BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 6,22,739Document Cost
₹ 6,300Tender Fee
Refer Documents
Summary
Construction Of Cc Block Road From 2 No. Uttar Dimakuchi (soni Mandir) To Dimakuchi Gadhuli Via 3 No. Uttar Dimakuchi Kalahandi Chuba Under Cms Goodwill Mission Project For The Financial Year 2023-24 Of District Udalguri. (tn_26_128_r)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BTC_36276_1Bid Award Id
ViewTender No
ACE-150/PWD/NIT/Goodwill/23-24Tender Authority
Bodoland Territorial Council ViewPurchaser Address
-Website
http://https://www.bodoland.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
4.1.(ii). Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface,mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in Place Method ii) For Grading II Material.
1875
-
-
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
1125
-
-
6.7. Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 including carriage. a) including Edge block/Edge restraints
15000
-
-
10.2. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801.
600mm equilateral triangle
2
-
-
600mm circular
2
-
-
800mm x 600mm rectangular
1
-
-
10.1. Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.
Ordinary Kilometer Stone (Precast)
4
-
-
200 m stone (precast)
16
-
-
10.16. Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on
back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG
sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be ........
1
-
-
16.6. Providing and laying of boulder apron laid in wire crates with 4 mm dia Gl wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause.
At Ch. 2900m
216
-
-
2m Span Slab Culvert
11.1. Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side. I. Ordinary soil. (i) Upto 3m depth. A. Manual Means (Depth up to 3m)
79.27
-
-
11.4. PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing
A. With crushed stone. I. P.C.C. grade M10 (i) Nominal mix 1:3:6.
8.95
-
-
11.4. Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.
B. PCC Grade M 15, III. PCC grade M15 (i) Nominal mix (1:2.5:5)
72.43
-
-
11.4 Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.
IV. RCC Grade M20
9.1
-
-
13.5 Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.
1.29
-
-
11.51 Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MORTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size toeards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification.
15.51
-
-
17.49. Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
16
-
-
17.47 Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub structure complete as per drawing and technical specifications.
1.18
-
-
17.65 Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space.
5.2
-
-
17.67 Drainage Spouts complete as per drawing and Technical specification.
2
-
-
1000mm Dia SHPC
11.1. Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
32.68
-
-
9.7 PCC M10(1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawing and technical specification clause 1109.
1.81
-
-
9.2 Laying 1st class bedding on well compacted sand, moorum as per clause 1105.
(ii)Granular bedding.
3.45
-
-
9.8 Brik masonry work in cement mortar in foundation of wall complete excl. pointing and plastering as plastering as per drawing and technical specification clauses ….
16.76
-
-
9.3 Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. B)1000mm dia.
7.5
-
-
9.11 Plastering with cement mortar (1:4) 15mm thick on brick work for substructure as per technical Specification.
27.62
-
-
600mm Dia SHPC
Earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing od side (1) Ordinary Soil (A) Manual means.
35.5
-
-
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per
drawings & Technical Specification Clause 1109.
1.81
-
-
Bedding for pipe (ii) Type B (First Class) Bedding Laying (First Class) bedding on well compacted sand moorum as per Clause 1105 (ii) (i) Sand Filling.
2.62
-
-
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203.
In (1:4 Cement mortar).
15.95
-
-
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204.
20.1
-
-
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. 600 mm dia.
7.5
-
-