Gauhati University Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Gauhati University Tender
Laboratory Equipment and Services
Eprocure
Opening Date22 Jan 2025
Closing Date13 Feb 2025
Tender Amount₹ 40,00,000
Costs
EMD
₹ 80,000Document Cost
₹ 800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_GU_42295_1Tender No
GU/BET/DHR/2024-25/STII/1 Dated 21.01.2025Tender Authority
Gauhati University ViewPurchaser Address
-Website
http://https://www.gauhati.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Vacuum Oven
Specification: 1.Volume(L): 60-80
2.Temperature range (°C): RT+5-250
3.Temperature resolution (°C): 0.1(at 100°C)
4.Temperature variation (°C): ± (at100°C)
5.Heating power (W): 2100
6.Vaccum range 0 ~ 1 atm
7.Timer: 1min ~ 99hr59min
8.Vaccum connector (mm): Ø10
9.Venting connector (mm): Ø10
10.Inner size (mm): 400x400x400
11.Dimension (mm): 625x585x710
1
-
-
... More
Constant Temperature Incubator
Specification:
1.Volume: [L] 100
2.Temperature Range [°C]: RT.+ 5~65 3.Temperature uniformity of working area [°C]: ±0.2 at 37°C and 25°C RT 4.Temperature Stability [°C]: ±0.1 at 37°C
5.Temperature Controller: Digital Display with PID automatic regulation, Button Control
6.Timer 1 min ~ 99 hr 59 min
7. Safety: Independent safety temperature protection, Open door alarm function
8. Heating Capacity [W]: 340 9.Shelves [included / max.]: 3/4
10.Inner Dimensions [WxDxH in mm] 480 X 480 X 495
11.Outer Dimensions [WxDxH in mm] 560 X 560 X 760
12.Power supply AC 220~240 V, 50/60 Hz
1
-
-
... More
Hydraulic Analogue laboratory press
Specification:
1.Type: Hydraulic
2.Diameter of Spindle: 35 millimeter
3.Maximum Load on Piston: 25 tonne
4.Closing Force (kN): 200
5.Piston Stroke: 22 millimeter
6.Capacity per platen (kW): 1.6
7.Specific Platen Pressure (N/mm2): 1.05
8.Press Platen Size (mm): 196 x 196
9.Depth: 480 millimeter
10.Heating Type: Electrical
11.Width: 790 millimeter
12.Cylinder Stroke: 100 millimeter
13.Display: Analog
14.Width Between Pillars: 150 millimeter
15.Height: 970 millimeter
16. Accessories: Pneumatic front shield, Mould cart (moveable) or Mould rack
17. Maximum Temperature: 200°C
18. Temperature Accuracy (degree Celsius): +/- 1.0
1
-
-
... More
High Performance Computer
Specification: 1.Capacity (in kVA/kW): 2kVA/2kW Single phase Input/Single phase output 2.Technology and Capability a) True online double conversion UPS, VFI-SS-111
b) UPS should be designed at Rated PF of 1
c) 3- level IGBT based inverter and rectifier
d) Should have arrangement for paralleling up to 4 UPS for redundancy, if required Input 3.Input facility-Phases/ Wires: 1-phase/2-wire & Gnd (Phase & Neutral + Ground) 4.Input Voltage Range: 160-300 VAC (On 100% Load) 5.Input Power factor: ≥0.99 (With full linear Load) 6.Input Current Harmonic Distortion (THDi): 5% at full load in normal UPS operating voltage 7.Generator Compatibility: Compatibility to genset supply required 8.Input Frequency Range: 44-66 Hz
Output 9.Nominal Output Voltage: 230 V (adjustable to 220/230/240 VAC) 10.Output Voltage regulation: ±1% 11.Nominal Output Frequency: 50/60 Hz ± 0,1 % 12.Output wave form: Pure sine wave 13.Output Voltage distortion (THDv) :
~2% Full Linear load
~5% Full Non-Linear load
13.Crest Factor: 3;1
Efficiency AC/AC (Overall efficiency): Up to 92%
1
-
-
... More
Electroporation System (Eukaryotic and or Prokaryotic System)
Specification: 1.Outputs: Waveform: Exponential-decay or square-wave Voltage: 10-3000 V
2. Capacitance: 10-500 V: 25-3275 µF in 25 µF increments 500-3000 V: 10,25,50 µf3.
Parallel resistance: 20-1000Ω in 50 Ω increments, plus infinity
4.Simple resistance: 20Ω minimum at 10-2500 V
600 Ω minimum at 2500-3000 V
5.Square wave timing: 10-500 V: 0.05-10 ms duration in 0.05 ms
Increments, 10-100 ms duration in 1 ms
Increments, 1-10 pulses, 0.1-10 sec interval
500-3000 V: 0.05-5 ms duration in 0.05 ms
Increments, 1-2 pulses, 5 sec minimum intervals
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%