Bodoland Territorial Council Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 50,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BTC_40331_1Bid Award Id
ViewTender No
No. ACE-106/PWD/IFB/PT-ITender Authority
Bodoland Territorial Council ViewPurchaser Address
-Website
http://https://www.bodoland.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
5.22.1 Mild steel and Medium Tensile steel bars
689.76
-
-
... More
5.22A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
5.22A.1 Mild steel and Medium Tensile steel bars
899.75
-
-
... More
5.9 Centering and shuttering including strutting, propping etc. and removal of form for
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
39.96
-
-
... More
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
35.64
-
-
... More
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
65.29
-
-
... More
5.9.3 Suspended floors, roofs, landings, balconies and access platform
6.82
-
-
... More
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
6.83
-
-
... More
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1.34
-
-
... More
5.3 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
2.96
-
-
... More
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
9.55
-
-
... More
6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
133.08
-
-
... More
9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
9.1.3 Kiln seasoned and chemically treated hollock wood
0.15
-
-
... More
9.5 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)
9.5.1 Second class teak wood
9.5.1.1 35 mm thick shutters
6.3
-
-
... More
10.15 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and
applying a priming coat of approved steel primer.
10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
876.66
-
-
... More
9.117 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin-charge
9.117.1 Extruded section profile size 48x40 mm
5
-
-
... More
9.118 Providing and fixing to existing door frames.
9.118.1 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides.
The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
1.55
-
-
... More
10.30 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :
10.30.1 4.0 mm thick glass panes
16.97
-
-
... More
13.4 12 mm cement plaster of mix 13.4.2 1:6 (1 cement: 6 coarse sand)
164.35
-
-
... More
13.5 15 mm cement plaster on rough side of single or half brick wall of mix 13.5.2 1:6 (1 cement: 6 coarse sand)
155.93
-
-
... More
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
9.48.1 Fixed to steel windows by welding
450
-
-
... More
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
10.16.3 Electric resistance or induction butt welded tubes
1333.49
-
-
... More
12.1 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
147.17
-
-
... More
12.4 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m²
12.6
-
-
... More
2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
80.24
-
-
... More
2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
107
-
-
... More
11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),
jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
11.41.2 Size of Tile 600x600 mm
113.7
-
-
... More
11.39 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4
(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
4.46
-
-
... More
8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
19.62
-
-
... More
13.9 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
13.9.1 12 mm cement plaster
27
-
-
... More
12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
107
-
-
... More
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
28.44
-
-
... More
13.26 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
355.78
-
-
... More
13.41 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
264.49
-
-
... More
13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
13.43.1 Water thinnable cement primer
91.29
-
-
... More
13.44 Finishing walls with water proofing cement paint of required shade :
13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
91.29
-
-
... More
13.52 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
16.98
-
-
... More
13.52 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.
13.52.1 On steel work
26.06
-
-
... More
9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete 9.96.2 250x16 mm:
2
-
-
... More
9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
9.97.2 250x10 mm
8
-
-
... More
9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
9.100.1 125 mm
8
-
-
... More
(B.) Sanitary Instalation
Septic Tank
2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil.
10.32
-
-
... More
16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :
16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
5.18
-
-
... More
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
1.04
-
-
... More
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
5.22.1 Mild steel and Medium Tensile steel bars
54.44
-
-
... More
5.9 Centering and shuttering including strutting, propping etc. and removal of form for
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
0.28
-
-
... More
5.9.3 Suspended floors, roofs, landings, balconies and access platform
1.7
-
-
... More
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
0.46
-
-
... More
6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
3.26
-
-
... More
6.12 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :
6.12.2 cement mortar 1:4 (1 cement : 4 coarse sand)
1.64
-
-
... More
13.4 12 mm cement plaster of mix :
13.4.2 1:6 (1 cement: 6 coarse sand)
18.9
-
-
... More
13.9 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
13.9.1 12 mm cement plaster
18.9
-
-
... More
19.18 Supplying and fixing C.I. cover without frame for manholes :
19.18.2 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
2
-
-
... More
17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
17.3.1 W.C. pan with ISI marked white solid plastic seat and lid
1
-
-
... More
17.7A Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-
(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
1
-
-
... More
17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
1
-
-
... More
18.65 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
1
-
-
... More
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
17.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
1
-
-
... More
17.35 Providing and fixing soil, waste and vent pipes :
17.35.1 100 mm dia
17.35.1.1 Sand cast iron S&S pipe as per IS: 1729
10
-
-
... More
17.36 Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
17.36.2 100 mm dia pipe
1
-
-
... More
19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1
-
-
... More
(C.) Water supply work inclluding Water Tank Stage
2.8 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil.
1.37
-
-
... More
16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :
16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1.96
-
-
... More
4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
0.6
-
-
... More
10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
413.42
-
-
... More
18.42 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :
18.42.3 Beyond 12 m and up to 18 m depth
40
-
-
... More
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
18.9.5 40 mm nominal dia Pipes
40
-
-
... More
18.43 Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality.
3
-
-
... More
23.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
4
-
-
... More
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1000
-
-
... More
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
18.7.5 40 mm nominal dia Pipes
30
-
-
... More
18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
18.8.3 25 mm nominal dia Pipes
10
-
-
... More
18.8.1 15 mm nominal dia Pipes
20
-
-
... More
18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
18.52.1 15 mm nominal bore
4
-
-
... More
(D.) Earth Filling
2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
115.2
-
-
... More
(E.) For Internal Electrifications
1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
1.10.1 Group A
16
-
-
... More
1.10.2 Group B
10
-
-
... More
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
180
-
-
... More
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
90
-
-
... More
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
15
-
-
... More
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1.24.1 5/6 A switch
4
-
-
... More
1.24.3 15/16 A switch
2
-
-
... More
1.24.4 3 pin 5/6 A socket outlet
4
-
-
... More
1.24.5 6 pin 15/16 A socket outlet
2
-
-
... More
1.24.8 Bell push
1
-
-
... More
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
10
-
-
... More
1.27 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
1.27.2 3 Module (100mmX75mm)
3
-
-
... More
1.27.4 6 Module (200mmX75mm)
2
-
-
... More
1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.2 3 Module
3
-
-
... More
1.28.4 6 Module
2
-
-
... More
1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
22
-
-
... More
1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
1
-
-
... More
1.58 Supplying and fixing PVC batten/ angle holder including connections etc. as required.
3
-
-
... More
2.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.3.2 8 way , Double door
1
-
-
... More
2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.10.1 Single pole
6
-
-
... More
2.10.2 Single pole and neutral
1
-
-
... More
2.12 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 40 A
1
-
-
... More
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1
-
-
... More
5.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
14.12
-
-
... More
7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
7.1.1 Upto 35 sq. mm
32
-
-
... More
12.34 Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the
required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
3
-
-
... More
MR-1 Supplying with including fitting fixing of Ceiling fan (1400 mm) etc. as directed by the Deptt.
10
-
-
... More
MR-2 Supplying with including fitting fixing of ADORE LED PLUS 9 W / 10 W. etc as required & directed by the Deptt.
3
-
-
... More
MR-3 Supplying with including fitting fixing of 18 W Slim LED batten with polycarbonatye round-shape diffuserGrey end cap, housing in an ideal replacement solution for existing battens/ fluorescent lamps with elegantly designed end caps etc. as required and directed by the Deptt.
11
-
-
... More
MR-4 Supplying with including fitting fixing of Exhaust Fan etc. as directed by the Deptt.
1
-
-
... More
MR-5 Supplying with fitting andf fixing of 1 H.P Motor Pumps set (Crompton/ Kirlosjar / Usha or equivalent make) as required and directed by the department.
1
-
-
... More
MR-6 Supplying with fitting & fixing of highy effective front openable 45 W IP66 Street light/ Campus Light with aluminium pressure dia-cost housing, toughened glass in the front and peanut lens for batwing light distribution to ensure light distribution, gigher spacing between poles and maintanance free system etc. asrequired and as directed by the Department (Orient, Bajaj, Havells or equivalent make)
3
-
-
... More
MR-7 Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid aluminium eonductor up to 10 Sqmm balance stranded conductor, XLPE Insulated cores laid up PVC tape inner sheathed aromour (Alumunium wire for single core up to 70 sq. mm balanance aluminuum strip glavanised wire for cables up to 2 x 10 sq mm ,4 x6 sq mm & balance all glavanized steel strip), extruded PVC type ST2 sheathed 650/1100 V grade as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the Deptt. (Havells, RR, or equivalent make as approved by this Deptt.) (i) 10.00 sq.mm 2 Core U.G Cable
44
-
-
... More
MR-8 Supplying with fitting and fixing single Phase Digital type Energy Meter Tested with APDCL including Load Security, Meter security, Labour charge and connection charge with all accessories materials as required complete as directed by the deptt. (Load=3 KW)
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements