Polymer) modified pre fabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3mm thick

425

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: A) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: B) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. C) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. D) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. E) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 1500pa) as perASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

1112.02

-

-

... More
Providing and Supplying aluminum extruded tubular and other sections as per the architecturl drawings and approved shop drawings, the aluminum quality as per grade 6063 T5 or T6 as per BIS 1474, including super durable powder coating of 60-80 micron conforming to AAMA-2604 of required color and shade as approved by the engineer in charge (The item included cost of material like cleats, sleeves, screws etc necessary for fabrication of extruded Aluminum frame work. Nothing extra shall be paid on this account)

3438.67

-

-

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface #2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

1091.85

-

-

... More
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.

1

-

-

... More
Providing and supplying Spandrel Glass Panels comprising of 6mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge.“For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20%, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

20.17

-

-

... More
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so asto make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

48

-

-

... More
Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of 350 kPa listed as per ASTM D 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorption 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the directions of Engineer-in-Charge.

435

-

-

... More
Providing and fixing factory made Kitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardent having necessary screw holding capacity. Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge.

13.83

-

-

... More
Providing, erecting, maintaining and removing temporary protective screens made out of specified fabric with all necessary fixing arrangement to ensure that it remains in position for the work duration as required by the Engineer-in-charge. Wooven PVC Cloth

2830

-

-

... More
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineerin-Charge. (The payment shall be made on the basis of actual weight of approved grout injected.)

-

-

-

... More
Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work

750

-

-

... More
Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/ RCC work.

750

-

-

... More
Epoxy injection grout in concrete/RCC work of approved make

1000

-

-

... More
Providing And Fixing Grid Connected Solar PV Module including supply and installation complete Solar PV Module as per the size of the plant Solar Grid connected inverter as per the size of the plant Solar PV Module mounting structures Cables for interconnection of the solar modules Cable for connecting solar module with inverter Lighting arrestors and earthing kit Installation and commissioning

50

-

-

... More
Providing, transporting to site, laying , fitting & fixing of Cement Concrete Interlocking Grass Pavers Blocks having a minimum thickness of 60 mm coloured, factory made in rubber moulds by Vibro Compaction Technique having compressive strength of not less than 350 kg/cm2 & size of 400 mm x 400 mm with 4 nos of open square voids having 80% perforation for water percolation and growth of grass in it , laid on a 5” deep bed of compacted original soil and 3 “ compacted gravel stones and 1’’ Layer of sand on top of the gravel bed made suitable for landscaping and external surfacing , duly smoothened finished and levelled to install the Interlocking Grass Pavers Blocks. Interlocking Grass Pavers has perpendicular ties after release from the mould and the same is retained after laying. GRASS PAVER 60MM

200

-

-

... More
Providing & fixing Sturdo Classique Evergreen Toilet Cubicle (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12mm thick solid compact laminate panels tested by Shriram Test House. Finish of the compact laminate should be Suede / *Raw silk, which includs doors, pilasters & intermediate panels finished with approved texture/shade as per the detail drawings & as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. The product should have Green Guard Certificate. This also includes providing and fixing in position necessary hardware made out of Stainless steel (Grade 304) as per manufacturer’s specifications & Architects instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset with Occupancy indicators, (4) Coat hooks with Door stopper (5) U-Channels, (6) Adjustable foot/pedestal, (7) Top rail with Corner conntector (8) Rubber noise deafening tape, (9) Screws & wall Plugs. The top fitting should consist of SS round top rail which will get fixed with pilasters, with SS panel tube holder, SS corner bend (connected with top rail) will be used on the corner of cubicle in absence of brick wall, SS wall fixing is used only on the wall which will hold the ss top rail. All screws will of 304 Grade in stainless steel with satin finish. All pilasters are supported by stainless steel Bottom Cladding. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 150mm. Toilet Cubicle with standard dimension of 2025mm Height x 1000mm Width x 1550mm Depth, which includes 600mm door size width). Toilet Cubicle I-Shape (Front Partition) with standard dimension of 2025mm Height x 1000mm Width which includes 600mm door size width). All aspects specified by the manufactures, Greenlam Sturdo Classique Evergreen Model or equivalent.

13

-

-

... More
19mm Thick Microcellular Closed Cell Nitrile Rubber Insulation having Moisture Resistance Factor 7000. Fire Performance BS476 Part 6 Class “O”. Nominal Density 40 – 60 kg / m3

1

-

-

... More
Professional modular Galvanised and painted barrier, complete with control panel and fitted to take additional accessories. Road barrier with 230V A.C. operator, Modular design, weatherproof and meant for heavy duty. IP-54 rated, Torque-600nm, Intensive use, LED luminous strip on the entire length of the boom on both sides, Make: CAME- Italy or Equivalant Automatic boom Barrier with swing away Arm/boom with following requirement / features- 1. Barrier Boom Length : 7.6 m 2. 2. Height of the boom from ground : 914 +or – 50 mm 3. Opening & Closing Time : 4 to 8 Sec. / Housing: The control unit shall be housed in weather proof housing on top of the cabinet with atleast IP 54 Protection for easy maintenance and saving from water Logging./ Operation: Stand alone with push Button switch and also shall be integrated with Access Including:Operating Manual key Switch for the barriers Support bar Photocell Heavy duty professional Access Controller with 30,000 user capacity Make: Rosslare Security Long Range UHF Reader (In & Out) Make: Rosslare UHF Lables 2 KVA Power stablizer Including Installation

1

-

-

... More
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (a) Within Guwahati city only

539.8

-

-

... More
Providing sprayable Fire-rated joint spray Hilti CF= SP WB to seal gap between horizontal slab & curtain wall to provide m=nimum 2 hours of fire rating when tested as per ASTM E 2307 standard . The product to have upto 50% Movement Capability and Sou=d Insulation of 55db as per ASTME-90. The product shall have passed the 50= cycles requirement as specified by ASTM E 1399 class II. The product shal= carry carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96 and shall have a =OC content of approx. 60 g/l as per LEED 2009. The product shall carry tes= certificate as per ASTM E 1399 class II for movement capability. The syst=m shall be UL listed & Classified and product shall bear the UL and FM approval logo on the packing. If none=of UL test certificate comply with actual application, an EJ document prep=red by a qualified personnel and based on nearest third party tested &=approved systems like UL test certificates & in accordance with IFC guidelines shall be produced by manufacturer.=A firestop submittal shall be produced by manufacturer , in accordance wit= approved passive fire protection method statement, for technical approval= Firestop installation shall be done by Hilti Accredited Firestop Specialty Contractor (HAFSC) and in accordanc= with Hilti guidelines and UL system test certificates or approved EJ docu=ent. Firestop Specialty Contractor needs to submit work completion certifi=ate along with installation report through Hilti documentation Software CFS DM for periodic inspection & =aintenance purpose.

69.04

-

-

... More
Providing zinc cladding of 0.8MM thickness in exterior façade of building of Flat Lock Panel Type Panels Factory made abd with necessary Ventilated Fixing subframe with aluninum Section as per Vendor specs and as directed by E in C

296.5

-

-

... More
Providing and Installing List 10 Passenger Capacity With Automatic Centre Opening Door having 9 Stops and complete incuding approval and commissioning License. Body in Stainless Steel Scrtach resistannt Finish . Automatic Rescuse Device and Display in LED . Machine room less type Model of approved make - Kone, Shindler, Thyssen Krup

2

-

-

... More
FIRE FIGHTING PUMPS & EQUIPMENTS

-

-

-

... More
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (a) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (b) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (c) Suitable cement concrete foundation duly plastered with anti vibration pads. (d) The pump shall be of the following specifications: 2280 lpm at 88 m Head Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.

2

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. The pump shall be of the following specifications: 2280 lpm at 88 m Head Note: * The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.

1

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. The pump shall be of the following specifications: 180 lpm at 88 m Head

2

-

-

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Incoming: 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A Outgoing: ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey pump 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Diesel Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.

1

-

-

... More
Providing, laying, jointing, testing, & commissioning the PVC insulated & sheathed FRLS (Flame Retardant Low Smoke) Armoured Cables of 1.1 K.V. Aluminium Conductor including supplying and making end termination with brass compression glands:

-

-

-

... More
3 core x 10 sq.mm

50

-

-

... More
3 core x 220 sq.mm

50

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

2

-

-

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

5

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
25 mm dia

5

-

-

... More
65 mm dia

25

-

-

... More
80 mm dia

30

-

-

... More
100 mm dia

50

-

-

... More
150 mm dia

75

-

-

... More
200 mm dia (wall thickness 6.3 mm)

30

-

-

... More
250 mm dia (wall thickness 6.3 mm)

25

-

-

... More
Providing, fixing, testing and commissioning fire retardent / extinguishing electrical insulated synthetic mat of 3mm thick ±10% conforming to latest BIS doc no.-ET-02(5440) meeting requirements of IS 3043 / IS 5216 (Part I, II & III), IS 8437 & IEC 479 suitable for all voltages not exceeding 3.3 KV AC supply and having minimum width of 1000mm ± 20mm and including supply of required quantity of adhsive / compound and fixing the same at site as per site requirement.

2.5

-

-

... More
Providing, fixing, testing and commissioning following size of perforated M.S. Cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders including painting, etc., as required. 150mm width x 50mm depth x 1.6 mm thickness.

40

-

-

... More
Providing, fixing, testing and commissioning dial type Pressure Gauge with isolation cock and copper pipe on main header Dial diameter 100 mm celebration 0-15 / sq. cm.

10

-

-

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :

-

-

-

... More
65 mm dia

2

-

-

... More
80 mm dia

2

-

-

... More
100 mm dia

2

-

-

... More
150 mm dia

5

-

-

... More
200 mm dia

5

-

-

... More
250 mm dia

2

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :

-

-

-

... More
65 mm dia

2

-

-

... More
150 mm dia

3

-

-

... More
200 mm dia

2

-

-

... More
250 mm dia

1

-

-

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.

-

-

-

... More
250 mm dia

2

-

-

... More
Providing, fixing, testing and commissioning reinforced Neoprene Flexible Pipe connectors with all accessories on all pumps suction & delivery.

-

-

-

... More
Suitable for 20 Kg/cm2

-

-

-

... More
200 mm

3

-

-

... More
150 mm

3

-

-

... More
80 mm

2

-

-

... More
65 mm

2

-

-

... More
Providing, fixing, testing and commissioning of Venturi type Flow meter of approved brand of manufacture, with accessories etc., complete. 150 mm dia

1

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
25 mm dia

15

-

-

... More
80 mm dia

34

-

-

... More
100 mm dia

11

-

-

... More
150 mm dia

278

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (Under Ground Piping) 150 mm dia

20

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

11

-

-

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

4

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)

30

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

11

-

-

... More
Supplying & fixing 63 mm dia short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)

15

-

-

... More
Providing, fixing, testing and commissioning of Weather Proof standard Hose Cabinet (0.75x0.60x0.25) outdoor type fabricated from 16 gauge CRCA M.S. sheet having central opening glazed door including necessary locking arrangement, painting (one coat primer & two coats of paint) for accomodatating external hydrant valves. (The cabinet shall be prepared as per drawing). The words "Hose Cabinet" to be painted on the Box.

4

-

-

... More
Providing and fixing fire hose cabinet fabricated from 16 gauge M.S sheet with single or double glazed front door and locking arrangement, painted “Fire Hose” with stove enameled paint, written on front, including necessary supports of approximate size 2100x900x700 mm deep to house two lengths of canvas hose with couplings, branch pipe, fire hose reel, nozzle, fireman axe, single outlet landing valve and first-aid hose reel, complete in all respects.

11

-

-

... More
Supply, fixing, testing and commissioning of Pressure Guage with needle valve & pipe nipples of approved brand of manufacture, with accessories etc., complete. (Located at every hydrant at each floor ).

11

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
150 mm dia

6

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.

1

-

-

... More
Providing, fixing, testing and commissioning of GM Four Way Fire Brigade Inlet connection on external ring/pumps delivery header with Butterfly valve and non return valve complete in all respects. (Butterfly valve & Non return valve shall paid seperately). 150 mm dia

1

-

-

... More
Providing, fixing, testing and commissioning of Draw Off Connection for fire brigade withdrawal of water from tank with 100 mm dia MS (Heavy class) pipe and foot valve. (Pipe shall be paid seperately).

1

-

-

... More
Providing, fixing, testing and commissioning of gun metal Four Way connection for Tank filling (Siamese connection).

1

-

-

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

11

-

-

... More
Providing, fixing, testing and commissioning of standard Fireman's Axe with heavy insulated rubber handle.

11

-

-

... More
Providing & Laying Thrust Block in cement concrete in 1:2:4 including shuttering, centring, curing etc. complete as per standard detail.

1

-

-

... More
Providing and laying non-pressure NP3 class (Heavy duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 find sand) including testing of joints etc. complete with excavation, refilling and disposal of surplus earth wherever required complete in all respect as per specifications. (For pipes crossing roads) 250 mm dia RCC Pipe

10

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :

-

-

-

... More
25 mm dia

1025

-

-

... More
32 mm dia

72

-

-

... More
40 mm dia

198

-

-

... More
50 mm dia

189

-

-

... More
65 mm dia

148

-

-

... More
80 mm dia

103

-

-

... More
100 mm dia

29

-

-

... More
150 mm dia

121

-

-

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150 mm dia

2

-

-

... More
Supply, fixing, testing and commissioning of Pressure Guage with needle valve & pipe nipples of approved brand of manufacture, with accessories etc., complete.

10

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :

-

-

-

... More
Pendent Sprinkler (K-80)

95

-

-

... More
Upright Sprinkler (K-80)

293

-

-

... More
Horizontal side wall sprinkler (K-80)

12

-

-

... More
Concealed sprinkler (K-80)

191

-

-

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required.

-

-

-

... More
100mm dia

7

-

-

... More
80 mm dia

3

-

-

... More
Providing, fixing, testing & commissioning Air Release Valve with 25 dia air valve at the top of Risers. 25 mm dia.

2

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
50 mm dia

1

-

-

... More
80 mm dia

3

-

-

... More
100 mm dia

7

-

-

... More
150 mm dia

10

-

-

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.

-

-

-

... More
700mm

25

-

-

... More
1000mm

65

-

-

... More
1200mm

50

-

-

... More
1500mm

50

-

-

... More
Providing, fixing, testing & commissioning of gunmetal Inspecting & Testing Assembly with ball valve (3 nos.), gunmetal sight glass, bye pass valve & connected to drain line. (Cost of all valves & fittings shall be included in the rate). 25 mm dia

11

-

-

... More
Providing, fixing, testing & commissioning ABC type Fire Extinguishers consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 6.0kg. I.S.I. Marked.

25

-

-

... More
Providing, fixing, testing & commissioning Carbon-di-oxide Fire Extinguishers consisting of welded M.S cylinderical body,squeeze lever discharge valve fitted with internal dischargetube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. I.S.I. Marked.

25

-

-

... More
Providing, fixing, testing & commissioning Mechanical Foam type (ISI marked) Fire Extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cm long high pressure discharge hose, discharge nozzle suspension bracket ISI marked as per IS 933 finished externally with red enamel paint and fixed to wall with brackets complete with internal charger.

-

-

-

... More
9 litres capacity

5

-

-

... More
50 litres capacity (trolly mounted)-For DG set area

1

-

-

... More
Providing, fixing, testing & commissioning Carbon-di-Oxide Fire Extingushers trolley mounted with all accessories internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. Capacity 22.5 kg. For DG set area

1

-

-

... More
Providing, fixing, testing & commissioning of 4 Nos of Sand Bucket ISI Marked to IS:2546 capacity 10 ltrs. with stand.

1

-

-

... More
Supplying, fabricating, structural steel supports fabricated from MS channels, angles, flats including painting with one coats primer and two coats of enamel paint of an approved shade rate quoted shall include for supply and providing necessary, welding cutting, 'U' clamps bolts nuts, washers etc.as per specification of pipe supports for horizontal / vertical pipes running along wall / column, slabs trenches etc to suit different dia pipes.

2000

-

-

... More
PLUMBING WORKS

-

-

-

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres),including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

22

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer

21

-

-

... More
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

21

-

-

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore

7

-

-

... More
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

21

-

-

... More
Providing and fixing C.P. brass towel rails Jaquar Cat No. 1111 or equivalent make PARKO-Classic-1555/KINGSTON-AGR ACS 15A complete with C.P. brass brackets fixed to rawl plug of approved design with C.P. brass screws. 600 x 20 mm size

11

-

-

... More
Providing and fixing C.P. brass twin robe hooks, JAQUAR Cat. No. 1161 or equivalent make PARKO-Classic-1582/KINGSTON-AGR ACS 66.

22

-

-

... More
Providing and fixing stainless steel soap dish (Jaquar Cat. No. ACN-1131N) or equivalent make PARKO-Classic-1552/KINGSTON-AGR ACS 11 including making good the walls wherever required.

21

-

-

... More
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore

42

-

-

... More
Providing and fixing C.P. brass angle valve for basin/sink mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore

66

-

-

... More
Providing and fixing toilet paper holder : C.P. brass

22

-

-

... More
Providing and fixing S.S. hinged grating, 6mm thick with frame (Neer Cat. No. - NRG 7006 or equivalent make CHILLY-CRG-R-127 (Square Classic)/JAYNA TOPAZ Cat. No. TR 102 including setting in floor with cement mortar 1:3.

38

-

-

... More
Providing and Fixing health faucet JAQUAR Cat. No. 573 (ALLIED SERIES) or equivalent make PARKO-Allied-1597/KINGSTON-AGR ACS 49 with flexible pipe and wall hook with each European W.C. Pan.

22

-

-

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

14

-

-

... More
Providing and fixing in position Urinal partition out of size 750X500mm in 15-19mm thick jet black granite slab, polished on both sides and round moulded edge as per approval including appropriate chase making, fixing, packing and stiffening with bombay nails and plastering.

10

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm

3

-

-

... More
Providing & fixing Wall Mounted C.P. Brass Sink Mixer single hole / single lever with swinging costed spout of required size including cutting and making good the wall wherever required.

3

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
Internal work- exposed on wall

-

-

-

... More
15 mm nominal outer dia .Pipes.

5

-

-

... More
20 mm nominal outer dia .Pipes.

7

-

-

... More
25 mm nominal outer dia .Pipes.

10

-

-

... More
32 mm nominal outer dia .Pipes.

20

-

-

... More
40 mm nominal outer dia .Pipes.

46

-

-

... More
50 mm nominal outer dia .Pipes.

184

-

-

... More
Providing and fixing chlorinated poly vinyl chloride (CPVC) pipes hyaving thermal stability for hot & coldwater supply, including all CPVC plain & brass threaded fitting, including fixing the pipewith clampsat 1 m spacing. This includesjointing of pipes & fittingwith one step CPVC solvent cement and cost ofcutting chases and making good the same including testing ofjoints complete as per direction ofEngineer in Charge.

-

-

-

... More
Concealed work including cutting chases and making good the walls etc.

-

-

-

... More
15mm nominal outer dia. Pipes.

66

-

-

... More
20mm nominal outer dia. Pipes.

416

-

-

... More
25mm nominal outer dia. Pipes.

149

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.

-

-

-

... More
50 mm nominal dia Pipes

80

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)

-

-

-

... More
25 mm nominal bore.

21

-

-

... More
20 mm nominal bore.

21

-

-

... More
40 mm nominal bore.

2

-

-

... More
50 mm nominal bore.

8

-

-

... More
Providing and fixing motorised butterfly valve PN 10 suitable for 240 Volts , with suitable motorised rotor 3 nos of float type sensors and control panel , to shut and close valve when water level is low / high in water tanks including making electrical connection with nearest electrical point provided by other agency. The cost of cable / wire from butterfly valve to the electrical point as shown in the drawing to be included in the rate.

-

-

-

... More
32mm dia

2

-

-

... More
40mm dia

1

-

-

... More
Providing, fixing, Testing and Commissioning of Type A Ringfit UPVC SWR pipes for vent, soil, waste, confirming to IS 13592 and Fittings confirming IS 14735. Cost shall be inclusive of providing and fixing of all fittings (plain or door) e.g. bends, junctions, cowls, offsets, access pieces in pipes, & G.I. clamps spaced at 1.0 m center to center for wall and roof, jointing with solvent cement joints including cutting chase or making holes in walls and floors and making good as per specification and directed by Engineer In charge. ( For Rain Water & vent)

-

-

-

... More
160mm OD

145

-

-

... More
75mm OD

169

-

-

... More
Providing, fixing, Testing and Commissioning of Type B Ringfit UPVC SWR pipes for vent, soil, waste, confirming to IS 13592 and Fittings confirming IS 14735. Cost shall be inclusive of providing and fixing of all fittings (plain or door) e.g. bends, junctions, cowls, offsets, access pieces in pipes, & G.I. clamps spaced at 1.0 m center to center for wall and roof, jointing with solvent cement joints including cutting chase or making holes in walls and floors and making good as per specification and directed by Engineer In charge. ( For Rain Water) 110mm OD

554

-

-

... More
Supply, installation , testing & commissioning in position SWR PVC P trap of self cleaning design of following sizes. Making proper connection with Cutting chase / hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as per specifications. including cost of cutting and making good the walls and floors after installation of P traps wherever required. 100mm inlet and 100 mm outlet

36

-

-

... More
Supply, installation , testing & commissioning PVC saddle for connecting two or three inlet waste connection of 32/40 and 50mm nominal dia , including cutting and chasing as per approved specifications

8

-

-

... More
Supply, installation , testing & commissioning 100mm x 63 mm PVC waste reducing elbow including cutting chases, making holes in the floor / slab, restoring the same after installation complete as per approved specifications and connection to pvc pipes

8

-

-

... More
Supply, installation , testing & commissioning upvc floor/ceiling clean out plug with suitable inlet key for opening male threaded joint with UPVC pipe & socket. Including socketed joint complete as per approved specifications. For 110 mm dia pipe

22

-

-

... More
Supplying, installation , testing & commissioning of uPVC pipes and fittings ( For Internal drainage & roof drainage) confirming to IS 4985 for drain in wall / floor / open, pressure rating 6 kg/cm2 tested to IS 2556 (XIII), seals to traps as per IS 5329, including all accessories, breaking / chasing walls, making necessary holes in floor, walls etc. as per approved specifications and making good etc., Cement mortar encasing under floor within toilets.

-

-

-

... More
40 mm dia OD waste pipe.

50

-

-

... More
50 mm dia OD waste pipe.

17

-

-

... More
63 mm dia OD waste pipe.

22

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

4

-

-

... More
Providing and fixing cast iron gratings for Rain Water Pipes. 225x225mm

4

-

-

... More
Providing & Fixing uPVC water pipes (IS:4985-2000) of 10Kg/cm2 including all fittings e.g bends, junctions, elbow,F-tee, M-tee, offsets, access pieces etc. jointing with solvent cement including cutting holes in walls & making good, complete in all respects. 90 OD for basement sump pump riser

80

-

-

... More
Making Drainage point in upper basement slab to be left in lower basement for upper basement drainage. The point shall have drain point in floor with grating connected with 150 mm dia uPVC type-A pipe with all necessary supports. The cutout shall be filled with sealant to make it leakfree.

10

-

-

... More
Providing and fixing square-mouth uPVC gully trap complete with grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 150X150 mm Gully Trap

3

-

-

... More
Providing, laying and jointing of UPVC drainage pipe confirming to IS 15328 - 2000 with all fittings such as bends, tees, elbow. The wall thickness of pipe and technical charactersticks confirms to IS 15328 - 2000 type SN 8. The fittings dimentions confirming to BS : EN 140121998. The jointing to be completed with rubber ring / solvent weld joint complete.

-

-

-

... More
160 mm dia

15

-

-

... More
200 mm dia

50

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand 10 graded stone aggregate 20 mm nominal size) 100 mm thick all-round SN 8 pipe at joints only including bed concrete at entire length of 150 mm thick as per standard design.

-

-

-

... More
160 mm dia

15

-

-

... More
200 mm dia

50

-

-

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :

-

-

-

... More
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

5

-

-

... More
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

10

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil

2

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

1

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

65

-

-

... More
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.

5

-

-

... More
Providing, laying and jointing of UPVC drainage pipe confirming to IS 15328 - 2000 with all fittings such as bends, tees, elbow. The wall thickness of pipe and technical charactersticks confirms to IS 15328 - 2000 type SN 8. The fittings dimentions confirming to BS : EN 140121998. The jointing to be completed with rubber ring / solvent weld joint complete.

-

-

-

... More
160 mm dia

30

-

-

... More
200 mm dia.

50

-

-

... More
250 mm dia

40

-

-

... More
300 mm dia

20

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand 10 graded stone aggregate 20 mm nominal size) 100 mm thick all-round SN 8 pipe at joints only including bed concrete at entire length of 150 mm thick as per standard design.

-

-

-

... More
160 mm dia

30

-

-

... More
200 mm dia.

50

-

-

... More
250 mm dia

40

-

-

... More
300 mm dia

20

-

-

... More
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :

-

-

-

... More
0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil

2

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

1

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

140

-

-

... More
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre). Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.

1

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

4

-

-

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

8

-

-

... More
Extra for depth beyond 45 cm of brick masonry chamber : For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
Construction of rain water harvesting pit, size 3.0 m x 3.0 m x 3.0m effective depth for re-charging of storm water run off including the civil work including excavation with following items.

1

-

-

... More
Providing and constructing masonry de-silting chamber 1200mm x 1500 mm with required depth inside with class-I designated brick work in cement mortar 1:6 (1cement : 6 coarse sand) with C.I double seal medium duty 560mm dia manhole cover (1Nos.). top slab 150 mm thick 1:2:4 mix (1cement : 2coarse sand : 4 graded stone aggregate 20mm nominal size) with minimum 1.5% reinforcement, 150mm thick foundation concrete 1:5:10 (1cement : 5 coarse sand:10 grade stone aggregate 20mm nominal size , necessary excavation, back filling and disposal of surface earth. Complete with inlet, outlet and overflow arrangement. Foot rest @400mm c/c, grating of required size with 16mm sq.bars and frame @ 20mm clear spacing fixed at mouth of pipe as per site conditions and direction of Project Manager.

1

-

-

... More
Drilling percolation borehole 200mm dia with reverse rotary method in all types of soil 1 bores per pit of depth 15m (approx.) including cost for mobilization of rig and making good the area upon completion of work. Contractor shall arrange for all necessary tools, water and consumable and laying for drilling.

1

-

-

... More
Providing and laying pea gravel all around the casing pipe.

1

-

-

... More
Providing and laying of 160 mm dia slotted uPVC pipe of 6 Kg/cm2 - 35 m - 40m per bore or as per site sub-strata or set as per direction of Project Manager. (Proposed 1 bore per pit)

1

-

-

... More
Providing and laying of 160 mm dia uPVC blind pipe of 6 Kg/cm2. - 10m per bore. (Proposed 1 bore per pit)

1

-

-

... More
Supply, Installation, testing and commissioning of drinking water coolers: Storage Capacity 150 Liters, No of Faucets 2, Nominal Cooling Capacity 150L/hr, Faster cooling, Silent operation, Nationwide service, Stainless Steel body, Stainless Steel tank, Easy controls, Speedy drainage with drain board complete set, The Compressors shall be having 5 years replacement warranty.

1

-

-

... More
Supply, Installation, testing and commissioning of drinking water coolers: Storage Capacity 50 Liters, No of Faucets 2, Nominal Cooling Capacity 50L/hr, Faster cooling, Silent operation, Nationwide service, Stainless Steel body, Stainless Steel tank, Easy controls, Speedy drainage with drain board complete set The Compressors shall be having 5 years replacement warranty.

7

-

-

... More
Design,engineering, supplying & installation of water treatment plant comprising of filter feed pumps, sand filter, dual media filter, chlorine dosing, necessary piping and valves, electrical cables, cable trays, panels to provide a packaged unit to treat water and store it in domestic water tanks located in basement. The vendor to submit design basis and calculations with technical data sheets to consultants for review. Capacity- 4 m3/day

1

-

-

... More
Design, supplying, installing, testing & commissioning of packaged Sewage Treatment Plant of capacity 7 m3/day Excluding excavation, back filling & disposal of surplus earth /Civil construction work for the following duty: Nature of effluent - Domestic Sewage from toilets, pantry waste water. Anticipated influent parameters before treatment:-Range PH:7.5 - 8.5 BOD:250-400 mg/ltr TSS :200-450 mg/ltr COD-600-800 mg/ltr Oil & Grease- Up to 100 mg/ltr Desired Sewage discharge standard after ACF/UF are as below: PH :5.5-9 BOD 5 : Less than 10 mg/l S. solids : Less than 20 mg/l COD : Less than 50 mg/l Oil & grease : 10 mg/L N- total : 10 PPM Coliform : 100 count/100ml The vendor to submit design basis and calculations with technical data sheets to consultants for review.

1

-

-

... More
Supply, Installation,Testing and commessioning of following equipment with accessories complete as requires Horizontal Centrifugal water supply pumps (suitable for positive suction) consisting of the following: 2 Nos. pumps (1 Working + 1 Standby) each pump shall have S.S 304 impeller, S.S. 304 shaft fitted with mechanical seal, C.I. connections, directly coupled with totally enclosed fan cooled [TEFC] induction motor 2900 RPM mounted over M.S fabricated base plate complete, including suitable vibration eleminations pads, pressure gauge with gun metal isolation cock. Each pump shall be suitable for automatic/manual operation. Each pump shall be suitable for 415 ± 10% volts, 3 phase, 50 Hz A.C supply & shall be having the following requirement:

-

-

-

... More
Flow rate: 1000 lph Head- 50 meter For transfering domestic water from UG domestic tank to domestis water terrace tank Location: in WTP plant room

1

-

-

... More
Flow rate: 1000 lph Head- 50 meter For transfering flushing water from STP treated water tank to flushing water terrace tank Location: in STP area

1

-

-

... More
Receiving, Unloading, Handling, Installation, testing and commissioning of submersible non-clog, open impeller sump pump with vortex impeller 450 volts, 50 cycles AC supply of the following specifications:(3 Phase motor) with auto sequential change over with both pumps shut at low level, one pump working at mid level and both pump working and an alarm hooter at high level all pre set as required complete in all respects including motor control panel having all necessary accessories & safety devices of standard specifications and suitable for receiving incommer cable from main plumbing panel to conncet sump pump panel complete as required. Sump Pump- Drainage Sumps (Basement) Discharge: 300 lpm Head : 25 metre HP : 3 HP or As required. Casing : Aluminium alloy /C.I Impeller & Shaft: S.S. 410 Solid Handling Capacity: 20 mm Length of water proof cable with each pump: 15 meter Length of GI lifting chain with each pump: 5 Meter. Level controller Quantity : 2 Nos. (1W+1S) per set

1

-

-

... More
ELECTRICAL WORKS:

-

-

-

... More
750KVA COMPACT SUBSTATION OF 11KV/0.415 KV, having 1 incoming 400A 11kV HT VCB & 1 no. Dyn11, 11kV/0.415kV 750 KVA Oil Cooled Transformer with Off load Tap Changer & 1200A LT ACB Breaker with BMS compatible relay complete as per equipment data sheet and including the following, i) Supply, loading & unloading to the location at site of installation. ii) Installing, testing & commissioning generally as specified and shown on drawings. iii) Termination of incoming/outgoing cables as required and or as specified including the necessary cu Bus Bar extension chambers, adopter box etc., v) Inspection of the above by Electricity Supply Board and getting the approval at site of installation. vi) with all required structural supports/frames. vii) Copper Tinned Bus Bars ix) BMS Compatibility with all necessary potential free contacts.

1

-

-

... More
Supply,Installation, testing and commissioning of : 320 KVA at 0.8 PF 415V 3 Ph 50 Hz Diesel Generating Set (Radiator Type with accoustical Enclosure) Prime Power rated for unlimited no. of hours @ 80% load factor including all accessories complete with: i) Rubber-in-shear vibration mounts ii) Starting battery & leads & charger panel iii) Residential duty silencer with flanges. iv) Flexible connections v) Foundation bolts vi) Radiator heat exchanger with all accessories. vii) AMF Logic Control (PLC Based) Panel in IP42 with generator control unit MS Enclosure Powder coated to be mounted separately with isolator (MCCB) of suitablerating & all other necessary components and accessories as specified and are required for the satisfactory working of the system viii) All internal power & control cabling between the D.G. Set & the associated AMF Panel. The cables selection shall be from one of the Approved Vendor List. ix) Rate shall also include loading/unloading of the D.G. set to the proposed location.

2

-

-

... More
Supply,Installation, testing and commissioning of 1# 15KVA, 3Ph Inverter with 30 Min battery backup complete with all required accessories to complete the job.

1

-

-

... More
Scope of work covers supply, unloading ,Installation, testing and commissioning of the system as per the technical specification & technical data sheet, installation cost shall include testing & commissioning also.Necessary cabling between UPS and batteries / battery breaker etc. shall be a part of UPS tender.UPS input & output cable from UPS shall be supplied & terminated by other vendors.Necessary control cabling between different units of UPS shall be a part of UPS offer (If required). UPS installation cost shall include supply of 400mm MS Angle for UPS for bottom cable terminations. The angle frame shall be powder coated with shade same as UPS.Vendor to submit dimensional GA drawing of UPS / Batteries /Isolation Transformer along with offer. 5 KVA online, double conversion, operating in Parallel configuration(1+1) single Phase Input & single phase output with SNMP Card. # AC - AC Efficiency in Double Conversion mode upto 96%. # Power Factor Compatibility from 0.9 lagging to 0.9 leading. # Low Input Current Harmonic Distortion of 3%. # Input Power Factor 0.99 Operating in parallel redundant configuration(1+1) and as per the specifications and drawings. (please refer tender drawings and specs)alongwith : a) 12 V Lead Acid SMF batteries suitable for 30 mins back up time on each UPS b) Powder Coated MS Racks c) Interconnection cable between UPS & Battery breaker , battery interconnecting cable , c) MCCB breaker for Battery Isolation d) Base Angle of 400 mm Height e) For safety purpose there should be PVC cover above batteries f) Inbuilt isolation Transformer

12

-

-

... More
Supply Installation testing and commissioninhg of ESE type Air terminal/ lightning arrestor with conduits, cables, down conductors, saddles, fixing tape, bnding, clamp including all necessary accessories as per EIC approval.

1

-

-

... More
Supply Installation testing and commissioninhg of ESE type Air terminal/ lightning arrestor with conduits, cables, down conductors, saddles, fixing tape, bnding, clamp including all necessary accessories. Supporting mast of 8mtr length

1

-

-

... More
Supply Installation testing and commissioninhg of ESE type Air terminal/ lightning arrestor with conduits, cables, down conductors, saddles, fixing tape, bnding, clamp including all necessary accessories. 25X6 mm GI strip for down conductors with proper insulated supports and all accessries as per EIC approval.

300

-

-

... More
Supply Installation testing and commissioninhg of ESE type Air terminal/ lightning arrestor with conduits, cables, down conductors, saddles, fixing tape, bnding, clamp including all necessary accessories. Lightning strike Counter.

1

-

-

... More
Supply, installation, testing and commissioning of cubicle type panels as specified and shown on drawing. i) Main AL busbars with bar type feeder connections & all internal wiring and connections. ii) Earthing all components,frame etc. to a common internal earth bar. iii) Painting all sheet metal works. iv) All accessories & supporting structure,base etc., v)Double compression Brass glands and crimping lugs for sending and receiving ends. vi) All ammeters with C.T's and voltmeter and energy meters with necessary fuses. vii) All Load Managers to have parameters like KW, KVA, A, V, PF,KVAR, Active & Reactive component of power, RS-485 port to have BMS compatibility as required & desired to complete the system. vii) Panel components as specified and as required. viii) MS base frame. ix) All switch gear to have short circuit levels as specified. Main LT Panel as required, specified and shown on drg.

1

-

-

... More
Supply, installation, testing and commissioning of cubicle type panels as specified and shown on drawing. i) Main AL busbars with bar type feeder connections & all internal wiring and connections. ii) Earthing all components,frame etc. to a common internal earth bar. iii) Painting all sheet metal works. iv) All accessories & supporting structure,base etc., v)Double compression Brass glands and crimping lugs for sending and receiving ends. vi) All ammeters with C.T's and voltmeter and energy meters with necessary fuses. vii) All Load Managers to have parameters like KW, KVA, A, V, PF,KVAR, Active & Reactive component of power, RS-485 port to have BMS compatibility as required & desired to complete the system. vii) Panel components as specified and as required. viii) MS base frame. ix) All switch gear to have short circuit levels as specified. Floor Panel as required, specified and shown on drg.

7

-

-

... More
Supply, installation, testing and commissioning of cubicle type panels as specified and shown on drawing. i) Main AL busbars with bar type feeder connections & all internal wiring and connections. ii) Earthing all components,frame etc. to a common internal earth bar. iii) Painting all sheet metal works. iv) All accessories & supporting structure,base etc., v)Double compression Brass glands and crimping lugs for sending and receiving ends. vi) All ammeters with C.T's and voltmeter and energymeters with necessary fuses. vii) All Load Managers to have parameters like KW, KVA, A, V, PF,KVAR, Active & Reactive component of power, RS-485 port to have BMS compatibility as required & desired to complete the system. vii) Panel components as specified and as required. viii) MS base frame. ix) All switch gear to have short circuit levels as specified. x) VFD's of specific rating. Ventilation Panel as required, specified and shown on drg.

2

-

-

... More
Supply, installation, testing and commissioning of cubicle type panels as specified and shown on drawing. i) Main AL busbars with bar type feeder connections & all internal wiring and connections. ii) Earthing all components,frame etc. to a common internal earth bar. iii) Painting all sheet metal works. iv) All accessories & supporting structure,base etc., v)Double compression Brass glands and crimping lugs for sending and receiving ends. vi) All ammeters with C.T's and voltmeter and energy meters with necessary fuses. vii) All Load Managers to have parameters like KW, KVA, A, V, PF,KVAR, Active & Reactive component of power, RS-485 port to have BMS compatibility as required & desired to complete the system. vii) Panel components as specified and as required. viii) MS base frame. ix) All switch gear to have short circuit levels as specified. APFC Panel as required, specified and shown on drg.

1

-

-

... More
Supply, Installation, testing & commissioning of light Fixtures complete with: a) All fixing accessories & mounting bracket. b) Earthing of fittings. c) Connections from the ceiling rose or junction box to the light fixtures including the terminations with all necessary accessories of Recess mounted glare free round LED Downlight with pressure die cast Aluminium housing and high transmitive Polycarbonate diffuser, (15W- 18 W), 1500-1600 Lumens(minimum), IP-20, CCT/CRI- 4000K/5700K, 80, Electronic ballast, similar to Wipro make - Mollis-LD06-221-XXX-40-XX or its equivalent item of Philips /Jaquar Lighting/Lighting technology/Havels/ as per tender specification & Clients/EIC approval. Locations- Cabins.

200

-

-

... More
Supply, Installation, testing & commissioning of light Fixtures complete with: a) All fixing accessories & mounting bracket. b) Earthing of fittings. c) Connections from the ceiling rose or junction box to the light fixtures including the terminations with all necessary accessories of Recess mounted Round LED COB adjustable Downlight with pressure die cast Aluminium housing and reflector with power consumption (7W-9 W) having system lumen output of 700-900 Lumens, IP-20,CCT/CRI-3000K/4000K, 80,.Electronic Balast, similar to Wipro-(LD98-131-038-40-XX) or its equivcalent item of Philips/ Jaquar Lighting/Havels/Lighting Technology as per tender specification & Clients/EIC approval. Location- Cabins, Toilets, Corridors etc.

250

-

-

... More
Supply, Installation, testing & commissioning of light Fixtures complete with: a) All fixing accessories & mounting bracket. b) Earthing of fittings. c) Connections from the ceiling rose or junction box to the light fixtures including the terminations with all necessary accessories of ceiling Suspended decorative hanging light with aluminium powder coated housing dome shaped, IP-20, 40W(max)-2300 Lumens, CCT/CRI-3000K/80, Electronic Balast, similar to Wipro make-Picasso dome or its equivalent item of Philips/ Havels/Jaquar Lighting/Lighting Technology as per tender specification & clients/ EIC approval. Location- Cafeteria

6

-

-

... More
Supply, Installation, testing & commissioning of light Fixtures complete with: a) All fixing accessories & mounting bracket. b) Earthing of fittings. c) Connections from the ceiling rose or junction box to the light fixtures including the terminations with all necessary accessories of flexible LED strips 8-10W/m(maximum) IP33, Strip light system lumen output should be minimum 600-800lm /m , CCT/ CRI -3000K/80 , Electronic Balast, similar to Wipro make- or its equivalent product of Philips/ Jaquar Lighting/ Lighting technology/Havels as per technical specification & clients/ EIC approval. Location- As per Layout

1000

-

-

... More
Supply, Installation, testing and commissioning of decorative hanging lights as per the design aesthetics of the region concerned(Reception, cafeteria) as per acceptance and staisfaction of EIC. 5/8 watt, CCT-3000K, Die cast alluminium body with good finish,etc. Similar to Havells Make, Fusion Pendant, 1LSE27D180.

6

-

-

... More
Supply, Installation, testing & commissioning of light Fixtures complete with: a) All fixing accessories & mounting bracket. b) Earthing of fittings. c) Connections from the ceiling rose or junction box to the light fixtures including the terminations with all necessary accessories ceiling suspended Light fixture , Location- Basement level parking floors.

50

-

-

... More
Supply, Installation, testing & commissioning of light Fixtures complete with: a) All fixing accessories & mounting bracket. b) Earthing of fittings. c) Connections from the ceiling rose or junction box to the light fixtures including the terminations with all necessary accessories Tube Light.

60

-

-

... More
Supply, Installation, testing & commissioning of 2x2 tile light Fixtures complete with: a) All fixing accessories & mounting bracket. b) Earthing of fittings. c) Connections from the ceiling rose or junction box to the light fixtures including the terminations with all necessary accessories with aluminium powder coated housing IP-20, 40W(max)-2300 Lumens, CCT/CRI-4000K/5700K, /80, Electronic Balast. Make-Philips, Havells etc.

150

-

-

... More
Supply, Installation, testing & commissioning of bulkhead light Fixtures complete with: a) All fixing accessories & mounting bracket. b) Earthing of fittings. c) Connections from the ceiling rose or junction box to the light fixtures including the terminations with all necessary accessories with aluminium powder coated housing IP-20, 40W(max)-2300 Lumens, CCT/CRI-4000K/5700K, /80, Electronic Balast. Make-Philips, Havells, cromption etc.

10

-

-

... More
Supply, Installation and commissioning of Conduit wiring for lights/ socket outlets consisting of: a) Wiring in 25mm FRLS HMS PVC Conduit as required with all accessories, screws,spacers,clamps, z-sections etc., b) 1100V grade FRLS PVC insulated multistranded Cu wires. c) Insulated or base protective earth. :Primary wiring of all power points using 2x4+ 1x2.5 PE Cu PVC Wires.

60

-

-

... More
Supply, Installation, Testing & Commissioning of Conduit wiring for lights/ socket outlets consisting of: a) Wiring in 25mm FRLS HMS PVC Conduit as required with all accessories, screws,spacers,clamps, z-sections etc., b) 1100V grade FRLS PVC insulated multistranded Cu wires. c) Insulated or base protective earth. : Primary wiring of Lights/Fans/Power Points etc. using 2x2.5 + 1x1.5PE Cu PVC Wires.

250

-

-

... More
Supply, Installation, Testing & Commissioning of Conduit wiring for lights/ socket outlets consisting of: a) Wiring in 25mm FRLS HMS PVC Conduit as required with all accessories, screws,spacers,clamps, z-sections etc., b) 1100V grade FRLS PVC insulated multistranded Cu wires. c) Insulated or base protective earth. : Secondary wiring points extending primary circuits to various light points using 2x2.5 + 1x1.5PE Cu PVC Wires.

150

-

-

... More
Supply, Installation, Testing & Commissioning of Conduit wiring for lights/ socket outlets consisting of: a) Wiring in 25mm FRLS HMS PVC Conduit as required with all accessories, screws,spacers,clamps, z-sections etc., b) 1100V grade FRLS PVC insulated multistranded Cu wires. c) Insulated or base protective earth. : Secondary wiring points extending primary circuits to various light points using 2x1.5 + 1x1.5PE Cu PVC Wires.

400

-

-

... More
Power Point Wiring : Conduit wiring for lights fan socket outlets as per the mode of measurements described in the specifications consisting of : a) Wiring in 25/32/40/50 mm Dia PVC FRLS conduit & FR FLEXIBLE Conduit using multiple circuits as per specification as required/raceway as required.b) 1100V grade PVC insulated Cu multi-stranded ZHFR required/raceway as required.b) 1100V grade PVC insulated Cu multi-stranded ZHFR wires/Cables.c) Lighting Point wiring Shall be done in Black colour Pvc FRLS wires/Cables.c) Lighting Point wiring Shall be done in Black colour Pvc FRLS wires.Point wiring for work station area Shall be done in Floor Truncking using flexible white black ZHFR cables, Insulated or base protective earth----Primary Circuit wiring for all COMPUTER points Area using 3x2.5 Cu FLEXIBLE PVC WHITEColour cable.

70

-

-

... More
Power Point Wiring : Conduit wiring for lights fan socket outlets as per the mode of measurements described in the specifications consisting of : a) Wiring in 25/32/40/50 mm Dia PVC FRLS conduit & FR FLEXIBLE Conduit using multiple circuits as per specification as required/raceway as required.b) 1100V grade PVC insulated Cu multi-stranded ZHFR required/raceway as required.b) 1100V grade PVC insulated Cu multi-stranded ZHFR wires/Cables.c) Lighting Point wiring Shall be done in Black colour Pvc FRLS wires/Cables.c) Lighting Point wiring Shall be done in Black colour Pvc FRLS wires.Point wiring for work station area Shall be done in Floor Truncking using flexible white black ZHFR cables, Insulated or base protective earth----Secondary Circuit wiring extending primary points for all COMPUTER points Area using 3x2.5 Cu FLEXIBLE PVC WHITEColour cable.

100

-

-

... More
Supply, installation, testing and commissioning of switch socket with required back box and face plates as described below complete with: 1) GI box of suitable size with earthing 2) Plate type switches & sockets. General office work station complete with: i) 3# 5/15A socket ii)1#15A switch with indicating lamp iii) 1# data

150

-

-

... More
Supply Installation switch, sockest with G. I. back box with earthing. etc. incuding complete accessiors to finish the job. Make:- Legrand Mosaic, Schneider, Norysis etc. RANGE/ SUBJECT TO CLIENTS/ARCHITECTS APPROVAL--5 nos. 5A switch with back box & face plate

70

-

-

... More
Supply Installation switch, sockest with G. I. back box with earthing. etc. incuding complete accessiors to finish the job. Make:- Legrand Mosaic, Schneider, Norysis etc. RANGE/ SUBJECT TO CLIENTS/ARCHITECTS APPROVAL-- 8nos. 5A switch with back box & face plate

20

-

-

... More
Supply Installation switch, sockest with G. I. back box with earthing. etc. incuding complete accessiors to finish the job. Make:- Legrand Mosaic, Schneider, Norysis etc. RANGE/ SUBJECT TO CLIENTS/ARCHITECTS APPROVAL-- 2nos. 5A switch with back box & face plate

50

-

-

... More
Supply Installation switch, sockest with G. I. back box with earthing. etc. incuding complete accessiors to finish the job. Make:- Legrand Mosaic, Schneider, Norysis etc. RANGE/ SUBJECT TO CLIENTS/ARCHITECTS APPROVAL-- 12nos. 5A switch with back box & face plate

25

-

-

... More
Supply Installation switch, sockest with G. I. back box with earthing. etc. incuding complete accessiors to finish the job. Make:- Legrand Mosaic, Schneider, Norysis etc. RANGE/ SUBJECT TO CLIENTS/ARCHITECTS APPROVAL--1 nos. 15A switch & 1 No. of 5/15A socket with back box & face plate

50

-

-

... More
Supply Installation switch, sockest with G. I. back box with earthing. etc. incuding complete accessiors to finish the job. Make:- Legrand Mosaic, Schneider, Norysis etc. RANGE/ SUBJECT TO CLIENTS/ARCHITECTS APPROVAL-- 1nos. 15A switch & 3 nos. of 5/15A socket, 1 data , 1 TV with back box & face plate

10

-

-

... More
Supply Installation switch, sockest with G. I. back box with earthing. etc. incuding complete accessiors to finish the job. Make:- Legrand Mosaic, Schneider, Norysis etc. RANGE/ SUBJECT TO CLIENTS/ARCHITECTS APPROVAL-- 1nos. 15A switch & 4 nos. of 5/15A socket, 2 data with back box & face plate

10

-

-

... More
Supply Installation switch, sockest with G. I. back box with earthing. etc. incuding complete accessiors to finish the job. Make:- Legrand Mosaic , Schneider, Norysis etc. SUBJECT TO CLIENTS/ARCHITECTS APPROVAL---1 nos. switch with back box & face plate

20

-

-

... More
Supply, installation testing and commissioning of ceiling fans 1200mm dia

160

-

-

... More
Supply, installation testing and commissioning of exhaust fans 400mm dia

60

-

-

... More
Supply & installation of single compartment hot dip galvanised G.I raceway/Trunking of 2mm thick with 100 microns for power & data/tel as shown in drg. At ceiling/Floor level complete with: a) Wall chasing/making good. b) Raceway including cover plate etc. as per details and as specified and shown on drawings. c) All bends, T joints & junction boxes etc. as specified and shown complete. 300 X 40mm SingleCompartment Raceway With openable cover

100

-

-

... More
Supply & installation of single compartment hot dip galvanised G.I raceway/Trunking of 2mm thick with 100 microns for power & data/tel as shown in drg. At ceiling/Floor level complete with: a) Wall chasing/making good. b) Raceway including cover plate etc. as per details and as specified and shown on drawings. c) All bends, T joints & junction boxes etc. as specified and shown complete. 200 X 40mm SingleCompartment Raceway With openable cover

300

-

-

... More
Supply & installation of single compartment hot dip galvanised G.I raceway/Trunking of 2mm thick with 100 microns for power & data/tel as shown in drg. At ceiling/Floor level complete with: a) Wall chasing/making good. b) Raceway including cover plate etc. as per details and as specified and shown on drawings. c) All bends, T joints & junction boxes etc. as specified and shown complete. 100 X 40mm SingleCompartment Raceway With openable cover

400

-

-

... More
Supply & installation of single compartment hot dip galvanised G.I raceway/Trunking of 2mm thick with 100 microns for power & data/tel as shown in drg. At ceiling/Floor level complete with: a) Wall chasing/making good. b) Raceway including cover plate etc. as per details and as specified and shown on drawings. c) All bends, T joints & junction boxes etc. as specified and shown complete. 50 X 40mm SingleCompartment Raceway With openable cover

150

-

-

... More
Supply, installation, testing and commissioning of Hot Deep Galvanised, 2.0 mm thick, Perforated Cable Tray, for carrying Electrical / IT/TEL. cables. All the Trays will be supported either by Gripple make Steel wire Ropes or by fully threaded rods or by providing M.S.Angle / Channel supports. The rates shall be inclusive of providing of Gripple make steel ropes, Threaded rods with Anchor fasteners, Clamps, bolts, nuts including all the necessary required material. 200 x 50 mm

500

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. 2XFY copper XLPE cables of size 4 C 10 sqmm CU

400

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. A2XFY copper XLPE cables of size 3.5C 50 sqmm AL.

500

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. A2XFY copper XLPE cables of size 3.5C 35sqmm AL.

400

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. A2XFY copper XLPE cables of size 3.5C X25 sqmm AL.

300

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. A2XFY copper XLPE cables of size 3.5C X 300 sqmm AL.

200

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. A2XFY copper XLPE cables of size 3.5C X 240 sqmm AL.

200

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. A2XFY copper XLPE cables of size 3.5C X 70 sqmm AL.

100

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. A2XFY copper XLPE cables of size 3.5C X 120 sqmm AL.

250

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. A2XFY copper XLPE cables of size 3C X 35 sqmm AL.

200

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. A2XFY copper XLPE cables of size 3C X 50 sqmm AL.

100

-

-

... More
Supply and laying heavy duty 1100V grade XLPE sheathed & armoured Fire Retarded Low Smoke (FRLS) cables indoor with Cu conductors as speci- fied and shown on drgs. complete with: a) Cable clamps on walls, columns, beams, built-up trenches, cable markers etc. for indoor cables.b) Covering bricks or tiles, cable markers etc for outdoor cables.c) Earthing the glands armouring etc. A2XFY copper XLPE cables of size 3C X 150 sqmm AL.

50

-

-

... More
Cable Termination: Making cable and terminations including brass double compression glands and crimping type Aluminium/copper lugs for cable sizes mentioned as of aluminium or copper. 3.5 x 95, 3.5 x 70, 3C X 70, 2C X 70,3.5 x 50

20

-

-

... More
Cable Termination: Making cable and terminations including brass double compression glands and crimping type Aluminium/copper lugs for cable sizes mentioned as of aluminium or copper. 3.5C x 35, 3.5 x 25, 3C X 35, 3C X 25,4 x 16, 2C X 35, 2C X 25

50

-

-

... More
Cable Termination: Making cable and terminations including brass double compression glands and crimping type copper lugs for cable sizes mentioned as of aluminium or copper.4 x 10, 4 x 6, 3 x 10, 3 x 6,

100

-

-

... More
Cable Termination: Making cable and terminations including brass double compression glands and crimping type copper lugs for cable sizes mentioned as of aluminium or copper.4 x 4, 3 x 4 , 4 x 2.5, 3 x 2.5

100

-

-

... More
Cable Termination: Making cable and terminations including brass double compression glands and crimping type Aluminium/copper lugs for cable sizes mentioned as of aluminium or copper. 3.5 x 300, 3.5Cx240 sq.mm

10

-

-

... More
SITC of following MCCB/MCB, distribution boards. Those distribution boards shall be totally enclosed, Indoor Type, with double door, vertical, surface mounting type. The Outer door shall be hinged type with push in type spring / magnetic lock & Inner door shall be fixed up with screws with cutouts for MCB operation. The proper size of Copper Busbar of at least 1.5 times the rating of incomer MCB / MCCB, with adequate space for termination of incoming and outgoing cables shall be provided inside DB. Removable undrilled Gland Plates, fabricted using 14swg, CRCA Sheet, has to be provided at top & bottom of each DB. Proper type of brackets, fabricated using 40 x 6mm, MS Strip/Flat, shall be provided at back side of DB, for mounting it on wall or column by providing MS Frame. In case of MCCB as an Incomer, the MCCB shall be provided in separate compartment. The MCCB shall have front drive mechanism and door interlock. The DB shall be fabricatedout of 1.6 mm thick CRCA sheet steel. DB shall be completely wired up, up to incoiming and outgoing terminals by PVC insulated flexible copper wire of adequate rating. All RCCB installed in LDB and PDB shall be rated for 100ma leakage current respectively. All MCB in Lighting as well as in Power DB shall be suitable for Motive power (Curve C). Wherever standard DB's of MCB manufacturers are available, same shall be used.APPROVED MAKE- LEGARND/ SCHNEIDER /HAVELLS 6WAY PPI TPN FOR POWER DB-1 &PDB-2, PDBConsisting With :- Incomer - 40Amp, TPN, 10KA MCB ,SUB INCOMER - 3 NOS. 40A DP RCCB ,OUTGOING - 16/6A, SP, MCB - 12 Nos. AS PER DB SCHEDULE

16

-

-

... More
Supply, installation, testing & commissioning of 500V Distribution Boards as specified& shown on drawing with i) Copper busbars together with tapped neutral bar for individual phases. ii) Copper earth strip with tapping for EECiii) Busbar mounting mcb's individually lockable in off position.' iv) Interconnections and earthing. v) Sheet steel enclosure suitable for recessed or surface mounting with hinged lockable doors interlocked with the incomer switch.vi) Phase to phase barriers in case of 3Ph boards.'vii) Necessary support frame & painting labelling etc complete.viii) circuit wiring Power coated MS connector trunking as required with cover for the complete perfect dressing, Emergency Lighting Distribution Boards as specified Emergency Lighting Distribution Board ELDB 10 Way SPN DB consisting of Incomer : i) 25 Amp DP ELMCB 100mA Outgoing :i) 10# 6/10/16 Amp SP MCB

9

-

-

... More
SITC of following MCCB/MCB, distribution boards. Those distribution boards shall be totally enclosed, Indoor Type, with double door, vertical, surface mounting type. The Outer door shall be hinged type with push in type spring / magnetic lock & Inner door shall be fixed up with screws with cutouts for MCB operation. The proper size of Copper Busbar of at least 1.5 times the rating of incomer MCB / MCCB, with adequate space for termination of incoming and outgoing cables shall be provided inside DB. Removable undrilled Gland Plates, fabricted using 14swg, CRCA Sheet, has to be provided at top & bottom of each DB. Proper type of brackets, fabricated using 40 x 6mm, MS Strip/Flat, shall be provided at back side of DB, for mounting it on wall or column by providing MS Frame. In case of MCCB as an Incomer, the MCCB shall be provided in separate compartment. The MCCB shall have front drive mechanism and door interlock. The DB shall be fabricatedout of 1.6 mm thick CRCA sheet steel. DB shall be completely wired up, up to incoiming and outgoing terminals by PVC insulated flexible copper wire of adequate rating. All RCCB installed in LDB and PDB shall be rated for 100ma leakage current respectively. All MCB in Lighting as well as in Power DB shall be suitable for Motive power (Curve C). Wherever standard DB's of MCB manufacturers are available, same shall be used.APPROVED MAKE- LEGARND/ SCHNEIDER /HAVELLS 10 WAY PPI TPN FOR UPSDB Consisting With :- Incomer - 40Amp, TPN, 10KA MCB ,SUB INCOMER - 3 NOS. 40A DP RCCB ,OUTGOING - 16A, SP, MCB - 18 Nos. AS PER DB SCHEDULE

5

-

-

... More
Supply, Installation, testing and commissioning of GI earthing strips of 25X6mm GI earth strips.

150

-

-

... More
Supply, Installation, testing and commissioning of GI earthing strips of 50X6mm GI earth strips.

150

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.