Bodoland Territorial Council Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 5,46,200Document Cost
₹ 5,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_BTC_34886_1Bid Award Id
ViewTender No
No. ACE-150/PWD/NIT/GoodwillTender Authority
Bodoland Territorial Council ViewPurchaser Address
-Website
http://https://www.bodoland.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
B . EARTH WORK Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting p g to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
(i) Private Land
6038.21
-
-
... More
Construction of Subgrade and Earthen Shoulders
Construction of subgrade and earthen shoulders with approved materials obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300.2 with lead upto1000 m as per Technical Specification Clause 303.1.
(i) Private Land
2385.74
-
-
... More
C . BASE AND SUB-BASE COURSES (NON BITUMINOUS)
a) By mix in Place Method. Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
(A) By Mix in Place Method
ii) For Grading II Material
G.S.B. Gr-II (150 mm)
1660
-
-
... More
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical Specification Clause 405.
(A) By Manual Means II) Grading III
b) Using Screnning Type-A (13.2mm Agg .)
W.B.M-III (75 mm)
830
-
-
... More
D. SURFACE COURSE (ICBP)
Providing and laying interlocking concrete block pavement with M40 having thickness 80mm as per technical specification clause 1504 including carriage.
a) Including Edge block/ Edge restraints
I.C.B.P. (80 mm)
11066.68
-
-
... More
E. Sign Board, Traffic Sign, KM Stones & Traffic Safety Work.
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
-
... More
Retro-reflectorised Traffic Signs (Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
(ii) 60 cm equilateral tringle
36
-
-
... More
Retro-reflectorised Traffic Signs ( Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
(iii) 60cm circular
8
-
-
... More
Retro-reflectorised Traffic Signs ( Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
(v) 60 cm x 60 cm Square
4
-
-
... More
Kilometre Stone ( Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 .
ii) Ordinary Kilometer Stone (Precast)
4
-
-
... More
Kilometre Stone ( Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 .
iv) 200 m stone (precast)
12
-
-
... More
(B) C.D. WORKS.
Construction of RCC Box Cell Culvert :L - 7.50 m, 1 No.
Size : 3.00m x 3.00m, 2 Cell
Rate as per Annx -
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out,construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
(i) Ordinary soil
(i) Upto 3 m depth
162.24
-
-
... More
Sand Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9
i) Sand filling
14.7
-
-
... More
PCC 1:3:6 in Foundation Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed Stone
i) PCC Grade M10
(i) Nomonal Mix 1:3:6
1.88
-
-
... More
PCC 1:2:4 in foundation,Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed Stone
iii) PCC Grade M20
(i) Nominal Mix 1:2:4
7.32
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
A. With Crushed Stone
IV. RCC GRADE M25
(i) Height up to 5m
66.2
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
A.With Crushed Stone
iv) RCC GRADE M25
(a) Height up to 5m
20
-
-
... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
26.2
-
-
... More
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
3.62
-
-
... More
Supplying, fitting and placing TMTTMT(Fe-500 D) reinforcement bar . (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
1.34
-
-
... More
Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
A. With crushed stone
3.52
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing force complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
16
-
-
... More
Back filling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
A. Grangular Materials
55.2
-
-
... More
Providing and laying curtain walls complete as per drawing and technical specification Clause 1304
(iii) Cement concrete grade M10
15.12
-
-
... More
Drainage spouts complete as per drawing and technical specifications Clause 1209
8
-
-
... More
P.C.C. M15 ordinary grade(1:2:5:5)levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211 .
A) With crushed stone
(i) Nominal mix (1:2.5:5)
6.21
-
-
... More
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 . ( A) With crushed stone
12.42
-
-
... More
Construction of flexible apron 1m thick comprising of loose stone boulders weighing not less then 25 kg beyond curtain wall .
33.2
-
-
... More
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301.
Rate as per Analysis - VI
Qnty as per Protection Calculation i) Protection for CD No. 1/1
106.77
-
-
... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302
(i) Boulder
Rate as per Analysis - VII
Qnty as per Protection Calculation i) Protection for CD No. 1/1
56.06
-
-
... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Rate as per Analysis - VIII
Qnty as per Protection Calculation i) Protection for CD No. 1/1
28.03
-
-
... More
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed.
a) 30 cm dia. RCC guard post with reinforcement of 6nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
20
-
-
... More
Construction of cold weather Bamboo bridge overall width of 3.70m and clear road way 3m with jungle wood post 20cm to 25cm dia 5nos. In each rows and rows being 2.1m. apart except for the navigable span which should be 3m. Post to be driven at least 180cm. or more below ground level including providing 20cm to 25cm center to center and placed over 20 cm dia, jungle wood dham, 15cm dia. jungle wood bracing collar fixed by bolts and nuts, straps etc. mature bholuka Bamboo cross groth all closely packed and tied 75cm wide track way made from 38mm thick 1st class local plank fixed on 75mmx100mm first class local wood battens 120cm apart and 3 lines of jati bamboo horizantal railing fixed in bholuka bamboo post placed at 210cm apart and white washed including all necessary nuts and bolts, coir ropes, struts, nails etc. complete with a layer of brushwood to exposed portion out-side trackway with earth topping complete as per direction of the department.
7
-
-
... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
86.11
-
-
... More
(C) Construction of RCC Box Cell Culvert : L -6.00 m, 1 No.
Size : 2.00m x 2.00m, 2 Cell
Rate as per Annx-
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
i) Ordinary soil
(i) Upto 3 m depth
85.3
-
-
... More
Sand Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9
7.7
-
-
... More
PCC 1:3:6 in foundation Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed Stone
i) P.C.C grade M 10
(i) Nominal mix 1:3:6
1.26
-
-
... More
PCC 1:2:4 in foundation,Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed Stone
iv) PCC Grade M20
(i) Nominal Mix 1:2:4
4.43
-
-
... More
Plain/reinforced cement concrete in sub-structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 .
(A) RCC GRADE M25
(iv) Height up to 5m
36.75
-
-
... More
Providing & laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
(A) RCC GRADE M25 (iv) For Solid slab Superstructure
(a) Height up to 5m
10.41
-
-
... More
Construction of RCC railing of M 25 grade in cast-in-situ with 20mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
21.5
-
-
... More
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
2.34
-
-
... More
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From primary Producer: TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/RINL) in super structure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
0.78
-
-
... More
Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
A. With crushed stone
1.82
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
6
-
-
... More
Back filling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
A. Grangular Materials
37.8
-
-
... More
Providing and laying curtain walls complete as per drawing and technical specification Clause 1304
(iii) Cement concrete grade M10
9.98
-
-
... More
Drainage spouts complete as per drawing and technical specifications Clause 1209
4
-
-
... More
Construction of flexible apron 1m thick comprising of loose stone boulders weighing not less then25 kg beyond curtain wall
12.7
-
-
... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
66.59
-
-
... More
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed.
a) 30 cm dia. RCC guard post with reinforcement of 6nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
20
-
-
... More
Construction of temporary Bamboo bridge of 3.70m clear road way with Bholuka or Barua Bamboo post 5nos. in each rows driven at least180cm. below ground level and rows not more than 150cm apart from center to center Bholuka or Barua Bamboo dham longitudinal groth both closely placed and tied with half bamboo 90cm to 120cm apart in both layers and ttwo layers of jati bamboo chattais ( top layer should be digonally woven), 70 mm to 100 mm thick brushwood in between chattias should be tied with half jati bamboo on both ends, bamboo railing with bholuka or barua bamboo post placed at150cm apart jati or betua bamboo hand rails of two lines both side of every alternate rows.All tying must be done with cane or coir string and only mature bamboo should be used in work.
5
-
-
... More
P.C.C. M15 ordinary grade(1:2:5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211 .
A) With crushed stone
(i) Nominal mix (1:2.5:5)
4.86
-
-
... More
Reinforced Cement Concrete M25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 . (A ) With crushed stone
9.72
-
-
... More
(D) Construction of RCC Box Cell Culvert : L -6.00 m, 1 No.
Size : 2.00m x 2.00m, 1 Cell
Rate as per Annx -
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
i) Ordinary soil
(i) Upto 3 m depth
60.64
-
-
... More
Sand Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9
5.18
-
-
... More
PCC 1:3:6 in foundation Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed Stone
i) P.C.C grade M 10
(i)Nominal mix 1:3:6
1.58
-
-
... More
PCC 1:2:4 in foundation, Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed Stone
iii) PCC Grade M20
(i) Nominal Mix 1:2:4
2.48
-
-
... More
Plain/reinforced cement concrete in sub-structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
A. With Crushed Stone
iv) RCC GRADE M25
(i) Height up to 5m
14.25
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
A. With crushed stone
(iv) RCC GRADE M25
(i) Height up to 5m
5.76
-
-
... More
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 .
1.15
-
-
... More
Supplying, fitting and placing TMTTMT (Fe-500D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
0.46
-
-
... More
Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
B.With Natural Gravel
1.29
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
4
-
-
... More
Back filling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
A. Grangular Materials
41.4
-
-
... More
Providing and laying curtain walls complete as per drawing and technical specification Clause 1304
iii) Cement concrete grade M10
7.03
-
-
... More
Construction of flexible apron 1m thick comprising of loose stone boulders weighing not less then 25 kg beyond curtain wall.
19.5
-
-
... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 .
14.1
-
-
... More
(E) Construction of RCC Box Cell Culvert : L - 7 . 50 m, 1 No.
Size : 1. 00m x 1.00m, 1 Cell
Rate as per Annx -
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
I. Ordinary soil
(i) Upto 3 m depth
25.45
-
-
... More
Sand Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9
3.11
-
-
... More
PCC 1:3:6 in foundation Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed Stone
i) P.C.C grade M 10
(i) Nominal mix 1:3:6
0.91
-
-
... More
PCC 1:2:4 in foundation Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed Stone
iii) PCC Grade M20
(i) Nominal mix 1:2:4
1.49
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
A. With Crushed Stone
IV. RCC GRADE M25
(i) Height up to 5m
7.91
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
A. With crushed stone
(ii) RCC GRADE M25
(a) Height up to 5m
3.52
-
-
... More
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
0.72
-
-
... More
Supplying, fitting and placing TMTTMT (Fe-500D) reinforcement bar . (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
0.32
-
-
... More
Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3 A. With crushed stone
0.78
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
4
-
-
... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
A. Grangular Materials
15.53
-
-
... More
Providing and laying curtain walls complete as per drawing and technical specification Clause 1304
iii) Cement concrete grade M10
5.91
-
-
... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
8.42
-
-
... More
(F) Construction of RCC Box Cell Culvert : L - 6.00 m, 4 Nos.
Size : 1.00m x 1.00m, 1 Cell
Rate as per Annx -
Earth work in excavation of foundation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
I. Ordinary soil
(i) Upto 3.00 m depth
100.88
-
-
... More
Sand Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9
9.72
-
-
... More
PCC 1:3:6 in foundation Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed Stone
i) P.C.C grade M 10
(i) Nominal mix 1:3:6
4.8
-
-
... More
PCC 1:2:4 in Foundation Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed Stone
iii) PCC Grade M20
(i) Nomonal Mix 1:2:4
5.04
-
-
... More
Plain/reinforced cement concrete in sub-structure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
A. With Crushed Stone
IV. RCC GRADE M25
(i) Height up to 5m
26.24
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
A. With crushed stone
(ii) RCC GRADE M25
(a) Height up to 5m
11.7
-
-
... More
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
2.37
-
-
... More
Supplying, fitting and placing TMTTMT (Fe-500D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
1.02
-
-
... More
Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
A. With crushed stone
2.43
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
16
-
-
... More
Back filling behind abutment, wing wall and return wall complete as per drawings and technical specification Clause 1204.3.8
A. Grangular Materials
48.6
-
-
... More
Providing and laying curtain walls complete as per drawing and technical specification Clause 1304.
iii) Cement concrete grade M10
23.64
-
-
... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 .
33.68
-
-
... More
Planting of Trees and their Maintenance for one Year (Planting of trees and their Maintenance for three year ( Planting of three by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trenches, watering , fixing the tree guatrd and maintaining the plants for three year.
Rate as per SOR Rural roads -2020-21 .)
160
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements