Department Of Housing And Urban Affairs Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Department Of Housing And Urban Affairs Tender

Civil And Construction
Civil Works Others
Eprocure
Opening Date1 Jun 2022
Closing Date21 Jun 2022
Tender Amount₹ 20,61,22,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying plain/reinforced cement croncrete works cement,coarse sand & 20 mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of formwork and reinforcement for reinforced cement concrete work (formwork and reinforcement will be measured and paid separately). Using Mixer Machine and Without using admixture, plasticiser. M25 grade concrete or Prop. 1:1.5:3

10127.13

-

-

... More
Steel Shuttering for vertical surface such as walls (any thickness), Liftshafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.

25067.03

-

-

... More
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202

500.62

-

-

... More
Roadwork Estimate

-

-

-

... More
Construction of Subgrade and Earthen Shoulders (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table (300-2 ( Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) from govt land

6567.58

-

-

... More
Granular Sub-Base with Coarse Graded Material ( Table:- 400-2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC,and compacting with vibratory roller to achieve the desired density,complete as per cl. 401( with an initial lead of 5 Km.) (II) for grading- II Material

385.65

-

-

... More
(Providing, laying, spreading and compacting graded stone aggregate of specifuc sizes to water bound mecadam specificationincluding spreading in uniform thickness,hand packing,rolling with vibratory roller 8010 tonnes in stages to proper grade and camber,applying and brooming requisite type of screeing/binding material to fill up the interstices of coarse aggregate,watering and compacting to the reqd density ( with an intial lead of 5.0 km)

385.65

-

-

... More
Providing and laying shaded interlocking concrete block pavement having thickness 80mm as per IS 15658 2006(Compressive strength 40 N/mm sq.

2571

-

-

... More
Direction and place identification sign upto 0.9sqm size board. Providing and erecting direction and place identification retro- Reflectrorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3 fixed over aluminium sheeting, 2mm thick with area not exceeding0.9sqm fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. (All the Steel work must be Tata/Sail/or any other approved brand)

1

-

-

... More
Footpath-Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600:1 , cement concrete not to be less than 150kg/cum, optimum moisture content to be determined during the trial length construction, concrete strength not to be less than 10Mpa at 7 days, mixed in a batching plant, transported to the site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)(Including carriage of mixed materials up to 10.0 Km initial lead from mixing plant.)

385.65

-

-

... More
Construction of precast RCC Railing of M 30 Grade…......

857

-

-

... More
Street Lighting (Providing and erecting street light mounted on a steel circular hollow pole of standard specifications for street lighting. 9 m high spaced 40 m apart, 1.8 m overhang on both sides if fixed in the median and on one side if fixed on the footpath, fixed on the concrete foundation.

29

-

-

... More
Ramp

-

-

-

... More
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breakingclods in returnfilling, dressing, water in gandramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.

221.65

-

-

... More
PCC 1:3:6 in foundation (Plain cement Concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed,placed in foundation and compacted by vibration including curing for 14 days)

14.24

-

-

... More
Providing and laying plain/reinforced cement croncrete works cement,coarse sand & 20 mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of formwork and reinforcement for reinforced cement concrete work (formwork and reinforcement will be measured and paid separately). Using Mixer Machine and Without using admixture, plasticiser. M25 grade concrete or Prop. 1:1.5:3

709.54

-

-

... More
Steel Shuttering for vertical surface such as walls (any thickness), Liftshafts, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.

681.7

-

-

... More
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202

105

-

-

... More
Construction of Subgrade and Earthen Shoulder

249.2

-

-

... More
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin- charge.

21

-

-

... More
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.

24.92

-

-

... More
Grille 18 AWG steel with powdercoat

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.