Bodoland Territorial Council Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 4,01,299Document Cost
₹ 4,100Tender Fee
Refer Documents
Summary
Construction Of Rcc Bridge No. 1/1 On Harpur To Chandana Bagan Under Cms Goodwill Mission Project Under Sopd-g For The Year 2023-24. (tn_26_161)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BTC_37693_1Bid Award Id
ViewTender No
ACE-150/PWD/NIT/Goodwill/23-24Tender Authority
Bodoland Territorial Council ViewPurchaser Address
-Website
http://https://www.bodoland.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in Place Method ii) For Grading II Material.
114.75
-
-
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.
3) Grading-Ill (A) By Manual Means.
57.38
-
-
Inter locking concrete Block pavement Providing and laying shaded interlocking concrete block pavement having thickness 80mm as per IS 15658 2006(Compressive strength 47.2N/mm sq.
765
-
-
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MOSRT&H's fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenanc.
220
-
-
Providing & fixing retro - reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801. 600mm X 600mm square.
4
-
-
Bridge Work
Excavation for Structures (Earth work in excavation of foundation of Cum structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil, Manual means, (i)Without dewatering upto 3.00 m depth.
310
-
-
Excavation for Structures (Earth work in excavation of foundation of Cum structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary Soil, Manual means, (i)Without dewatering, upto 3.00 m to 6.00m depth.
280
-
-
Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing and as per Clause 1200 & 1900 of MORT&H Specification.
2.52
-
-
Plain/Reinforced cement concrete, in well foundation complete as per drawing and Technical specification including steel shuttering formwork (p) with plasticiser (Masterplast PL-1/SPL-2 or equivalent). air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Master plast ACPL or equivalent) Conforming to IS-9103-1999 A) Well Curb, RCC M-25 Grade, Case-1 Using Concrete Mixer
58.54
-
-
Plain/Reinforced cement concrete, in well foundation complete as per drawing and Technical specification including steel shuttering formwork (p) with plasticiser (Masterplast PL-1/SPL-2 or equivalent). air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Master plast ACPL or equivalent) Conforming to IS-9103-1999 B) Well Staining, v) RCC M-25 Grade, Case-1 Using Concrete Mixer
527.86
-
-
Plain/Reinforced cement concrete, in well foundation complete as per drawing and Technical specification including steel shuttering formwork (p) with plasticiser (Masterplast PL-1/SPL-2 or equivalent). air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Master plast ACPL or equivalent) Conforming to IS-9103-1999.
C) Bottom Plugging, v) PCC M-30 Grade, Case-1 Using Concrete Mixer
147.22
-
-
Plain/Reinforced cement concrete, in well foundation complete as per drawing and Technical specification including steel shuttering formwork (p) with plasticiser (Masterplast PL-1/SPL-2 or equivalent). air entraining and water reducing plasticiser (Masterplast PAE or 10/17. equivalent) and accelerating plasticiser (Master plast ACPL or 13(iii) equivalent) Conforming to IS-9103-1999.
E)Top Plugging, v) Grade-M-25 PCC, Case-1 Using Concrete Mixer.
19.64
-
-
Plain/Reinforced cement concrete, in well foundation complete as per drawing and Technical specification including steel shuttering formwork (p) with plasticiser (Masterplast PL-1/SPL-2 or equivalent). air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Master plast ACPL or equivalent) Conforming to IS-9103-1999.
F) Well cap, v) RCC Grade M-30, Case-1 Using Concrete Mixer.
117.17
-
-
Sinking of 7 m external diameter well (other than pneumatic method of sinking) Thruough all types of strata namely sandy soil clayey soil and rock as shown against each case, complete as per drawing and technical specification. Depth of sinking is rekonewed from bed level' B)Clayey soil (7m dia Well) (i) Depth below bed level upto 3.0m.
6
-
-
Sinking of 7 m external diameter well (other than pneumatic method of sinking) Thruough all types of strata namely sandy soil clayey soil and rock as shown against each case, complete as per drawing and technical specification. Depth of sinking is rekonewed from bed level. B) 'Clayey soil (7m dia Well) (ii)Beyond 3m upto 10m depth.
14
-
-
Sinking of 7 m external diameter well (other than pneumatic method of sinking) Through all types of strata namely sandy soil clayey soil and rock as shown against each case, complete as per drawing and technical specification. Depth of sinking is rekonewed from bed level, B) Clayey soil (7m dia Well) (iii)Beyond 10m upto 20m depth (a) For sinking.
12
-
-
Sand filling in wells complete as per drawing and technical specifications as per MORT&H section No.1207.
518.43
-
-
Reinforcement in Foundation: Supplying, fitting and placing TMT 1S :1786 Fe-500 D bar reinforcement in foundation complete as per drawing and technical specifications TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent).
32.83
-
-
SUB-STRUCTURE
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification and steel shuttering formwork (P). With plasticiser (Masterplast PL-1/SPL-2 or equivalent) air entraining and water reducing plasiciser (Masterplast ACPL or equivalent) conforming to IS- 9103-1999.
G) RCC Grade M-30, b) Height 5m to 10m, Case-1 Using Concrete Mixer
79.01
-
-
Supplying, fitting and placing conforming to IS:1786 TMT reinforcement bar Fe-500 from primary producer like TATA/SAIL/SHYAM STEEL/ESSER STEEL/JINDAL STEEL/RINL etc. in Sub Structure complete as per drawing and technical specifications TMT IS 1786 (Fe-500 D) from Primary Producer like TATA/SAIL/SHYAM STEEL/ESSER STEEL/JINDAL STEEL/RINL etc.
9.71
-
-
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MORTH specifications complete including all accessories as per drawing and Technical Specifications.
106920
-
-
Back filling behind abutment, wing wall and return wall Cum complete as per drawing and Technical Specification. A.Granular material.
236.45
-
-
Providing weep holes in Brick massonry/ Plain/Reinforced Each concrete abutment wing wall/ return wall with 100mm dia AC pipe extending through the full width of the structure as per drawing and Technical specification.
40
-
-
SUPER STRUCTURE
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification' including steel shuttering formwork. (P). With plasticiser (Masterplast PL-1/SPL 2 or equivalent) air entraining and water reducing plasiciser (Masterplast PAE or equivalent and accelerating plasticiser) (Masterplast ACPL or equivalent) conforming to IS-9103-1999.
Without Plasticiser, RCC Grade M-25, Using Batching Plant, Transit Mixer and concrete pump, Height 5m to 10m.
114.5
-
-
Reinforcement in Super Structure: Supplying, fitting and placing conforming to IS:1786 TMT reinforcement bar Fe-500 from primary producer like TATA/SAIL/SHYAM STEEL/ESSER STEEL/JINDAL STEEL/ RINL etc. in Super-Structure complete as per drawing and technical specifications.
a) TMT IS 1786 (Fe-500 D) from Primary Producer like TATA/SAIL/SHYAM STEEL/ESSER STEEL/JINDAL STEEL/RINL etc.
17.59
-
-
Providing and laying Cement concrete wearing coat M-30 grade Cum including reinforcement complete as per drawing and Technical Specifications Clauses 800, 1206.3 A) With Crushed Stone.
14.24
-
-
Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
66.64
-
-
Strip Seal Expansion Joint Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70mm complete as per approved drawings and standard specifications to be installed by the manufacture/supplier or their authorised representative ensuring compliance to the manufactures instructions for installation.
15
-
-
Drainage Spouts complete as per drawing and Technical specification.
15
-
-
Painting on concrete surface
Providing and applying 2 coats of water based cement paint to un plastered concrete surface after cleaning the surface of dirt, dust oil, grease efflorescence and applying paint @ of 1 litre for 2 sqm).
B) For RCC Railing.
180
-
-
Type-A, "W": Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2m center to center, 1.8 m high, 1.1m below ground/road level, all steel parts and fitments to be galvanized by hot dip process, all fitting to conform to IS:1367 and 15:1364, metal beam rail to be fixedon the vertical post with a spacer of channel section 150mmX75mmX5mm, 330mm long complete as per clause 810.).
40
-
-
PROTECTION WORK
Providing and laying of boulder apron laid in wire crates with 4 mm dia Gl wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 40 kg each.
80.4
-
-
Providing and laying filter material underneath pitching in slopes Cum complete as per drawing and technical specifications Clause 1302.
42.3
-
-
Providing and laying pitching on slopes laid over prepared filter Cum media as per drawing and technical specifications Clause 1302 A. Stone/Boulder.
84.6
-
-
Evaluation Notes How It Works ?