Bodoland Territorial Council Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,64,000Document Cost
₹ 1,650Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BoTC_40449_1Bid Award Id
ViewTender No
No. TECH- 40/SE(RB)/E-TenderTender Authority
Bodoland Territorial Council ViewPurchaser Address
-Website
http://https://www.bodoland.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Construction of Sub grade and Earthen shoulders with approved materials obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with a lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land
896.97
-
-
... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.
(ii) For Grading II Material.
401.63
-
-
... More
Water Bound Macadam : Providing, laying, spreading and compacting stone aggregates of specific size to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.
(A) By Manual Means (III) WBM Grading-III
200.81
-
-
... More
ICBP : Providing and laying interlocking concrete block pavement with M40 grade grade of concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage.
a) Including Edge block/ Edge restraints
2760.98
-
-
... More
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801
(ii) 600mm equilateral triangle
2
-
-
... More
(iii) 600 mm Circular
2
-
-
... More
Kilometer Stone :
Reinforced cement concerete M15 grade kilometer stone/local stone of standard design as per IRC : 8 fixing in position including painting and printing etc. as per drawing and technical specification clauses 1703.
(ii) Ordinary Kilometer Stone (Precast)
1
-
-
... More
iii) 200 meter Stone (Precast)
3
-
-
... More
Providing and fixing typical PMGSY informatory sign board with logo as per MORD Specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of the lower most plate and flat iron frame of middleplate will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm below ground level. The top most diamond plate will be welded to middleplate by 47mm x 47mm of 12 SWG steel plate tube. All M.S will be stoveenameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
-
... More
RCC Guard Post :
Supplying, fitting and fixing RCC Guard Post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade of cement concrete and required reinforcement tied in position with annealed black wire including centering moulding the top curing including painting concrete surface in 23 cm strips upto 0.75 m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per designed i) 30 cm dia RCC guard post with reinforcement of 6 nos. 12mm dia TMT main steel bars and 6mm TMT/MS stirrup at 15 cm c/c.
40
-
-
... More
RCC Box Culvert 3.00 m X 3.00 m, 2 Cell- 1 No. :
Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shorting and bracing removal of stumps and other deleterious material and disposal up to laed of 50m, dressing of sides and bottom and back filling in trenches with excavated suitable material.
i) In Ordinary Soil (ii) Up to 3.00 m depth
113.41
-
-
... More
Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9
(i) Sand filling
72.66
-
-
... More
Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification clause 802
(i) PCC grade M-10
16.12
-
-
... More
Plain/Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttering form work as per clause 802,804,805,806,807,1202 and 1204
B. With natural Gravel IV. RCC M-25 Grade (i) Height upto 5.00m
69.37
-
-
... More
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer : TATA/SAIL/Essar Steel/Jindal Steel/Shyam Steel/RINL) in sub-structure complete as per drawing and technical specification clauses 1002,1005,1010 & 1202
4.72
-
-
... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications clauses 800 and 1206.3
3.57
-
-
... More
Drainage spouts complete as per drawing and technical specifications Clause 120.9
4
-
-
... More
Construction of RCC Railing of M30 Grade in situ with 20mm nominal size aggregate, true to line and grade, tolerance of vertical RCC Post not to exceede 1 in 500, center to center soacing betwwen vertical post not to exceed 2000mm, as per drawing and technical specification clause 800,900 & 1208.3
26.2
-
-
... More
Providing and laying filter materials underneath pitching in slopes complete as per drawing and technical specification.
7.5
-
-
... More
Providing and laying pitching on slopes laid over prepared media as per drawing and technical specification, clause 1302.
(1) Stone/Boulder
51.9
-
-
... More
Providing and laying boulder apron lead in wire crates made width 4 mm dia GI wire conforming to IS : 280 & IS : 4836 IN 100mm x 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone boulder weighing not less than 25kg each as per drawing and technical specification clause 1301.
132
-
-
... More
RCC Box Culvert 1.00 m X 1.00 m, 2 Nos. :
Earth work in excavation for structures as per drawing and technical specifications, including setting out, construction of shorting and bracing removal of stumps and other deleterious material and disposal up to laed of 50m, dressing of sides and bottom and back filling in trenches with excavated suitable material.
i) In Ordinary Soil (ii) Up to 3.00 m depth
28.64
-
-
... More
Providing concrete for plain/reinforced concrete in open foundation complete as per drawing and technical specification clause 802,803,1202 & 1203
3.44
-
-
... More
Plain/Reinforced cement concrete, in substructure complete as per drawing and Technical Specification and steel shuttering form work as per clause 802,804,805,806,807,1202 and 1204
B. With natural Gravel IV. RCC M-20 Grade (i) Height upto 5.00m
31.88
-
-
... More
Supplying, fitting and placing TMT (Fe-500D) reinforcement bar (From Primary Producer : TATA/SAIL/Essar Steel/Jindal Steel/Shyam Steel/RINL) in sub-structure complete as per drawing and technical specification clauses 1002,1005,1010 & 1202
2.94
-
-
... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications clauses 800 and 1206.3
1.5
-
-
... More
Providing and laying boulder apron lead in wire crates made width 4 mm dia GI wire conforming to IS : 280 & IS : 4836 IN 100mm x 100mm mesh (Woven diagonally) including 10 percent extra for laps and joints laid with stone boulder weighing not less than 25kg each as per drawing and technical specification clause 1301.
7.2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements