Bodoland Territorial Council Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,05,733Document Cost
₹ 1,100Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BTC_40035_1Tender No
38/KOK/R/IFB/Pt.II/23-24/29Tender Authority
Bodoland Territorial Council ViewPurchaser Address
-Website
http://https://www.bodoland.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
3.14.i Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private land
41.98
-
-
Construction of RCC Retaining wall
11.1 Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bractng, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material I. Ordinary soil
(i) Upto 3 m depth
1326
-
-
11.4 Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
A. With crushed stone
I. P.C.C grade M 10 Nominal mix 1:3:6
68
-
-
12.6 Supplying, fitting and placing TMT (Fe-500 D) bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RlNL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005 1010 & 1202
Surface reinforcement
Wall with base-12mm dia main bar 150mm c/c Wall with base-amm dia binder 200mm c/c
2.6
-
-
12.9 Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of I(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
180
-
-
12.5 Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 1202 and 1204 :: (B) With natural gravel (iii) RCC Grade M 20 :: (i) For height upto 5m
450.84
-
-
10.2.A.2.v Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 1.5 mm thick supported on GI pipe 50 mm dia firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 1701. (v) 60cm x 45cm rectangular
1
-
-
16.60 Planting of Trees and their Maintenance for three Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trenches, watering , fixing the tree guatrd and maintaining the plants for three year.
6
-
-
Construction of RCC Box cell Culvert 11.1 Earth work in excavation for structure as per drawing and technical specification clause 305.1, including setting out, construction of shoring and bracing, removal of stumps and other deleterious meterial and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
I. Ordinary Soil
(i) Upto 3.00m depth.
41.6
-
-
11.2 Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9
I. Sand filling
9.83
-
-
11.4 Providing concrete plain/reiforced concrete in open foundation complete as per drawing and technical specification clauses 802, 803, 1202 & 1203.
B. With Natural gravel
(II) PCC Grade M15
(i) Nominal mix 1:2.5:5
5.77
-
-
12.5 Plain/ Reinforced cement concrete in sub stucture complete as per drawing and technical specification clauses 802, 804, 805, 807 and 1204.
B. With Natural Gravel
III. RCC Grade M20
(i) For height upto 5m
31.88
-
-
13.1 Providing and laying reinforced cement concrete in super structure as per drawing and technical specification clauses 800, 1205.4 and 1205.5
B. With Natural Gravel
I. RCC Grade M20 (i) Nominal Mix 1:2:4 (a) Height upto 5m
15.16
-
-
12.6 Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer: TATA/ SAIL/ Esser Steel/ Jindal Steel/ Shyam Steel/ RINL) in substructure complete as per drawing and technical specification clauses 1002, 1005, 1010 & 1202.
2.33
-
-
13.2 Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer: TATA/ SAIL/ Esser Steel/ Jindal Steel/ Shyam Steel/ RINL) in superstructure complete as per drawing and technical specification clause 1002, 1010 and 1202.
1.27
-
-
13.6 Construction of RCC railing of M25 grade, in-situ with 20mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical posts not to exceed 2000mm, as per approved drawings and Technical Specification Clauses 800, 900 and 1208.3
21.5
-
-
13.5 Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specification clauses 800 and 1206.3
2.28
-
-
12.9 Providing weep hole in brick masonry/ plain/ reinforced concrete abutment, wing wall/ return wall with 100mm dia AC pipe extending through the full width of the structure with slope 1v: 20H towards drawing force complete as per drawing and Technical Specification Clauses 614, 709, 1204.3.7
26
-
-
12.10 Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification Clause 1204.3.8
(ii) Sandy material.
52.44
-
-