Bodoland Territorial Council Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,92,957Document Cost
₹ 2,000Tender Fee
Refer Documents
Summary
Const. Of Addl. Class Room At Panery College In Udalguri District. (tn_03_2)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BTC_38018_1Bid Award Id
ViewTender No
ACE-35/TECH/UDL(RB)/IFB/18-19Tender Authority
Bodoland Territorial Council ViewPurchaser Address
-Website
http://https://www.bodoland.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
5.22. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
5.22.6. Thermo Mechanically Treated bars of grade Fe- 500D or more.
6409.85
-
-
5.22A. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
5.22A.6. Thermo Mechanically Treated bars of grade Fe- 500D or more.
12484.5
-
-
5.22A. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
5.22A.1 Mild steel and Medium Tensil steel bars.
149.92
-
-
5.9. Centering and shuttering including strutting propping etc. and removal of form for:
5.9.1. Foundation, footing, bases of columns etc. for mass concrete
136.08
-
-
5.9.6. Columns, Pillars, Piers, Abutments, Posts and Struts
172.62
-
-
5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers
296.23
-
-
5.9.3. Suspended floor, roofs, landing, balconies and access platform
382.41
-
-
5.9.7. Stairs, (excluding landing) except spiral starcases
9.19
-
-
5.1. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering finishing and reinforcement All work up to plinth level:
5.1.2 1:1:5:3 (1 cement : 1.5 coarse sand ( zone III) 3 graded stone aggregate 20 mm nominal size)
68.05
-
-
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering. shuttering, finishing and reinforcement:
5.2.2 1:15:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
14.34
-
-
5.3. Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering. shuttering, finishing and reinforcement with 1:15:3 (1 cement: 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size).
65.79
-
-
6.1. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
6.1.1 Cement mortar 1:4 (1 cement: 4 coarse sand)
26.1
-
-
6.13. Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand)
445.49
-
-
10.14. Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by Engineer in charge
10.14.2 Profile C
10.14.2.1 Fixing with adjustable lugs with split end tail to cach jamb
33.3
-
-
9.20. Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply vencering with vertical grains or cross bands and face vencers on both faces of shutters.
9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
17.01
-
-
10.15. Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size)
1477.46
-
-
10.30. Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with:
10.30.1 4.0 mm thick glass panes
24.48
-
-
9.117. Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance +Imm), with wall thickness 2.0 mm (+ 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (+ 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineerin-charge
9.117.1 Extruded section profile size 48x40 mm
19.8
-
-
9.118. Providing and fixing to existing door frames.
9.118.1 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (+ 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (+ 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (+ 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
6.3
-
-
13.4. 12 mm cement plaster of mix:
13.4.2 1:6 (1 cement: 6 coarse sand)
894.76
-
-
13.5. 15 mm cement plaster on rough side of single or half brick wall of mix:
13.5.2 1:6 (1 cement: 6 coarse sand)
506.37
-
-
9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
9.48.1 Fixed to steel windows by welding
649.65
-
-
2.25(a) Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
245.4
-
-
2.35. Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):
2.35.3 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement: 2 Coarse sand) to match the existing floor.
2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
327.21
-
-
11.41. Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
11.41.2 Size of Tile 600x600 mm
328
-
-
11.39. Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make, in colours White, Ivory, Grey. Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete.
33.44
-
-
8.31. Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 13 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
111.62
-
-
13.9. Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
13.9.1 12 mm cement plaster
77.22
-
-
10.16. Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
10.16.3 Electric resistance or induction butt welded tubes kg 140.85
136.97
-
-
12.1. Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12.1.3 0.63 mm thick with zinc coating not less than 275 gm/m²
30.63
-
-
4.17. Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone - III): 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
84.6
-
-
13.26. Providing and applying plaster of paris putty of 2 mm thickness over plastered surface
13.26 to prepare the surface even and smooth complete.
940.89
-
-
13.41. Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:
13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
940.89
-
-
13.43. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:
13.43.1 Water thinnable cement primer
229.07
-
-
13.44. Finishing walls with water proofing cement paint of required shade:
13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
229.07
-
-
13.52. Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation ofsurface, etc. complete.
13.52.1 On steel work
95.78
-
-
9.96. Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:
9.96.2 250x16 mm
6
-
-
9.97. Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
9.97.2 250x 10 mm
20
-
-
9.100. Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:
9.100.1. 125 mm
20
-
-
SANITARY WORKS
12.41. Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion,
(i) Single socketed pipes.
12.41.2. 110 mm diameter
35
-
-
18.8. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
18.8.2 20 mm nominal outer dia Pipes
30
-
-
18.8.3 25 mm nominal outer dia Pipes
30
-
-
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
18.9.5. 40 mm nominal outer dia Pipes
20
-
-
18.15. Providing and fixing brass bib cock of approved quality
18.15.2 20 mm nominal bore
6
-
-
17.7. Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
17.7.1 White Vitreous China Wash basin size 630x450 mm with Nos a pair of 15 mm C.P. brass pillar taps
4
-
-
17.1. Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of size Nos 580x440 mm with integral type foot rests
4
-
-
12.42. Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion.
12.42.3 Single tee with door
12.42.3.2 110x110x110 mm
6
-
-
12.42.5 Bend 87.5°
12.42.5.2 110 mm bend
6
-
-
18.48A Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI: 12701, colour of opaque white or as approved by Engineer-in-charge.The rate includesmaking necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. NS(annex) Bio Septic tank
2000
-
-
Bio Septic tank
1
-
-
DTW BORING
23.1. Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
23.1.1 All types of soil
23.1.1.1. 300 mm dia
55
-
-
23.10. Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per directionof Engineer-in- charge.
23.10.1 100 mm nominal size dia having minimum wall thickness 5.00 mm
45
-
-
23.8. Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading&sizes as per actual requirement, all complete as per direction of Engineer-in- charge.
7
-
-
18.44. Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well RM including cleaning and priming the tube well.
45
-
-
18.43 Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of Nos approved quality.
10
-
-
18.59 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately):
18.59.1 50 mm dia
1
-
-
23.12 Development of tube well in accordance with IS: 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer in-charge.
22
-
-
SITE DEVELOPMENT
2.25. Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in cum trenches, plinth, sides of foundation etc. complete.
527
-
-
ELECTRICAL WORKS
1.10:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core etc. as required.
1.10.1 Group A
28
-
-
1.10.2 Group B
24
-
-
1.10.3 Group C
18
-
-
1.14 :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.14.1 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth
285
-
-
1.14.2 2 x 2.5. sq. mm + 1 x 2.5 sq. mm earth
348
-
-
1.14.3 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
199
-
-
1.14.4 2 x 6 sq. mm + 1 x 6sq. mm earth wire
115
-
-
1.15:- Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. FRLS PVC insulated copper conductor single core cable and 1.5 sq. mm FRLS insulated copper conductor single core cable as earth wire in existing syrface/ recessed steel/PVC conduit including dismantling as required.
1.15.1 Group A
18
-
-
1.15.2 Group B
15
-
-
1.15.3 Group C
12
-
-
1.21 :- Supplying and fixing following sizes of medium class PVC conduit along with accessories in surface/recessed including cutting he wall and making good the same in case of recessed conduit as required.
1.21.1 20mm
105
-
-
1.21.2 25 mm
85
-
-
1.21.3 32 mm
65
-
-
1.31:- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc, as required.
15
-
-
1.32 :- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
5
-
-
1.25:- Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
40
-
-
1.28:- Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1.28.3 4 Module
15
-
-
1.28.4 6 Module
2
-
-
1.28.5 8 Module
9
-
-
1.28.6 12 module
6
-
-
1.33-Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required
53
-
-
1.24 - Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1.24.2 2 way 5/6 A switch
14
-
-
1.44 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
26
-
-
1.50 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
1.50.1 Upto 450 mm sweep
4
-
-
2.3-Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
2.3.2 8 way, Double door
3
-
-
2.10 - Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.10.1 Single pole
18
-
-
2.10.3 Double pole
3
-
-
2.14 :- Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB) having a sensitivity current 30 mA int he existing MCB DB complete with connections, testing and commissioning etc. as required.
2.14.2 40A
3
-
-
5.2-Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
3
-
-
5.17:- Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
64.65
-
-
7.1:- Laying of one number PVC insulated and PVC sheathed/ XL power cable of 1.1 KV grade of following size direct in grol including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1 Ulp to 35 sq. mm
180
-
-
MR-1:- Supplying with including fitting fixing of ceiling fan etc. as directed by the Deptt.
45
-
-
MR-2:- Supplying including fitting fixing of 18 W Slim LED batten with polycarbonate round-shape diffuser. Grey end cap, housing is an ideal replacement solution for existing battens / fluorescent lamps with elegantly designed end caps etc. As required and directed by the Deptt.
55
-
-
MR-3:- Supplying with including fitting fixing of DORE LED PLUS 9 W/ 10W. Etc. As directed by the Deptt.
60
-
-
MR-4:- Supplying with including fitting fixing of Exhaust Fan etc. As directed by the Deptt.
4
-
-
MR-5:- Supplying and fitting fixing 2 H.P. Single phase Centrifugal Mono block Pump set sync speed 2900 rmp. Model No. KDS- 213 with DOL Starter Control & switch gear (/ BCH/ L&T/Siemens/ equivalent make). With all accessories complete as required and as directed by the department.
1
-
-
MR-6:- Supplying erection with fitting & fixing of Kasper Mild steel 4 mt octagonal pole for street light inclusive GST.
8
-
-
MR-7:- Supplying with fitting fixing LED street light/ campus light made up pressure die cart having with prismatic poly caffeinate diffuser and individual LEDs with security optics end IP65 Protection EDGE street light.
8
-
-
MR-8:- Supplying fitting & fixing metal MS single asm pole bracket by street light India Mark ID 14541762948
8
-
-
MR-9-Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminum conductor up to 10 sqmm, balance stranded conductor, XLPE, In sulated, cores laid up, PVC tape inner sheathed Armoured (Aluminum wire for single core up to 70 sq. Mm, balance Aluminium strip, Glavanised wire for cables up to 2 x 10 sq. Mm, 3 x 10 sq. Mm, 4 x 6 sq. Mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR, or equivalent make as approved by this Deptt.) 10.00 mm2 2 core U.G. Cable
65
-
-
MR-10:- Supplying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminium conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium wire for single core up to 70 sq. mm balance Aluminium strip, Glavanised wire for cables up to 2 x10 sq. mm, 3 x 10 mm, 3 x 10 sq. mm, 4 x 6 sq. mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part-1) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR, or equivalent make as approved by this Deptt.) 6.00 sq.mm 2 Core U.G Cable
125
-
-
MR-11:- Supplying with fitting fixing of junction box 100 x 100 x 70 mm thick made of 1.66 thick CR sleet make Schneider electric Mureva. 6A MCB incomer and out going.
6
-
-
MR:-12-Sl. No. 496. Material code 200237 HSN Code. 9028 1 phase 2 wire whole current pre-payment energy meter 240V, 10-60 A Class 1.0 along with freedom unit and 10 m 4 - core telephone wire.
1
-
-
MR-13:- SLNO. 507- Metering cabinet Material code 112430 HSN 8535 (APDCL Schedule rate 2021 - 22)
1
-
-
Add. Payment to be made to the APDCL authority for load security.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements