Bodoland Territorial Council Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 50,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BoTC_40722_1Bid Award Id
ViewTender No
No. EE(Agri)/Koj/BTC/ e-Tender/2024-25/2134, dtd. 26/11/2024Tender Authority
Bodoland Territorial Council ViewPurchaser Address
-Website
http://https://www.bodoland.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
6.44
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars
1215.84
-
-
... More
Steel reinforcement for R... Work inluding sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.6. TMT bar Fe500D or more.
Mild steel and Medium Tensile steel bars
1517.94
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for :
5.9.1Foundations, footings, bases of columns, etc. for mass concrete
44.64
-
-
... More
Columns, Pillars, Posts & Strut
64.8
-
-
... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers
75.33
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
10.75
-
-
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
4.86
-
-
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
6.94
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
10.54
-
-
... More
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
8.25
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
27.31
-
-
... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
8.25
-
-
... More
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.
9.51.2 With 12 mm mild steel U beading
3.96
-
-
... More
15 mm cement plaster : 13.5.2 1:6 (1 cement : 6 coarse sand)
156.09
-
-
... More
20 mm cement plaster :
13.6.2 1:6 (1 cement : 6 coarse sand)
154.29
-
-
... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
9.48.1 Fixed to steel windows by welding
110
-
-
... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
2283.79
-
-
... More
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet
washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces),
excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
108.23
-
-
... More
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m²
13.7
-
-
... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
10.16.1 Hot finished welded type tubes
2223.75
-
-
... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete
Floor
62.59
-
-
... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONALanti-termite treatment (excluding the cost of chemical emulsion) : 2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2
(1 cement : 2 Coarse sand) to match the existing floor: 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Floor
69.85
-
-
... More
62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener
mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Floor
69.54
-
-
... More
Cement plaster (1:3) finished with a floating coat of neat cement.
13.9.1 12 mm Cement Plaster
38.98
-
-
... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Fixed to openings /wooden frames with rawl plugs screws etc.
37.26
-
-
... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
13.41.1 New work (two or more coats) over and including water
thinnable priming coat with cement primer
Wall
150.1
-
-
... More
Finishing walls with water proofing cement paint of required shade :
13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
Wall
178
-
-
... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.
13.52.1 On steel work
Chowkath
24.75
-
-
... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Rising Low Site
780.86
-
-
... More
ELECTRIFICATION WORKS Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.
(But without MCB/RCCB/Isolator)
12 way , Double door
1
-
-
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
4 way (4 + 12), Double door
1
-
-
... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
63A TP
1
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
5
-
-
... More
Double pole
1
-
-
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
1
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group-A
5
-
-
... More
Group-B
5
-
-
... More
Group-C
4
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
15
-
-
... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
25
-
-
... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
5
-
-
... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
10
-
-
... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
12
-
-
... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20 mm
20
-
-
... More
25 mm
15
-
-
... More
32 mm
25
-
-
... More
40 mm
12
-
-
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
40
-
-
... More
15/16 A switch
20
-
-
... More
3 pin 5/6 A socket outlet
15
-
-
... More
6 pin 15/16 A socket outlet
14
-
-
... More
Bell push (office RM)
2
-
-
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
21
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1 or 2 Module (75mm X 75mm)
12
-
-
... More
3 Module (100mmX75mm)
8
-
-
... More
6 Module (200mmX75mm)
20
-
-
... More
12 Module (200mmX150mm)
8
-
-
... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1 or 2 Module (75mm X 75mm)
15
-
-
... More
3 Module
9
-
-
... More
6 Module
20
-
-
... More
12 Module
8
-
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
4
-
-
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
2
-
-
... More
Wiring for group controlled (looped) light point/fan
point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group-C
4
-
-
... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, painting etc. as required.
2
-
-
... More
Supplying,Installation, Testing & Commissionng of following watts/type LED fitting with all accessories and lamps mounting on ceiling surface /false ceiling not less than 100lumens/watt,Min-50000 burning hours,LM79 report,THD less than 20% including making suitable cutting on false ceiling (where ever required),connection with 1.5 sq. mm. FRLS PVC insulated copper conductor single core FR type cable as required.
6 Watt Surface type PDC Aluminium housing
5
-
-
... More
20 Watt TubeLight Point
10
-
-
... More
MASONARY DRAIN (Surrounding the Building)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
11.66
-
-
... More
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :
(a).Brick on flat soling.
25.92
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1.94
-
-
... More
Brickwork with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
4.37
-
-
... More
12 mm cement plastering of mix: 13.4.2 1:6 (1 cement :6 coarse sand )
Foundations, footings, bases for columns
58.73
-
-
... More
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
13.9.1 12 mm cement plaster
58.73
-
-
Evaluation Notes How It Works ?
Potential Partner