Food Corporation Of India Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 22,200Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_FCI_570400_1Bid Award Id
ViewTender No
05/2020-21Tender Authority
Food Corporation Of India ViewPurchaser Address
-Website
http://http://fci.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
25 mm dia
703
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
3 x 1.5 sqmm
708
-
-
4 x 1.5 sqmm
360
-
-
5 x 1.5 sqmm
36
-
-
6 x 1.5 sqmm
48
-
-
9 x 1.5 sqmm
48
-
-
3 x 2.5 sqmm
420
-
-
6 x 2.5 sqmm
510
-
-
3 x 6 sqmm
582
-
-
Supplying and fixing of 40mm dia GI pipe in between bottom runner / truss in Godown with clamps painting etc complete as required.
216
-
-
Supplying and fixing metal box of sizes 200 mm X 150 mm X 75 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required
24
-
-
Supplying and fixing 5/6 Amp piano type switch on the existing switch box / cover including connections etc. as required.
120
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. FOR GROUP B
24
-
-
Supplying and fixing 8 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6
-
-
Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
1
-
-
Supplying and fixing 63 amps rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
2
-
-
Supplying and fixing 25 amps rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
24
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of Single pole Neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5
-
-
Modification of existing lighting fixture dismentled from the location and removing of accessories like ballast, starter and excess wiring from the body of the fitting and modification by providing and fixing internal wiring, rotor holder and 18/20 watt LED tube rod including marking of Text and number etc as required
20
-
-
Supplying of 18 to 20 watt LED luminar fixture complete with LED retrofit lamp and metalic box type batten fixture body for fixing suspended by conduit down rod or on surface with facility of conduit entry for wire connection ( As per manufacturers list attached) i/c marking of Text and number as required
129
-
-
Installation, testing and commissioning of all types lighting fixtures, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
149
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4
-
-
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required
50
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required
350
-
-
Supply,Installation,Testing and commissioning of 100Amp 4 pole changeover switch with encloser and side handle
1
-
-
Supplying of XLPE insulated & PVC tape innersheathed aluminium conductor armoured cable of 1.1 KV grade of following size confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required.
-
-
-
4 x 16 sqmm
57
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall, pole or steel structure surface as required.
-
-
-
Size not exceeding 35 sqmm (clamped with 1mm thick saddle)
37
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade at over head with 8 SWG dia GI wire, Shackle insulator, clamp, nut bolt cable clips etc as required
20
-
-
Supplying and fixing of 300 mm x 300 mm size metalic frame cover fabricated with 25 mm x 25 mm x 3 mm thick angle iron welded construction frame structured and 1.6 mm thick M. S. sheet cover plate with double hinges and knobe type locking arrangement including painting, making recess in wall, masonary, plastering & finishing the good (As per drawing)
12
-
-
The items are to be dismentalled during the execution of work are to be take away by the giving the credit to the estimate
-
-
-
Lighting fixtures, cable, wires, switch gears etc.
50
-
-