Bodoland Territorial Council Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Bodoland Territorial Council - BTC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date22 Mar 2024
Closing Date30 Mar 2024
Tender Amount₹ 1,49,81,000 
Notes
Download

Costs

Summary

Construction Of Mini Cinema Hall (100 Seater) At Rowta, Udalguri Under Grants To Btc For Infrastructure Development Fund For The Year 2023-24. (tn_90_28)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
4.1. Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources)

53.8

-

-

... More
4.17. Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

59.63

-

-

... More
REINFORCED CEMENT CONCRETE 5.1. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement All work up to plinth level 5.1.2. 1:15:3 (1 cement : 1.5 coarse sand (zone-fil) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).

98.79

-

-

... More
5.2. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2. 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)

16.96

-

-

... More
5.3. Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).

75.98

-

-

... More
FROM WORK 5.9. Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1. Foundations, footings, bases of columns, etc. for mass concrete.

75.96

-

-

... More
5.9.3. Suspended floors, roofs, landings, balconies and access platform.

421.16

-

-

... More
5.9.21. Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick

399.96

-

-

... More
5.9.6. Columns, Pillars, Piers, Abutments, Posts and Struts

273.44

-

-

... More
5.9.7. Stairs,(excluding landings) except spiral- staircases

20.47

-

-

... More
5.9.19. Weather shade, Chajjas, Corbels etc., including edges

3.78

-

-

... More
STEEL REINFORCEMENT 5.22. Steel reinforcement for R.C.C. work including straightening cutting bending placing in position and binding all complete upto plinth level 5.22.6. Thermo- Mechanically Treated bars of grade Fe- 500D or more

8129.43

-

-

... More
5.22.A Steel reinforcement for R.C.C. work including straightening cutting bending placing in position and binding all complete upto plinth level 5.22A.6. Thermo- Mechanically Treated bars of grade Fe- 500D or more

13593.18

-

-

... More
16.12. Dry brick pitching half brick thick in drains including supply of brides and preparing the surface complete: 16.12.1. (a) Brick on flat soling

426.06

-

-

... More
MASONRY WORK 6.1. Brick work with common burnt day FPS. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1. Cement mortar 1:4 (1 cement: 4 coarse sand)

34.74

-

-

... More
HALF BRICK MASONRY 6.13. Half brick masonry with common burnt day F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level 6.13.1. Cement mortar 13 (1 cement 3 coarse sand)

461.16

-

-

... More
26.86. Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Crosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of SS N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In-Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately) 26.86.6 Frame size 65 x 125 mm

56.4

-

-

... More
26.87. Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S.S Iscrews shall be paid separately) 26.87.1 30 mm thick

21.42

-

-

... More
21.10. Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.

5.45

-

-

... More
9.15. Providing and fixing zinc alloyed (white powder coated) touch lock for uPVC sliding window with necessary screws etc. complete.

15

-

-

... More
9.48. Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all 9.48.2. Providing and fixing M.S. grills of required pattern in frames of windows etc.

92.63

-

-

... More
FLOORING 11.5. 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry but excluding the cost of nosing of steps etc. complete.

139.88

-

-

... More
VITRIFIED FLOOR TILES 11.41A. Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.3. Glazed Vitrified tiles Matt/Antiskid finish of size 11.41A.3.1. Size of Tile 600 x 600 mm

83.17

-

-

... More
8.31. Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

37.48

-

-

... More
11.20. Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc complete, en 20 mm thick bed of cement mortar 14 (1 cement & coarse sand) 11.201 Light shade pigment using white cement

54.18

-

-

... More
CEMENT PLASTER (IN COARSE SAND) 13.1. 12 min cement plaster of mis 13.1.1. 1:4 (1 cement: 4 fine sand)

225.74

-

-

... More
13.2. 15 mm cement plaster on the rough side of single or half brick wall of mix: 13.2.1. 1:4 (1 cement: 4 fine sand)

981.52

-

-

... More
13.46. Finishing walls with Acrylic Smooth exterior paint of required shade: 13.46.1. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1207.26

-

-

... More
13.48.3. Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture

10.89

-

-

... More
9.92. Providing and fixing chromium plated brass handles with necessary screws etc. complete: 9.92.1. 125 mm

22

-

-

... More
9.97. Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 9.97.4. 150x10 mm

22

-

-

... More
9.64. Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS: 7534 with necessary screws bolts, nut and washers etc. complete.

22

-

-

... More
21.18. Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality) for aluminium doors including necessary cutting and making good etc complete

4

-

-

... More
10.28. Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

10.8

-

-

... More
8.2. Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.2.2. Granite stone slab colour black, Cherry/Ruby red 8.2.2.1. Area of slab upto 0.50 sqm

1.08

-

-

... More
5.17. Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in vertical & horizontal fins, individually or forming box louvers, setting in cement mortar 1:2 (1 cement : 2 coarse sand), including the cost of required centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).

1.47

-

-

... More
12.41. Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. 12.41.2. 110 mm diameter

34.4

-

-

... More
12.1. Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limp washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters a trusses and including cutting to size and shape wherever required. 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/m²

192.97

-

-

... More
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.3 Electric resistance or induction butt welded tubes

3333.38

-

-

... More
10.6. Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover

7.2

-

-

... More
10.7. Providing and fixing ball bearing for rolling shutters.

4

-

-

... More
26.23. Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile, rotary stiched double webbed white with 6mm reveal profile (white/black), comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross- T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- 26.23.1. With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles

161.47

-

-

... More
26.24. Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) a per 15 8225 1987, Light reflectance of 85% (minimum). Non combustible as per BS-476 (part-4), fire performance as per BS.476 (part 6 & 7), humidity resistance of 100%, thermal conductivity 0.043 W/mK as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) Le vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia, 50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horizontal direction at 600mm center to center so as to form a grid of 600mmx 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of 26.24.1. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/tiles

206.12

-

-

... More
SANITARY WORKS 17.3. Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 17.3.1. W.C. pan with ISI marked white solid plastic seat and lid

2

-

-

... More
17.5. Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: 17.5.1. Single half stall urinal with 5 litre P.V.C. automatic flushing cistern

2

-

-

... More
17.6. Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I./ PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required: 17.6.1. Single squatting plate with 5 litre P.V.C. automatic flushing cistern

2

-

-

... More
17.7. Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

2

-

-

... More
17.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.

2

-

-

... More
17.16A Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

4

-

-

... More
17.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

4

-

-

... More
17.29 Providing and fixing 100 mm sand cast Iron grating for gully trap.

4

-

-

... More
17.35. Providing and fixing soil, waste and vent pipes : 17.35.1 100 mm dia 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729

46

-

-

... More
17.36. Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) in S.C.I./ C.I. Pipes 17.36.2. 100 mm dia pipe

16

-

-

... More
17.37. Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 17.37.1. For 100 mm dia pipe

16

-

-

... More
17.38. Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 17.38.1 100 mm dia 17.38.1.2 Sand cast iron S&S as per IS-3989

8

-

-

... More
17.61. Cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement: 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement: 4 coarse sand): 17.61.1. 100 mm dia

5

-

-

... More
17.69.1. Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms

2

-

-

... More
17.73. Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

2

-

-

... More
17.74 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms.

2

-

-

... More
100 USERS SEPTIC TANK 2.6. Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1. All kinds of soil

33.38

-

-

... More
16.12. Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete: 16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

8.67

-

-

... More
4.1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 4.1.3. 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources)

1.24

-

-

... More
4.1.5. 1:3:6 (1 Cement: 3 coarse sand (zone-III) derived from natural Sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources)

1.3

-

-

... More
4.3. Centering and shuttering including strutting, propping etc. and removal of form work for: 4.3.1. Foundations, footings, bases for columns

2.04

-

-

... More
5.1. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.2. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)

0.08

-

-

... More
5.9. Centering and shuttering including strutting, propping etc. and removal of form for 5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers.

0.56

-

-

... More
5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.6. Thermo-Mechanically Treated bars of grade Fe-5000 or more.

56.09

-

-

... More
6.1. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1. Cement mortar 1:4 (1 cement : 4 coarse sand)

5.69

-

-

... More
6.12. Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in: 6.12.1. Cement mortar 1:3 (1 cement: 3 coarse sand)

3.18

-

-

... More
13.8. 13.8. 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 13.8.1. 1:3 (1 cement: 3 fine sand)

20.91

-

-

... More
5.12. Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but, excluding cost of reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).

0.63

-

-

... More
19.18. Supplying and fixing C.I. cover without frame for manholes : 19.18.2. 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg

2

-

-

... More
19.30. Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement: 1.5 fine sand: 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: 19.30.1. Inside dimensions 455x610 mm and 45 cm deep for single pipe line 19.30.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

1

-

-

... More
19.33. Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.

1

-

-

... More
17.35. 17.35 Providing and fixing soil, waste and vent pipes: 17.35.1. 100 mm dia 17.35.1.1. Sand cast iron S&S pipe as per IS: 1729

4

-

-

... More
17.36. Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 (1 cement: 2 fine sand) in S.C.I./ C.I. Pipes 17.36.2. 100 mm dia pipe

2

-

-

... More
WATER SUPPLY (PLUMBING) 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including allCPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work Exposed on wall 18.7.1 15 mm nominal dia Pipes

7

-

-

... More
18.7.2 20 mm nominal dia Pipes

14

-

-

... More
18.7.6 50 mm nominal dia Pipes

12

-

-

... More
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.1 15 mm nominal dia Pipes

20

-

-

... More
18.8.2. 20 mm nominal dia Pipes

14

-

-

... More
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.2 20 mm nominal dia Pipes

20

-

-

... More
18.9.3. 25 mm nominal dia Pipes

30

-

-

... More
18.9.9. 100 mm nominal dia Pipes

15

-

-

... More
BRASS FITTINGS 18.15 Providing and fixing brass bib cock of approved quality: 18.15.1 15 mm nominal bore

10

-

-

... More
18.16. Providing and fixing brass stop cock of approved quality: 18.16.1. 15 mm nominal bore

10

-

-

... More
18.20 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 18.20.1. 15 mm nominal bore

6

-

-

... More
18.51. Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.

3

-

-

... More
18.48. Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

-

-

... More
Deep Tube Well 23.1. Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samp from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.2. Rocky strata including Boulders 23.1.2.1. 300 mm dia

50

-

-

... More
23.3. Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.3.2. 150 mm nominal size dia

50

-

-

... More
23.8. Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

2

-

-

... More
23.12. Development of tube well in accordance with IS: 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content. (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw. down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

24

-

-

... More
23.15 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per 15:2800 (part 1). 23.15.2. 150 mm dia

1

-

-

... More
18.43. Providing and placing in position filters of 40 mm diameter G.1. pipe with brass strainer of approved quality.

2

-

-

... More
18.46. Providing and fixing G.1. Union in G.1. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 18.46.5. 40 mm nominal bore

2

-

-

... More
18.9. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 18.9.5. 40 mm nominal dia Pipes

48

-

-

... More
18.19.Providing and fixing gun metal non- return valve of approved quality (screwed end): 18.19.3. 40 mm nominal bore 18.19.3.2 Vertical

1

-

-

... More
Const. of Boundary Fencing 2.6. Earth work in excavation by mechanical means (Hydraulic excavator) manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 2.6.1. All kinds of soil

11.77

-

-

... More
4.1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 4.1.6. 1:3:6 (1 Cement: 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources)

11.77

-

-

... More
4.3. Centering and shuttering including strutting, propping etc. and removal of form work for 4.3.1 Foundations, footings, bases for columns

104.58

-

-

... More
16.15 R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement: 1.5 coarsesand: 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-incharge (cost of earth works in excavation, concrete works in foundation to be paid separately).

3.92

-

-

... More
16.17. Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. 16.17.1 With G.I. barbed wire

1586

-

-

... More
LANDSCAPING 3.1. Providing and displaying of Aglaonema Butterfly having ht.30 cm 10 to 12 fresh, healthy and attractive colorful leaves, well developed in 25 cm size Earthen pot/Plastic pot & as per direction of the officer-in-charge.

10

-

-

... More
3.6. Providing and Displaying of Aglaonema Sam plant ht.30 cm well developed three in one, having 18 to 20 fresh, healthy and attractive colorful leaves in 35 cm size Earthen pot/Chali/Tray & as per direction of the officer-in-charge.

10

-

-

... More
3.17. Providing and displaying of Araucaria cookie having ht. 1.80 m to 1.95 m, straight, well developed, fresh and healthy with lush green leaves from bottom to top in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

14

-

-

... More
3.22. Providing and displaying of Areca Palm having ht. 2.40 m to 2.70 m with 12 to 14 suckers, well developed, fresh and healthy with lush green foliage in 35 cm size of Bucket type cement pots & as per direction of the officer- in-charge.

10

-

-

... More
3.35. Providing and displaying of Croton Duck Foot (Elite) having ht. 60 cm to 75 cm with 4 to 5 branches, well developed, fresh and healthy colorful leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

10

-

-

... More
3.39. Providing and displaying of Croton Petra Bangalore (Specimen) variety having ht. 60 cm to 75 cm with 4 to 6 branches, well developed, fresh & healthy foliage approximately 60-65 leaves in 30 cm size of Earthen pot/ Plastic pot & as per direction of the officer-in-charge.

10

-

-

... More
3.64 Providing and displaying of Philodendron Envy mounted on moss stick 90 cm ht., well developed with full of fresh & healthy leaves in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

10

-

-

... More
5.6. Providing and Displaying Adenium Obesum well developed with fresh & healthy 4 to 5 branch 60 to 75 cm ht. in 40 cm size Earthen Pot/Plastic Pot as per direction of the officer-in-charge.

10

-

-

... More
5.7. Providing and Displaying Bamboo Buddha Valley with fresh & healthy 5 to 6 suckers 1.80 m to 2.10m ht umbrella type well developed in 50 cm Cement Pot as per direction of the officer-in-charge.

10

-

-

... More
5.11. Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in- charge.

10

-

-

... More
5.13. Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction of the officer-in-charge.

10

-

-

... More
Fire Fighting 1.0 SAFEVERSE ABC Powder Type 6 kg (Stored Pressure) Fire Extinguisher, Multipurpose Uses Manufacture: PK ENTERPRISE

4

-

-

... More
2.0. Alfa CO2 fire extenguisher, 4.5 kg

4

-

-

... More
Construction of Approach Road 16.12. Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : 16.12.1.(a) Brick on flat soling.

120

-

-

... More
4.1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 4.1.3. 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources)

18

-

-

... More
4.3. Centering and shuttering including strutting, propping etc. and removal of form work for : 4.3.2Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.

13.91

-

-

... More
LAND DEVELOPMENT 2.25. Excavating, Supplying and filling of local earth ( including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth sides of foundation etc complete.

389.25

-

-

... More
ELECTRIFICATIONS 1.10. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.1. Group-A

18

-

-

... More
1.10.2. Group-B

12

-

-

... More
1.10.3. Group-C

15

-

-

... More
1.14. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper (Item No:-1.14) conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2. 2 X 2.5 sq. mm+1 X 2.5 sq. mm earth wire

225

-

-

... More
1.14.3. 2 X 4 sq. mm+1 X 4 sq. mm earth wire

140

-

-

... More
1.14.4. 2 X 6 sq. mm+1 X 6 sq. mm earth wire

30

-

-

... More
1.14.10. 4 X 10 sq. mm+2 X 6 sq. mm earth wire

10

-

-

... More
1.14.11. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire

30

-

-

... More
1.21. Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/reces including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1. 20 mm

180

-

-

... More
1.21.2. 25 mm

250

-

-

... More
1.21.3. 32 mm

30

-

-

... More
1.24. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1. 5/6 A switch

4

-

-

... More
1.24.4. 3 pin 5/6 A socket outlet

4

-

-

... More
1.31. Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

6

-

-

... More
1.32. Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

16

-

-

... More
1.50. Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1. Upto 450 mm sweep

5

-

-

... More
1.55. Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.55.1. Group-A

30

-

-

... More
1.55.2. Group-B

25

-

-

... More
1.55.3. Group-C

20

-

-

... More
2.3. Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.3. 12 way, Double door

1

-

-

... More
2.4. Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.4.1. 4 way (4+12), Double door

2

-

-

... More
2.10. Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1. Single pole

34

-

-

... More
2.10.3. Double pole

1

-

-

... More
2.15. Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.15.2. 40A

1

-

-

... More
2.15.3. 63A

1

-

-

... More
2.16. Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

2

-

-

... More
4.1. Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 4.1.4. 300 mm width X 50 mm depth X 1.6 mm thickness

42

-

-

... More
5.2. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

4

-

-

... More
5.6. Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ Icoke and salt as required.

2

-

-

... More
5.8. Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode. including connection/ terminating with nut, bolt, spring washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

40

-

-

... More
5.9. Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring. washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

120

-

-

... More
5.16. Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.

250

-

-

... More
5.20. Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

10

-

-

... More
6.2. Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long. G.1. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

4

-

-

... More
6.4. Jointing copper/G.I. tape (with another copper/GI tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

4

-

-

... More
6.7. Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)

100

-

-

... More
6.8. Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

100

-

-

... More
6.12. Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

4

-

-

... More
7.3. Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. 7.3.1. Upto 35 sq. mm

220

-

-

... More
7.3.2. Above 35 sq. mm and upto 95 sq. mm

85

-

-

... More
7.3.3. Above 95 sq. mm and upto 185 sq. mm

40

-

-

... More
7.7. Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required. 7.7.1. Upto 35 sq. mm (clamped with Imm thick saddle)

120

-

-

... More
7.7.2. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

45

-

-

... More
7.8. Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on cable tray as required. 7.8.1. Upto 35 sq. mm (clamped with Imm thick saddle)

70

-

-

... More
7.8.2. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

32

-

-

... More
9.1. Supplying and making end termination with brass compression gland and aluminium lugs for followin size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.21. 3 1/2 X 35 sq. mm (32mm)

10

-

-

... More
9.1.32. 4 X 10 sq. mm (45mm)

8

-

-

... More
9.1.33. 4 X 16 sq. mm (28mm)

4

-

-

... More
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 36kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in an enclosure and necessary connection. 1.0 100Amp 4P MCCB

2

-

-

... More
2.0. Enclosure for MCCB

2

-

-

... More
3.0. Supplying and fixing 415 V 100A Four Pole Auto Transfer Switch along with Controller.

1

-

-

... More
4.0. Supplying and fixing double door Vertical TPN Distribution board for MCCB incomer with IP-43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Legrand Make) (Up to 160A) 8 WAY VTPN DB

1

-

-

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBS and necessary connection 5.0. 63A TP

3

-

-

... More
6.0. 40A TP

2

-

-

... More
7.0. 32A TP

2

-

-

... More
8.0. 32A SP

3

-

-

... More
9.0. Supplying and fixing following rating, four pole, 415 volts, 63A residual current circuit breaker (RCCB). having a sensitivity current 300 mA in an Enclosure complete with connections, testing and commissioning etc, as required.

1

-

-

... More
10.0. Supplying and fixing following rating, four pole, 415 volts, 40A residual current circuit breaker (RCCB) having a sensitivity current 300 mA in an Enclosure complete with connections, testing and commissioning etc. as required.

1

-

-

... More
Supplying of XLPE AL/Cu, armoured cables as below: 11.0. 3.5Cx35 sq.mm. XLPE AI Arm. Multistranded Cable

200

-

-

... More
12.0. 4Cx16 sq. mm. XLPE Al. Arm. Multistranded Cable

50

-

-

... More
13.0. 4Cx10 sq. mm. XLPE AI. Arm. Multistranded Cable

60

-

-

... More
14.0. 3Cx10 sq. mm. XLPE AI. Arm. Multistranded Cable

170

-

-

... More
Supplying,Installation, Testing & Commissionng of following watts/type LED fitting with all accessories and lamps mounting on ceiling surface /false ceiling not less than 100lumens/watt,Min-50000 burning hours,LM79 report,THD less than 20% including making suitable cutting on false ceiling (where ever required),connection with 1.5 sq. mm. FRLS PVC insulated copper conductor single core FR type cable as required. 15.0. a 18 Watt Recess type Ceiling Light

26

-

-

... More
16.0. b. 7 Watt Step type Light

19

-

-

... More
17.0. c. 18 Watt Surface type Ceiling Light

8

-

-

... More
18.0. d. 12 Watt Surface type Ceiling Light

20

-

-

... More
19.0. e. Entry/ Exit Type Signage Light

6

-

-

... More
20.0. 90w Street / Outdoor Light

7

-

-

... More
21.0. Exhaust Fan -250 mm dia

5

-

-

... More
22.0.5kva Online UPS including Isolation transformer with 15 Minutes Battery Back up

1

-

-

... More
23.0. 40kva Silent Type Diesel Generator Set inbuilt with AMF Controller

1

-

-

... More
TELEPHONE & LAN SYSTEM:- 1.27. Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.1. 1 or 2 Module (75mmX75mm)

5

-

-

... More
1.24. Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.6. Telephone socket outlet

3

-

-

... More
1.27. Supplying and fixing following size/modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.18. Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/recessed steel/ PVC conduit as required. 1.18.2. 2 Pair

400

-

-

... More
14.16. Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 14.16.1.63 mm dia (OD-63 mm & ID-51 mm nominal)

100

-

-

... More
14.16.5. 200 mm dia (OD-200 mm & ID-175 mm nominal)

80

-

-

... More
24.0. Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. RJ-45 Socket Cat-6 with Shutter (Legrnad Make)

2

-

-

... More
CCTV SYSTEM IP Indoor type Dome Camera (Supply, Fixing & provisioning) 2MP Full-HD fixed 2.8-4 MM lens, CMOS, IP67, IK 10, PoE, WDR, 1920 x 1080@30fps, Upto 10-15 M IR Range.(Hikvision Make)

10

-

-

... More
IP Outdoor type Bullet Camera (Supply, Fixing & provisioning) 2MP Full-HD fixed 2.8-4 MM lens, CMOS, 1920x1080@30fps, WDR, IP67, PoE, Up to 30M IR range (Hikvision Make)

4

-

-

... More
16CH Entry Level DVR (16x1) (16 video, 1 Audio, CIF resolution, VGA,LAN, USB,Mouse, Mobile view supported (Hikvision Make)

1

-

-

... More
Supply, Fixing & provisioning of 6TB Surviellence HDD for recording (Segate Make)

1

-

-

... More
43" Commercial LED Pannel, HD display with Mounting Bracket

1

-

-

... More
Supplying and drawing of UTP 4 Pair CAT-6 Lan cable in the existing surfsce/recessed steel/PVC conduit as required. 1.53.1. 1 run of Cable

1400

-

-

... More
Supplying, installation, testing and commissioning of the 63 KVA, 11/0.433 KV, THREE PHASES, 50C/S ALUMINIUM WOUND DISTRIBUTION TRANSFORMERS WITH ALL ACCESSORIES AND WITH FIRST FILLING OF TRANSFORMER OIL IS AS BELOW.

1

-

-

... More
Supply fittings, fixing and erection of 6m long G.I. pole including foudation work as per Engineer i/c

7

-

-

... More
Supply and fittings of Single arm Bracket 1 mtr long 80x300+40x1500 as per Engineer i/c

5

-

-

... More
AIR-CONDITIONING SYSTEM

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.