Bodoland Territorial Council Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 99,996Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Construction Of College Building Of Dimakuchi College, Dimakuchi In Udalguri Dist. (tn_94_1)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BTC_37444_1Bid Award Id
ViewTender No
ACE-35/TECH/UDL(RB)/IFB/18-19Tender Authority
Bodoland Territorial Council ViewPurchaser Address
-Website
http://https://www.bodoland.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6. Thermo-Mechanically Treated bars of grade Fe-500D or more.
4611.44
-
-
5.22A. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6. Thermo-Mechanically Treated bars of grade Fe-500D or more.
8616.34
-
-
5.22A. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.1. Mild steel and Medium Tensile steel bars
49.61
-
-
5.9. Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.1. Foundations, footings, bases of columns, etc. for mass concrete
112.14
-
-
5.9.6. Columns, Pillars, Piers, Abutments, Posts and Struts
102.9
-
-
5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers
181.91
-
-
5.9.3. Suspended floors, roofs, landings, balconies and access platform
262.1
-
-
5.9.7. Stairs, (excluding landings) except spiral staircases
9.19
-
-
5.1. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement All work up to plinth level: 5.1.2. 1:1.5:3 (1 cement 15 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
55.19
-
-
5.2. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2. 1:1.5:3 (1 cement: 1.5 coarse sand(zone III): 3 graded stone aggregate 20 mm nominal size)
9
-
-
5.3. Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
45.76
-
-
6.1. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1. Cement mortar 14 (1 cement 4 coarse sand)
21.31
-
-
6.13. Half brick masonry with common burnt clay EP.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2. Cement mortar 1:4 (1 cement :4 coarse sand)
208.5
-
-
9.1. Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.1 Second class teak wood
0.12
-
-
9.20. Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply vencering with vertical grains or cross bands and face veneers on both faces of shutters. 9.20.1. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary Screws
6.3
-
-
10.15. Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 10.15.1. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Window & Ventilation Frame 125mm x 60mm
679.86
-
-
10.30. Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 10.30.1. 4.0 mm thick glass panes
13.05
-
-
13.4. 12 mm cement plaster of mix: 13.4.2. 1:6 (1 cement: 6 coarse sand)
500.6
-
-
13.5. 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.2. 1:6 (1 cement: 6 coarse sand)
238.72
-
-
9.48. Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding.
346.95
-
-
2.25(a). Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
189.65
-
-
2.35. Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion): 2.35.3. Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor: 2.35.3.1. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
210.72
-
-
11.8. 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:24 (1 cement 2 coarse sand 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed 4 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
210.72
-
-
13.8. Cement plaster 13 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
11.0.1. 12 mm cement plaster
72.05
-
-
4.17. Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone ) 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
55.62
-
-
13.26. Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to 13.26 prepare the surface even and smooth complete.
543.79
-
-
13.41. Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade 11.41.1. New work (two or more coats) over and including water thinnable priming coat with cement primer
543.79
-
-
13.43. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface 11.41.1. Water thinnable cement primer
138.8
-
-
13.44. Finishing walls with water proofing cement paint of required shade: 11.44.1. New work (Two or more coats applied @ 3.84 kg/10 sqm)
138.8
-
-
13.62. Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. 11.52.1. On steel work
23.3
-
-
9.96. Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete: 9.96.2. 250x16 mm
2
-
-
9.97. Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 9.97.2. 250x10 mm
4
-
-
9.100. Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade 100 AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: 9.100.1. 125 mm
4
-
-
PLANTATION
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20%: 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) 2.14.1. Holes 1.2 m dia and 1.2 m deep
8
-
-
2.15. Half brick circular tree guard in bricks, internal diameter 1.25 metre and height 1.2 metre above ground and 0.20 m below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses being in dry honey comb masonry as per design complete: 2.15.1. With common burnt clay F.P.S. (non modular) bricks of class designation 5.0
8
-
-
7.5. Providing and stacking of Azadirachta indica (Neem) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
2
-
-
7.7. Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
2
-
-
7.24. Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v
2
-
-
7.74. Providing and stacking of Polyalthia longifolia (Ashok) of height 150-165 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.
2
-
-
EARTH FILLING
2.25(a) Excavationg, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trences, plinth, side of foundation etc. complete.
618.09
-
-
ELECTRICAL WORK
1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.1 Group A
18
-
-
1.10.2 Group B
16
-
-
1.10.3 Group C
4
-
-
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
180
-
-
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
90
-
-
1.14.5 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
45
-
-
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as 1.24.1 5/6 A switch
10
-
-
1.23.4 3 pin 5/6 A socket outlet
10
-
-
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
14
-
-
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1.27.4 6 Module (200mmX75mm)
2
-
-
1.27.5 8 Module (125mmX125mm)
4
-
-
1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.4 6 Module
2
-
-
1.28.5 8 Module
4
-
-
1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
87
-
-
1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required.
110
-
-
1.48 Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored).
14
-
-
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus 2.3.2. 8 way, Double door
1
-
-
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole
6
-
-
2.10.3 Double pole
1
-
-
2.12 Supplying and fixing following rating, double pole, 240 V. isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1 40 A
1
-
-
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1
-
-
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
19.25
-
-
12.34 Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
2
-
-
7.1 Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1 Upto 35 sq. mm
26
-
-
MR-1 Supplying with including fitting fixing of Ceiling fan (1400 mm) etc. as directed by the Deptt.
14
-
-
MR-2 Supplying with including fitting fixing of ADORE LED PLUS 9 W/10 W. etc. as required & directed by the Deptt.
2
-
-
MR-3 Supplying including fitting fixing of 18 W Slim LED batten with polycarbonate round-shape diffuser. Grey end cap, housing is an ideal replacement solution for existing battens fluorescent lamps with elegantly designed end caps etc. as required and directed by the Deptt.
18
-
-
MR-4 Supplying with fitting & fixing of highly effective front openable 45W IP66 Street light/Campus light with aluminium pressure dia-cost housing, toughened glass in the front and peanut lens for batwing light distribution to ensure uniform light distribution, higher spacing between poles and maintenance free system etc. as required and as directed by the Department (Orient, Bajaj, Havells or equivalent make).
2
-
-
MR-5 Supplying, installation with fitting & fixing of LUMINOUS UPS system including UPS Battery Trolley (LUMINOUS Inverter Sine Wave, Model No. ECO VOLT+ 1650 and Tall Tubulat Battery-150 Ah Model No. PC18042) as required and directed by the department.
1
-
-
MR-6 Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminum conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminum wire for single core up to 70 sq. mm, balance Aluminum strip, Glavanised wire for cables up to 2 x 10 sq. mm, 3 x 10 sq. mm, 4 x 6 sq. mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR, or equivalent make as approved by this Deptt.) Considering 100 Mtr. length). 10.00 sq.mm 2 Core U.G. Cable.
30
-
-
MR-7 Load security charge paybale to APDCL for up- gradation of electrical required Load as required and as directed by the deptt. (For 2 KW Load).
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements