Food Corporation Of India Tender
... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 40,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_FCI_684736_1Bid Award Id
ViewTender No
01/EE/2022-23Tender Authority
Food Corporation Of India ViewPurchaser Address
-Website
http://http://fci.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Re-fixing of following size old dismantaled steel conduit with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
... More
20mm
290
-
-
... More
25mm
125
-
-
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
-
-
-
... More
3 x 1.5 sq. mm
2300
-
-
... More
6 x 1.5 sq. mm
290
-
-
... More
9 x 1.5 sq. mm
110
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
-
-
-
... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
790
-
-
... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
150
-
-
... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
460
-
-
... More
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
30
-
-
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
15
-
-
... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
75
-
-
... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required.
430
-
-
... More
Supplying and fixing 8 way double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
9
-
-
... More
Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)
5
-
-
... More
Supplying and fixing 63 A TP&N MCB inside the existing panel board including deilling holes in panel, Mking connections etc as required
5
-
-
... More
Supplying and fixing 40A , double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
12
-
-
... More
Supplying and fixing of following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Single pole
35
-
-
... More
Single Pole & neutral
13
-
-
... More
Supplying and fixing 5/6 amps switch piano type/tumbler switch/ socket on the existing switch box/ cover including connections etc. as required.
108
-
-
... More
Supplying and fixing metal box of size 200 mm X 150 mm X 60 mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
36
-
-
... More
Supplying and fixing of 300 mm x 300 mm size metalic frame cover fabricated with 25 mm x 25 mm x 3 mm thick angle iron welded construction frame structured and 1.6 mm thick M. S. sheet cover plate with double hinges and knobe type locking arrangement including painting, making recess in wall, masonary, plastering & finishing the good
10
-
-
... More
Supplying and fixing of 600 mm x 600 mm size metalic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 2 mm thick M. S. sheet cover plate with double hinges and knobe type locking arrangement including painting, making recess in wall, masonary, plastering & finishing the good
4
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
15
-
-
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. Mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
25
-
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
1
-
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
2
-
-
... More
Supply and Laying of one No. PVC insulated & PVC sheathed/XLPE POWER CABLE of 1.1 kv grade armoured Al. cable compulsory ISI mark confirming to IS:7098/ PART –I / 88 with amendment no.1 as required direct in ground i/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd.
-
-
-
... More
CABLE SIZE 3.5 X 35 SQ.MM
11
-
-
... More
CABLE SIZE 4 X 16 SQ.MM
15
-
-
... More
CABLE SIZE 4 X 25 SQ.MM
10
-
-
... More
Supply and Laying of one number PVC insulated and PVC sheathed / XLPE XLPE POWER CABLE of 1.1 kv grade armoured Al. cable compulsory ISI mark confirming to IS:7098/ PART –I / 88 with amendment no.1 in the existing RCC/ HUME/ METAL pipe as required.
-
-
-
... More
CABLE SIZE 3.5 X 35 SQ.MM
4
-
-
... More
CABLE SIZE 4 X 16 SQ.MM
12
-
-
... More
CABLE SIZE 4 X 25 SQ.MM
6
-
-
... More
Supply and Laying of PVC insulated and PVC sheathed / XLPE XLPE POWER CABLE of 1.1 kv grade armoured Al. cable compulsory ISI mark confirming to IS:7098/ PART –I / 88 with amendment no.1 (clamped with 1mm thick saddle) on the wall surface as reqd.
-
-
-
... More
CABLE SIZE 4 X 16 SQ.MM
498
-
-
... More
CABLE SIZE 2 X 10 SQ.MM
200
-
-
... More
CABLE SIZE 4 X 25 SQ.MM
80
-
-
... More
Supplying and fixing of light class G.I. pipe of 50 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required.
7
-
-
... More
S/I/T/C of highly robust industrial luminaire suitable for single LED tube & 20w LED tube including all accessories i.e., installation on wall/truss/pipe, wiring with 1.5sqmm wire, painting, screw etc as required.
84
-
-
... More
Supplying, Installations, Testing and commissioning of 70watt LED high efficacy wellglass advanced design luminaires suitable for industrial use, housing made of pressure die cast aluminium powder coated with ingress protection of IP66, consumes lesser energy and maintain high lighting levels. Connection with 3x1.5sqmm FRLS copper wire, 1no. eyebolt provided for mounting purpose on godown truss/wall along with all accessories such as clamp, nuts, bolts, complete in all respect etc as required
50
-
-
... More
S/I/T/C 35W TO 40Wof energy saving Gate light post top , LED including all accessories i.e., supply of 1mtr 50mm dia GI pipe, B Class and grouting in the esixting RCC Column and fixing the fiting thereon including connections with 3x1.5sq mm wire, painting etc as required.
2
-
-
... More
S/I/T/C of 30W LED flood light with robust heat sink along with IP65 protection, including all accessories i.e., installation on wall/truss/pipe, wiring with 1.5sqmm wire, painting, screw etc as required.
10
-
-
... More
S/I/T/C of 100W LED flood light with robust heat sink along with IP65 protection, including all accessories i.e., installation on wall/truss/pipe, wiring with 1.5sqmm wire, painting, screw etc as required.
15
-
-
... More
SITC of Surface waterproof industrial luminaire with polycarbonate housing and diffuser suitable for twin 4ft T8 tube along with 2 Nos of 20/22 Watt LED polycarbonate T8 tube with in build driver with metal heat sink, of make Crompton :IPFC122LT8 & LGT8-20-865-2 and Installation, testing and commissioning of pre-wired,LED fitting,complete with all accessories and tube/lamp etc. directly on nceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required
54
-
-
... More
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required.
357
-
-
... More
Dismantling of pole/ street light standard/ strut embedded in brick ballast foundation etc. as required
20
-
-
... More
Supply, Installation, Shifting, testing & commissioning of Double door, outdoor cubicle type totally enclosed free standing type moisture, dust and vermin proof Panel Board of minimum size 1.2m x 1m x 0.4m made out of 2.0 mm thick CRCA sheet Steel IP 42 Wall / floor mounting type. The sheet steel shall undergo minimum 9 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect. All MCCB shall have thermalmagnetic release with adjustable over current,short circuit & Earth fault protection with trip history (Faulty phase, type of fault and interupted Current) as per specification & BOQ. All MCCB's shall
1
-
-
... More
be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with solid isolable neutral link. The breaking capacity specified is Ics value. All outgoing MCB's shall be C type with 10 KA breaking capacity. The fault withstanding capacity of panel shall be 25 KA rms for 1 sec. The above board shall be complete with 3 nos. phase indicating lights, flush AVF meter with, CT's, PT's, selector switches, protective fuses etc. at Incomer with all inter connections by min. 2.5 sq.mm. Copper wires.
-
-
-
... More
1 no. 200 Amp FP Moulded Case Circuit Breaker. (25 KA)
-
-
-
... More
1no. 200 Amp changeover switch
-
-
-
... More
3nos. 100 Amp FP Moulded Case Circuit Breaker. (25 KA)
-
-
-
... More
3nos. 63 Amp FP Miniature Circuit Breaker. (10 KA)
-
-
-
... More
5nos. 32 Amp DP Miniature Circuit Breaker. (10 KA)
-
-
-
... More
Supply, Installation, Shifting, testing & commissioning of cubicle type totally enclosed free standing type moisture, dust and vermin proof Feeder Pillar of minimum size 0.8mx0.8mx0.4m made out of 2.0 mm thick CRCA sheet Steel IP 42 Wall / floor mounting type. The sheet steel shall undergo minimum 9 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect. All MCCB shall have thermalmagnetic release with adjustable over current,short circuit & Earth fault protection with trip history (Faulty phase, type of fault and interupted Current) as per specification & BOQ. All MCCB's shall be Ics = 100% Icu, with rotary handle &
1
-
-
... More
pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with solid isolable neutral link. The breaking capacity specified is Ics value. All outgoing MCB's shall be C type with 10 KA breaking capacity. The fault withstanding capacity of panel shall be 25 KA rms for 1 sec. The above board shall be complete with 3 nos. phase indicating lights, flush AVF meter with, CT's, PT's, selector switches, protective fuses etc. at Incomer with all inter connections by min. 2.5 sq.mm. Copper wires.
-
-
-
... More
1no.125 Amp FP Moulded Case Circuit Breaker. (25 KA) Make Havells
-
-
-
... More
2nos. 63 Amp FP MCCB. (16 KA)
-
-
-
... More
3nos. 63 Amp FP MCB. (10 KA)
-
-
-
... More
2nos. 32 Amp DP Miniature Circuit Breaker. (10 KA)
-
-
-
... More
Less credit for dismantaled old damaged steel conduit and scrap
-
-
-
... More
20 mm
390
-
-
... More
25 mm
180
-
-
... More
Less credit for dismantaled old damaged 8 way MCB DB
5
-
-
... More
Less credit for dismantaled old damaged 4+12 way MCB DB
3
-
-
... More
Less credit for dismantled old damaged Single pole MCB 6 to 32 Amp
17
-
-
... More
Less credit for dismantled old damaged SPN MCB 6 to 32 Amp
10
-
-
... More
Less credit for dismantled old damaged 5/6Amp piano type switch
40
-
-
... More
Less credit for dismantaled old damaged 150 W HPSV Fitting
8
-
-
... More
Less credit for dismantaled old damaged Flourescent fitting
20
-
-
... More
Less credit for unservisable box type flourescent fitting and scrap
15
-
-
... More
Less credit for dismantaled old damaged cable termination M.S box and scrap
11
-
-
... More
Less credit for dismantled ACSR conductor
237
-
-
... More
Less credit for dismantled GI wire
120
-
-
... More
Less credit for dismantled insulatators
120
-
-
... More
Less credit for dismantled cross arms, flats, along with dismantled electrical panel
402
-
-
... More
Less credit for dismantled aluminium wires
90
-
-
Evaluation Notes How It Works ?
Potential Partner