Bodoland Territorial Council Tender

BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.

Bodoland Territorial Council - BTC Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date26 Dec 2024
Closing Date3 Jan 2025
Tender Amount₹ 31,36,139 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(15.2) Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (15.2.2) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)

5.49

-

-

... More
B) Isolation Ward: (2.8) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.

36.29

-

-

... More
(16.12.1) Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : (a).Brick on flat soling.

142.09

-

-

... More
(4.1.6) 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)

2.65

-

-

... More
(11.5) 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

99.37

-

-

... More
(5.22) Steel reinforcement for R... Work inluding sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.6. TMT bar Fe500D or more.

1969.39

-

-

... More
(5.9) Centering and shuttering inluding strutting, propping etc end removal of the same...5.9.1. Foundation Footing, base of column etc. For mass concrete. (5.9.5) Lintels, beams, plinth beams, girders, bressumers and cantilevers

50.88

-

-

... More
(5.9.6) Columns, Pillars, Piers, Abutments, Posts and Struts

74.88

-

-

... More
(5.9.19) Weather shade, Chajjas, corbels etc., including edges

8.64

-

-

... More
(5.1) Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)

12.31

-

-

... More
(5.2) Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

2.3

-

-

... More
(5.3) Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

7.1

-

-

... More
(6.1)Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)

13.5

-

-

... More
(6.13 )Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)

128.21

-

-

... More
(13.5) 15 mmthick cement plaster in single coat on rough side of single or half brick wall 13.5.1. 1:4.(1 Cement : 4 Coarse Sand)

404.06

-

-

... More
(13.37) White washing with lime to give an even shade : 13.37.1 New work (three or more coats)

404.06

-

-

... More
(13.44) Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1.New work (Two or More coat @ 3.84 Kg/10m2

404.06

-

-

... More
(9.1)Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 9.1.3 Kiln seasoned and chemically treated hollock wood

0.24

-

-

... More
(10.5) Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 10.5.1 Using M.S. angels 40x40x6 mm for diagonal braces

25.38

-

-

... More
(16.70) Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. 16.70.1 Made of G.I. wire of dia 4 mm

25.38

-

-

... More
(9.7) Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : 9.7.2 Kiln seasoned and chemically treated hollock wood

8.82

-

-

... More
(9.55) Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws (9.55.2) 100x58x1.90 mmetc. complete :

96

-

-

... More
(9.63) Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 9.63.3 150x10 mm

20

-

-

... More
(9.66) Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 100 mm

20

-

-

... More
(2.27) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

49.69

-

-

... More
(10.16) Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.3 Electric resistance or induction butt welded tubes

1391.18

-

-

... More
(12.1) Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²

160.8

-

-

... More
(12.4) Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 12.4.1 0.80 mm thick with zinc coating not less than 275 gm/m²

24.9

-

-

... More
(9.48) Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete 9.48.2 Fixed to openings /wooden frames with rawl plugs screws etc.

1484.5

-

-

... More
(12.26) Providing and fixing plain multipurpose cement board (Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). 12.26.1 6 mm thick Cement fiber board as per IS: 14862

92.15

-

-

... More
(9.3) Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 9.3.1 Sal wood

0.27

-

-

... More
(4.17) Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.

43.2

-

-

... More
(13.48) Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : 13.48.2 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture

48.33

-

-

... More
13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture

60.84

-

-

... More
(11.41A) Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41.A.3.1 Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm

6.3

-

-

... More
(8.31) Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.

50.88

-

-

... More
C) SANITARY PLUMBING: (17.1) Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

1

-

-

... More
(17.3) Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (17.3.1) W.C. pan with ISI marked white solid plastic seat and lid

2

-

-

... More
(17.7) Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (17.7.1)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

1

-

-

... More
(17.8) Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.

1

-

-

... More
(17.16A) Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.

3

-

-

... More
(17.22A) Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.

3

-

-

... More
(17.28) Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (17.28.2) Flexible pipe (17.28.2.1) 32 mm dia

3

-

-

... More
(17.29) Providing and fixing 100 mm sand cast Iron grating for gully trap.

3

-

-

... More
(17.32) Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : (17.32.3) Oval shape 450x350 mm (outer dimensions)

1

-

-

... More
(17.35) Providing and fixing soil, waste and vent pipes 17 17.35.1 100 mm dia 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729

14

-

-

... More
(17.73) Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.

1

-

-

... More
(18.8) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 18.8.1 15 mm nominal dia Pipes

20

-

-

... More
(18.9) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 18.9.2 20 mm nominal dia Pipes

31

-

-

... More
(18.15) Providing and fixing brass bib cock of approved quality : 18.15.1 15 mm nominal bore

9

-

-

... More
(18.16) Providing and fixing brass stop cock of approved quality : 18.16.1 15 mm nominal bore

9

-

-

... More
(18.20) Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 18.20.1 15 mm nominal bore

4

-

-

... More
18.20.2 20 mm nominal bore

2

-

-

... More
(18.19A) Providing and fixing required Stainless Steel Fitting of press fit design of grade 316L as per IS 6911:2017 and conforming to EN-10312 standards with V-profile and with O-ring sealing gasket of EPDM material of required dia as per direction of Engineer-in-charge. Elbow 90° For 15 mm outer dia pipe

5

-

-

... More
(18.19A.2) For 22 mm outer dia pipe

4

-

-

... More
(D) RCC Staging (2.8) Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil.

7.34

-

-

... More
(16.12.1 )Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : (a).Brick on flat soling.

7.76

-

-

... More
(4.1.6) 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)

0.68

-

-

... More
(5.22) Steel reinforcement for R... Work inluding sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.6. TMT bar Fe500D or more (5.22.1) Mild steel and Medium Tensile steel bars

599.16

-

-

... More
(5.9) Centering and shuttering inluding strutting, propping etc end removal of the same...5.9.1. Foundation Footing, base of column etc. For mass concrete. (5.9.5) Lintels, beams, plinth beams, girders, bressumers and cantilevers

16.8

-

-

... More
(5.9.6) Columns, Pillars, Posts & Strut

24.4

-

-

... More
(5.9.3) Suspended floors, roofs, landings, balconies and access platform

4

-

-

... More
(5.1) Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(5.1.3)1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)

2.44

-

-

... More
(5.2) Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

0.84

-

-

... More
(5.3) Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).

1.48

-

-

... More
(13.5) 15 mmthick cement plaster in single coat on rough side of single or half brick wall (13.5.1) 1:4.(1 Cement : 4 Coarse Sand)

48.4

-

-

... More
(13.37) White washing with lime to give an even shade : (13.37.1) New work (three or more coats)

48.4

-

-

... More
(13.44) Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1.New work (Two or More coat @ 3.84 Kg/10m2

48.4

-

-

... More
(12.1) Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (12.1.3) 0.63 mm thick with zinc coating not less than 275 gm/ m²

6.76

-

-

... More
(E) Deep Tubewell (23.1) Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. (23.1.2)Rocky strata including Boulders (23.1.2.1)300 mm dia

42

-

-

... More
(23.3) Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (23.3.2) 150 mm nominal size dia

42

-

-

... More
(23.8) Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.

2

-

-

... More
(23.12)Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.

24

-

-

... More
(23.15) Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). (23.15.2)150 mm dia

1

-

-

... More
(18.43) Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality.

2

-

-

... More
(18.46) Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : (18.46.5) 40 mm nominal bore

2

-

-

... More
(18.9) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (18.9.2)20 mm nominal dia Pipes

30

-

-

... More
(18.9.3)25 mm nominal dia Pipes

40

-

-

... More
(18.9.5)40 mm nominal dia Pipes

40

-

-

... More
(18.19) Providing and fixing gun metal non- return valve of approved quality (screwed end) : (18.19.3) 40 mm nominal bore (18.19.3.2) Vertical

1

-

-

... More
(F) Electrical 1.10:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core etc. as required. 1.10.1 Group A

12

-

-

... More
1.10.2 Group B

10

-

-

... More
1.10.3 Group C

8

-

-

... More
1.14 :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 2 x 2.5 sq. mm + 1 x 1.5 sq. mm earth wire

225

-

-

... More
1.14.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire

147

-

-

... More
1.14.4 2 x 6 sq. mm + 1 x 6sq. mm earth wire

40

-

-

... More
1.21 :- Supplying and fixing following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1.21.1 20mm

45

-

-

... More
1.21.2 25 mm

48

-

-

... More
1.21.3 32 mm

38

-

-

... More
1.24 :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.24.1 5/6 A switch

6

-

-

... More
1.24.3 15/16 A switch

2

-

-

... More
1.24.4 3 pin 5/6 socket outlet

6

-

-

... More
1.24.5 6 pin 15/16 socket outlet

2

-

-

... More
1.24.8 Bell Push

1

-

-

... More
1.25 :- Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

5

-

-

... More
1.28 :- Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1.28.3 4 Module

8

-

-

... More
1.28.5 8 Module

3

-

-

... More
1.28.6 12 module

2

-

-

... More
1.33 :- Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required

16

-

-

... More
1.34 :- Supplying and fixing brass batten/ angle holder including connection etc. as required.

14

-

-

... More
1.44 :- Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

5

-

-

... More
1.50 :- Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1.50.1 Upto 450 mm sweep

3

-

-

... More
2.3 :- Supplying and fixing following way, single pole and neutral, shee steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.1 1 way, Double door

1

-

-

... More
2.10 :- Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1 Single pole

4

-

-

... More
2.10.3 Double pole

1

-

-

... More
2.14 :- Supplying and fixing following rating double pole (Single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.2 40A

1

-

-

... More
2.18 :- Supplying and fixing 20A, 240 V, SPN Industrial type socket putlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. As required.

2

-

-

... More
5.2 :- Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.

1

-

-

... More
5.17 :- Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

18

-

-

... More
MR – 1:- Supplying with including fitting fixing Of ceiling fan etc. as directed by the Deptt.

5

-

-

... More
MR – 2:- Supplying including fitting fixing of 18 W Slim LED batten with polycarbonate round-shape diffuser. Grey end cap, housing is an ideal replacement solution for existing battens / fluorescent lamps with elegantly designed end caps etc. As required and directed by the Deptt.

9

-

-

... More
MR – 3:- Supplying with including fitting fixing of DORE LED PLUS 9 W / 10W. Etc. As directed by the Deptt.

14

-

-

... More
MR – 4:- Supplying with including fitting fixing of Exhaust Fan etc. As directed by the Deptt.

3

-

-

... More
MR:- 5- Payment to be made to the APDCL Authority for load Security.

3

-

-

... More
MR – 6:- Sl. No. 496. Material code 200237 HSN Code. 9028 1 phase 2 wire whole current pre – payment energy meter 240V, 10-60 A Class 1.0 along with freedom unit and 10 m 4 – core telephone wire. 4.00 sq.mm 2 Core U.G Cable Considering 100 Mtr. Length.

1

-

-

... More
MR:- 7 – Smart Integrated Solar Street light with built in mono Cryslatine panel lithium l on Battery (LIFE PO4), MPPT charge controller and RIP sensor with Coliser Temperature 6000 – 6500K. Bajaj make.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.